Loading...
HomeMy WebLinkAboutE3.2 - 190204RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Central �VT�tBwRCNWA� DATE: \ 06/17/19 ELECTRICAL ROOF PLAN Note: E.C. shall comply with the IBC in regards to fire rated membrane penetrations. Utilize means of fire rated junction boxes, "putty pi fire blocking and offsetting. General Notes: A. All 120 volt, 20 amp dreuits over 60' in length shall be #10 AWG, over 95' shall be 48, over 145'shall be 46. B. Contractor shall coordinate with all other trades to avoid conflicts of space. C. Contractor shall coordinate the exact location of all devices with all other trades prior to rough -in. Exact location to be determined in the field. D. Contractor shall coordinate with the mechanical and plumbing contractors for exact locations of equipment prior to rough -in. E. Refer to sheet E7.1 for details and symbols. F. Refer to sheet E6.1 electricalnserciagram. G. Refer to sheet E6.1 and E6.2 for electrical schedule(s). H. Shared neutrals shall not be Permitted. J. Note"H' clips are not acceptable for junction box supporting. K. Switches shall be a maximum +48" A.F.F. to the top of the device unless Otherwise noted. L. Receptacles, telephone outlets, and television outlets shall be a minimum of ♦16' A.F.F. to the bottom of the device unless Otherwise noted. M. Where devices are installed in fire walls, the boxes shall be rated and sealed for installation in a fire wall. N. Provide HACR circuit beakers for all HVAC and refrigeration equipment. P. No conduit to be supported from the roof deck. Plan Notes: OProvide umbilical power connection from extedor and on roof to interior associated unit. Coortlinate with HVAC Contractor for final connection. Circuit to have no more than 3%voltage drop. 146TH STREET i c PROJECT" LOCATION KEY PLAN CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317. 288. 0681 F :: 317. 288.0753 GOS,LA%ORq 1.1 $G p F ti w _ 14 x 10 STATE OF THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIMNTI LLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. � CWWJCM 301$QIRP4N ARCMTERINf PLAYSCHOOL AT LEGACY GYM ADDITION 14454 COMMUNITY DRIVE CARMEL, INDIANA 46032 REVIEW SET 11.16.18 BID SET 11.26.18 PERMIT SET 02.04.19 1 ADDENDUM 01 02.04.19 170299 ELECTRICAL ROOF PLAN E392