HomeMy WebLinkAbout19060022 Building PlansARCHITECTURAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
mr WALL
® PARTIAL HEIGHT WALL
a>—u WINDOW/SIDELIGHT
DOORANDFRAME
(SEE DOOR SCHEDULE)
WALL
® PARTIAL HEIGHT WALL
>~¢ WINDOW/SIDELIGHT
lQ' J/ DOOR AND FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS,
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE W1 UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT/GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
F WALL WITH INSULATION ,
li
3ONELAYEROF 16"O.O.: � METALSTUDS "
5/a" TYPE "XGYPSUM BOARD
EACH SIDE;
EXTEND WAULTO
SOU UNDERSIDE OF CEILING:
HBEIRGLASWALL
SOUND BAST SIDE NSUILATION
INSIDE
WALL AND 2-0 EACH EACH SIDE OF WALL ABOVE
CEILING
DEMISING WALL TO DECK
WITH INSULATION
3Sy8 METAL STUDS AT 16" O.C.;
ONE LAYER OF % TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BAIT INSULATION INSIDE
WALL
H PARTIAL HEIGHT WALL
35% METALSTUDSAT16"O.C.;
ONE LAYER OF 6%' TYPE'%' GYPSUM BOARD
EACH SIDE;
EXTEND WALLTO*FD WITH FINISHED DRYWALL
PROVIDE T STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED:
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City Bf Cantonal
DATE: 06/17/19
GENERAL NOTES
I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT
2. REFER TO FINISH PUN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
PLAN NOTES
A0T ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS. COORDINATE WTH BUILDING
ON PATCHING COMMON AREA SIDE FINISHES.
COORDINATE SERVER REQUIREMENTS WITH TENANT AND TENANT'S
3. EXISTING BLINDS TO REMAIN. CONTRACTOR TO FIX OR REPLACE e52 IT VENDOR.
ANY DAMAGED BLINDS. DESIGN INTENT IS FOR EXISTING BLINDS
TO BE CLEANED TO LIKE NEW APPEARANCE. O RELOCATE EXISTING FIRE EXTINGUISHER TO THIS LOCATION. ALL
A03 FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA
10.
OPROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR
A04 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
® AREA NOT IN CONTRACT
❑ AREA OF WORK
CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W I". E NOT
A08 ALTER EXISTING WALL AS REQUIRED TO MATCH "WI"
PROVIDES 0 WIDE BORROWED LITE AND TIMELY FRAME, GLASS
A08 TO BE 3/8" BUTTGLAllED. DESIGN INTENT IS FRAME HEIGHT TO
MATCH STYLE, FINISH, AND SIZE OF EXISTING. PROVIDE VINYL FILM
ON GLASS; SEE FINISH PLAN FOR MORE INFORMATION.
SUPPORT COUNTER AS REQUIRED WTH RAKKS EH-I8I8-FM
AU7 BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING
AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK
CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO
INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP
DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. NORTH
SIDE OF COUNTER TO HAVE STAINLESS GROMMET TO ACCESS
POWER/DATE BELOW.
P01 EXISTING BREAK ROOM PLUMBING TO BE USED AT THIS LOCATION
IF POSSIBLE. IF NOT, PROVIDE POTABLE HOT AND COLD WATER
AND SANITARY WASTE AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
P02 PROVIDE WATER LINE FOR WATER COOLER AND REFRIGERATOR.
CONFIRM LOCATION WITH TENANT.
P03 PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT
PROVIDED DISHWASHER AT THIS LOCATION,
ARCHITECTURAL PLAN
0 T 4' 8' 16'
■
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARETHE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
LO
aN
r
J
w
I—
N
aN
0
N
J
�O
m
J
Z
O
z,30
J
L<<LJ
to
�
,,nnh
v�U
Z
z
O
ao
W
REVISIONS
PROJECT NUMBER
2019.063
PROD. Mil DRAWN BY
JJ JJ
FIRST FLOOR
ARCHITECTURAL
FLOOR PLAN
IN A111
LEGEND
NEW OR RELOCATED EXISTING TO REMAIN
LIGHT FIXTURE, 2'x4',
FLUORESCENT, LED
MEIALUX CRUSE OR EQUAL
RECESSED LIGHT
FIXTURE; LED HALO
DOWNLIGHT OR EQUAL
RECESSED DOWNLIGHT
OB LED; CONTECH RL38SA
6"INTEGRATED
LIGHT FIXTURE, 2'x4',
FLUORESCENT
k( RECESSED LIGHT
FIXTURE FLORESCENT
B EXT LIGHT FIXTURE ® EXIT EIGHT FIXTURE
EMERGENCY LIGHT FIXTURE EMERGENCY UGHT FIXTURE
LI GHT SWITCH # LIGHT SWITCH
'IN3 LIGHT SWITC H, 3-WAY $3 LIGHT SWITCH, SWAY
CIE LIGHT SWITC H, DIMMER $D LIGHT SWITCH, DIMMER
$NP SWITCH, PROJECTOR $P SWITCH, PROJECTOR SCREEN
SCREEN
A A
$NG SWITCH, GARBAGE DI$PO$ L $G SWITCH, GARBAGE DISPOSAL
(ABOVE COUNTERTOP) CE SWITCH, EXHAUST FAN $G SWITCH, EXHAUST FAN
LIGHTCIRCUIT -- . LIGHTCIRCUIT
CEIEINGGRID, CEIEINGGRID,
SUSPENDED, ZxdSUSPENDED, Zxd'
RELOCATED ® EXISTING DIFFUSER, LAY4N, TO'
DIFFUSER, LAY -IN, 2x2'
RELOCATED EXISTING DIFFUSER, LAY -IN,
DIFFUSER, LAY -IN, 4W' 4'XX
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW
HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
RELOCATE DIFFUSERS &
@)MECHANICAL DIFFUSER RELOCATION
Al zl 'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
GENERAL NOTES
I. REUSE EXISTING CEILING GRID. EXISTING GRID IS 2x4 AT8'-0'A.RF.
PROVIDE NEW 2x4 DUNE REVEAL EDGE CEILING TILES WITHIN EXISTING
GRID.
2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE
TO CREATE UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS ATTHER EXPENSE.
4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS,
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL
BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
NEED TO BE MET,
5.
6. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
7. NEW DEVICES AND FACE PLATES TO MATCH EXISTING WHERE
POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON
PLAN.
8. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS, ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDTIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
9. PROVIDE SEPARATE PRICE FOR ALL LIGHT SWITCH FACEPLATES TO BE
REPLACED WITH NEW SNAP ON FACE PLATES. DESIGN INTENT IS FOR
NO SCREWS TO BE VISIBLE.
MECHANICAL NOTES
MECHANICAL WORK IS LIMITED TO A DESIGNBUILDSCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED, ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR
EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTORIS iO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
NDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES,
® AREA NOT IN CONTRACT
RELEASED FOR CONSTRUCTION
❑ AREA OF WORK
Subject to compliance with all regulations
of State and Local Codes
City of Camlel
e ((��
�{vmlUtlonrk�L
\
DATE: 06/17/19
PLAN NOTES
miiiiiiiiiiim
ROt CONTROL ENTRY, HALLWAY, AND OPEN OFFICE LIGHTING
LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION, PROVIDE
MULTIPLE SWITCHES AS REQUIRED.
R02 PROVIDE CONTECH RL38SA 6' INTEGRATED LED LIGHT FIXTURE ON
COMMON HALLWAY SIDE ABOVE DOOR, DESIGN INTENT IS FOR
LIGHT TO BE CENTER ON DOOR/ FRAME AND INSTALLED AS
CLOSELY AS POSSIBLE TO DOOR. SWITCH TO BE INSIDE OF TENANT
SUITE,
REFLECTED CEILING PLAN
0 2' 4' 8' 16'
■
V
� O
N V 8p U
C
p O M �
O ^ O
w O M N
V �C
e Ra
'vw) C
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
U)
QN
r
J ul
Q N �N
ci
J J 0
m
0 z I
LcL JJ
N
,,nnN
v�U
Zz
�O
Q O
W
SSUE
REVISIONS
MANI DATE
IN 0.
AR10700017
STATE OF
PROJECT NUMBER
2019.063
DRAWN BY
JJ
FIRST FLOOR
REFLECTED
CEILING PLAN
NC Al21
LEGEND
ME
FLOOR COVERINGS
CARPET
DPT, MFG: SHAW
TYPE 24x24 CARPET TILE
PATTERN: 5T210 SITUATION STRATAWERX
COLOR: SKYLIGHT 08530
LUXURY VINYL TILE
NOTE: AT ALL LVT LOCATIONS, PROVIDE SKIMCOAT OF
ARDEX LEVELING LATEX AS NEEDED FOR SMOOTH
SUBFLOOR THAT WILL NOT ALLOW FOR TELEGRAPHING
OF IMPERFECTIONS IN THE FLOOR
LVT1 MFG: MILLIKEN
SIZE: 9" x 59.7" PLANK
PATTERN: Pike
COLOR: PIK 124-208-ANTLER
INSTALL: TBD BY TENANT IN FIELD
WALL BASE
ue, MFG: JOHNSONITE
TYPE: 4" VINYL COVE,}§" GAUGE
COLOR: 460 COTTON
PAINT / WALLCOVERING
Pr1 MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: SW 7063 NEBULOUS WHITE
FINISH: EGGSHELL
PT2 MFG SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: SW 7029 AGREEABLE GRAY
FINISH: EGGSHELL
�3 MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: SW 6236 GRAY HARBOR
FINISH: EGGSHELL
PLASTIC LAMINATE / SOLID SURFACE
PL1 MFG: WILSONART(LOWER CABINET)
COLOR: CARBON MESH 4880-38
PL2 MFG: PIONITE(UPPER CABINET)
COLOR: ICE FISHIN WFI81 SUEDE
pL3 MFG: ARBORITE (COUNTERTOP)
COLOR: ARTICSNOWP394VL
ALL FINISHES TO BE SELECTED. FINISHES SHALL MEET ALL CLASS
FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL
BUILDING CODE.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City Bf CII (�
�VT�SJ'�B*tiYWML
DATE: \ 06/17/19
GENERAL NOTES
I. REFER TO LEGEND FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
PLAN NOTES
iiiiiiiiiiim
F01 HEIGHT OF CARPET AND -VT ALLOWS FOR NO REQUIRED
TRANSITION.
PROVIDE VINYL FILM ON GLASS AT ENTRY DOOR/SIDELIGHT AND
F02 CONFERENCE ROOM 102 SIDE LIGHT. ALLOWANCE OF $1200
TOTAL FOR ALL FILM. EXACT FILM TBD BY TENANT.
PATCH COMMON HALLWAY SIDE WITH NEW FINISHES TO MATCH
F03 EXISTING; COORDINATE FINISHES WITH BUILDING OWNER.
P
e
O ZFICE
OPEN OFFICE
7
STG./I T
rm
THIS DRAWING. AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN. INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE. OR
IN PART. WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
U)
QN
r
J w
N
Q N
N
J �O
m
J Z
O z J
LJCJ
N
LU
v�U
ZZ
�O
Q O
W
REVISIONS
MARRI DATE I DB
N0.
AR10700017
STATE OF
CONFERENCE PROJECT NUMBER
PT_ ® 2019.063
F02
PT1 a 1 ENTRY cPn ve, PROJ. MGR DRAWN BY
,�1 PTz JJ JJ
POP iiiiiiiiiim
/Fo FIRST FLOOR
o , FINISH PLAN
® AREA NOT INCONTRACT FINISH PLAN
0 ]' 4' 8' 16' IN❑ AREA OF WORK V - I<) Al 31
TO EXILING
7 STACK
I
aG I ux I
I
I
IXv.L i ac.
I I
I I
SINK eV.
zW.
FE NOTE: REFER TO FLOOR PLAN
AND CASEWORK ELEVATIONS
FOR SINK LOCATIONS
I
—+ ro
dW.
BUILDING
DEAN
RISER
DIAGRAM
A211 TYPICALALLSINGLE LOCATIONS, NOT TO SCALE
2-32-3'
IASTIC LAMINATE (PL])
o
WALL CASHES
(SEE CASEWORK NOTE I)
F_ ,
SALVAGED SINKAND FAUCET
MICFOO BOX
FROM DECONSTRUCTION.
REFRIG.BY
TENANT OII
I "O HELF
II
II
JI
F_ -11
III
••
I
I 1
_
A" DEEP PLASTIC LAMINAE PL3) COUNTERTOP
E
W�4"HIGH BACKSPIASH. CONTRACTOR iO
1 I
I IIWATERI
`. i� COM ACT
qZODECOMPLIANTSINKRASECARINETWITH
ENSURE FINAL HEIGHT OF COUNTER AT SINK
�OOLEHI
DWBY
^INSTALLATION
TO BEAT 2-IQ.
BY
N M_____JIITENANTI
IL
IASTIc IAMINATF IPLII BASF
CANNER [SEE CASEWORK
I)
rO_6NOTE
(HOLD)
ATTACH CABINET MONT(SEE CASEWORK
ROVIDE FINISHED
INTEGRAL TOE KICK IF ASTRAGAL 6 REQUIRED,
NOTE I)TO REV -A -SHELF TOR EQUAL)
END PANELS IPLII
ASTRAGAL 15 TO BE ATTACHED TO CABINET
TRASH/RECYCUNG MECHANKMWBHA
AT DISHWASHER
DOORTO ALLOW FOR FULL CLEARANCE UNDER
DOOR MOUNT KIT AND INTEGRAL
OPENING.
SINK. PROVIDE HOORING UNDER CABINET AT
TOE -KICK. KIT MUST INCLUDE
THIS LOCATION.
COORDINATING RECEPTACLES THAT IRS
FULL WIDTH AND DEPTH OF CABINET.
ELEVATION - BREAK SIDE CASEWORK
0 1' 2' 4'
VIF
BACK5PLA5H. COUNTERTOP ROVIDE MITERED CORNER
TO BE SCRIBED TO WALL. AND VERTICAL SURFACE TO
CONNECT HEIGHT
TRANSITION.
P@I COUNTERLOP WITH; NO
BACKSPLASH. COUNTERTOP
TO BE SCRIBED TO WALL..
PROVIDE STAINLESS GROMMET
MR POW DER/DATE BELOW.
r
1
NEEDED
WTH RANKS OAES
WITH RAKFS
O MEAL ST
ATTACHEDTOMETALSTUDS
T
WITH W. UU AS
�F
UKTWACKIQ
NEEDED. D BE
VETO
OVER VERTICAL
INSTALLEDOVER
T.
SUPPORT.
ELEVATION -
WORK
SIDE COUNTER
0 1' 2' 4
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City IIF Calmed
DATE: 06/17/19
CASEWORK NOTES
GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN
ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF
BASE CABINET PRIOR TO ORDERING.
I. PROVIDE A.W.I. CUSTOM GRADE, FLUSH -OVERLAY CABINETS.
FABRICATE WITH PLASTIC LAMINATE (AS NOTED IN ELEVATIONS)
COVERED M.D.O. BOARD WITH 4" WIRE PULLS. COORDINATE WITH
ELEVATIONS FOR QUANTITIES.
- AT BREAK SIDE PROVIDE:
24" DEEP COUNTERTOPS
23" DEEP BASE CABINETS
I IX" DEEP )INTERIOR CLEAR DIMENSION) UPPER CABINETS
-AT WORKSIDE
PROVIDE 18" DEEP COUNTERTOP SUPPORTED AS REQUIRED
BY BRACKETS NOTED ON A111.
- 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNLESS
NOTED OTHERWISE.
DOOR SCHEDULE
# DIMENSIONS DOOR FRAME HARDWARE REM.
3'-Mx7'-M6'/4'
TYPE
D2
MATERIAL
MATCH
c
EXISTING
FINISH
TAINT
s XI
MATCH EXIST.
TYPE
MATERIAL
TIMELY
FINISH
MATCH
EXIST.
CR,ES,SL,CL
OIA
F2
R2
O1B
3'-0'k7'-O'k13/"
D1
MATCH
EXISTING
STAIN TO
MATCHEXIST.
F1
TIMELY
MATCH
EXIST.
PP•KS
02
3'-O'i
—
SEE REMARK
_
SEE REMARK
OL,KS
R1
03
EXISTING
—
--
--
—
--
--
OL,KS
04
EXISTING
—
--
--
—
--
--
OL,KS
05
EXISTING
—
--
--
—
--
--
OL,KS
06
EXISTING
—
--
--
—
--
--
OL,KS
07
EXISTING
—
--
--
—
--
--
—
08
EXISTING
—
--
--
—
--
--
OL,KS
09
CASED OPENING
DOOR/FRAME TYPES
3'-4"
0.
p p r'TEMPERED
w w GLASS, WOOD Ci
y U FLUSH BEAD w
\ STAINED TO y
0 0 \MATCH DOOR
0
o G IO
\ O
D1 D2 F1
F2
REMARKS
GENERAL: ALL INTERNAL SUITE BRASS HARDWARE TO BE SWITCHED TO
BRUSHED NICKEL.
BE SALVAGED DOOR AND FROM DECONSTRUCTION NOTE D04.
PROVIDE HARDWARE AS NOTED IN SCHEDULE.
R2. COORDINATE COMMON HALLWAY SIDE OF FROM COLOR WITH
LANDLORD. PROVIDE AND COORDINATE DOORBELL SYSTEM WITH
TENANT AND TENANT'S SECURITY VENDOR. PROVIDE VINYL FILM ON
DOOR AND SIDELIGHT.
HARDWARE LEGEND
CL CLOSER
CH COATHOOK
CR CA RD READE R BY TENANT(N.I.C.)
DB DEADBOLT
DL DUMMY LEVER
EL ELECTROMAGNETIC LOCK (PER IBC 2012)
ES ELECTRIC STRIKE BY TENANT(N.I.C.)
H HOLD OPEN
KP KICK PLATE
KS KICK STOP
OIL OFFICE LOCKSET
PH PANIC HARDWARE
PL PRIVACY LOCKSET
PP PUSH/PULL
PS PASSAGE LATCHSET
PV PIVOT HINGE
RL ROLLER LATCHES
SL STOREROOM LOCKSET
TS TOP STRIKES
DOOR/FRAME NOTES
I. REUSE DOORS FROM DECONSTRUCTION WHERE POSSIBLE; TOUCH UP
EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD
DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS
TO MATCH EXISTING. PRE -MACHINE NEW DOORS FOR CYLINDRICAL
LocKSErs.
2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS, REUSE
EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW
DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD.
PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND
LATCHSETS.
3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE
EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING
REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL
CORNERS UNLESS OTHERWISE NOTED ON PLAN.
5. REFER TO TENANT AND LANDLORD FOR KEYING REQUI REMENTS AND
LOCKSETS.
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION,
PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED
ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES.
ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE
INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
• 7'-0" HT. TO HAVE 3 HINGES
• GREATER THAN 7-0 IN IN HT. TO HAVE 4 HINGES
• FINISH TO MATCH HARDWARE SET
8. PROVIDE(1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE
NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE)AT EACH DOOR
UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL
STOP.
0 E
O
�O O U
N V 0 C
n Z ^ 'E
p
o. O ^ O
w O M
V �C
ES
e 1D
'vwJ C
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
U)
aN
r-
J LL
N
I a"
J J 0
m
O z I
W<<
0 N ^^</
,,nn�
v�U
ZZ
�O
ao
W L0
11.0
REVISIONS
MARK DATE I Dill
IN 0.
AR10700017
STATE OF
PROJECT NUMBER
2019.063
IPROJ. MGR DRAWN BY
JJ JJ _
FIRST FLOOR
DOOR SCHEDULE
INTERIOR DETAILS
A21 I
LEGEND
EXISTING TO BE REMOVED
WALL
EXISTING TO REMAIN
WALL
vxvxvx PARTIAL HEIGHT WALL � PARTIAL HEIGHT WALL
i DOOR AND FRAME
WINDOW / SIDELIGHT
CEILING GRID AND
7_-_—r TILES, Z'x4'
1 1 CEILING GRID AND
i--?--r TILES, 2'x2'
F'T
SUPPLY AIR DIFFUSERS
e �v
caum
EXHAUST FAN
L_J
LIGHT FIXTURE,
LL _rJJ FLUORESCENT, 2'x4'
q=1 LIGHT FIXTURE,
L_J11
FLUORESCENT, 2'x2'
LIGHT FIXTURE, CAN
P----, LIGHT FIXTURE,
FLUORESCENT
"fir+ LIGHT FIXTURE, TRACK
tk LIGHT FIXTURE,
LIGHT FIXTURE,
05)
PENDANT
$
LIGHTSWITCH
EXIT LIGHT
q�y^
C-]
EMERGENCY LIGHT
IBJ =1I ELECTRIC OUTLETS)
DATA OR
Ir COMMUNICATION
OUTLET
77 DOOR AND FRAME
x WINDOW/SIDELIGHT
NOTE: EXISTING FIXTURES THATARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of CNmel
DATE: 06/17/19
GENERAL NOTES
I. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T 111.
2. ALL TEXAS BEING REMOVED FROM PROJECT AREA ARE TO BE
CAREFULLY CONSIDERED FOR REUSE IN THE PROJECTOR
BUILDING IF POSSIBLE. FOR ALL ITEMS DETERMINED FOR
REMOVAL, REFER TO THE DECONSTRUCTION MANAGEMENT
CHECKLIST BELOW.
3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN
ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW
FINISHES AS REQUIRED.
4. REMOVE EXISTING CEILING AND LIGHT FIXTURES THROUGHOUT
SUITE, SEE DECONSTRUCTION MANAGEMENT CHECKLIST FOR
MORE INFORMATION.
DECONSTRUCTION MANAGEMENT CHECKLIST
THIS CHECKLIST ONLY APPLIES TO ITEMS BEING REMOVED. REFER TO DECONSTRUCTION PLAN.
CONTAINER:
a
ITEM BEING
z u
¢ z
REMARKS
REMOVED
co1�U
Q }
O p
3
�O
u
METAL LIGHT BOXES
CASEWORK UNIT
COORDINATE WITH BLDG. OWNER AND SDI FOR STORAGE LOCATION
CARPET TILE
✓
CEILING TILES
COORDINATE WITH BLDG. OWNER ON STORING FOR STOCK USE
APPLIANCES
COORDINATE WITH BLDG. OWNER AND PREVIOUS TENANT
GENERAL SORTING REQUIREMENTS (AS APPLICABLE):
CO -MINGLE RECYCLING CONTAINER: SHIPPING/PACKAGING, WOOD STUDS, WOOD TRIM, HVAC COMPONENTS,
CEILING GRID, METAL STUDS, WIRING/ CONDUIT, AND OUTLEFS/SW ITCHES
WASTE CONTAINER: DRYWALL, INSULATION, VINYL BASE AND LVT (LUXURY VINYL TILE)
CONTACTS:
KEUSE CARPET RECYCLING: COORDINATE PICK UP AND REQUIREMENTS WITH SUSAN SHAFER (3 V )33]-1950
® AREA NOT IN CONTRACT
❑ AREA OF WORK
PLAN NOTES
miiiiiiiiiiiiiim
D01 REMOVE EXISTING CABINETRY AND COUNTERTOP.
D02 SALVAGE EXISTING SINK AND FAUCET. EXISTING PLUMBING
LOCATION TO RAMAIN. NO SERVICE SINKS ARE BEING REMOVED.
OSALVAGE EXISTING METAL ENTRY DOOR AND COORDINATE WITH
D03 BUILDING OWNER ON STORAGE.
SALVAGE DOOR AND FRAME AND RELOCATE TO CONFERENCE
D04 102. SEE DOOR SCHEDULE FOR MORE INFORMATION.
SALVAGE AND RELOCATE FIRE EXTINGUISHER TO NEW LOCATION
D05 SHOWN ON At II.
DECONSTRUCTION PLAN
0 2' 4' 8' 16'
■
THIS DRAWING. AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH OIT DESIGNLin
aC4
r
J LU
H
N
a N
N
J J 0
m
J Z
0 z I
L.LJ
N
v�U
ZZ
�O
ao
W
PROJECT NUMBER
2019.063
III MGR DRAWN BY
JJ JJ
FIRST FLOOR
DECONSTRUCTION
PLAN
NC DIII
LEGEND
NEW CONSTRUCTION
EXISTING TO REMAIN
POWER OUTLET, DUPLEX
POWER OUTLET, DUPLEX
POWER OUTLET,
POWER OUTLET,
QUADRUPLEX
QUADRUPLEX
JQ
JUNCTION BOX
QJ
JUNCTION BOX
OCEILING
MOUNTED
CEILING MOUNTED
JUNCTION BOX
JUNCTION BOX
®
BOX, BLANK COVER PLATE
®
BOX, BLANK COVER PLATE
Q
BOX, OPEN
QO
BOX, OPEN
P
PROVIDE JUNCTION BOX
P
POWER AND DATA POLE
D
ABOVE CEILING FOR
O
POWER POLE
CONNECTION, POWER
POLE BY OTHERS.
FLOOR BOX WITH POWER
FLOOR BOX WITH POWER
FI®
AND DATA, FLUSH
&b
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
®
JUNCTION BOX AND
J 1i
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
b
OUTLET (PROVIDE BOX
b
DATA/COMMUNICATION
AND PULL STRING ONLY)
OUTLET
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42"
HEIGHT OF ELECTRICAL
OR DATA DEVICE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Calmel
DATE: 06/17/19
GENERAL NOTES
I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BV THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
PLAN NOTES
OE01 PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR
FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANTS SECURITY CONTRACTOR, SEE DOOR SCHEDULE
FOR MORE DETAILS.
E02 COORDINATE NORTH END POWER FOR COPY EQUIPMENT WITH
TENANT. PROVIDE POWER AS REQUIRED BELOW, GROMMET IN
COUNTER FOR ACCESS..
E03 PROVIDE POWER AND DATA FOR TENANT'S FURNITURE SYSTEM.
COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE
VENDOR,
E04 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT,
E05 PROVIDE POWER AT THIS LOCATION FOR TENANTS APARTMENT
COMPACT DISHWASHER" (PROVIDE DRAIN IF REQUIRED).
PROVIDE POWER AS REQUIRED FOR TENANT'S DOORBELL SYSTEM
E06 AT ENTRY DOOR. COORDINATE WITH TENANT AND TENANTS
SECURITY VENDOR.
EO] PROVIDE POWER FOR TENANT PROVIDED MICROWAVE, POWER
TO BE CENTER IN SHELF.
E08 COORDINATE SERVEWIT REQUIREMENTS WITH TENANT AND
TENANTS IT VENDOR,
E09 PROVIDE DUAL POWER/ USE RECEPTACLE AT THIS LOCATION.
UAREA NOT IN CONTRACT
UAREA OF WORK
ELECTRICAL PLAN
0 2' 4' 8' 16'
■ Ra
THIS DRAWING, AND hiE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
U)
QN
r
J ua
Q N
CV
'7
J (J CD
m
J Z
Q z I
WC
N
Oh�
0U
Z z
O
Q o
W
REVISIONS
PROJECT NUMBER
2019.063
PROD. Ml DRAWN BY
JJ JJ
FIRST FLOOR
ELECTRICAL PLAN
NC E111
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CODE SUMMARY
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE
PREVIOUS USE OF SPACE
B(USINESS(
OCCUPANCY CLASSIFICATION
B(USINESS(
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
35,178 SF/FLOOR
X
1 3STORIES
=
105,534 SF
TOTAL PROJECT AREA
1,786 SF
SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD
OCCUPANCY CALCULATIONS
GEN. OFFICE
1,786 SF
100
17
TOTAL OCCUPANTS IN PROJECT AREA 17
NUMBER OF EXITS
REQUIRED:I PROVIDED:2
SPRINKLER SYSTEM(YES/NO(
YES- EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
35,178 SF
ACCESSORY AREA EXCEEDS 10%
NO
FIREWALLS, AND/OROCCUPANCY
SEPARATIONS (IF REQUIRED(
N/A
ASHRAE90.1 SUMMARY
REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN(
BUILT BEFORE 19782
NO
BUILDING CONSTRUCTION TYPE
II-B
EX
RELEASED FOR CONSTRUCTION ❑
Subject to compliance with all regulations
of State and Local Codes
City Bf CaHmel (�
�VT�U'�D*tiYWML_
DATE: \ 06/17/19
AREA NOT IN CONTRACT
AREA OF WORK
LEGEND
LIFE SAFETY NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
Ep EXISTING ELECTRICAL PANEL LOCATION
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
EX MISTING MIT
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES(,
FIRE EXTINGUISHER
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
® EXIT SIGN
INTERNATIONAL FIRE CODE, NFPA(. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
44 DD
INB EMERGENCY LIGHT
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE,
— — — TRAVEL DISTANCE
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10, COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
GENERAL NOTES
LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING COMMON CORRIDOR TO REMAIN, EXISTING EXIT SIGNS, FIRE
PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE
EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET
ALL LOCAL AND STATE CODES.
LIFE SAFETY PLAN
0 4' 8' 16,
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERFY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SOH OII DESIGN.
U)
QN
r
J ul
Q N
CV
J J CD
m
Z
OZ�
CwC
to G
,,nnh �
v�U
Z z
O
o
W L0
11.0
REVISIONS
MARR1 DATE I DB
IN 0.
AR10700017
STATE OF
PROJECT NUMBER
2019.063
III MGR DRAWN BY
FIRST FLOOR
LIFE SAFETY
IN <D L100
GENERAL PROJECT NOTES
].BUILDING CODE COMPLIANCE: ALL WORKS HALL COMPLY WITH THE
REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS
DEFIN ED BY SECTION 601 OF THE INDIANA BUILDING CODE. ALL WORK
SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND
LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR
VERIFYING THE CURRENT APPLICABLE BUILDING CODES) FOR THEIR
RESPECTIVE SCOPE OF WORK. ENSURE THAT ALL MATERIALS AN D LABOR
ARE IN ACCORDANCE WITH THE BESTQUALITY STANDARDS OF EACH
RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL
CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN
ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING
CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND
ELECTRICAL CONSTRUCTION.
2. CONTRACTOR SITE VISITS: CONTRACTORS) SHALL VISIT THE WORK
SITE PRIOR TO COMMENCEMENT, THE DRAWINGS CONTAINED HEREIN
MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK
REQUIREMENTS. CONTRACTORS) SHALL MAKE THEMSELVES FAMILIAR
WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE
REQUIREMENTS OF THE SCOPE OF WORK.
3. CONTRACTOR FIELD VERIFICATION: FIELD VERIFY ALL DIMENSIONS
AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE
BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT
OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE
DRAWINGS, NOTED DIMENSIONS TAKE PRECEDENCE, VERIFY EXISTING
CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY
DISCREPANCY THROUGH THE GEN ERAL CONTRACTOR TO SCHOTT
DESIGN, INC.
4. GENERAL CONTRACTOR COORDINATION WITH OWNER: THE GEN ERAL
CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL
ON -SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE,
MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE
WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY
PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO
COORDINATE WORK BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS
NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. THE GENERAL
CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY
WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED
PRIOR TO AND DURI NO HOLIDAYS. LANDLORD RESERVES THE RIGHT TO
RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT
CONSTRUCTION 15 DEEMED TO INTERFERE WITH THE OPERATIONS OF
ADJACENT TENANTS.
5. PROJECT MATERIAL LEAD TIMES: FOR THOSE ITEMS TO BE ORDERED
REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE
PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE
OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE
RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT
SCHEDULE, THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT
RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S
FAILURE TO COMMUNICATE MATERIAL LEAD TIMES.
6. MATERIAL SUBSTITUTIONS: SUBSTITUTIONS FOR SPECIFICALLY NAMED
PRODUCTS WILL N TBEA WED W PAP
PROVAL
THE DESIGNER. SUBMIT REQUESTS FOR
SUBSTITUTIONS WITH APPROPRIAT
E
SUPPORT INFORMATION TO THE DESIGNER. ALLOW
REASONABLY
SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND
RENDER A DECISION.
7. SAFE WORK AREA: SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL
OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A
CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES,
SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE
FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AN D THE
PUBLIC AT ALL TIMES.
B. GENERAL CONTRACTOR CLEANUP PROCEDURES: THE GENERAL
CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP
PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN
ORDER TO CONDUCT BUSINESS IN ASAFE AND CLEAN ENVIRONMENT.
9. STAGING/ PARKING/ DUMPSTERS/ RESTROOMS: THE GENERAL
CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR
STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND
PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING
REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY
THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS.
10. DUST CONTROL: THE GENERAL CONTRACTOR SHALL USE DUST
PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS
DURING DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS
SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS ® 24"O.C., INSULATION
AND 6 MIL VAPOR BARRIER ON EACH SIDE,
11. PROJECT INSTALLATION CONFLICTS: CONTACTTHE DESIGNER
IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN
COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION
OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E.
WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE
INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING
PLAN).
12. SCHOTT DESIGN HAZARDOUS MATERIALS WAIVER: SCHOTT DESIGN,
INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY,
PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY
PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE
PROJECT SITE.
13. WOOD BLOCKING IN WALLS: PROVIDE FIRE -TREATED WOOD
BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING
MILLWORK, WALL STOPS, CABINETRY, ETC,
14. SHOP DRAWINGS: SHOP DRAWINGS OR CATALOG CUTS MUST BE
SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS
OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT
IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE
A SPECIFIC MANUFACTURER OR MODEL NUMBER. EXPEDITE
PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW
SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION,
AND DELIVERY OF MATERIALS AND EQUIPMENT.
15. PROJECT APPROVALS: ALL DETAILS, MATERIALS, AND INSTALLATIONS
ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL
APPROVAL BY THE OWNER.
16. CHANGE ORDERS: REVIEW AND COORDINATE ALL NEW WORK AND
EXISTING CONDITIONS WITH ALL OTHER TRADES, FIELD WORK ORDERS &
CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR
CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER
DURING PRE -BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT,
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Calmed
DATE: 06/17/19
17. FURNITURE AND EQUIPMENT EXCLUSIONS: FURNITURE, OFFICE EQUIPMENT
OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND
OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT
ATTACHED TO THE BUILDING ARE FOR REFERENCE ON LV AND ARE NOT TO BE
PROVIDED AS PART OF THE WORK UN LESS SPECIFICALLY STATED TO BE
PROVIDED,
18. WALL PATCHING: PATCH ALL GYPSUM WALLBOARD AT AREAS OF
ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH
DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH.
19. CONSTRUCTION CLEANING: EXECUTE A THOROUGH FINAL CLEAN AND
NSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL
SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL
BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE
HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL
CONTRACTOR INSTALLED APPLIANCES WORK & DO NOT LEAK.
20, O&MMATERIALS: PROVIDE TO THE OWNER ALL OPERATION AND/OR
MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND
SYSTEMS AT THE COMPLETION OF THE PROJECT.
21. PLAN DIMENSIONS: ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING
FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW
GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS
GOVERN.
22. WINDOW BLINDS: CONTRACTOR TO PROVIDE AN ALLOWANCE FOR
CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING
WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD.
23, PERMITTING: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS,
NSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO
THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED
LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS
STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT.
24, FIRE SEALING: FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS,
FLOORS, AND CEILINGS WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY
LOCAL JURISDICTIONS. CONTRACTOR TO BE AWARE THAT EXISTING
CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE,
BUILDING TYPE LISTED ON LIDO IS BASED UPON AVAILABLE INFORMATION AND
FIELD VERIFICATION.
25. WALL PENETRATIONS: WHERE STRUCTURAL BEAMS, DUCTWORK, ETC.
PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO
BE SCRI BED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED.
26. FLOOR LEVELING: CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR
CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED
AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES.
ADJUST DOORS AND FRAMES AS REQUIRED.
27, REPAIR GYPSUM WALLBOARD: WHERE DEMOLITION HAS OCCURRED AT
REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION.
PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR
ADJOIN TO EXISTING CORE WALLS,
28. EQUIPMENT INSTALLATION: ALL EQUIPMENT AND/OR FIXTURES SHALL BE
INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS OR INSTRUCTIONS.
FINISH NOTES
1. STATE BUILDING COMPLIANCE FOR FINISHES: ALL FINISHES SHALL COMPLY
WITH CHAPTER (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR
CLASS A FIRE RATINGS.
2. GYPSUM ASSOCIATION CONFORMITY: FOR ALL NEW DRYWALL
INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION.
(SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS,
CORNER BEADS, ETC.) PROVIDE NEW CEMENT BACKER BOARD AS A
SUBSTRATE FOR NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS.
3. COVER PLATES: REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL
PUN FOR COLOR OF ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE
ALL PLATES BEFORE PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR
TO CONFIRM DESIRED COLOR PRIOR TO PURCHASING NEW.
4. PAINTING: ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT
AN D TWO (2) FINISH COATS.
5. FLOORING TRANSITION STRIPS: FOR CHANGE IN FLOOR FINISH MATERIAL,
PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN
UNLESS NOTED OTHERWISE (I.E. WHERE VCT MEETS CARPET).
6. DELIVERY OF COMPREHENSIVE WORK PRODUCT: WHERE LIMITS OF WORK
ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS
HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK.
PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND
BUILDING OWNER.
7. WALL DEMOLITION: REFINISH SURFACES TO MATCH EXISTING WHERE
DEMOLITION HAS OCCURRED. REPAIR GYPSUM WALLBOARD WHERE
DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM
BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN
DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS.
8. TELEPHONE BOARDS: WHERE PHONE BOARD IS PROVIDED, PAINT BOARD
WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH.
9. MILLWORK SAMPLES: SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR
PAINTED AS SPECIFIED) TO SCHOTT DESIGN FOR REVIEW AND APPROVAL
PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK.
10. INTERIOR ELEVATION DETAILS: REFERENCE INTERIOR ELEVATION &
SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION.
11. PAINT &ADHESIVE VOC'S: ALL PAINTS AND ADHESIVES/SEALANTS SHALL
HAVE ZERO VOC CONTENT,
12. ADHESIVE MANUFACTURER RECOMMENDATIONS: ALL
ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT
MANUFACTURER.
MECHANICAL 8& ELECTRICAL NOTES
I. DESIGN/BUILD MEP: THE MECHANICAL, ELECTRICAL AND PLUMBING
SCOPES OF WORK ARE LIMITED TO BASIC DESIGN -BUILD ALTERATIONS
WHICH ARE OUTLINED IN THESE PLANS. THE DESIGN -BUILD CONTRACTORS
FOR EACH TRADE MUST NOTI FV THE ARCHITECT IF THEY FI ND THAT THE
SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR
PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY
NECESSARY ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE
FILED, OR IF ADDITIONAL INFORMATION IS NEEDED IN ORDER TO DO THE
WORK IN THE FIELD. THE MECHANICAL ELECTRICAL AND PLUMBING
DESIGN -BUILD CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE
STATE AND LOCAL BUILDING CODES.
FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE
APPROPRIATE DESIGN -BUILD CONTRACTOR AND MUST COMPLY WITH ALL
APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION
AND FIRE ALARM DESIGN -BUILD CONTRACTORS ARE RESPONSIBLE FOR
COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS,
2. DESIGN/BUILD HVAC: MECHANICAL WORK IS LIMITED TO
DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW
MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF
DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD
DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS
REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY
WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE
CODES,
3. HVAC HEAT LOADS: VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT
N THE TENANT SPACE, AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED.
CONFIRM WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQUIPMENT,
REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFFICE
SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING
OWNER/LANDLORD. CONTRACTOR TO ENSURE THAT ALL HVAC ZONES
ARE LOCATED APPROPRIATELY SUCH THAT NO SPLIT ZONES ARE IN
OFFICES OR CONFERENCE ROOMS.
4. HVAC DIFFUSER LOCATIONS: RELOCATE AIRSUPPLYDIFFUSERS AND
RETURN -AIR GRILLES AS REQUIRED, PROVIDE PROPER AIR SUPPLY FOR
DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. CONTRACTOR IS
TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS
REQUIRED BY CODE.
5. HVAC THERMOSTAT LOCATIONS: POSITION LOCATION OF ALL
THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN.
COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE
PANEL OR OTHER CONFLICTS.
6. DESIGN/BUILD ELECTRICAL: ELECTRICAL WORK IS LIMITED TO A
DESIGN -BUILD SCOPE AND 15 OUTLINED IN THESE DRAWINGS. ALL
ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE
CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING.
ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE
FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.
7. ELECTRICAL CODE COMPLIANCE: COMPLY WITH THE INDIANA
ELECTRICAL AND MECHANICAL CODE AND ALL OTHER APPLICABLE
CODES.
8. ELECTRICAL CIRCUITING: SIZE AND CIRCUIT ELECTRICAL POWER ITEMS
PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS
REQUIRED.
9. GIRL OUTLETS: ALL ELECTRICAL OUTLETS WITHIN 60 OF WATER ARE TO
BE G.F.C.I.
10. PHONE AND DATA ACCOMMODATIONS: AT EACH PHONE AND DATA
JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANTS
DATA CONTRACTOR 15 RESPONSIBLE FOR PULLING CONDUCTORS AND
PROVIDING APPROPRIATE TERMINALS AT FACE PLATE.
11. ELECTRICAL SWITCH PLATES: PROVIDE COLORED FACEPLATES FOR
ELECTRICAL OUTLETS & SWITCH PLATES TO MATCH EXISTING, UNLESS
OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE.
12. WORKSTATION POWER: PROVIDE JUNCTION BOXES OR POWER POLES
AT WORKSTATIONS WHERE SHOWN. REFER TO THE PUN FOR THE
APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA
VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM
WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE
RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS,
CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION
FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR
TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BOXES.
13. LIGHTING CIRCUITS: VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW
CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING
FOR NEW LAYOUT OF LIGHT FIXTURES.
14. ELECTRICAL OUTLETS: ENSURE THAT ALL MOUNTING HEIGHTS OF
ELECTRICAL DEVICES MEETA.D.A. REQUIREMENTS.
15. LIGHTING SWITCH PLATES: WHERE MULTIPLE SWITCHES ARE SHOWN
PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE.
16. LIGHT FIXTURE PLACEMENT: CENTER CEILING ELEMENTS IN CEILING
TILES, INCLUDING RECESSED DOWNLIGHTS, SMOKE DETECTORS,
SPRINKLER HEADS, AND EXITSIGNS UNLESS OTHERWISE NOTED,
17. EMERGENCY LIGHTING: PROVIDE EMERGENCY LIGHTING IN TENANT
SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS
OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES
SHOWN ON PLAN ARE FOR REFERENCE ONLY.
18, FIRE ALARM SYSTEM: PROVIDE ALARM NOTIFICATION APPLIANCES
(HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE
PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS
NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING
CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT I N
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE,
20. FIRE ALARM DEVICE LOCATIONS: COORDINATE WITH THE
OWNER TENANT PRIOR TO INSTALLATION OF FIRE DETECTION DEVICES
REGARDING ALL DEVICE LOCATIONS i0 AVOID CONFLICT WITH FEATURE
WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND
TENANT -INSTALLED ITEMS I.E. PRESENTATION BOARDS A V EQUIPMENT
AND PROJECTION SCREENS).
21. MISTING LIGHT FIXTURE RELAMP: IF REQUIRED, AND AS NECESSARY,
PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING SPACES.
CONSULT WITH LANDLORD.
22. HVAC CONTRACTOR AIR BALANCE: CONTRACTOR TO PERFORM AIR
BALANCE UPON COMPLETION OF HVAC SCOPE. PROVIDE REPORT TO
LANDLORD.
23. HVAC FLEX DUCT: FLEX DUCT MUST MEET ASHRAE STANDARD
BUILDING CODES FOR FLEX DUCT LENGTH.
24. ELECTRICAL CIRCUITS: AREAS WITHIN ELECTRICAL SCOPE MUST BE
POWERED BY THE ELECTRICAL PANEL FROM THE FLOOR ON WHICH
CONSTRUCTION OCCURS.
25, SUPPLEMENTAL HVAC/ELECTRICAL: IN THE EVENT THAT ANY
SUPPLEMENTAL HVAC EQUIPMENT OR ABOVE BUILDING STANDARD
ELECTRICAL POWER FACILITIES ARE INSTALLED (SUCH AS IN AN IT SERVER
ROOM) CONTRACTOR SHOULD FURNISH AND INSTALL ADDITIONAL
ELECTRICAL AND BTU SUB -METERING SO AS TO ENABLE OWNER TO
MONITOR TENANTS UTILITY CONSUMPTION (IN RELATION TO THE SU ELECT
EQUIPMENT) GOING FORWARD. THE MAKE AND MODEL OF
CONTRACTOR'S PROPOSED METERS SHOULD BE REVIEWED AND
APPROVED BY OWNER PRIOR TO CONTRACTOR INSTALLATION.
26. ENGINEERED MEP DRAWINGS: WHEN REQUIRED BY STATE BUILDING
CODE, THE CONTRACTORS) SHALL PROVIDE DESIGN/BUILD DRAWINGS
FOR MECHANICAL, PLUMBING, ELECTRICAL, OR FIRE SUPPRESSION.
DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND SUBMITTED
BY THE CONTRACTOR FOR STATE DESIGN REVIEW,
27. EQUIPMENT INSTALLATIONS: ALL EQUIPMENT AND/OR FIXTURES SHALL
BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS OR INSTRUCTIONS,
28. BUILDING DIRECTORY: THE BUILDING AUTOMATION SYSTEM GRAPHIC
AND PROGRAMMING TO BE UPDATED WITH NEW TENANT'S INFORMATION
FOR FUTURE USE.
29. ELECTRICAL PANELS: ALL ELECTRICAL PANELS TO GET UPDATED
CIRCUIT SCHEDULES.
FIRE PROTECTION NOTES
I. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10.
COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND
HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO
A VISIBLE EXTINGUISHER,
THE FOLLOWING NOTES APPLY ON LV IN EXISTING SPRINKLERED FACILITIES.
2. DESIGN BUILD FIRE PROTECTION SYSTEM: FIRE PROTECTION WORK IS
TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL
CONTRACT, PROVIDE A COMPLETE, WORKING SYSTEM, SCHOTT
DESIGN, INC., IS NOT RESPONSIBLE FORTHE DESIGN, INSTALLATION, OR
RENOVATION OF THE FIRE SPRINKLER SYSTEM.
3. FIRE PROTECTION SYSTEM CODE COMPLIANCE: THE DESIGN/BUILD
CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE
INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES
AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE
SPRINKLER/FIRE SUPPRESSION SYSTEMS.
4. FIRE PROTECTION DESIGN DRAWINGS: THE FIRE PROTECTION
CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL
FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND
LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. SPRINKLER HEADS: PROVIDE NEW OR RELOCATE EXISTING SPRINKLER
HEADS AS REQUIRED, PROVIDE MISSING COVER/ESCUTCHEON PLATES
FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING
CONDITIONS PRIOR TO THE START OF WORK.
DOCUMENT APPROVAL
DECONSTRUCTION NOTES
I. DECONSTRUCTION DEFINITION: CAREFULLY DISMANTLE SPACES WITH
THE GOAL OF MAXIMIZING THE REUSE POTENTIAL OF ITS COMPONENTS,
2. DECONSTRUCTION MANAGEMENT CHECKLIST: ALL ITEMS SHOWN ON
THE DECONSTRUCTION PLAN HAVE BEEN CAREFULLY CONSIDERED FOR
RECOVERY, REUSE, AND RECYCLING WITH THE BEST INTENT TO DIVERT
ITEMS FROM THE LANDFILL. REFER TO DECONSTRUCTION MANAGEMENT
CHECKLIST FOR SPECIFIC INSTRUCTIONS.
3. RECYCLING: GENERAL CONTRACTOR IS RESPONSIBLE FOR
RECYCLING ANY AND ALL POSSIBLE PROJECT MATERIAL WASTE AND
COORDINATING THE APPROPRIATE HAULING CONTAINERS WITH THE
WASTE MANAGEMENT SUB -CONTRACTOR.
4. MISTING STRUCTURAL ELEMENTS OF BUILDING: NO STRUCTURAL OR
LOAD -BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR
DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED
OTHERWISE ON THE DRAWINGS, PROTECT ALL EXISTING STRUCTURAL
MEMBERS DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR
SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS
NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL CONTACTSCHO T
DESIGN IMMEDIATELY IF THE CONTRACTORS) IN THE FIELD SUSPECT
THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR
OTHERWISE LOAD -BEARING, BEWARE OF STRUCTURAL COLUMNS
AND/OR BEAMS THAT MAY BE CONCEALED BEHIN D FINISHES THAT ARE
NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOLISHING
BUILDING FINISHES OR PARTITIONS ADJACENT TO OR AROUND
STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR
INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM.
5. EQUIPMENT, FIXTURE, FINISH REUSE: WHERE EQUIPMENT, FIXTURES,
OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO
BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN
THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF
THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED,
UNLESS OTHERWISE DIRECTED BY OWNER.
6. DECONSTRUCTION PLANS: REMOVE ALL EXISTING WALLS AND
DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES, NOTE
THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DECONSTRUCTION
PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DECONSTRUCTION.
7. FIELD VERIFICATION OF EXISTING CONDITIONS: REMOVE ALL
CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS
REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY
EXISTING CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR
CLARIFICATION OF EXISTING FINISHES TO REMAIN,
8. PROTECTION OF BUILDING ELEMENTS TO REMAIN: USE CARE TO
PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS
TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID,
TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES,
EQUIPMENT, CASEWORK, AND FINISHES. THE CONTRACTOR SHALL
REPLACE AND OR REPAIR AT THE CONTRACTOR'S COST ANY SUCH
ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE
OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN
GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT.
9. REMOVAL OF ABANDONED CABLING& WIRING: PER THE INDIANA
ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION)
REMOVE ALL ACCESSIBLE PORTIONS OF ABANDON ED CABLES AND
WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING,
COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES,
COAXIAL CABLES, FIBER OPTIC CABLES RACEWAYS, AND PLTC CABLES
REFER TO SECTION 300.21. ANYSUCH CABLE OR WIRING SHOULD BE
PULLED AND REMOVED BACK TO THEIR MAIN SOURCES ON THE FLOOR
(I.E. ELECTRICAL PANELS, PHONE BOARDS, ETC.)
10. PROTECTION OF ABANDONED/TERMINATED BUILDING SYSTEM
ELEMENTS: WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY
ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL
REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN
STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING
SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL
TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO
PROVIDE AN "AS -BUILT' SEE INDICATING THE LOCATION OF ALL
PERMANENTLY ABANDONED SYSTEMS.
11. HAZARDOUS MATERIALS: GENERAL CONTRACTOR IS RESPONSIBLE
FOR IDENTIFYING ANY AND ALL ITEMS THAT MAY CONTAIN HAZARDOUS
OR HARMFUL MATERIALS. ALL IDENTIFIED ITEMS MUST BE PROPERLY
DISPOSED OF PER EPA AND INDIANA DEPARTMENT OF ENVIRONMENTAL
MANAGEMENT RULES AND REGULATIONS.
12. COSTS: GENERAL CONTRACTOR TO PROVIDE ANY COST RELATED
TO SORTING AND RECYCLING, AS WELL AS ALL SCRAP METAL INCOME,
AS PART OF THE DEMOLITION/DECONSTRUCTION BASE BID.
13. RECEIPTS: GENERAL CONTRACTOR MUST OBTAIN AND PROVIDE TO
OWNER RECEIPTS ON ALL RECYCLED ITEMS INCLUDING CREDIT FOR
METALS,
TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED
IN THESE DOCUMENTS.
TENANT/CLIENT COMPANY NAME DATE
TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME
ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE
TENANT/CLIENT.
THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.
_MILL/CASEWORK NOTES
1. CASEWORK/MILLORK: CASEWORK AND MILLWORK GENERALLY
INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE
GEN ERAL CONTRACT.
2. AWI COMPLIANCE: UNLESS INDICATED OTHERWISE, COMPLY WITH
ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS
FOR CUSTOM GRADE WOODWORK.
3. MILLWORK SHOP DRAWINGS: FURNISH SHOP DRAWINGS ON ALL
MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AN D
SCHOTT DESIGN PRIOR TO FABRICATION.
4. MILLWORK FIELD VERIFICATION: WHERE CASEWORK AND MILLWORK
ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST
DIMENSIONS OF AS -BUILT CONDITIONS IN FIELD. REPORT ANY
DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL
CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK
TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER
THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS.
5. DRAWING REVIEW AND DISCREPANCIES: VERIFY FINISHES (LAMINATE,
VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION DRAWINGS
WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES,
IMMEDIATELY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN
THROUGH THE GEN ERAL CONTRACTOR.
6. MILLWORK REQUIREMENTS: REFER TO MILLWORK SECTIONS &
ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD,
COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED.
BACKSPLASHES TO BE FIELD APPLIED. REFER TO MILLWORK SECTIONS &
ELEVATIONS FOR CABINETRY SPECIFICATIONS(CUSTOM PLASTIC
LAMINATE OR PRE -MANUFACTURED STOCK CABINETRY). EDGES OF
PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE
PLASTIC LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING
UNLESS NOTED OTHERWISE.
7. MILLWORK WALL BLOCKING: TO PROVIDE BLOCKING IN WALLS FOR
ALL MILLWORK, WALL STOPS, HARDWARE, AND CABINETRY WHERE
SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED.
.9
Ans ,I e,Inrnn"9unnRi
,...
-�s v
a....c.e9
We Ap
c.«.c,.., .Q
c
9aromm�wero
d
x
,.m
R e.1✓
„p9
�a 1.9 9i,...9'"'
VICINITY MAP
NOT TO SCALE
KEY PLAN - 1 ST FLOOR
N
NOT TO SCALE
C
INDEX OF DRAWINGS
TIII COVER SHEET AND GENERAL PROJECTNOTES
LI00 LIFE SAFETY PLAN
DI I I DECONSTRUCTION PLAN
At I I ARCHITECTURAL FLOOR PLAN
A121 REFLECTED CEILING PLAN
A131 FINISH PLAN
A211 DOOR SCHEDULE/ INTERIOR DETAILS
EIII ELECTRICALPLAN
THIS DRAWING. AND ME IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT ME WRITTEN
CONSENT OF SCHOTT DESIGN.
aN
r
J LU
H
N
a1 N
J � o
J �O
m
J Z
Q
OZ
1
Ow
N
H
UJ Q
OU
ZZ
R� O
U
ao
W LO
LO
REVISIONS
PROJECT NUMBER
2019.063
PROJ. MGR DRAWN BY
JJ JJ
FIRST FLOOR
COVER SHEET AND
GENERAL NOTES
T I I I