HomeMy WebLinkAboutS401 - 190204ABBREVIATIONS LIST
AR
ANCHOR RODS
LNTL
LINTEL
ABV
ABOVE
LSL
LONG SLOTTED HOLES
ACI
AMERICAN CONCRETE INSTITUTEONG
LONGITUDINAL
ADD'L
ADDITIONAL
LP
LOW POINT
All
ADHESIVE
LVL
LAMINATED VENEER LUMBER
ADJ
ADJACENT
MAS
MASONRY
AESS
ARCHITECTURALLY EXPOSED
MAT'L
MATERIAL
STRUCTURAL STEEL
MAX
MAXIMUM
AFF
ABOVE FINISHED FLOOR
MBM
METAL BUILDING MFR
AGGR
AGGREGATE
MCJ
MASONRY CONTROL JT
AHU
AIR HANDLING UNIT
MECH
MECHANICAL
AISC
AMERICAN INSTITUTE OF
MEZZ
MEZZANINE
STEEL CONSTRUCTION
MFR
MANUFACTURER
AISI
AMERICAN IRON AND
MIN
MINIMUM
STEEL INSTITUTE
MISC
MISCELLANEOUS
ALUM
ALUMINUM
MO
MASONRY OPENING
ALT
ALTERNATE
MOM
MOMENT
APPROX
APPROXIMATE
MSW
MASONRY SHEAR WALL
ARCH
ARCHITECT
MCI
MEAN SEA LEVEL
ARCH'L
ARCHITECTURAL
MTL
METAL
ASTM
AMERICAN SOCIETY OF
NO
NUMBER
TESTING MATERIALS
NS
NEARSIDE
AWS
AMERICAN WELDING SOCIETY
NTS
NOT TO SCALE
L
ANGLE
010
OUT TO OUT
BAL
BALANCE
CA
OVERALL
BB
BOND BEAM
OC
ON CENTER
BB
BACK TO BACK
OD
OUTSI DE DIAMETER
BC
BOTTOM CHORD
OF
OUTSIDE FACE
BD
BOARD
OH
OVERHEAD
BLDG
BUILDING
OPNG
OPENING
SICK
BLOCK
OPP
OPPOSITE
BLW
BELOW
OPP HD
OPPOSITE HAND
BM
BEAM
OSB
ORIENTED STRAND BOARD
BOTT
BOTTOM
OSL
OUTSTANDING LEG
BP
BEARING PLATE
OVS
OVERSIZE HOLE
BRDG
BRIDGING
PAF
POWDER ACTUATED FASTENER
BRG
BEARING
PC
PRECAST
BRK
BRICK
PL
PLATE
BS
BOTH SIDES
PLF
POUNDS PER LINEAR FOOT
BSMT
BASEMENT
PLYWD
PLYWOOD
BTWN
BETWEEN
PNL
PANEL
BUD
BUILT UP COLUMN
PROJ
PROJECTION
c
CAMBER
PSF
POUNDS PER SQUARE FOOT
GC
CENTER TO CENTER
PSI
POUNDS PER SQUARE INCH
CANT
CANTILEVER
PSL
PARALLEL STRAND LUMBER
CAIS
CAISSON
PT
PRESSURE TREATED
CFS
COLD FORMED STEEL
PTN
PARTITION
CJ
CONTROLANDIOR
R
RADIUS
CONSTRUCTION JOINT
RD
ROOF DRAIN
CL
CENTERLINE
REF
REFERENCE
CLR
CLEAR
REINF
REINFORCE(D) (ING) (MENT)
CMU
CONCRETE MASONRY UNIT
REQD
REQUIRED
COL
COLUMN
REV
REVISIONIREVISED
CHORD
COORDINATE
RO
ROUGH OPENING
COMP
COMPACTED
RRD
ROOF RELIEF DRAIN
LONG
CONCRETE
RTN
RETURN
CONN
CONNECTION
RTU
ROOF TOP UNIT
CONST
CONSTRUCTION
RW
RETAINING WALL
CONT
CONTINUOUS
SCHED
SCHEDULE
CONTR
CONTRACTOR
SECT
SECTION
CTR
CENTER
BHT
SHEET
CTRD
CENTERED
SIM
SIMILAR
CIA
DIAMETER
SJ
SAINCUT JOINT
DIAG
DIAGONAL
SJI
STEEL JOIST INSTITUTE
DIM
DIMENSION
SL
SLOPED
OL
DEAD LOAD
SPA
SPACE(S)
DLT
DEEP LEG TRACK
SPECS
SPECIFICATIONS
DO
DITTO
SQ
SQUARE
DN
DOWN
SS
STAINLESS STEEL
DTL
DETAIL
SSL
SHORT SLOTTED HOLES
DWG
DRAWING
STD
STANDARD
CWL
DOWEL
STIFF
STIFFENERS
EA
EACH
STL
STEEL
EE
EACH END
STRICT
STRUCTURAL
EF
EACHFACE
SYMM
SYMMETRICAL
EJ
EXPANSION JOINT
T&B
TOP AND BOTTOM
END
ENGINEER
T&G
TONGUE AND GROOVE
ELEV
ELEVATION
TB
TIE BEAM
ELECT
ELECTRICAL
TC
TOPCHORD
EOD
EDGE OF DECK
TCX
TOP CHORD EXTENSION
EOS
EDGE OF SLAB
TEMP
TEMPERATURE
EQ
EQUAL
TF
TRENCH FOOTING
EQUIV
EQUIVALENT
THK
THICK
ES
EACH SIDE
THKS
THICKENED SLAB
EW
EACH WAY
THRD
THREADED
EXIST
EXISTING
TL
TOTALLOAD
EXP
EXPANSION
TOP'G
TOPPING
EXT
EXTERIOR
TRANS
TRANSVERSE
FI
FACE OF
TYP
TYPICAL
FD
FLOOR DRAIN
UNO
UNLESS NOTED OTHERWISE
FDN
FOUNDATION
VERT VERTICAL
FIN
FINISH
VIF
VERIFYINFIELD
FUR
FLOOR
wl
WITH
FUG
FLANGE
WD
WOOD
FS
FARSIDE
WO
WINDOWOPENING(MASONRY)
FINE
FOOTING
WP
WORKING POINT
GA
GAUGE
VW
WEIGHT
GALV
GALVANIZED
WWF
WELDED WIRE FABRIC
GB
GRADE BEAM
GC
GENERAL CONTRACTOR
ELEVATION
TOP AND B070M OF LIST
GL
GLULAM
OR
GRADE
TI
'ELEVATION, TOP OF'
HC
HOLLOW CORE
BI
'ELEVATION, BOTTOM OF'
HD
HOLD DOWN
TIES
TOP OF BOND BEAM
HGT
HEIGHT
TIBM
TOP OF BEAM
HI
HIGH
TICONC
TOP OF CONCRETE
HK
HOOK
TIF
TOP OF FOOTING
HORIZ
HORIZONTAL
TILDE
TOP OF LEDGE
HP
HIGH POINT
TIMPS
TOP OF MASONRY
HS
HEADED STUD
TIP
TOP OF PIER
HSS
HOLLOW STRUCTURAL SECTIONTBLAB
TOP OF SLAB
ID
INSIDE DIAMETER
TBTL
TOP OF STEEL
IF
INSIDE FACE
TAW
TOP OF WALL
INFO
INFORMATION
TIBB
TOP OF GRADE BEAM
INT
INTERIOR
TICAIS
TOP OF CAISSON
INV
INVERT
ERIC
BOTTOM OF PLATE
JST
JOIST
BIF
BOTTOM OF FOOTING
JT
JOINT
K
KIP
SPECIAL CHARACTERS
KO
KNOCKOUT
LB
POUND
DEGREE
LDG
LEDGE
t
PLUS OR MINUS
LG
LONG
ELEVATION
LL
LIVE LOAD
0
DIAMETER
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
SPK1. 'Support'= Hangers, brackets, etc ."Structure'= Building structure indicated on tlrawings.
SPK2, It is the contractors responsibility to inform McComas Engineering of all sprinkler support locations, if not indicated on drawings,
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel
DATE: 06/17/19
MD7, All metal deck material, fabrication and installation shall conform to Steel Deck Institute
'SDI SPECIFICATIONS AND COMMENTARY' and'CODE OF RECOMMENDED
STANDARD PRACTICE', Current edition, unless noted.
MD2, FASTENING DECK
1. Roof deck shall be welded using 5B' diameter puddle were, 3614 pattern with (1) #
10 TEK sidelap fastener unless otherwise shown in typical detail or indicated on
drawings,
2. Floor deck shall be welded using N' diameter cuddle welds, 3614 pattern unless
otherwise shown in typical detail or indicated on drawings
MW. Provide TS 212x 212x 118 deck support, field welded to joist or beam at all deck span
changes.
MCA. Provide L3x3xll4 deck support at all columns where required, unless noted.
MD5, Provide 20 gauge cover plate at all roof deck span changes.
MOB. ProvideL3x3x114 at all unsupported etlges of deck and around roof perimeter, unless
otherwise noted.
MW. All deck shall be provided in a minimum of 3-span lengths where possible.
PIA1. Except where indicated on the drawings, post -installed anchors shall consist of the Following anchor types.
PIA2 Anchorage to concrete
a. Adhesive anchors for cracked and uncracked concrete use:
i. Hilti hit -fry 200 safe set system with the hiiti hit-z rod per icc esr-3707
ii. Hill hit-hy 200 safe set system with hilt hollow drill bit (teed or teyd) and vc 150800 vacuum (vc 150 or vc 300) system with hose threaded rod per icc esr-3187
iii. Hit hit -re 500 0 safe set system with hilti hollow drill bit Qectl or te-ytl) and vc 15CIWC vacuum (vc 150 or vc 300) with hose threaded had per icc esr-3814
iv, Hilti hit -re 500 v3 safe set system with hiiti roughening tool de-yrt) with hale threaded rod per icc esrd814 for diamond cored holes,
h Medium duty mechanical anchors for cracked and moral concrete use:
i. Hilti kwik bus ez and kw bus ez-1 screw anchors per icc esr$027
ii. Hilti kwik boh-tz expansion anchors per icc esr-1917
iii. Hilti kwik not 3 expansion anchors Uncricked concrete only) per icc esr-2302
c. Heavy duty mechanical anchors for cracked and uncacked concrete use:
i. Hilti as undercut anchors per icc ear 1546
ii. Hill hi expansion anchors per icc esr 1545
d, Reber doweling into concrete
i. Adhesive anchors for cracked and uorracked concrete use:
1. Hilt hit -fry 200 safe set system w o hilt i hollow drill bit (tecd or to-yrt) and vc 1501300 vacuum (W 150 or vc 300) system with continuously deformed most per icc esr-3107
2. Hilt hit-hy 500 v3 safe set system with hiiti hollow drill bit (tecd or a-yd) and vc 15NMO vacuum (vc 1SO or vc 300) system w o continuously deformed saber per icc esr-3814
3. Hilt hit -re 500 v3 safe set system with hilt i roughening tool de-yrt) with continuously deformed rebar per icc esr-3074 in diamond cored holes
e. Anchorage to Sol id grouted masonry
i. Adhesive anchors use:
1. HIL hit -fry 70 masonry adhesive anchoring system (icc pending).
2. Steel anchor element shall be hilt i hose continuously threaded rod or continuously deformed steel radar
ii. Mechanical anchors use:
1. Hilt kwik bolt-3 expansion anchors per icc Sir 1385
f. Anchorage to hollow I multi-wythe masonry
i. Adhesive anchors use:
1. Hilt hit-hy 70 masonry adhesive anchoring system per icc esr-Ko12.
2. Steel anchor element shall be hiiti hose continuously threaded had or continuously deformed steel rebar
3. The appropriate size screen Woe shall be used per adhesive manufacturers recommendation
061000 SAWN LUMBER NOTES
Wf. Size,species and grade for sawn lumber shall be as follows. Al l lumber shall be gradesfamped:
Design Design Aternate Alternate
Size Species Grade Species Grade
2x4, 2x6 Spruce -Pine-Fir(SPF) No.1/No.2 Douglas Fir-Larch(North) No.1/No.2
2x0, 2x10, 2xl2 Southern Pine (SP) No. 1 Douglas Fir -Larch No & Better
4x4 and Larger Southern Pine (SP) No. 1 Douglas Fir -Larch No & Better
W2. All mod, connections accessones, and erection shall be in conformance with the current edition of NFPA National
Design Specification.
W3. All connectors shall be Simpson Strung-Tie,galvanized, unless otherwise approved by the Engineer of Record.
MIS All Potts, washers and nms shall be carbon steel, unless noted.
Wis. All nails to be common type.
W16. All sill plates shall be treated with preservative treatment.
W7. All exterior lumber permanently exposed to weather shall be pressure -treated,
WB. Attach all sill plates to studs with (4) Bd common nails (toenail) or (2)16d common nails (end nail).
WS Attach all top plates to studs with (2)16d nails.
W10. Comply with International Building Cape Table 2304.9. 1 for all fasteners not indicated,
Wf 1. See Wood Framed Wall Schedule and Shear Wall Schedule for additional fastening requirements.
W12. Piece double gists under all drill bearing walls.
W13. Provide double lists and headers at all floor or roof openings exceed ing typical sheathing span. Provide single
headers to support sheathing at edges of openings less than typical sheathing span.
061101 ENGINEERED WOOD NOTES
EWi. All manufactured engineered mod listed as been designed using product data from Weyerhaeuser Corporation.
Engineered wood members supplied by other manufacturers shal I meet or exceed the criteria for the
designated Weyerhaeuser CDmDb ion product for the span,spacing, and loads indicated in the construction
documents.
EW2, All properties listed are for dry -use conditlons
EW3. All connectors shall be manufacturer by Simpson Scrol ie Company.
EW4. Contractor shall provide a complete installation of Manufactured engineered wood members, including but
not limited to, all blocking, stiffeners, and similar items,
EW5. Manufacturer engi neered mind shall be designed by the supplier to meet the project requirements indicated
in the constructor documents. Layout and design of members shall be signed and sealed by an Engineer
licensed to practice in the project state, and submitted to the Engineer of Record for review.
EW6. All engineered mod shall be commercial grade.
EMO All engineered mod permanently exposed to weather shall be pressure -treated, coated or sealed. Comply with
manufactures recommendations.
LVL7. Manufactured Laminated Veneer Lumber designated as LVL shall be supplied with the following minimum
material propertiesfor 12'depths:
Extreme Fiber Stress in Bending, Edgewise: 2,600 psi
Extreme Fiber Stress in Shear, Horizontal: 285 psi
Modulus of Elasticity, Edgewise: 1,900,000 psi
PSL7. Manufactured Parallel Strand Lumber designated as PSL shall be supplied with the following minimum
material properties, for 12'depths:
Extreme Fiber Stress in Bending, Edgewise: 2,900 psi (Beam - 2.0E Parallam PSL)
Extreme Fiber Stress in Bending, Edgewise: 2,400 psi (Column -1.BE Parallam PSL)
Modulus of Elasticity, Edgewise: 2,000,000 psi (Beam 2.LEI
Modulus of Elasticity, Edgewise: 1,800,000 psi (Column 1 BE)
Extreme Fiber Stress in Shear, Horizontal: 290 psi (Beam)
PSL2. For all PSL members permanently or partially exposed to exterior conditions, provide the fullmving:
PSL Parallam Plus Service Level SL2 AWPA Use Category UC33
OWN Manufactured Word Open Web Trusses designated as Open Web Trusses shall be supplied to meet the minimum
loading and depth requirements as indicated on the drawings, and the following:
Floor Maximum Total Deflection Span 1360
Floor Maximum Live Deflection Span 1480
Roof Maximum Total Deflection Span 1240
Roof Maximum Live Deflection Span 1360
WTI. Shop -fabricated, meat-plate-conneetl wood roof trusses shall be assigned for the following gravity loads
(allowable stress design), in addition to other loads indicated:
Top Chord Dead & Top Chord Live See General Notes
Bottom Chord Dead 10 psf (Local Load, not added to Top Chord)
Wind: Net Uplift 15 psf
Wind: On End Verticals 20 psf
WT2. All bolts, washers and nuts shall be carbon steel.
WT3. All trusses connector plates shall be galvanized.
WT4. All trusses shall be soared at 24' o. c., unless noted otherwise.
WTS. All standard, hip, valley,scissor, girder and other misttrusses a ad supplemental roof framing not shown,
shall be designed and provided by the truss manufacturer and contractor. Truss manufacturer and
contractor shall be responsible for the final truss layout.
WT6. All truss layouts, profiles and configurations are conceptual Final layout and design shall be by truss
manufacWrensupplier.
MIT . Girder truss design load ing shall take into account add rural concentrated loads from other trusses.
WTO, See architectural drawings for actual I mansions, roof overhangs, fascia heigfah, etc
WT9. All connectors shall be Simpson Strong -Tie Company, galvanized . All connectors not shown on d rawings
shall be tlesignetl by the truss manufacturer, except the following:
Truss Wood to Wood Connections'.
End of Single Truss to Double Top Plate: Al (5451b uplift 1351b shear)
End of girder truss to perpendicular top plate: LGT2 2 ply girder truss(20501 b uplift)
LGT3-SDS2,5 3-ply girder truss(3605b uplift)
LGT4-SD53 4-ply girder truss(40601b uplift)
End of girder truss to non -perpendicular top plate: MST12 Each side of girder truss
Truss Wood to Masonry Connections:
End of Single Girder Truss to Double Top Plate: Hi6-28(14701b uplift, Provide additional tiedowns it
truss is wider than 3')
033000 CAST IN PLACE CONCRETE NOTES (Foundations. Slabs. &Walls
RCi. All concrete shall have the following 28 day compressive strengths
STRENGTH LOCATION
3000 psi-C%AE All foundations and footings
4000 psi6%AE Exterior slabs, piers, walls, columns, grade beams and concrete exposed to freezing
4000 psi-C%AE Interior slabs, fill for metal deck and all other interior concrete
RC2, All reinforcing shall conform to the following concrete cover:
COVER LOCATION
3' Foundations &Footings: All surfaces; Exterior Slabs: Bottom; Grade Beams &Trench
Footings: All surfaces; All concrete cast against mil
2' Exterior Walls, All Piers&All Pilasters: All surfaces; Exterior Slabs: Top; All extedor concrete
1112' Interior beams, columns & walls: All surfaces; All concrete not exposed to weather or in
contact with ground
314' Interior slabs &Walls
RC3. Welded Wire FabrL(WWF) for slabs and fill for metal deck shall be placed in the upper -third of the slab or fill See
details
RC4. All reinforcing steel shall be detailed, supplied and placed in accordance wAth ACI 315, ACI 318 and CRSI Mi
RC5. All reinforcing steel shall be shop ISbricated and, where applicable, shall be wiretl together and conform an ASTM
A-615, Grade60.
RCS. Cha rater edges of exposed concrete 3l4', unless noted otherwise.
RC7. Contractor shall make four,6'k12' test cylinders for each W cubic yards of concrete poured for each days
operation. Break 1 at 7 days, 2 at 20 days and retain spare
Fact All welded wire fabric shall conform an ASTM A185, Fy(min) of 65 ksi. All welded wire hard laps shall be 8'.
RC9. All finished concrete, concrete formwork and ftsework shall be in accordance with ACI 301. Contactor is solely
responsible for the design and constructor of all formwork, falsework and shoring,
RC70. Providesleeves for all openings in gradebeams or walls to totally separate pipe from concrete.
RC11. Foundations may be earth -formed where the excavation permits. If eaM-forming is used, add 2' to the width,
length & thickness of all foundations.
RC12. Plastic Vapor Better'. ASTM E 1745, Class A, not less than 10 mils C Z mm) thick, see specifications. Include
manufacturer's recommended adhesive or pressure -sensitive joint tape.
RC13, Fiber Reinforcement, if indicated on drawings, shall be 100% Nrgin polypropylene in collated, fibrillated form,
complying with ASTM C 1116, minimum length of 3I4". Minimum tlosage =1.5 pounds per cubic yard.
RC14. Adhesive Anchors and Adhesives Used for Reinforcing Anchorage:
1, The adhesive anchor system used for post -installed anchorage to concrete shall conform to the
requirements of the most recently published ACI 355.4.
2. Adhesive anchors indicated are the Basis -of -Design. Approved equal meeting ACI 355.4 is permitted.
3. Bulk -mixed adhesives are not permitted.
4. Anchors shall be supplied as an entire system with manufacturers recommendations adhered to.
5. Adhesive anchors shall be Installed by qualified personnel Tined to install adhesive anchors.
6. Installation of adhesive anchors horizontally or upwardly inclined shall be performed by personnel
cors ed by the ACIICRSI Adhesive Anchor Installer Certification program.
7. Adhesive anchors installed in horizontal or upwardly inclined orientations shall be continuously inspected
during installation by an inspector specially approved for that purpose.
RC15. Bonding agent for bonding fresh concrete to hardened concrete: ASTM C 105WC 1 C59M, Type 11,
nomedispersible, acrylic emulsion or styrene bummers
PC7, Delegated Design: A Specurty StrucOral Engineer (SSE), reglatered In the state of the project, shall be
responsible for the structural
design of all precast concrete design, products and systems complying with specific performance and design
I indicated.
PC1. The minimum 28 day compressive strength of all precast elements shall be 5000 psi.
PC2. Soo architectural drawings for all architectural finishes, textures, reveals, etc. All embeds may not be indicated
on structural drawings, See other trade drawings for required embeds,
PC3. Coordinate with Architectural, Mechanical, Electrical, Plumbing, Cosl plans for openings and penetrations to be
cast into precast elements.
PC4. The layout and arrangement of all precast elements is schematic in nature and is intended to show the scope of
the precast system. The precast manufldureris responsible for the final layout, size, spacing etcof all
precast elements and connections.
PC5. Precast connections shown are schematic in nature. Final detail and design is the responsibility of the precast
manufacturer.
PC6. The precast manufacturer or erector is responsible for all temporary bracing that may be required until the
lateral load resisting systems for the building are complete and has attained their design capacity.
PC7. All precast elements shall be capable of supporting their win weight as well as specified loadings and reactions
indicated,
PCB. If applicable, camber all beam elements per PCI standards.
PC9. HOLLOW CORE PLANK
1. Hollow core planks shall be designed for non -composite interaction with appall
2. Nominal width of planks shall be 4'-C'typical.
3. Manufacturer shall revew structural support conditions and report any requested modifications for supports
or restraints to the FOR prior to submiWng HCP shop drawings,
4. Manufacturer is an pri bearing pads for HCP on structure.
M1. Mini mum 28 day compressive strength of concrete masonry units shall be 2800 p a i. based on net area
of the unit. Specified design compressive strength of masonry shall be Pm=2000 p.s.l. All units for
exterior walls, (cad -bearing walls and shear walls shall be normal weight black.
M2. All mortar shall be Type S. No admixtures may used unless approved by architectlengi near. Mortar shall
not be used for grouting cores or filling bond beams.
MIS All block shall be laid in a running bond patter.
M4. Course grout shall be used were grouting is required. Slump shall be V N- 1'. Minimum grout
compressive strength shall be 3000 psi,
M5. All reinforcing shall be ASTM A615 Grade 60 (Fy-60 ksi). Lap all nenforang a minimum of 48 bar
diameters.
M6, Center vertical reinforcing in block cores, unless noted otherwise,
M7. See achitectural and specifications for all control joint locations. Reinforcing in bond beams shall be
discontinuous at control lints.
M0, Provide ladder type horizontal joint reinforcement at 16"o,o. Side rods and cross rods shall be#9 wire,
galvanized,see specifications. Cut joint reinforcement at control joints.
M9. Pravda 1bars at all bond beam corners as required.
M70, Fill cores of black solid with grout two full courses below the ban nng of all beams or lintels supported on
masonry.
M71. All attachments to block shall be made with Hilt HLC 12"diameter x Y sleeve anchors, unless noted
otherwise. Anchors shall be installed per manufacturers recommendations.
M12. See typal schedules for masonry and steel lintels not indicated on plans.
M13, All masonry units below grade to be grouted solid.
M14, Pmvide ties to all structural steel,
M15. All intetlor,non -load bearing masonry walls war 12'-0'high, shall be supported on thickened slab as per
typical detail. Wall vertical reinforcing shall be #5 @ 48" OC full height. Unless noted otherwise.
M16. All cores Loth reinforcing steel shall be grated solid, full height of wall.
051200 STRUCTURAL STEEL NOTES
551. All structural steel shall conform to the following:
W Shapes ASTM A992, Grade 50.
Angles, Channels, Plates, Bare ASTM A36 (Fy-36 ks)
HISS Tubes ASTM A500, Grade B (Fy=46 ksi)
HSS Pipes ASTM AMC, Grade B (Fy-42 ksi)
Anchor Rods ASTM F1554, Grade 36
SS2. All steel shall be detailed, fabricated and erected in accordance with:
AISC 360'Speofication for Structural Steel Buildings', Allowable Strength Design (ASD)
AISC 303 "Code of Standard Practice"
SS3. If beam reaction is not indicated, tlesign connection for minimum 10 k reaction.
SS4 All bolted connections shall be made with 3W diameter, A325 bolts with nuts and washers, unless otherwise noted.
All connections shall be shear beanng connections tightened to snug -fig fat condition, unless otherwise noted,
SS5. All shop and field were shall be made using E70 electrodes or equivalent.
SS6. All headed concrete anchors shall be ASTM At 08(Fy=Wkd), 3W diameter 4" after welding, unless noted
otherwise,
SS7. Steel fabricator shall obain the size and location of all openings for gales, covers, etcbefore proceeding with the
fabrication and erection of any required fames.
SSO, PmvideHeckman #129 and#130 channel slot and channel slot anchors at all columns that abut masonry walls,
unless noted
SS9. Provide temporary bracing of the structure until all permanent lateral support is in place.
SS70, Structure Stability: The entire roof and/or floor decking materials must be fully erected and connected to the
supporting steel before temporary, erection bral is removed
SS71. RD= Roof Drain location. Provide steel fame Bur . See other drawings for actual drain type, number, size,
etc. Coordinate with drain control
SJI. Provide all joists, bridging and accessories for the complete erection of joists in accordance with the current
Steel Joist Institute'STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS
AND JOIST GIRDERS"and Undemdters Laboratories "STANDARD, FIRE TESTS OF BUILDING
CONSTRUCTION AND MATERIALS'.
SJ2. Bridging shall be completely erected and lists aligned before any construction leads are placed on joists.
SJ3. Do not weld bottom chord of joists to columns unless noted on drawings.
SJ4. Install erection bolts at all joist girder to column and joist an column connections.
SJ5. Where ballasted roofing is not shown on architectural drawings, provide uplift bridging at all joists as per
"STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST
GIRDERS' for a net uplift load of 20 psf, unless noted or shown otherwise.
GENERAL NOTES
DESIGN TABLE
Model Building Code.
312 International Building Code
Local Building Cade:
Indiana Building Cade 2014
Model Code Standard.
ASCE 7-10
Steel Standard
AISC 360-10 ASD
Steel Seismic Standard:
AISC 341-10 ASD
Concrete Standard
ACI 319-11
Masonry Standard:
ACI 530-11
Wood Standard:
AITGAPAINDS Current Ed.
Risk Category:
II Normal Risk
ROOF DESIGN LOADS
Dead Live Snow
Main
a3.0 psf a3.0 psf 20.0 psf
Gym
20.0 psf 20.0 psf 20.0 psf
FLOOR DESIGN LOADS
Dead Live Paoton
Floor
67.0 psf
SOILS
Spread Wall
Allowable Bearing Pressure, qa:
2000 psf 2000 psf
Sod Density, yC
120 par
Minimum Foundation Bearing Depth:
N in
SLAB ON GRADE
Computed Fill Thickness:
6 in
Compaction Specification:
95% Modified Proctor D-1557
SNOW DESIGN CRITERIA
Ground Snow Load, Pic
20 psf
Flat Roof Snow Lead, Pf:
2ll psf
Importance Factor, Is:
1.0
Exposure Factor, Ce:
1,0 Partially
Thermal Factor, CC
1.0 Heated
Warm Slope Factor, Cs:
1.0
WIND DESIGN CRITERIA
Ultimate Wind Speed, VulC
115 mph
Design Wind Speed, VASD:
90 mph
Enclosure Class:
Enclosed
Internal Pressure Coeffiuent, EDE:
D.10
SEISMIC DESIGN CRITERIA
Importance Factor, IS:
100
Mapped Spectral Response, SS:
0.187
Mapped Spectral Response, S1:
0.091
Site Class:
D
Design Spectral Response, SOS:
0.199
Design Spectral Response, SDI:
0.130
Seismic Design Category, SDG
B
Overstrength Factor, 0:
3
Seismic Response Coeffiaent, CS:
0.031
Response Modification Coeff., R:
6.5
Unfachred Design Base Shear, V:
3.1% W
Analysis Procedure:
ELFA
Basic Seismic -Force -Resisting System:
A. Bearing Wall Systems
15. Light -frame (wood) walls sheathed with wood structural panels rated for shear resistance
G0. Reactions and forces indicated are unfactored, Allowable Strength Design( ASD) leads.
09. If Drawings and speafications
are in conflict, the most stringent restrictions and requirements shall govern. Contractor shall bring all
discrepan res to the attention
of the engineer immediately.
G10. Verity all existing conditions prior
to any construction or fabricator If different than shown, notify engineerlarohitect immediately for
modification of tlrawings.
Bit All contradors are required to
coordinate their work with all disciplines to amid conflicts. The architectural, mechanical, electrical and
plumbing aspects are not in the
scope of these drawings, Therefore, all required materials and work may not be indicated, It is the
contractor's responsibility to coordinate these drawings with all other construction documents. Refer to architectural drawings for all
dimensions not shown on these drawings. Locations, sizes and numbers of all openings may not be completely indicated in the
structural drawings. The respective contractor shall verify their work with all other disciplines,
G12. The contract documents represent the structure only. They do not indicate the method of construction. The contractor shall provide all
measures necessary to protect the structure during construction. Such measures shall include, but not limited tobracing, shoring,
underpinning, eta, the Engineer Of Record Is not responsible for the contractors means, methods, techniques, sequences Or safety
proced Loss during construction.
G13. Notes and details shall take precedence
over general structural notes. Where no details or sectors are shown, construction shall
conform to similar work on the project Typical sectlons and details may not be cut on the plans, but apply unless noted otherwise,
G14. Provisions for Wture expansion'.
Vertical: None
Horizontal: None
ES1, The actual existing structure configuration, member sizes, eta has not been field verified,
ES2. All existing structure indicated is for reference only.
ES3. Field verity existing structureif existing structure varies tram configuration,sizes, etc from drawings, notify engineer of record immediately.
014000 DELEGATED DESIGN
SSE1. A Specialty Structural Engineer (SSE), red !stereo In the state of the project, shall be responsible for the structural
design of the following products and systems complying with specific performance and design criteria indicated,
1. Steel Joists, joist gliders, bridging and accessories.
2, Structural Steel Connections, except as shown on drawings.
AISC Option 2 (Oetailerr Simple shear connections.
AISC Option 3 (SSE): All other connections not shown.
3, Shop Fabricated Woad trusses, wood girders, woad bracing and accessories,
4. Precast Pres ossed Concrete elements and accessories.
020000 SHALLOW FOUNDATION AND SLAB ON GRADE NOTES
SF1. Soil an be stripped, compacted and tested in accordance with the recommendations of the soils engineer and
project speclfcatons.
SF2. Footings shall beplaced on film, undisturbed soil or on engineered fill. Engineered Fill: Naturallyorahifiaally
graded mixture of all or crashed gravel, crashed stone, and natural or crushed sand, ASTM D 2940; with
at least 90 percent passing a 1-1/2-inch sieve and not more than 12 percent passing a No, 200 sieve,
SF3. Slabs shall be placed on compacted, freedraining,frost-free drainage course. Drainage Course:Narrowly
graded mixture of washer crashed stone, or crushed or uncrushed gavel'. ASTM D 448; crime aggregate
grading Size 57; with 100 percent passing a 1-1l2-inch sieve and 0 to 5 percent passing a No Sears Alfill
shall be compacted to a minimum dry density of 95% of the modified Proctor maximum dry density (ASTM-
D1557). placed in 6" to 8' lifts. Pea gavel may not be used as fill. Utility trenches and excavations under the
foundations or slats shall meet the same requirements, See soils investigator report for further
recommendations.
SF4. Undercutting of the soil for foundation and/or slab placement may be required. These drawings do not indicate
the entire scope of undercutting, fill or bad soil removal that may be required to attain the design soil beating
pressures. It is the responsibility of the contractor to obtain a soils investigation report, before bidding, to
assess the extent of excavation and compaction that may be required to meet the design criteria. The
contractor shall retain the services of a soils engineer to monitor all backfilling operations and to inspect
footing bearing material. A report certified by the soils engineer shall be furnished to the architectlengineer
vedtying that all foundations were placed on a material capable of sustaining the design bearing pressures.
SF5. If dewatering is required, sumps shall not be placed within the foundation excavation
SF6. Maintain a maximum slope between adjacent footing bearing elevations of 2 horizontal to l vertical Maintain
2 honz00tal to 1 vertical slope not to existing foundations t0 avoid undermining foundations.
SF7, No horizontal joints are permitted in any foundation. Vertical joints are permitted only in wall footings,
SFB. Shallow foundamns may be eaM-formed where the excavation permitsif earth -forming is used, add 2'h the
width and length of all foundations.
SF9. The bottom of all foundations shad l be a minimum of local frost depth below final grade.
CURRAN
ARCRITEOTRRE
6925 EAST 96TH ST., SUITE 105
INDIANAPOLIS, IN 46250
O :: 317. 288. 0681
F :: 317. 288. 0753
McCOMAS
ENGINEERING
Structural Engineers
1717 East 1 l6th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
Www,mccomaseng.com
MEI 18263
No.
860325
STATE Be
THIS DRAWING AND THE IDEAS. DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUCAL
PFC>P Y OF CURRAN ARCHITECTURE.
AND ^RF NOT TO BE USED OR
REPRCIT) O. WHOLE OR IN PART.
WrHOLIT T N CONSFNT DF
CURRAN ARCHITECTUi
c®PrRICFIT 2013. cLri .sac HITECTURE
PROJECT INFORMP
PLAYSCHOOL
A-F LEGACY
GYM ADDITION
14454 COMMUNITY DRIVE
CARMEL, INDIANA 46032
REVIEW SET
11.16.18
BID SET
11,26.18
PERMIT SET
02.04.19
S401
18263-MEI