HomeMy WebLinkAbout19060022 Building PlansARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN mr WALL ® PARTIAL HEIGHT WALL a>—u WINDOW/SIDELIGHT DOORANDFRAME (SEE DOOR SCHEDULE) WALL ® PARTIAL HEIGHT WALL >~¢ WINDOW/SIDELIGHT lQ' J/ DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS, WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE W1 UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT/GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. F WALL WITH INSULATION , li 3ONELAYEROF 16"O.O.: � METALSTUDS " 5/a" TYPE "XGYPSUM BOARD EACH SIDE; EXTEND WAULTO SOU UNDERSIDE OF CEILING: HBEIRGLASWALL SOUND BAST SIDE NSUILATION INSIDE WALL AND 2-0 EACH EACH SIDE OF WALL ABOVE CEILING DEMISING WALL TO DECK WITH INSULATION 3Sy8 METAL STUDS AT 16" O.C.; ONE LAYER OF % TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BAIT INSULATION INSIDE WALL H PARTIAL HEIGHT WALL 35% METALSTUDSAT16"O.C.; ONE LAYER OF 6%' TYPE'%' GYPSUM BOARD EACH SIDE; EXTEND WALLTO*FD WITH FINISHED DRYWALL PROVIDE T STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED: RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City Bf Cantonal DATE: 06/17/19 GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT 2. REFER TO FINISH PUN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. PLAN NOTES A0T ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. COORDINATE WTH BUILDING ON PATCHING COMMON AREA SIDE FINISHES. COORDINATE SERVER REQUIREMENTS WITH TENANT AND TENANT'S 3. EXISTING BLINDS TO REMAIN. CONTRACTOR TO FIX OR REPLACE e52 IT VENDOR. ANY DAMAGED BLINDS. DESIGN INTENT IS FOR EXISTING BLINDS TO BE CLEANED TO LIKE NEW APPEARANCE. O RELOCATE EXISTING FIRE EXTINGUISHER TO THIS LOCATION. ALL A03 FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. OPROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR A04 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. ® AREA NOT IN CONTRACT ❑ AREA OF WORK CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W I". E NOT A08 ALTER EXISTING WALL AS REQUIRED TO MATCH "WI" PROVIDES 0 WIDE BORROWED LITE AND TIMELY FRAME, GLASS A08 TO BE 3/8" BUTTGLAllED. DESIGN INTENT IS FRAME HEIGHT TO MATCH STYLE, FINISH, AND SIZE OF EXISTING. PROVIDE VINYL FILM ON GLASS; SEE FINISH PLAN FOR MORE INFORMATION. SUPPORT COUNTER AS REQUIRED WTH RAKKS EH-I8I8-FM AU7 BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. NORTH SIDE OF COUNTER TO HAVE STAINLESS GROMMET TO ACCESS POWER/DATE BELOW. P01 EXISTING BREAK ROOM PLUMBING TO BE USED AT THIS LOCATION IF POSSIBLE. IF NOT, PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. P02 PROVIDE WATER LINE FOR WATER COOLER AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. P03 PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT PROVIDED DISHWASHER AT THIS LOCATION, ARCHITECTURAL PLAN 0 T 4' 8' 16' ■ THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARETHE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC.. AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. LO aN r J w I— N aN 0 N J �O m J Z O z,30 J L<<LJ to � ,,nnh v�U Z z O ao W REVISIONS PROJECT NUMBER 2019.063 PROD. Mil DRAWN BY JJ JJ FIRST FLOOR ARCHITECTURAL FLOOR PLAN IN A111 LEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'x4', FLUORESCENT, LED MEIALUX CRUSE OR EQUAL RECESSED LIGHT FIXTURE; LED HALO DOWNLIGHT OR EQUAL RECESSED DOWNLIGHT OB LED; CONTECH RL38SA 6"INTEGRATED LIGHT FIXTURE, 2'x4', FLUORESCENT k( RECESSED LIGHT FIXTURE FLORESCENT B EXT LIGHT FIXTURE ® EXIT EIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY UGHT FIXTURE LI GHT SWITCH # LIGHT SWITCH 'IN3 LIGHT SWITC H, 3-WAY $3 LIGHT SWITCH, SWAY CIE LIGHT SWITC H, DIMMER $D LIGHT SWITCH, DIMMER $NP SWITCH, PROJECTOR $P SWITCH, PROJECTOR SCREEN SCREEN A A $NG SWITCH, GARBAGE DI$PO$ L $G SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) CE SWITCH, EXHAUST FAN $G SWITCH, EXHAUST FAN LIGHTCIRCUIT -- . LIGHTCIRCUIT CEIEINGGRID, CEIEINGGRID, SUSPENDED, ZxdSUSPENDED, Zxd' RELOCATED ® EXISTING DIFFUSER, LAY4N, TO' DIFFUSER, LAY -IN, 2x2' RELOCATED EXISTING DIFFUSER, LAY -IN, DIFFUSER, LAY -IN, 4W' 4'XX NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELOCATE DIFFUSERS & @)MECHANICAL DIFFUSER RELOCATION Al zl 'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION GENERAL NOTES I. REUSE EXISTING CEILING GRID. EXISTING GRID IS 2x4 AT8'-0'A.RF. PROVIDE NEW 2x4 DUNE REVEAL EDGE CEILING TILES WITHIN EXISTING GRID. 2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS ATTHER EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET, 5. 6. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 7. NEW DEVICES AND FACE PLATES TO MATCH EXISTING WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 8. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS, ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDTIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 9. PROVIDE SEPARATE PRICE FOR ALL LIGHT SWITCH FACEPLATES TO BE REPLACED WITH NEW SNAP ON FACE PLATES. DESIGN INTENT IS FOR NO SCREWS TO BE VISIBLE. MECHANICAL NOTES MECHANICAL WORK IS LIMITED TO A DESIGNBUILDSCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED, ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTORIS iO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE NDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, ® AREA NOT IN CONTRACT RELEASED FOR CONSTRUCTION ❑ AREA OF WORK Subject to compliance with all regulations of State and Local Codes City of Camlel e ((�� �{vmlUtlonrk�L \ DATE: 06/17/19 PLAN NOTES miiiiiiiiiiim ROt CONTROL ENTRY, HALLWAY, AND OPEN OFFICE LIGHTING LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION, PROVIDE MULTIPLE SWITCHES AS REQUIRED. R02 PROVIDE CONTECH RL38SA 6' INTEGRATED LED LIGHT FIXTURE ON COMMON HALLWAY SIDE ABOVE DOOR, DESIGN INTENT IS FOR LIGHT TO BE CENTER ON DOOR/ FRAME AND INSTALLED AS CLOSELY AS POSSIBLE TO DOOR. SWITCH TO BE INSIDE OF TENANT SUITE, REFLECTED CEILING PLAN 0 2' 4' 8' 16' ■ V � O N V 8p U C p O M � O ^ O w O M N V �C e Ra 'vw) C THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. U) QN r J ul Q N �N ci J J 0 m 0 z I LcL JJ N ,,nnN v�U Zz �O Q O W SSUE REVISIONS MANI DATE IN 0. AR10700017 STATE OF PROJECT NUMBER 2019.063 DRAWN BY JJ FIRST FLOOR REFLECTED CEILING PLAN NC Al21 LEGEND ME FLOOR COVERINGS CARPET DPT, MFG: SHAW TYPE 24x24 CARPET TILE PATTERN: 5T210 SITUATION STRATAWERX COLOR: SKYLIGHT 08530 LUXURY VINYL TILE NOTE: AT ALL LVT LOCATIONS, PROVIDE SKIMCOAT OF ARDEX LEVELING LATEX AS NEEDED FOR SMOOTH SUBFLOOR THAT WILL NOT ALLOW FOR TELEGRAPHING OF IMPERFECTIONS IN THE FLOOR LVT1 MFG: MILLIKEN SIZE: 9" x 59.7" PLANK PATTERN: Pike COLOR: PIK 124-208-ANTLER INSTALL: TBD BY TENANT IN FIELD WALL BASE ue, MFG: JOHNSONITE TYPE: 4" VINYL COVE,}§" GAUGE COLOR: 460 COTTON PAINT / WALLCOVERING Pr1 MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW 7063 NEBULOUS WHITE FINISH: EGGSHELL PT2 MFG SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW 7029 AGREEABLE GRAY FINISH: EGGSHELL �3 MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW 6236 GRAY HARBOR FINISH: EGGSHELL PLASTIC LAMINATE / SOLID SURFACE PL1 MFG: WILSONART(LOWER CABINET) COLOR: CARBON MESH 4880-38 PL2 MFG: PIONITE(UPPER CABINET) COLOR: ICE FISHIN WFI81 SUEDE pL3 MFG: ARBORITE (COUNTERTOP) COLOR: ARTICSNOWP394VL ALL FINISHES TO BE SELECTED. FINISHES SHALL MEET ALL CLASS FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City Bf CII (� �VT�SJ'�B*tiYWML DATE: \ 06/17/19 GENERAL NOTES I. REFER TO LEGEND FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. PLAN NOTES iiiiiiiiiiim F01 HEIGHT OF CARPET AND -VT ALLOWS FOR NO REQUIRED TRANSITION. PROVIDE VINYL FILM ON GLASS AT ENTRY DOOR/SIDELIGHT AND F02 CONFERENCE ROOM 102 SIDE LIGHT. ALLOWANCE OF $1200 TOTAL FOR ALL FILM. EXACT FILM TBD BY TENANT. PATCH COMMON HALLWAY SIDE WITH NEW FINISHES TO MATCH F03 EXISTING; COORDINATE FINISHES WITH BUILDING OWNER. P e O ZFICE OPEN OFFICE 7 STG./I T rm THIS DRAWING. AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN. INC.. AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE. OR IN PART. WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. U) QN r J w N Q N N J �O m J Z O z J LJCJ N LU v�U ZZ �O Q O W REVISIONS MARRI DATE I DB N0. AR10700017 STATE OF CONFERENCE PROJECT NUMBER PT_ ® 2019.063 F02 PT1 a 1 ENTRY cPn ve, PROJ. MGR DRAWN BY ,�1 PTz JJ JJ POP iiiiiiiiiim /Fo FIRST FLOOR o , FINISH PLAN ® AREA NOT INCONTRACT FINISH PLAN 0 ]' 4' 8' 16' IN❑ AREA OF WORK V - I<) Al 31 TO EXILING 7 STACK I aG I ux I I I IXv.L i ac. I I I I SINK eV. zW. FE NOTE: REFER TO FLOOR PLAN AND CASEWORK ELEVATIONS FOR SINK LOCATIONS I —+ ro dW. BUILDING DEAN RISER DIAGRAM A211 TYPICALALLSINGLE LOCATIONS, NOT TO SCALE 2-32-3' IASTIC LAMINATE (PL]) o WALL CASHES (SEE CASEWORK NOTE I) F_ , SALVAGED SINKAND FAUCET MICFOO BOX FROM DECONSTRUCTION. REFRIG.BY TENANT OII I "O HELF II II JI F_ -11 III •• I I 1 _ A" DEEP PLASTIC LAMINAE PL3) COUNTERTOP E W�4"HIGH BACKSPIASH. CONTRACTOR iO 1 I I IIWATERI `. i� COM ACT qZODECOMPLIANTSINKRASECARINETWITH ENSURE FINAL HEIGHT OF COUNTER AT SINK �OOLEHI DWBY ^INSTALLATION TO BEAT 2-IQ. BY N M_____JIITENANTI IL IASTIc IAMINATF IPLII BASF CANNER [SEE CASEWORK I) rO_6NOTE (HOLD) ATTACH CABINET MONT(SEE CASEWORK ROVIDE FINISHED INTEGRAL TOE KICK IF ASTRAGAL 6 REQUIRED, NOTE I)TO REV -A -SHELF TOR EQUAL) END PANELS IPLII ASTRAGAL 15 TO BE ATTACHED TO CABINET TRASH/RECYCUNG MECHANKMWBHA AT DISHWASHER DOORTO ALLOW FOR FULL CLEARANCE UNDER DOOR MOUNT KIT AND INTEGRAL OPENING. SINK. PROVIDE HOORING UNDER CABINET AT TOE -KICK. KIT MUST INCLUDE THIS LOCATION. COORDINATING RECEPTACLES THAT IRS FULL WIDTH AND DEPTH OF CABINET. ELEVATION - BREAK SIDE CASEWORK 0 1' 2' 4' VIF BACK5PLA5H. COUNTERTOP ROVIDE MITERED CORNER TO BE SCRIBED TO WALL. AND VERTICAL SURFACE TO CONNECT HEIGHT TRANSITION. P@I COUNTERLOP WITH; NO BACKSPLASH. COUNTERTOP TO BE SCRIBED TO WALL.. PROVIDE STAINLESS GROMMET MR POW DER/DATE BELOW. r 1 NEEDED WTH RANKS OAES WITH RAKFS O MEAL ST ATTACHEDTOMETALSTUDS T WITH W. UU AS �F UKTWACKIQ NEEDED. D BE VETO OVER VERTICAL INSTALLEDOVER T. SUPPORT. ELEVATION - WORK SIDE COUNTER 0 1' 2' 4 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City IIF Calmed DATE: 06/17/19 CASEWORK NOTES GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF BASE CABINET PRIOR TO ORDERING. I. PROVIDE A.W.I. CUSTOM GRADE, FLUSH -OVERLAY CABINETS. FABRICATE WITH PLASTIC LAMINATE (AS NOTED IN ELEVATIONS) COVERED M.D.O. BOARD WITH 4" WIRE PULLS. COORDINATE WITH ELEVATIONS FOR QUANTITIES. - AT BREAK SIDE PROVIDE: 24" DEEP COUNTERTOPS 23" DEEP BASE CABINETS I IX" DEEP )INTERIOR CLEAR DIMENSION) UPPER CABINETS -AT WORKSIDE PROVIDE 18" DEEP COUNTERTOP SUPPORTED AS REQUIRED BY BRACKETS NOTED ON A111. - 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNLESS NOTED OTHERWISE. DOOR SCHEDULE # DIMENSIONS DOOR FRAME HARDWARE REM. 3'-Mx7'-M6'/4' TYPE D2 MATERIAL MATCH c EXISTING FINISH TAINT s XI MATCH EXIST. TYPE MATERIAL TIMELY FINISH MATCH EXIST. CR,ES,SL,CL OIA F2 R2 O1B 3'-0'k7'-O'k13/" D1 MATCH EXISTING STAIN TO MATCHEXIST. F1 TIMELY MATCH EXIST. PP•KS 02 3'-O'i — SEE REMARK _ SEE REMARK OL,KS R1 03 EXISTING — -- -- — -- -- OL,KS 04 EXISTING — -- -- — -- -- OL,KS 05 EXISTING — -- -- — -- -- OL,KS 06 EXISTING — -- -- — -- -- OL,KS 07 EXISTING — -- -- — -- -- — 08 EXISTING — -- -- — -- -- OL,KS 09 CASED OPENING DOOR/FRAME TYPES 3'-4" 0. p p r'TEMPERED w w GLASS, WOOD Ci y U FLUSH BEAD w \ STAINED TO y 0 0 \MATCH DOOR 0 o G IO \ O D1 D2 F1 F2 REMARKS GENERAL: ALL INTERNAL SUITE BRASS HARDWARE TO BE SWITCHED TO BRUSHED NICKEL. BE SALVAGED DOOR AND FROM DECONSTRUCTION NOTE D04. PROVIDE HARDWARE AS NOTED IN SCHEDULE. R2. COORDINATE COMMON HALLWAY SIDE OF FROM COLOR WITH LANDLORD. PROVIDE AND COORDINATE DOORBELL SYSTEM WITH TENANT AND TENANT'S SECURITY VENDOR. PROVIDE VINYL FILM ON DOOR AND SIDELIGHT. HARDWARE LEGEND CL CLOSER CH COATHOOK CR CA RD READE R BY TENANT(N.I.C.) DB DEADBOLT DL DUMMY LEVER EL ELECTROMAGNETIC LOCK (PER IBC 2012) ES ELECTRIC STRIKE BY TENANT(N.I.C.) H HOLD OPEN KP KICK PLATE KS KICK STOP OIL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES DOOR/FRAME NOTES I. REUSE DOORS FROM DECONSTRUCTION WHERE POSSIBLE; TOUCH UP EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING. PRE -MACHINE NEW DOORS FOR CYLINDRICAL LocKSErs. 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS, REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUI REMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: • 7'-0" HT. TO HAVE 3 HINGES • GREATER THAN 7-0 IN IN HT. TO HAVE 4 HINGES • FINISH TO MATCH HARDWARE SET 8. PROVIDE(1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE)AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. 0 E O �O O U N V 0 C n Z ^ 'E p o. O ^ O w O M V �C ES e 1D 'vwJ C THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC.. AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. U) aN r- J LL N I a" J J 0 m O z I W<< 0 N ^^</ ,,nn� v�U ZZ �O ao W L0 11.0 REVISIONS MARK DATE I Dill IN 0. AR10700017 STATE OF PROJECT NUMBER 2019.063 IPROJ. MGR DRAWN BY JJ JJ _ FIRST FLOOR DOOR SCHEDULE INTERIOR DETAILS A21 I LEGEND EXISTING TO BE REMOVED WALL EXISTING TO REMAIN WALL vxvxvx PARTIAL HEIGHT WALL � PARTIAL HEIGHT WALL i DOOR AND FRAME WINDOW / SIDELIGHT CEILING GRID AND 7_-_—r TILES, Z'x4' 1 1 CEILING GRID AND i--?--r TILES, 2'x2' F'T SUPPLY AIR DIFFUSERS e �v caum EXHAUST FAN L_J LIGHT FIXTURE, LL _rJJ FLUORESCENT, 2'x4' q=1 LIGHT FIXTURE, L_J11 FLUORESCENT, 2'x2' LIGHT FIXTURE, CAN P----, LIGHT FIXTURE, FLUORESCENT "fir+ LIGHT FIXTURE, TRACK tk LIGHT FIXTURE, LIGHT FIXTURE, 05) PENDANT $ LIGHTSWITCH EXIT LIGHT q�y^ C-] EMERGENCY LIGHT IBJ =1I ELECTRIC OUTLETS) DATA OR Ir COMMUNICATION OUTLET 77 DOOR AND FRAME x WINDOW/SIDELIGHT NOTE: EXISTING FIXTURES THATARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of CNmel DATE: 06/17/19 GENERAL NOTES I. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T 111. 2. ALL TEXAS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECTOR BUILDING IF POSSIBLE. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER TO THE DECONSTRUCTION MANAGEMENT CHECKLIST BELOW. 3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. 4. REMOVE EXISTING CEILING AND LIGHT FIXTURES THROUGHOUT SUITE, SEE DECONSTRUCTION MANAGEMENT CHECKLIST FOR MORE INFORMATION. DECONSTRUCTION MANAGEMENT CHECKLIST THIS CHECKLIST ONLY APPLIES TO ITEMS BEING REMOVED. REFER TO DECONSTRUCTION PLAN. CONTAINER: a ITEM BEING z u ¢ z REMARKS REMOVED co1�U Q } O p 3 �O u METAL LIGHT BOXES CASEWORK UNIT COORDINATE WITH BLDG. OWNER AND SDI FOR STORAGE LOCATION CARPET TILE ✓ CEILING TILES COORDINATE WITH BLDG. OWNER ON STORING FOR STOCK USE APPLIANCES COORDINATE WITH BLDG. OWNER AND PREVIOUS TENANT GENERAL SORTING REQUIREMENTS (AS APPLICABLE): CO -MINGLE RECYCLING CONTAINER: SHIPPING/PACKAGING, WOOD STUDS, WOOD TRIM, HVAC COMPONENTS, CEILING GRID, METAL STUDS, WIRING/ CONDUIT, AND OUTLEFS/SW ITCHES WASTE CONTAINER: DRYWALL, INSULATION, VINYL BASE AND LVT (LUXURY VINYL TILE) CONTACTS: KEUSE CARPET RECYCLING: COORDINATE PICK UP AND REQUIREMENTS WITH SUSAN SHAFER (3 V )33]-1950 ® AREA NOT IN CONTRACT ❑ AREA OF WORK PLAN NOTES miiiiiiiiiiiiiim D01 REMOVE EXISTING CABINETRY AND COUNTERTOP. D02 SALVAGE EXISTING SINK AND FAUCET. EXISTING PLUMBING LOCATION TO RAMAIN. NO SERVICE SINKS ARE BEING REMOVED. OSALVAGE EXISTING METAL ENTRY DOOR AND COORDINATE WITH D03 BUILDING OWNER ON STORAGE. SALVAGE DOOR AND FRAME AND RELOCATE TO CONFERENCE D04 102. SEE DOOR SCHEDULE FOR MORE INFORMATION. SALVAGE AND RELOCATE FIRE EXTINGUISHER TO NEW LOCATION D05 SHOWN ON At II. DECONSTRUCTION PLAN 0 2' 4' 8' 16' ■ THIS DRAWING. AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH OIT DESIGNLin aC4 r J LU H N a N N J J 0 m J Z 0 z I L.LJ N v�U ZZ �O ao W PROJECT NUMBER 2019.063 III MGR DRAWN BY JJ JJ FIRST FLOOR DECONSTRUCTION PLAN NC DIII LEGEND NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, DUPLEX POWER OUTLET, DUPLEX POWER OUTLET, POWER OUTLET, QUADRUPLEX QUADRUPLEX JQ JUNCTION BOX QJ JUNCTION BOX OCEILING MOUNTED CEILING MOUNTED JUNCTION BOX JUNCTION BOX ® BOX, BLANK COVER PLATE ® BOX, BLANK COVER PLATE Q BOX, OPEN QO BOX, OPEN P PROVIDE JUNCTION BOX P POWER AND DATA POLE D ABOVE CEILING FOR O POWER POLE CONNECTION, POWER POLE BY OTHERS. FLOOR BOX WITH POWER FLOOR BOX WITH POWER FI® AND DATA, FLUSH &b AND DATA, FLUSH MOUNTED MOUNTED FLOOR BOX WITH FLOOR BOX WITH ® JUNCTION BOX AND J 1i JUNCTION BOX AND DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED DATA/COMMUNICATION b OUTLET (PROVIDE BOX b DATA/COMMUNICATION AND PULL STRING ONLY) OUTLET DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42" HEIGHT OF ELECTRICAL OR DATA DEVICE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Calmel DATE: 06/17/19 GENERAL NOTES I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BV THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. PLAN NOTES OE01 PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANTS SECURITY CONTRACTOR, SEE DOOR SCHEDULE FOR MORE DETAILS. E02 COORDINATE NORTH END POWER FOR COPY EQUIPMENT WITH TENANT. PROVIDE POWER AS REQUIRED BELOW, GROMMET IN COUNTER FOR ACCESS.. E03 PROVIDE POWER AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR, E04 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT, E05 PROVIDE POWER AT THIS LOCATION FOR TENANTS APARTMENT COMPACT DISHWASHER" (PROVIDE DRAIN IF REQUIRED). PROVIDE POWER AS REQUIRED FOR TENANT'S DOORBELL SYSTEM E06 AT ENTRY DOOR. COORDINATE WITH TENANT AND TENANTS SECURITY VENDOR. EO] PROVIDE POWER FOR TENANT PROVIDED MICROWAVE, POWER TO BE CENTER IN SHELF. E08 COORDINATE SERVEWIT REQUIREMENTS WITH TENANT AND TENANTS IT VENDOR, E09 PROVIDE DUAL POWER/ USE RECEPTACLE AT THIS LOCATION. UAREA NOT IN CONTRACT UAREA OF WORK ELECTRICAL PLAN 0 2' 4' 8' 16' ■ Ra THIS DRAWING, AND hiE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOTTO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. U) QN r J ua Q N CV '7 J (J CD m J Z Q z I WC N Oh� 0U Z z O Q o W REVISIONS PROJECT NUMBER 2019.063 PROD. Ml DRAWN BY JJ JJ FIRST FLOOR ELECTRICAL PLAN NC E111 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CODE SUMMARY SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE PREVIOUS USE OF SPACE B(USINESS( OCCUPANCY CLASSIFICATION B(USINESS( CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA 35,178 SF/FLOOR X 1 3STORIES = 105,534 SF TOTAL PROJECT AREA 1,786 SF SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD OCCUPANCY CALCULATIONS GEN. OFFICE 1,786 SF 100 17 TOTAL OCCUPANTS IN PROJECT AREA 17 NUMBER OF EXITS REQUIRED:I PROVIDED:2 SPRINKLER SYSTEM(YES/NO( YES- EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 35,178 SF ACCESSORY AREA EXCEEDS 10% NO FIREWALLS, AND/OROCCUPANCY SEPARATIONS (IF REQUIRED( N/A ASHRAE90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN( BUILT BEFORE 19782 NO BUILDING CONSTRUCTION TYPE II-B EX RELEASED FOR CONSTRUCTION ❑ Subject to compliance with all regulations of State and Local Codes City Bf CaHmel (� �VT�U'�D*tiYWML_ DATE: \ 06/17/19 AREA NOT IN CONTRACT AREA OF WORK LEGEND LIFE SAFETY NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER Ep EXISTING ELECTRICAL PANEL LOCATION NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON EX MISTING MIT PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES(, FIRE EXTINGUISHER EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, ® EXIT SIGN INTERNATIONAL FIRE CODE, NFPA(. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR 44 DD INB EMERGENCY LIGHT TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE, — — — TRAVEL DISTANCE 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10, COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED GENERAL NOTES LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING COMMON CORRIDOR TO REMAIN, EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY PLAN 0 4' 8' 16, THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERFY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SOH OII DESIGN. U) QN r J ul Q N CV J J CD m Z OZ� CwC to G ,,nnh � v�U Z z O o W L0 11.0 REVISIONS MARR1 DATE I DB IN 0. AR10700017 STATE OF PROJECT NUMBER 2019.063 III MGR DRAWN BY FIRST FLOOR LIFE SAFETY IN <D L100 GENERAL PROJECT NOTES ].BUILDING CODE COMPLIANCE: ALL WORKS HALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFIN ED BY SECTION 601 OF THE INDIANA BUILDING CODE. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODES) FOR THEIR RESPECTIVE SCOPE OF WORK. ENSURE THAT ALL MATERIALS AN D LABOR ARE IN ACCORDANCE WITH THE BESTQUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 2. CONTRACTOR SITE VISITS: CONTRACTORS) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT, THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTORS) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 3. CONTRACTOR FIELD VERIFICATION: FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS, NOTED DIMENSIONS TAKE PRECEDENCE, VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GEN ERAL CONTRACTOR TO SCHOTT DESIGN, INC. 4. GENERAL CONTRACTOR COORDINATION WITH OWNER: THE GEN ERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON -SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURI NO HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION 15 DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. 5. PROJECT MATERIAL LEAD TIMES: FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE, THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 6. MATERIAL SUBSTITUTIONS: SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL N TBEA WED W PAP PROVAL THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIAT E SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. 7. SAFE WORK AREA: SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AN D THE PUBLIC AT ALL TIMES. B. GENERAL CONTRACTOR CLEANUP PROCEDURES: THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN ASAFE AND CLEAN ENVIRONMENT. 9. STAGING/ PARKING/ DUMPSTERS/ RESTROOMS: THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. 10. DUST CONTROL: THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS ® 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE, 11. PROJECT INSTALLATION CONFLICTS: CONTACTTHE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). 12. SCHOTT DESIGN HAZARDOUS MATERIALS WAIVER: SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. 13. WOOD BLOCKING IN WALLS: PROVIDE FIRE -TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC, 14. SHOP DRAWINGS: SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 15. PROJECT APPROVALS: ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER. 16. CHANGE ORDERS: REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES, FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE -BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT, RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Calmed DATE: 06/17/19 17. FURNITURE AND EQUIPMENT EXCLUSIONS: FURNITURE, OFFICE EQUIPMENT OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ON LV AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UN LESS SPECIFICALLY STATED TO BE PROVIDED, 18. WALL PATCHING: PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 19. CONSTRUCTION CLEANING: EXECUTE A THOROUGH FINAL CLEAN AND NSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCES WORK & DO NOT LEAK. 20, O&MMATERIALS: PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 21. PLAN DIMENSIONS: ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 22. WINDOW BLINDS: CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 23, PERMITTING: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, NSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 24, FIRE SEALING: FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE, BUILDING TYPE LISTED ON LIDO IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION. 25. WALL PENETRATIONS: WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRI BED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 26. FLOOR LEVELING: CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. 27, REPAIR GYPSUM WALLBOARD: WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS, 28. EQUIPMENT INSTALLATION: ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. FINISH NOTES 1. STATE BUILDING COMPLIANCE FOR FINISHES: ALL FINISHES SHALL COMPLY WITH CHAPTER (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. 2. GYPSUM ASSOCIATION CONFORMITY: FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.) PROVIDE NEW CEMENT BACKER BOARD AS A SUBSTRATE FOR NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS. 3. COVER PLATES: REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PUN FOR COLOR OF ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR TO PURCHASING NEW. 4. PAINTING: ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AN D TWO (2) FINISH COATS. 5. FLOORING TRANSITION STRIPS: FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN UNLESS NOTED OTHERWISE (I.E. WHERE VCT MEETS CARPET). 6. DELIVERY OF COMPREHENSIVE WORK PRODUCT: WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. WALL DEMOLITION: REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 8. TELEPHONE BOARDS: WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 9. MILLWORK SAMPLES: SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 10. INTERIOR ELEVATION DETAILS: REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION. 11. PAINT &ADHESIVE VOC'S: ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE ZERO VOC CONTENT, 12. ADHESIVE MANUFACTURER RECOMMENDATIONS: ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. MECHANICAL 8& ELECTRICAL NOTES I. DESIGN/BUILD MEP: THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO BASIC DESIGN -BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE DESIGN -BUILD CONTRACTORS FOR EACH TRADE MUST NOTI FV THE ARCHITECT IF THEY FI ND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL ELECTRICAL AND PLUMBING DESIGN -BUILD CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN -BUILD CONTRACTOR AND MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIGN -BUILD CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS, 2. DESIGN/BUILD HVAC: MECHANICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, 3. HVAC HEAT LOADS: VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT N THE TENANT SPACE, AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQUIPMENT, REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING OWNER/LANDLORD. CONTRACTOR TO ENSURE THAT ALL HVAC ZONES ARE LOCATED APPROPRIATELY SUCH THAT NO SPLIT ZONES ARE IN OFFICES OR CONFERENCE ROOMS. 4. HVAC DIFFUSER LOCATIONS: RELOCATE AIRSUPPLYDIFFUSERS AND RETURN -AIR GRILLES AS REQUIRED, PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. 5. HVAC THERMOSTAT LOCATIONS: POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS. 6. DESIGN/BUILD ELECTRICAL: ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND 15 OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. ELECTRICAL CODE COMPLIANCE: COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 8. ELECTRICAL CIRCUITING: SIZE AND CIRCUIT ELECTRICAL POWER ITEMS PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. 9. GIRL OUTLETS: ALL ELECTRICAL OUTLETS WITHIN 60 OF WATER ARE TO BE G.F.C.I. 10. PHONE AND DATA ACCOMMODATIONS: AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANTS DATA CONTRACTOR 15 RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. 11. ELECTRICAL SWITCH PLATES: PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCH PLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 12. WORKSTATION POWER: PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN. REFER TO THE PUN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS, CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BOXES. 13. LIGHTING CIRCUITS: VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. 14. ELECTRICAL OUTLETS: ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEETA.D.A. REQUIREMENTS. 15. LIGHTING SWITCH PLATES: WHERE MULTIPLE SWITCHES ARE SHOWN PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 16. LIGHT FIXTURE PLACEMENT: CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWNLIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXITSIGNS UNLESS OTHERWISE NOTED, 17. EMERGENCY LIGHTING: PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 18, FIRE ALARM SYSTEM: PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT I N CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE, 20. FIRE ALARM DEVICE LOCATIONS: COORDINATE WITH THE OWNER TENANT PRIOR TO INSTALLATION OF FIRE DETECTION DEVICES REGARDING ALL DEVICE LOCATIONS i0 AVOID CONFLICT WITH FEATURE WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT -INSTALLED ITEMS I.E. PRESENTATION BOARDS A V EQUIPMENT AND PROJECTION SCREENS). 21. MISTING LIGHT FIXTURE RELAMP: IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING SPACES. CONSULT WITH LANDLORD. 22. HVAC CONTRACTOR AIR BALANCE: CONTRACTOR TO PERFORM AIR BALANCE UPON COMPLETION OF HVAC SCOPE. PROVIDE REPORT TO LANDLORD. 23. HVAC FLEX DUCT: FLEX DUCT MUST MEET ASHRAE STANDARD BUILDING CODES FOR FLEX DUCT LENGTH. 24. ELECTRICAL CIRCUITS: AREAS WITHIN ELECTRICAL SCOPE MUST BE POWERED BY THE ELECTRICAL PANEL FROM THE FLOOR ON WHICH CONSTRUCTION OCCURS. 25, SUPPLEMENTAL HVAC/ELECTRICAL: IN THE EVENT THAT ANY SUPPLEMENTAL HVAC EQUIPMENT OR ABOVE BUILDING STANDARD ELECTRICAL POWER FACILITIES ARE INSTALLED (SUCH AS IN AN IT SERVER ROOM) CONTRACTOR SHOULD FURNISH AND INSTALL ADDITIONAL ELECTRICAL AND BTU SUB -METERING SO AS TO ENABLE OWNER TO MONITOR TENANTS UTILITY CONSUMPTION (IN RELATION TO THE SU ELECT EQUIPMENT) GOING FORWARD. THE MAKE AND MODEL OF CONTRACTOR'S PROPOSED METERS SHOULD BE REVIEWED AND APPROVED BY OWNER PRIOR TO CONTRACTOR INSTALLATION. 26. ENGINEERED MEP DRAWINGS: WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTORS) SHALL PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR FIRE SUPPRESSION. DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW, 27. EQUIPMENT INSTALLATIONS: ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS, 28. BUILDING DIRECTORY: THE BUILDING AUTOMATION SYSTEM GRAPHIC AND PROGRAMMING TO BE UPDATED WITH NEW TENANT'S INFORMATION FOR FUTURE USE. 29. ELECTRICAL PANELS: ALL ELECTRICAL PANELS TO GET UPDATED CIRCUIT SCHEDULES. FIRE PROTECTION NOTES I. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER, THE FOLLOWING NOTES APPLY ON LV IN EXISTING SPRINKLERED FACILITIES. 2. DESIGN BUILD FIRE PROTECTION SYSTEM: FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT, PROVIDE A COMPLETE, WORKING SYSTEM, SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FORTHE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 3. FIRE PROTECTION SYSTEM CODE COMPLIANCE: THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 4. FIRE PROTECTION DESIGN DRAWINGS: THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. SPRINKLER HEADS: PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED, PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. DOCUMENT APPROVAL DECONSTRUCTION NOTES I. DECONSTRUCTION DEFINITION: CAREFULLY DISMANTLE SPACES WITH THE GOAL OF MAXIMIZING THE REUSE POTENTIAL OF ITS COMPONENTS, 2. DECONSTRUCTION MANAGEMENT CHECKLIST: ALL ITEMS SHOWN ON THE DECONSTRUCTION PLAN HAVE BEEN CAREFULLY CONSIDERED FOR RECOVERY, REUSE, AND RECYCLING WITH THE BEST INTENT TO DIVERT ITEMS FROM THE LANDFILL. REFER TO DECONSTRUCTION MANAGEMENT CHECKLIST FOR SPECIFIC INSTRUCTIONS. 3. RECYCLING: GENERAL CONTRACTOR IS RESPONSIBLE FOR RECYCLING ANY AND ALL POSSIBLE PROJECT MATERIAL WASTE AND COORDINATING THE APPROPRIATE HAULING CONTAINERS WITH THE WASTE MANAGEMENT SUB -CONTRACTOR. 4. MISTING STRUCTURAL ELEMENTS OF BUILDING: NO STRUCTURAL OR LOAD -BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS, PROTECT ALL EXISTING STRUCTURAL MEMBERS DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL CONTACTSCHO T DESIGN IMMEDIATELY IF THE CONTRACTORS) IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD -BEARING, BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIN D FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 5. EQUIPMENT, FIXTURE, FINISH REUSE: WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 6. DECONSTRUCTION PLANS: REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES, NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DECONSTRUCTION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DECONSTRUCTION. 7. FIELD VERIFICATION OF EXISTING CONDITIONS: REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN, 8. PROTECTION OF BUILDING ELEMENTS TO REMAIN: USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE CONTRACTOR SHALL REPLACE AND OR REPAIR AT THE CONTRACTOR'S COST ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 9. REMOVAL OF ABANDONED CABLING& WIRING: PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION) REMOVE ALL ACCESSIBLE PORTIONS OF ABANDON ED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES RACEWAYS, AND PLTC CABLES REFER TO SECTION 300.21. ANYSUCH CABLE OR WIRING SHOULD BE PULLED AND REMOVED BACK TO THEIR MAIN SOURCES ON THE FLOOR (I.E. ELECTRICAL PANELS, PHONE BOARDS, ETC.) 10. PROTECTION OF ABANDONED/TERMINATED BUILDING SYSTEM ELEMENTS: WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN "AS -BUILT' SEE INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 11. HAZARDOUS MATERIALS: GENERAL CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ANY AND ALL ITEMS THAT MAY CONTAIN HAZARDOUS OR HARMFUL MATERIALS. ALL IDENTIFIED ITEMS MUST BE PROPERLY DISPOSED OF PER EPA AND INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT RULES AND REGULATIONS. 12. COSTS: GENERAL CONTRACTOR TO PROVIDE ANY COST RELATED TO SORTING AND RECYCLING, AS WELL AS ALL SCRAP METAL INCOME, AS PART OF THE DEMOLITION/DECONSTRUCTION BASE BID. 13. RECEIPTS: GENERAL CONTRACTOR MUST OBTAIN AND PROVIDE TO OWNER RECEIPTS ON ALL RECYCLED ITEMS INCLUDING CREDIT FOR METALS, TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. TENANT/CLIENT COMPANY NAME DATE TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT. THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. _MILL/CASEWORK NOTES 1. CASEWORK/MILLORK: CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GEN ERAL CONTRACT. 2. AWI COMPLIANCE: UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 3. MILLWORK SHOP DRAWINGS: FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AN D SCHOTT DESIGN PRIOR TO FABRICATION. 4. MILLWORK FIELD VERIFICATION: WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS -BUILT CONDITIONS IN FIELD. REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 5. DRAWING REVIEW AND DISCREPANCIES: VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES, IMMEDIATELY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GEN ERAL CONTRACTOR. 6. MILLWORK REQUIREMENTS: REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS(CUSTOM PLASTIC LAMINATE OR PRE -MANUFACTURED STOCK CABINETRY). EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE. 7. MILLWORK WALL BLOCKING: TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED. .9 Ans ,I e,Inrnn"9unnRi ,... -�s v a....c.e9 We Ap c.«.c,.., .Q c 9aromm�wero d x ,.m R e.1✓ „p9 �a 1.9 9i,...9'"' VICINITY MAP NOT TO SCALE KEY PLAN - 1 ST FLOOR N NOT TO SCALE C INDEX OF DRAWINGS TIII COVER SHEET AND GENERAL PROJECTNOTES LI00 LIFE SAFETY PLAN DI I I DECONSTRUCTION PLAN At I I ARCHITECTURAL FLOOR PLAN A121 REFLECTED CEILING PLAN A131 FINISH PLAN A211 DOOR SCHEDULE/ INTERIOR DETAILS EIII ELECTRICALPLAN THIS DRAWING. AND ME IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT ME WRITTEN CONSENT OF SCHOTT DESIGN. aN r J LU H N a1 N J � o J �O m J Z Q OZ 1 Ow N H UJ Q OU ZZ R� O U ao W LO LO REVISIONS PROJECT NUMBER 2019.063 PROJ. MGR DRAWN BY JJ JJ FIRST FLOOR COVER SHEET AND GENERAL NOTES T I I I