HomeMy WebLinkAboutC3.1 - 190201TOPOGRAPHIC & BOUNDARY NOTE ALL EXISTING HORIZONTAL AND VERTICAL INFORMATION HAS BEEN SHOWN PER A TOPOGRAPHIC SURVEY, DATED 7/22/15 (JOB #: B36081) PREPARED BY MILLER SURVEYING, INC. CIVIL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF ACTUAL HORIZONTAL AND VERTICAL DATA IS DIFFERENT FROM THAT SHOWN ON THESE PLANS. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO COMMENCING WITH CONSTRUCTION. IIIIIIIIIIA FLOOD NOTE THIS LOT UES IN FLOOD HAZARD ZONE "X" AS SCALED FROM THE ROOD INSURANCE RATE MAP (FIRM) FOR HAMILTON COUNTY, INDIANA, COMMUNITY NAME CITY OF CARMEL COMMUNITY NUMBER 180081. MAP NUMBER 18057CO231 G, PANEL NUMBER 0231 G, DATED NOVEMBER 19, 2014. REFERENCE NFIP FIRM MAP #18057CO231 G EFFECTIVE DAIS NOVEMBER 19, 2014. GENERAL NOTES 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPUANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBIUTY TO FIELD VERIFY ALL UTUTY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. IT SHALL BE THE CONTRACTORS RESPONSIBUTY TO FIELD VERIFY ALL EXISTING ELEVATIONS BEFORE CONSTRUCTION BEGINS. GENERAL NOTES CONTRACTOR TO KEEP EXISTING PAVEMENT SURROUNDING THE SITE I.E. COMMUNITY DRIVE & EQUALITY BLVD. "BROOM CLEAN" AND FREE OF SOIL OR AGGREGATE THAT MIGHT BE BROUGHT OFF -SITE, DEPENDING ON THE CONSTRUCTION SEASON, MOISTURE CONTENT AND PROPERTIES OF THE SOILS ON SITE, CHEMICAL MODIFICATIONS AND/OR LIME STABILIZATION MAY BE REQUIRED. SEE SHEET C9.0 FOR SPECIFICATIONS. ALL CONCRETE PIPE JOINTS SHALL BE CONTINUOUS O-RING RUBBER GASKET CONFORMING TO ASTM C 443 CONTRACTOR (NOT THE PROJECT SITE OWNER) WILL BE RESPONSIBLE FOR THE DISPOSAL OF ANY SOIL, MATERIALS, ETC. NO OFF -SITE BORROWS OR STOCKPILES WILL BE NEEDED FOR THIS PROJECT. CONTRACTOR SHALL SUBMIT PRECAST STORM SEWER STRUCTURE SHOP DRAWINGS TO ENGINEER FOR REVIEW/APPROVAL PRIOR TO MANUFACTURING. PROFILE SCALE: 1" = 50' EXISTING RIGHT-OF-WAY NOTE DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. STORM SEWER INLET NOTE ALL STORM WATER INLETS & CATCH BASIN CASTINGS SHALL BE LABELLED WITH ENVIRONMENTAL MESSAGING "NO DUMPING, DRAINS TO STREAM" CAST IN RAISED OR RECESSED LETTERS AT A MIN. 1-INCH HEIGHT. A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS STORM SEWER SYSTEM NOTE ALL STORM SEWER INFRASTRUCTURE TO BE CONSTRUCTED WITH THE PROJECT LIMITS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE PLAY SCHOOL at LEGACY, INC. UTILITY LOCATE NOTE INDIANA 811 FAILED TO LOCATE ALL EXISTING UTILITIES ON AND/OR SURROUNDING THE SUBJECT SITE; THEREFORE, CONTRACTOR IS RESPONSIBLE TO LOCATE AND FIELD VERIFY ANY EXISTING UTILITIES BEFORE COMMENCING WITH CONSTRUCTION. CIWL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF THE PROPOSED IMPROVEMENTS INTERFERE WITH ANY EXISTING UTILITY 0' ANS. RELEASED FOR CONSTRUCTION Subject to compliance wHh all regulations of State and I Neal CIRI City of Carmel vVT`�1\w�L>aAAL DATE: \ 06/17/19 EXIST �755- - _- 9TORMMMx10LE.4w TC-TAI CURB I'AEi TO, - IRS E4 _ GN-FISTS -7R]TwNcONSI IN.=]IB6#(E%.1Y-61 1 .9n]nBRG9.w1 - �_ Mr -- 5 -- fi01 / oXSTIMCCWBINET �755 I TOI \y �J �� i \ _ 7 4 =]Wb(IX.tz. Hl _ - 6iOrd1MATXqE-<9 ITN.-]W1hteX5'-9) &B9Ts'a�m ( \'jPjf1 c P T 0 U 4 You#50" e-A&5)(15'RCP 91/' \ ( \= BRASS PLUG M. \600 it , Equality Blvd. DUEY. 754.es' O'1SIX 3y5%.y`yy4p;♦ \\ II I �La x j la LP>EXAVICP� � 11 REVISION RECORD REV DATE DESCRIPTION DES BY APP BY 1 08/08/18 REV. PER INITIAL REVIEW COMMENTS KPB BSC 2 02/01/19 ROOF DRAINS PER ARCHITECT REVISIONS BSC BSC �s=ia�s�2�2�+� � t'8 NORTH �j ill �������P► 4' lip rn PROPOSED LEARNING IN FEET ����1 EEI ��►► 1��1 GO ix III EXISTING SCHOOL BUILDING Fwue Snu,W x 1Y LF ✓e' 2.01 ACRES± OONNECTSTVCORAINTO ROGFORAINPRE LINE TO HE C�69NGSLAT ' \ \I \L.\J I \�•` 6• IX9 6 N.ET OCURBNETINUUNROLE Twf2- ROWNG `C / 7 �, s xP 8 Gar y- '.. M _ - 1 _ RF.E.=YaYO� ♦ \\ ]W;::(nwtwGnO.IwI _"I54 l 7544 .]9UBRCP. mvl PGG --� Im•.=r¢mOeRCP. sI \ 1 POP 'N xr.-]4 I 11 l M \ _ �_____ I D (1 1GG EXISTINGICURBINLET (RAISE Ex. CASHING ELEVATOR Y0 \ _ __ \ TO PROPOSED G>950 ` - ��--- \ --MLE ✓iB'RCP®03<% GUT>]59M EXI6TNGW'RCP \ �: ate wc. xl _ CONCRETE ENDSECTONVI ___ t (IX.1z.EL_-_ __ - RIRMP.6EE OEi& LAC]' =T4&Di(IX.10'.61 _ _ _ _ _ _ -752 _ H -] _ IHJ.- A& _ _ 5 TIN. -'J- _ _ __ _ __ ___ ------------------------- �------------------ ---746----- DETENTION SWALE WITH WHITE RIVER AT FLOOD STAGE �\ -(- - - IW 2-----------------------------------746_----100-YEAR BASE FLOOD ELEVATION= 752.00(NGVD 29 DATUM)- STORM PLAN-111=30' STORM SEWER PROFILE a "IIo tfF!Szl 0 ST 126' 114' 07 EX. 15' RCP 45 20.30% B0.23% III 57 745 80.24% IS' RLP 15' RLP 15' RCP 74rJ S' RCP Z SUMP REOD 10-YEA HGL CONNECT I2'PVC EXISTING FIRE SERVICE LINE TO BE LOWERED PER RAT ONAL ROOF DRAIN PIPE (CONTRACTOR TO FIELD VERIFY Q LOCATION/ELEVATION PRIOR TO COMMENCING SPREAD HEET 740 WITH CONSTRUCTION) 740 14+00 13+00 12+00 11+00 10+00 SCALE: HORZ.: 1 C=50' VERT.: 1 "=5' ` /Existing Now Grade 0 I � I v N I I I I I I 1BM /5295 BRASS PLUG F➢. 1 ELEV. =75111 ­ ST LEGEND: PROPERTY BOUNDARY I PROPOSED CONC RETE PAVEMENT I SEE DETAIL RET PROPOSED CONCRETE SIDEWALK PAVEMENT I E7S.35 PROPOSED SPOT ELEVATION I 880.17 PROPOSED CURB ELEVATION 879.67 ME MATCH EXISTING GRADE I TC TOP OF CURB/STORM CASTING ELEVATION BC BOTTOM OF CURB ELEVATION I FP EDGE OF PAVEMENT ELEVATION TW TOP OF WALL ELEVATION I W. STORM SEWER INVERT ELEVATION I =- - - - - - - PROPOSED GRADE BREAK 845 PROPOSED CONTOUR --847--- EXISTING COMOUR PROPOSED STORM SEWER PROPOSED ROOF DRAIN STORM SEWER ® ® PROPOSED STORM STRUCTURE 6T - % R6 APPROX. 135 LF OF 6" PVC (SDR35 01.0% MIN. SLOPE) ROOF DRAIN LEADER WITH RISERS. ADAPTERS FOR DOWNSPOUTS, BENDS, FITTINGS. & CLEAII Al ' ' BENDS > 22.5' FOR ROOF DOWNSPOUTS (TYPICAL) \ ®e APPROX. 60 LF OF S" PVC (SDR35 W.0% MIN. SLOPE) ROOF DRAIN LEADER W11H� / RISERS, ADAPTERS FOR DOWNSPOUTS, BENDS, FITTINGS ' 10 APPROX. 44 LF OF 10" PVC (SDR MIN. SLOPE) ROOF DRAIN LEADER VATIi RISERS. ADAPTERS FOR DOWNSPOUTS. BENDS. FITTINGS O DOWNSPOUTS, ` /E) APPROX. 112 LF OF 12" PVC (SDR35 01.0% MIN. SLOPE) ROOF DRAIN LEADER W11H RISERS, ADAPTERS FOR DOWNSPOUTS, BENDS, FITTINGS / 1e APPROX. 70 LF OF 18" PVC (SDR35 01.0% MIN. SLOPE) ROOF DRAIN \ LEADER WITH RISERS, ADAPTERS FOR DOWNSPOUTS, BENDS, FITTINGS / Ro BUILDING ROOF DRAIN. REFER TO ARCH. PLANS ' ' D CONNECT TO EXISTING ROOF DRAIN PIPE ®o 4 CONNECT EXISTING DOWNSPOUT TO NEW ROOF DRAIN PIPE //� !O TAPER CURB FLUSH WITH SIDEWALK ` ' CO B" ROOF DRAIN CLEAN OUT RISER/CAP CONTRACTOR NOTE NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. STRUCTURE DATA TABLE Structure Pipe Pipe Downstream Pipe Structure Top of Upstream Downstream Number Size (in) Length (it) Structure Materiel Type Casting Elev. Invert Invert 103 15 177 102 RCP 4'Diameter Manhole 754.50 749,07 748.63 102 1 15 114 101 RCP 4' Diameter Manhole 755.60 740.53 1 74827 101 18 126 100 RCP 4' Dia.Curb lnletMH 75325 748.1�4739 1" 18 48 E2 RCP 4'Dia.Curb lnletMH 752.50 747.69 747.57 E2 18 N/A N/A RCP Concrete End Section N/A 747.57 N/A NOTE STORM BACKFILL NOTE ALL PROPOSED RCP STORM SEWER SHOULD BE CONSTRUCTED WITH BACKFILL PER DETAIL NO. IG-31 ON SHEET C7.1 ALL CONCRETE PIPE JOINTS SHALL BE CONTINUOUS O-RING RUBBER GASKET CONFORMING TO ASTM C 443 18 " OF VERTICAL SEPARATION MUST BE MAINTAINED FOR ALL UTILITY CROSSINGS. STORM SEWER SYSTEM NOTE THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIRED AND AS APPROVED BY THE Ott OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS DEVIATONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR HELD APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION O ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES DENTED) AS GENERATNG VELOCITIES OF 2.5 fps OR LESS OR 10 fps OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS -BUILT CERTFICATON AT THE TIME OF CONSTRUCTION, PRIOR TO BACKHWNG THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS -BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPUANCE NTH THE DESIGN PLANS AND AS APPROVED BY TIIE CITY OF CARMEL UTILITY VALVE NOTE ALL UTILITY VALVES AFFECTED BY CONSTRUCTION SHALL BE ADJUSTED TO FINAL GRADE AS NEEDED TO BE FLUSH WITH FINISHED PAVEMENT, SIDEWALK OR LANDSCAPE AREA. a� 1 • 1 , Know what's below. Call before you dig. 0 U U T7 Z ao Fti O 0 A3 I•X•i W � z , � Cd�Q uJ ��z O44 Z0 -N v EGG CL M Ol z (CIO Loa 0ma UiU7U Z c n �l�na aEr)pq 0 5Go WE P, O .0 oZ �� E z y 3 o n x o E'" a V BOO i T N9 PE10910647 C - q : STATE OF DATE 06/22/2018 DWN BY: KPB CHKD.BY: BSC SCALE: 1" = 301` DATE: 06 22 18 1--A O W � O N /O >m F4 � P4 08 UQ� Z a Wz¢ Cd U W WW-I �qt qtU In 1 O 1-L'I F IL PROJECT NUMBER TPS.007 DRAWING NUMBER C3ml SHEET 5 OF 16