General Notes:
A.
All fittings, piping, fixtures, materials, etc. to meet the
cument Safe Drinking Water Act with all of its
amendments and the Reduction of Lead in Drinking
water Act
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
B.
All work shall complywith all national, state, local codes
THE IXCLUSIVE INTI LLECTIIAL PROPERTY
OF CURRAN AACHITECR.RE, AND ARE NOT
and ordinances pertaining to the work in This project.
TO BE USED OR REFRODUCEO, WHOLE OR
IN PART, WITHOUT THE WRITTEN
C.
All plumbing fixtures shall be Bull led with individual
CONSENT OF CURRAN ARCHITECTME.
water supply stops and code approved traps. Exposed
coraxfrtzolR aewwaRwlTeauRE
piping shall be chrome plated.
D.
Al plumbing fixtures shall be installed with approved
backflow, prevention devices.
PLAYSCHOOL
E.
No piping shall pass directly over electrical power
AT LEGACY
di saii bunion cabinets, panel boards, etc. Contracnorto
coordinate panel locations prior to piping installation.
GYM ADDITION
F.
DO NOT USE CELLULAR CORE PVC.
G.
All plumbing vents To W a minimum of 10'0'from any air
14454 COMMUNITY DRIVE
intake. Coordinate locations with HVAC plans.
CARMEL, INDIANA 46032
H.
Single tampons to plumbing fixtures shall be the same
size as on the plumbing fixture schedule unless
otherwise noted.
I.
Concealed gas piping shall be constructed in accordance
with code without unions, tubing fittings or running
threads.
J.
Gas lines run on roof to be supported by Roof Top Max
or similar and equal. DO NOT USE LUMBER FOR GAS
PIPING SUPPORT.
K.
Drypipefire protection system shall be used in all areas
subject to freezing.
L.
All waste, water, vent, gas and condensate lines shown
to be connected to their associated fixture/equipment,
unless noted otherwise. All equipment and systems
shown must be complete and usable upon completion of
REVIEW SET 11.16.18
project. All connections and installations to be perthe
BID SET 11.26.18
manufacturer's requirements.
PERMIT SET 02.04.19
Plan Notes:
A
ADDENDUM 01 02.04.19
O1j
Cond. down along wall to +3' above rim of mop sink.
Hold line astightto wall as practical.
146TH STREET
i
c
zo
o � 170299
U PLUMBING STORM &
PROJECT SANITARY WASTE PLAN
LOCATION P 2 • I
I(& KEY PLAN