Provide piston type condensate Refrigerant piping up
pump like Sauerman S13100 with thru wall cavity.
detection unit located in FCN drain
pan. High -Wall type
ductless split FCU.
Condensate tlrain up thru wall
cavity. Refer to T" Series drawings.
Provide integral, drain pan mounted,
condensate pump detection unit. Mount FCU high on wall.
Notes:
1. Install all components per Manufacturer's installation
instructions.
2. Fan coils shall have a flooded drain pan interlock.
3. Refrigerant lines and condensate drains shall be
insulated.
4. Conceal all linesets, piping, power wiring, control
wiring and control components unless otherwise noted.
If concealment is not possible, contact Engineer for
adermOves prior to fabrication.
D 2 High -Wall Ductless Split
D �2M7.2
Scale: None
Provide mounting system that allows adjustment
In all 3 axis in over to allow FCU to align with
Structure ceiling grid.
1"contlensate than tubing. Refer to "P" Series
drawings for routing and sizing of the gravity
$" all -thread
draned potions of the condensate drains.
suspension bolts
Refrigerantu
piping Im
interstitial space. Refer to
refrigerant piping schematic.
a s�1
Ceiling Ceiling
Ceiling Cassette type ductless split FCU. Locate FCU within
2x2 grid cell of acoustic ceiling grid, and coordinate exact
location With Reflected Ceiling Plans.
Notes:
1. Install all components per Manufacturer's installation
instructions.
2. Fan coils shall have a flooded drain pan interlock.
3. Refrigerant lines and condensate drains shall be
insulated.
4. COOrdnata With lights and ceiling grid.
5. Connect OIA duct to the CIA port, and NOT the S/A
Fort.
6. Conceal all linesets, piping, power wiring, control
Wring and control components unless otherwise noted.
FOR CONSTRUCTION
If concealment is not possible, contact Engineer for
alternatives prior to fabrication.
mpliance with all regulations
ate and local Codes
D , Ceiling Cassette Ductless Split
Cityacalmel
Scale: IN
� 1 ..,An...11
�vst\l�' la
DATE: 06/17/19
CURRAN
ARCHITECTURE
5719 LAWTON LOOP E. DR. #212
INDIANAPOLIS, IN 46216
O :: 317. 288. 0681
IF :: 317. 288.0753
G0LLAR
1.1
$G
p
F
♦
C
W
—
z
\rel
STATE OF
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE FXCLUMVEINTELLECTIIAL PROPERTY
OF CURRAN AACHITECRRE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITFpUr THE WRITTEN
CONSENT OF CURRAN ARCHITECTIBE.
� CWWJCM 301$QIRP4N ARCMiECiINf
PLAYSCHOOL
AT LEGACY
GYM ADDITION
14454 COMMUNITY DRIVE
CARMEL, INDIANA 46032
REVIEW SET 11.16.18
BID SET 11.26.18
PERMIT SET 02.04.19
1Q ADDENDUM 01 02.04.19
170299
HVAC DETAIL
M792