Loading...
HomeMy WebLinkAboutA5.2 - 190204tiJOIST BEARING t2'�I I tiSEE STRUCTURAL I I I I I I I tiB.O. HEADER I 9' T.O. CONCRETE A RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City BF Centel (� �VT�A7'�B*tiYWML DATE: 06/17/19 � CARING 'IIIII1 rs��'tl ____ tiJ0%!B 1/A5.6 15 0,20'-6" CEILING HEIGHT 39 ' I ,WINDOW HEAD tiWINDOW SILL a --a REFER TO SHEET A2.1 WINDOW SILL 6 SLOPE 2/A5.6 I WALL SECTION 2 314" - I'-0" I I I I I I i� 16'-d 3/d' lilOII IY-0" WINDOW AD I CEI 9'-0" ONCRI 0' 0' WALL SECTION 314 - I'-0" KEYED NOTES I. REFER TO ROOF PLAN SHEET A2.1 FOR ALL INFORMATION PERTAINING TO ROOF SYSTEM. 2. REFER TO STRUCT. DRAWINGS FOR FOOTING, FOUNDATION, FLOOR SLAB AND FRAMING CONSTRUCTION. 3. EXTRUDED ALUMINUM, STOREFRONT FRAMING. REFER TO EXTERIOR ELEVATIONS AND SPECIFICATION BOOK FOR INFORMATION. 4. MANUFACTURED STONE. SEE SPECIFICATION BOOK FOR MORE INFORMATION. INSTALL IN STRICT ACCORDANCE WITH ALL MANUFACTURER'S RECOMMENDATIONS AND TYPICAL DETAILS. 5. MANUFACTURED STONE WATERTABLE COURSE, BY SAME MANUFACTURER AS STONE VENEER BELOW. INSTALL IN STRICT ACCORDANCE WITH ALL MANUFACTURER'S RECOMMENDATIONS AND TYPICAL DETAILS. 6. J" EXPANSION MATERIAL AND SEALANT. 7. 2" RIGID, EXTRUDED POLYSTYRENE, PERIMETER INSULATION. 8. INTERIOR CAST IN PLACE CONCRETE SLAB ON GRANULAR FILL, REFER TO STRUCTURAL DRAWINGS FOR ALL CONSTRUCTION INFORMATION, 9. JAMES HARDIE SMOOTH FIBER CEMENT BOARD. 10. FINISHED GRADE VARIES. REFER TO SITE DRAWINGS. 11. 2X6 WOOD STUD FRAMED EXTERIOR WALL. SILL PLATE TO BE PRESSURE TREATED LUMBER SET ON SILL SEALER, TYPICAL. REFER TO STRUCTURAL DRAWINGS FOR CONNECTIONS, SHEAR WALLS, ETC... 12. EXTERIOR SHEATHING (REFER TO STRUCTURAL DWGS.) AND 1' CONTINUOUS RIGID INSULATION. PROVIDE MANUFACTURER'S JOINT TAPE ON RIGID INSULATION AND COVER WITH AIR INFILTRATION BARRIER. TAPE AIR BARRIER JOINTS. 13. J" GYPSUM BOARD SHEATHING OVER VAPOR BARRIER. 14. FILL ALL EXTERIOR WALLS WITH MINIMUM OF R-19 RATED BATTS OR BLOWN IN INSULATION. 15. PRE -FINISHED TEXTURE FINISH FIBER CEMENT PERFORATED SOFFIT MATERIAL. PROVIDE BLOCKING AS REQUIRED. 16. PRE -FINISHED 1X8 FIBER CEMENT TRIM WITH SMOOTH FINISH. 17. PRE -FINISHED 1X6 FIBER CEMENT TRIM WITH SMOOTH FINISH. 18. PREFINISHED METAL GUTTER, DOWNSPOUTS AND CAST IRON LEADER. TIE TO SUBSURFACE DRAINAGE. SIZING OF DOWNSPOUTS AND LEADERS TO BE DETERMINED BY FABRICATOR FOR CODE COMPLIANT RAIN WATER DRAINAGE COLLECTION. 19. SEALANT, TYPICAL. 20. PRE -FINISHED FLASHING. MATCH TRIM COLOR. 21. r GYP BOARD APPLIED TO UNDERSIDE OF TRUSSES. TAPE AND FLOAT ENTIRE SURFACE. PROVIDE LEVEL 5 FINISH AT LOCATIONS WHERE GYP BOARD WILL REMAIN EXPOSED. REFER TO CEILING PLAN FOR EXTENTS. 22, SUSPENDED ACOUSTICAL CEILING TILE AND GRID. REFER TO FINISH SCHEDULE FOR STYLE. 23, R-38 BATT OR BLOWN IN INSULATION, TYPICAL THROUGHOUT ATTIC SPACE. 24. INSULATION BAFFLES, TYPICAL EACH TRUSS BAY. 25. PRE -FINISHED 1X8 FIBER CEMENT TRIM WITH SMOOTH FINISH. 26, COORDINATE INSULATION EXTENTS WITH PRECAST MANUFACTURER AT TOP OF WALL. J" FAN FOLD INSULATION SHOWN TO EXTEND ABOVE ROOF LINE. 27. TYPICAL WALL PANELS: 9-3/4 OR 10 INCH THICK (MINIMUM R-12.1) INSULATED PRECAST CONCRETE PANELS WITH STEEL FORM PAINT READY EXTERIOR FINISH. 28. PRE -FINISHED FIBER CEMENT SOLID SMOOTH FINISH PORCH CEILING WITH BATTEN STRIPS AT 24" OC EACH WAY. 29. WRAP ROOF MEMBRANE UP WALL AND UNDER COPING. DO NOT USE TERMINATION BARS. 30. FOAM ENCLOSURE ENTIRE PERIMETER OF DECK. VERIFY MATERIAL AND DETAILS. COORDINATE WITH DECK MANUFACTURER/SUPPLIER. FOAM BETWEEN BLOCKING AND TOP LAYER ROOF INSULATION. EXTEND DOWN TO DECK AND JOIST ANGLES. SEE ROOF EDGE DETAILS ON ROOF PLAN. 31�yy11LJM IN FIBER CEMENT TRIM. REFER 1 0 6 N 13 FOR PLAN DETAIL. AND U UR AW IG OR SIZE AND ATTACHMENT. 32. SEE STRUCTURAL DRAWINGS, 33. TOP OF WALL/PARAPET 3 PART COPING. SEE ROOF PLAN FOR EXACT LOCATIONS AND DETAILS. 34. TYPICAL REVEAL. SEE DETAIL 11/A5.6. 35. FIBER CEMENT PANEL. 36. NOT USED. 37. LINE OF WALL BEYOND. 38. NOT USED. 39. JAMES HARDIE STAGGERED EDGE PANEL. 40. JAMES HARDIE SMOOTH FIBER CEMENT PANEL BEHIND OWNER PROVIDED SIGNAGE. 41. r GYPSUM BOARD SHEATHING. 42. NOT USED. 43. NOT USED. 44. NOT USED. 45. NOT USED. 46. NOT USED. 47. NOT USED. 48. PRE -FINISHED 2X10 FIBER CEMENT TRIM WITH SMOOTH FINISH. 49. PRE -FINISHED 1Xl2 FIBER CEMENT TRIM WITH SMOOTH FINISH. 50. PRE -FINISHED (2)2X12 FIBER CEMENT TRIM WITH SMOOTH FINISH. CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 IF :: 317. 288. 0753 ,.�,t,P pc�sr[iiro m'py., No. `y • AR19600043'. • STAR 0F _ THIS DRAWING AND THE IDEAS, DESIGNS AND CMCE TS CONTAINEDHEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITEC LIRE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CMSENT OF CURRAN ARCHITECTURE. Q CWMIGHT 2019. CURRAN MCHRECTURE PLAYSCHOOL AT LEGACY GYM ADDITION 14454 COMMUNITY DRIVE CARMEL, INDIANA 46032 REVIEW SET 1.16.18 BID SET '1.26.18 PERMIT S-T J2.04.19 zLADDENDUM DI 02.04.19 170299 WALL SECTIONS A592