HomeMy WebLinkAboutM7.2 - 190204RELEASED Subject to cl of S - Ceiling Provide piston type condensate Refrigerant piping up pump like Sauerman S13100 with thru wall cavity. detection unit located in FCN drain pan. High -Wall type ductless split FCU. Condensate tlrain up thru wall cavity. Refer to T" Series drawings. Provide integral, drain pan mounted, condensate pump detection unit. Mount FCU high on wall. Notes: 1. Install all components per Manufacturer's installation instructions. 2. Fan coils shall have a flooded drain pan interlock. 3. Refrigerant lines and condensate drains shall be insulated. 4. Conceal all linesets, piping, power wiring, control wiring and control components unless otherwise noted. If concealment is not possible, contact Engineer for adermOves prior to fabrication. D 2 High -Wall Ductless Split D �2M7.2 Scale: None Provide mounting system that allows adjustment In all 3 axis in over to allow FCU to align with Structure ceiling grid. 1"contlensate than tubing. Refer to "P" Series drawings for routing and sizing of the gravity $" all -thread draned potions of the condensate drains. suspension bolts Refrigerantu piping Im interstitial space. Refer to refrigerant piping schematic. a s�1 Ceiling Ceiling Ceiling Cassette type ductless split FCU. Locate FCU within 2x2 grid cell of acoustic ceiling grid, and coordinate exact location With Reflected Ceiling Plans. Notes: 1. Install all components per Manufacturer's installation instructions. 2. Fan coils shall have a flooded drain pan interlock. 3. Refrigerant lines and condensate drains shall be insulated. 4. COOrdnata With lights and ceiling grid. 5. Connect OIA duct to the CIA port, and NOT the S/A Fort. 6. Conceal all linesets, piping, power wiring, control Wring and control components unless otherwise noted. FOR CONSTRUCTION If concealment is not possible, contact Engineer for alternatives prior to fabrication. mpliance with all regulations ate and local Codes D , Ceiling Cassette Ductless Split Cityacalmel Scale: IN � 1 ..,An...11 �vst\l�' la DATE: 06/17/19 CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317. 288. 0681 IF :: 317. 288.0753 G0LLAR 1.1 $G p F ♦ C W — z \rel STATE OF THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE FXCLUMVEINTELLECTIIAL PROPERTY OF CURRAN AACHITECRRE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITFpUr THE WRITTEN CONSENT OF CURRAN ARCHITECTIBE. � CWWJCM 301$QIRP4N ARCMiECiINf PLAYSCHOOL AT LEGACY GYM ADDITION 14454 COMMUNITY DRIVE CARMEL, INDIANA 46032 REVIEW SET 11.16.18 BID SET 11.26.18 PERMIT SET 02.04.19 1Q ADDENDUM 01 02.04.19 170299 HVAC DETAIL M792