HomeMy WebLinkAboutA6.1 - 190204DOOR SCHEDULE
DOOR
FRAME
DOOR #
TYPE
SIZE
MATERIAL
THICKNESS
GLASS
FINISH
MATERIAL
FINISH
TYPE
RATING
HEAD
JAMB
SILL
HARDWARE
REMARKS
DOOR /
106
FG
3'-0"%7'-0"
SCWD
13/4'
TEMPERED
EXISTING
KNOCKDOWN
EXISTING
F2
--
--
--
--
DI
--
104
105A
FG
(2)3'-Oi7'-0"
ALUM
13/4-
1 TEMPEED INSULATED.
EXISTING
ALUM
EXISTING
SF4
--
--
--
--
02
--
105A
105E
OL
(2)3'-OiO'-0"
ALUM
13/4'
1/4-
TEMPERED
MATCH
EXISTING
ALUM
EXISMATTING
SF4
--
--
--
--
13
--
1058
105C
F
(2)3'-Oi7'-0"
SCWD
1 3/4-
--
EMATCH
KNOCKDOWN
EXISTING
F1
--
--
--
--
12'
'SEE REMARK 01
105C
105D
F
(2)3'-Oi7'-0"
SCWD
1 3/4-
--
EXISTING
KNOCKDOWN
ATCH
EMATCH XISTING
F1
--
--
--
--
12'
'SEE REMARK 01
105D
107
F
3'_on x7'-O'
INSUL STL
1 3/4-
--
EXSTING ATCH
HIM
MATCH
STING
F1
--
--
--
--
14
--
107
108A
FG
3'_on x7'-O'
SCWD
1 3/4-
1/4'
TEMPERED
MATCH
EXISTING
KNOCKDOWN
MATCH
EXISTING
FI
--
--
--
--
09
--
101
1088
FG
3'-0"%7'-0'
SCWD
1 3/4
1/4'
TEMPERED
MATCH
EXISTING
KNOCKDOWN
MATCH
EXISTING
FI
--
--
--
--
09
--
108B
109A
FG
(2)3'-ON8'-0"
ALUM
1 3/4-
1" INSULATED.
TEMPERED
MATCH
EXISTING
ALUM
EXSTING ATCH
SF3
--
--
--
--
02
--
109A
109E
FG
(2)3'-ON8'-0"
ALUM
13/4'
14-
TEMPERED
MATCH
EXISTING
ALUM
EXISTING
SF3
--
--
--
--
13
--
109E
110
FG
3'_on x7'-O'
SCWD
1 3/4-
1/4
TEMPERED
MATCH
I EXISTING
KNOCKDOWN
MATCH
EXISTING
F1
--
--
--
--
06
--
110
11I
F
3'_on x7'-O'
SCWD
1 3/4-
--
EMATCH
KNOCKDOWN
EXISTING
F1
--
--
--
--
05
--
111
112
F
(2)3'-Oi7'-0"
SCWD
1 3/4-
--
EMATH
KNOCKDOWN
EMTCH NG
F1
--
--
--
--
07'
'SEE REMARK 01
112
113
F
3'_on x7'-O'
SCWD
1 3/4-
--
EXISTING
KNOCKDOWN
ATCH
EATCH M STING
F1
--
--
--
--
10
--
113
114
F
3'-0"X7'-0'
INSUL STL
13/4'
--
MATCH
EXISTING
HM
MATCH
EXISTING
F1
--
--
--
--
14
--
III
115
F
3'-0"%T-0'
SCWD
1 3/4-
--
MATCH
EXISTING
KNOCKDOWN
MATCH
EXISTING
F1
--
--
--
--
08
--
115
116
F
3'_on x7'-O'
SCWD
1 3/4-
--
MATCH EXISTING
KNOCKDOWN
EXSTING
F1
--
--
--
--
10
--
116
117
F
3'_on %T-0'
SCWD
13/4'
--
MATCH
EXISTING
KNOCKDOWN
MATCH
EXISTING
FI
--
--
--
--
08
--
117
11 BA
FG
(2)3'-O'0'-0"
SCWD
13/4'
TEMPERED
TO
MATCH T PT-5
KNOCKDOWN
MATCHTP ° 5
SFIO
--
--
--
--
13
--
11 BA
118E
FG
(2)3'-0')7'-0"
SCWD
13/4'
TEMPERED
MATCH PT-5
KNOCKDOWN
MATCHTP ° 5
SFIO
--
--
--
--
13
--
118E
118C
F
(2)3'-0'X7'-0"
SCWD
1 3/4-
--
MATCH EXISTING
KNOCKDOWN
EXISTING
FI
--
--
--
--
03
--
118C
118D
F
(2)3'-0'X7'-0"
SCWD
1 3/4'
--
EXSTING
KNOCKDOWN
EMATCH
FI
--
--
--
--
03
--
118D
118E
F
(2)3'-0'X7'-0"
INSUL STL
1 3/4-
--
MATCH EXISTING
HIM
EMATMG
F1
--
--
--
--
02
--
IIBE
118E
F
3'_on xY-0'
SCWD
1 3/4-
--
MAT
EXISTING
KNOCKDOWN
EX
F1
--
--
--
--
II
--
I18F
118G
F
(2)3'-0"X7'-0"
INSUL STL
1 3/4-
--
MATCH EXISTING
HIM
EXISTINGF1
--
--
--
--
02
--
118G
121
F
3'-0'X7'-0'
INSUL STL
1 3/4-
--
EXISTING
HIM
EATCH MATMG
F1
--
--
--
--
04
--
121
122
F
(2)3'-0'0'-0"
SCWD
1 3/4-
--
MATCH EXISTING
KNOCKDOWN
EXISTING MATCH
F1
03
122
124
F
3'_on xY-0'
SCWD
1 3/4-
--
EXISTING
KNOCKDOWN
EATCH MATMG
FI
--
--
--
--
05
--
124
DOOR SCHEDULE REMARKS:
REMARK 01: DOOR LOCK TO BE KEYED TO MATCH LOCKS ON STORAGE ROOMS IN EXISTING BUILDING. COORDINATE WITH OWNER.
11'-0"
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel
�N;X��3tD,NR>,XDA�1
DATE: 06/17/19
R•-n-
100MOki 1471_ Oki *16]:14pill 44
HARDWARE SET 01
HARDWARE SET
02
HARDWARE SET
03
3 HINGES
6
HINGES
6
HINGES
1 PASSAGE SET
2
PANIC HARDWARE SETS
2
DEAD BOLT
CYLINDER
3 MUTES
6
MUTES
LOCK (NO
LEVER)
1 WALL STOP
2
OVERHEAD
STOPS
6
MUTES
2
CLOSERS
2
OVERHEAD
STOPS
2
PERIMETER
SEALS
2
CLOSERS
4•-6.
HARDWARE SET 04 HARDWARE SET 05
3 HINGES 3 HINGES
1 ENTRANCE LOCKSET I PASSAGE SET
3 MUTES 3 MUTES
I OVERHEAD STOP I HINGE STOP
1 CLOSER
1 PERIMETER SEAL
HARDWARE SET 07 HARDWARE SET 08
2 POCKET DOOR PULLS 3 HINGES
2 POCKET DOOR TRACKS 1 PUSH/PULL
I POCKET DOOR KEYED 3 MUTES
LOCK 1 WALL STOP
1 CLOSER
HARDWARE SET 10
HARDWARE
SET
11
3 HINGES
3
HINGES
1 STOREROOM LOCKSET
1
DEAD BOLT
CYLINDER
3 MUTES
LOCK (NO
LEVER)
1 WALL STOP
3
MUTES
1 CLOSER
1
OVERHEAD
STOP
I
CLOSER
HARDWARE SET 13 HARDWARE SET 1d
6 HINGES 3 HINGES
2 PANIC HARDWARE SETS 1 PANIC HARDWARE SET
6 MUTES 3 MUTES
2 OVERHEAD STOPS 1 OVERHEAD STOP
2 CLOSERS 1 CLOSER
1 PERIMETER SEAL
HARDWARE SET 06
3 HINGES
I PRIVACY LOCKSET
3 MUTES
I WALL STOP
HARDWARE SET 09
3 HINGES
1 PRIVACY LOCKSET
3 MUTES
1 HINGE STOP
HARDWARE
SET 12
6
HINGES
2
STOREROOM LOCKSETS
6
MUTES
2
HINGE STOPS
2'-0'
-CLEAR
TEMPERED
CLASS
TYPE IF TYPE FG TYPE QL
KEYED NOTES
1. OPENING REQUIRED FOR DOOR OR PAIR OF ODORS -SEE
FLOOR PLAN FOR DOOR NUMBER, SWING ETC. REFER TO
DOOR SCHEDULE FOR DOOR SIZES THAT WILL DETERMINE
OPENING REQUIRED. DOORS ARE RESPONSIBILITY OF
STOREFRONT FRAMING MANUFACTURER AND MUST COMPLY
WITH ALL STATE AND LOCAL ADA CODE REQUIREMENTS.
2. 4 tu" X Y EXTRUDED ALUMINUM STOREFRONT FRAMING
SYSTEM, PRE -FINISHED WHITE. TYPICAL ALL STOREFRONT
UNLESS OTHERWISE NOTED.
3. PROVIDE I' SQUARE APPLIED MUTTINS ON EXTERIOR PANE.
4. 4 J' X 2' EXTRUDED ALUMINUM STOREFRONT FRAMING
SYSTEM, FINISH TO BE PAINTED TO MATCH PT-5.
Ia18k ilk 10&'1»1
11
V_6'
TYPEF2
GLAZING TYPES
ALL GLAZING TO BE I" INSULATED GLASS AT EXTERIOR
AND in INSULATED GLASS AT INTERIOR UNLESS NOTED
OTHERWISE.
T = SECTION OF GLAZING REQUIRED TO BE TEMPERED -
GLASS - USE 1' INSULATED TEMPERED GLASS AT
EXTERIOR APPLICATIONS, AND j" TEMPERED AT INTERIOR
LOCATIONS.
GLASS MUST MEET THE FOLLOWING SPECIFICATIONS FOR
COMPLIANCE WITH THE INDIANA ENERGY CONSERVATION
CODE FOR ENVELOPE CALCULATIONS:
LOW "E" COMING
'U" VALUE - MINIMUM OF 0.28
'SHGC" VALUE - MAXIMUM OF 0.47
11 SPANDREL GLAZING
TYP. "P � TYP. vP P TYP.
10'-R" d'-fi"
STOREFRONT ELEVATIONS
CURRAN
ARCHITECTURE
5719 LAWTON LOOP E. DR. #212
INDIANAPOLIS, IN 46216
O :: 317.288.0681
IF :: 317. 288.0753
,.�!; pc�sr[iirom'py
No. `y
• AR19600043'. •
MIT a _
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCE'TSCONTAINEJHERON ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITEUME, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
Q CWMIGHT 2019. CURRAN MMRECTURE
PLAYSCHOOL
AT LEGACY
GYM ADDITION
14454 COMMUNITY DRIVE
CARMEL, INDIANA 46032
REVIEW SET 1.16.18
BID SET '1.26. 18
PERMIT S-T 02.04.19
zLADDENDUM DI 02.04.19
IZI