HomeMy WebLinkAboutM7.1 - 190204Low pressure supply branch duct Provide shoe B" Min. / tP fitting Collar with manual volume damper 8 lock ` Insulated flexible duct to Supply diffuser Notes: Provide a 45 degree entry square -to -round fitting from low pressure supply branch duct when the supply diffuser branch size equals or exceeds the depth of the Supply branch tluct. Width shall equal round diffuser branch size, depth shall equal Supply branch duct depth. Refer to supply diffuser plenum connection detail if guidelines of this detail can not be met due to physical limitations. A maximum length of 5'-W of flexible duct is allowed in a single run. Sheet metal box Secure flexible duct to supply diffuser elbow fining with drawband 1-1IT duct wrap Lay -in panel where required ` 12" x 12" diffuser Ceiling Nylon snE 3" 1 Raw Insulated flexible duct to supply diffuser Supply diffuser J Application NOT Acceptable Secure flexible duct to supply diffuser elbow fitting with drawband Sheet metal elbow 1-1/Y tluct wrap _T 24" x 24" diffuser J r Diffuser and Flexible Duct Connection Cable support as required Supplied by contractor Refer to Fabric Duct Cable Detail oar slot position gm as specitietl `Inlet collar, ductbuckle for attachment andzipper for easy detachment D ] Fabric Duct - Single Cable M].1 Scale: None 12' wide � capper strap stractu hanger to Wilding structure Insulation like Armaflex, continuous t ru hangar Ceiling /_ Refrigerant pipe Install minimh insulation um liquid line ° E Refrigerant Piping Support RELEASED FOR CONSTRUCTION M].1 Scale: None Subject to compliance with all regulafims of State and Inca) Codes e City of Carmel (� �{Vml�ilLixL DATE: \ 06/17/19 Hood or fan Unit counterflashi ng flange Wood nailer 21/2" by curb MFR 1AT Mick semi -rigid insulation 14" Cant strip by curb MFR Roof membrane Root insulaton Blocking to level curb (rewired Metal root deck for curbs over 2P on a side) D 5 Exhaust Roof Curb Section M].1 Scale: None 1 1IT thick 31b. density Continuous welded corners - Notes: 1. Curb typical for exhaust fans, relief hoods, and rooftop unit. 2. Roof openings shall conform to manufacturer's curb size. 3. Coordinate root openings with structural framing. D 4 Exhaust Roof Curb MZ1 Scale: None Neoprene weatherseal - 4"flexible duct connection between root Rooftop Unit insulation and bottom of rooftop unit Curb by RTU MFR unless specitietl otherwise �I /Wootl nailer Countedlashing� v _ _ Field applied cant strip Supply and return ducts Roof construction. Refer to Treated 2x4 shimming architectural drawings for type to level top of curb Root structure, Rater to structural drawings for type Full perimeter curb supports Provide 90-elbow to I transdion to horizontal. Do 1 L not provide a duct plenum antl\\ horizontal tap. IT a 90- elbow alimpractical, coordinate alternative with Engineer 1\ Notes: 1. Root curbs shall be provided with properly designed fabricated leveling devices so equipment is level and he root curb is installed to match he root slope. 2. Provide Perimeter angle support at all sides between structural steel. Size of angle based on load of equipment. Minimum size shall be 3" x 3" x 1W" 3. Root curbs shall not be supported by the root insulation. 4. Coordinate location of roof curb and roof opening with structure. 5. Roofing insulation shall be continuous under the rooftop equipment. D 3 Roof Equipment Support Curb Section MZt Scale: None 1X" rigid closed cell, Secure flashing to aluminumjacket polyisocyanu rate foam with stainless steel sheet metal screws. board insulation on all Wrapflashing will stainless steel ductwork exposed to banding to draw hashing tight mjacket weather. l 1" internal insulation on all duct Duct sizes indicated on plans raters exposed to weather. Internal to clear area Sheet metal size shall insulation shall be non -fiberglass, be larger than Shown to natural fiber duct liner like"Reflects. accommodate l" internal insulation. Refer to HVAC plans for duct size. All duct exposed to weather shall have an .020" thick aluminum jacket. Aluminum jacket shall overlap 2" at seams. Seal seams water tight with silicone sealant. Paint Duct as per Architect recommendation (See A -Plans) E Exterior wall. Refer to Architectural plans. PD 2 Exterior Exposed Ductwork M].1 Scale: None Round Duct; tap to rectangular duct elbow. See plans for dimensions and location. 1W rigid closed cell, Secure flashing to aluminum jacket polyisocyanu rate foam with stainless steel sheet metal screws. board. Insulation on all Wrap flashing with stainless steel ductwork exposed to bantling to draw flashing tight to jacket weather. l 1" internal insulation on all duct Duct sizes indicated on plans refers exposed to weather. Internal to clear area Sheet metal size shall insulation shall be non -fiberglass, be larger than shown to natural fiber duct liner like"Reflectis. accommodate l" internal insulation. Refer to HVAC plans for duct size. All duct exposed to weather shall have / .020" thick aluminumnumjacacket. Aluminum J/ jacket shall overlap 2" at seams. Seal seams water tight will silicone sealant. —Exterior wall. Refer to Architectural plans. D , Rectangular Duct Elbow Tap M] 1 Scale: None Paint Duct as Per Architects recommendation (See A -Plans) CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317. 288. 0681 IF :: 317. 288.0753 GGl,LABOR4 1.1 �G p F ♦ W - W - z \o STATE OF THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTEiLECTIIAL PROMIti OF CURRAN ARCHITECT -RE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITFpUI THE WRITTEN CONSENT OF CURRAN ARCHITECTME. � CWWJCM 3,JI$QIRP4N ARCMiERINf PLAYSCHOOL AT LEGACY GYM ADDITION 14454 COMMUNITY DRIVE CARMEL, INDIANA 46032 REVIEW SET 11.16.18 BID SET 11.26.18 PERMIT SET 02.04.19 1Q ADDENDUM 01 02.04.19 170299 HVAC DETAIL M 791