HomeMy WebLinkAboutSHEET S303 - Shoppes on Main Retail Building (Carmel, IN) 19SEE NOTES
GROUT ALL
VERTICAL ST
FULL HEIGHT
Ni
1. PROVIDE HORIZONTAL REINFORCING IN ALL WALLS.
2. PROVIDE ADDITIONAL BARS AT WALL INTERSECTIONS AND CORNERS
AND AS SHOWN ON DETAILS.
3, GROUT ALL CORES BELOW FINISHED FLOOR ELEVATION.
4, LAP HORIZONTAL JOINT REINFORCING 16" AT SPLICES.
WALL REINFORCEMENT
SCALE: NONE
REINFORCE TWO
CORES AS SHOWN
CORNER
VERTICAL REINFORCEMENT PER
ELEVATION THIS SHEET
I WIN 1i f
JAMB
VERT. PONE (COLT
THEN BOND BEAM)
CORE
WITH
BOND BEAM
-2 w5 TONS
REINFORCING
#3 SPACERS 0 48" O.C.
PROVIDE BOND BEAMS WHERE SHOWN ON
ARCHITECTURAL AND STRUCTURAL PLANS AND
SECTIONS.
BOND BEAM
NNN
SCALE: NONE
REINFORCEMENT DETAILS
SCALE: NONE
NOTES:
1. REINFORCING SHOWN IS IN ADDITION TO REINFORCING SHOWN ON PLANS AND SPECIAL DETAILS.
2. REINFORCING SIZE SHALL MATCH TYPICAL WALL REINFORCEMENT.
1/2'0 x 6" HEADED STUDS WELDED
TO TOP OF LINTEL BEAM. PLACE (1)
DIRECTLY OVER BEARING, BALANCE
AT 32" O.C. (MAXIMUM). GROUT FIRST
COURSE ABOVE LINTEL BEAM SOLID
fl
8"
PROVIDE HORIZONTAL
JOINT REINFORCEMENT
WHERE SHOWN
FEEL PER PLAN
-SHRINK GROUT
(2) 1/2"0 ANCHORS
(SPACE AT BEAM GAGE)
3"
REINFORCEMENT PER
DETAILS AND ELEVATIONS
THIS SHEET_
REAM I INTFL BEARING
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Caimel
DATE: 06/17/19
PONE.BALL THE WAY
TO CORNER
CORNER
2 #5 - 30%30"
EXTEND BOND BEAM
REINF. ALL THE WAY
TO EDGE
INTERSECTION
BOND BEAM REINFORCING
SCALE: NONE
CMU WALL & FEINT. PER PLAN
w
`_
I
TOP OF RIG OR SLAB
DOWEL SIZE & SPACING TO
MATCH WALL REINFORCING
STD HOOK
L
REBAR SPLICE
AT FOUNDATION
NOT TO SCALE
SPACING PER PWJ CONTROL JOINT
ONE SIDE OF
OPENING
VERT. REINE. (SAME
SIZE AS VERT. WALL
REINFORCING)
PROWDE ANCHORS UCH L
SE£ STEEL NNTEL REARM
DEwL NOT REQUIRED Wm
LOOSE ARGUE LINTELS
2 j)6 VERT. EACH C
(4 CORES TOTAL)
8" DEEP BOND BEAI
(OMIT AT D00R OP6
5011
mmmmonm
51m1
Mmm
I■1
I■m1I-mmi
Im
1
OmnMmmT0NY■Y
M1aiu
M
mn
mm
Im������F,�mi
I
-�1�A1-I-III
-.Illlln
mlII
CONTROL JOINT MATERIAL
DUR-O-WALL D/A 2001,
D/A 2003 OR EQUAL
SPACING PER PLAN �, REINFORCE WALL EACH SIDE
OF JOINT. BAR SIZE TO MATCH
TYP. WALL REINFORCEMENT
PLAN
MASONRY CONTROL JOINT NO7ES:
1, SEE ARCH. BASS. FOR CONTROL
JOINT LOCATIONS. MAXIMUM
SPACING OF JOINTS = 20'-0".
2, DISCONTINUE HORIZONTAL
JOINT REINFORCING AT CONTROL
JOINTS,
3, STOP BOND BEAM REINFORCING
2" FROM CONTROL JOINT.
ADD 3'-0" DOWEL x REINFORCING SIZE.
BREAK BOND WITH MASTIC ON DOWEL
FOR 18" ONE SIDE OF JOINT,
LI L\/ATIfIIJ
MASONRY CONTROL JOINT
SCALE: NONE
TYP. REBAR SPLICE
NOT TO SCALE
SPACING Pro of .K,
VERT. REINE (SAMI
SIZE AS VERT. WA.
REINFORCING)
2 #6 VERT. EACH
(4 CORES TOTAL)
8" DEEP BOND BE
(OMIT AT DOOR OF
WALL OPNG W/ STEEL LINTEL WALL OPNG W/ PRECAST LINTEL
SCALE NONE SCALE: NONE
MASONRY CONSTRUCTION
REINFORCING BAR
LAP SPLICE SCHEDULE
BAR SIZE
LAP LENGTH
#3
1'-9"
#4
2'-3"
#5
2'-9"
#6
4'-9"
7'-6"
#7
KWIK BOLT 3 EMBEDMENT
DIAMETER
MINIMUM EMBEDMENT
3/8"
21/2"
3 112"
4"
1/2"
5/8"
3/4"
4 3/4"
LOOSE LINTEL SCHEDULE
OPENING SIZE
ANGLE SIZE
REMARKS
UP TO 4' HON
L 4x4xl/4
PROVIDE 4" BEARING
EACH END
4'-I" TO 6'-0"
L 6x4x5/16
PROVIDE 4" BEARING
EACH END
6'-I" TO 9'-0"
L 7x4x3/8
PROVIDE 4" BEARING
EACH END
GENERAL MASONRY NOTES
1. CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH IBC CHAPTER 21 THE
LATEST EDITION OF THE "BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY
STRUCTURES" (ACI 530).
2. CONCRETE MASONRY CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION OF THE
"SPECIFICATION FOR CONCRETE MASONRY CONSTRUCTION" (ACI SEEL).
3. CONCRETE MASONRY CONSTRUCTION SHALL BE INSPECTED AS REQUIRED BY THE
"SPECIFICATION FOR CONCRETE MASONRY CONSTRUCTION" (ACI 530.1). SEE SHE F101
4. CONCRETE MASONRY CONSTRUCTION SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH
(F'M) OF 1,500 PSI AT 28 DAYS.
5. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90-03. COMPRESSIVE STRENGTH
OF MASONRY UNITS SHALL MEET OR EXCEED 1900 PSI.
6, MORTAR SHALL BE TYPE M BELOW GRADE AND TYPE M OR S ABOVE GRADE
PROPORTIONED IN ACCORDANCE WITH THE LATEST EDITION OF ASTM C270 OR C476.
7, MASONRY CORES WITH REINFORCEMENT, BOND BEAMS AND OTHER CORES SHOWN TO BE
FILLED WITH GROUT SHALL BE FILLED WITH A COARSE GROUT WITH A MINIMUM 2,500 PSI
COMPRESSIVE STRENGTH AT 28 DAYS, 3/4" MAXIMUM AGGREGATE AND 8" SLUMP,
8. GROUT NET HEIGHTS SHALL NOT EXCEED 5'-0". GROUT POUR HEIGHTS SHALL MEET
THE REQUIREMENTS OF ACI-530,
9. REINFORCING STEEL SHALL BE DEFORMED BARS OF NEW BILLET STEEL CONFORMING
TO ASTM A615-07 WITH A MINIMUM YIELD STRENGTH OF 60,000 PSI.
10. REINFORCING BAR DETAILING, FABRICATING, AND PLACING SHALL CONFORM TO THE
LATEST EDITION OF "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" (ACI
301),
11. REINFORCEMENT BARS SHALL NOT BE TACK WELDED, WELDED, HEATED OR CUT
UNLESS INDICATED ON THE CONTRACT DOCUMENTS OR APPROVED BY THE STRUCTURAL
ENGINEER.
12, PROVIDE DOWELS FROM FOUNDATION INTO REINFORCED CMU. DOWELS SHALL EXTEND
INTO THE CMU PROVIDING A LAP SLICE OF THE LENGTH SPECIFIED IN THE SCHEDULE
FOR THAT SIZE REINFORCEMENT BAR.
13. AT SPLICES OF REINFORCEMENT BARS PROVIDE A LAP SPLICE. LENGTH OF SPLICE
SHALL BE PER SCHEDULE ON THIS SHEET.
14, PROVIDE GALVANIZED STEEL WIRE JOINT REINFORCEMENT IN ALL MASONRY CONSTRUCTION.
REINFORCEMENT SHALL BE CONTINUOUS AND BE LAPPED SIXTEEN INCHES AT SPLICES.
CUT REINFORCEMENT AT ALL CONTROL AND EXPANSION JOINTS. SPACE REINFORCEMENT
AT 8" ON CENTER FOR PARAPETS, BELOW BUILDING FLOOR ELEVATION AND STACK BOND
CONSTRUCTION. ELSEWHERE SPACE REINFORCEMENT AT 16 INCHES ON CENTER.
HORIZONTAL REINFORCEMENT SHALL BE TRUSS TYPE WITH W1.7 WIRES.
15. MAINTAIN VERTICAL BAR POSITION DURING GROUTING OPERATIONS. BAR POSITIONERS
SHALL BE DUR-O-WALL D/A 815 OR 817 (ONE BAR PER CORE) OR D/A 816 (TWO
BARS PER CORE) OR EQUAL. PROVIDE POSITIONERS AT 48" ON CENTER. PROVIDE A
MINIMUM OF TWO POSITIONERS PER BAR.
16, AT BEAM BEARINGS PROVIDE TWO 1/2" DIAMETER X V-3" HOOKED ANCHORS. SPACE
ANCHORS AT STANDARD GAGE FOR BEAM.
17. BEAMS, LINTELS, JOISTS, ETC. SHALL BEAR ON BOND BEAMS OR REINFORCED HOLLOW
MASONRY UNITS WITH CORES FILLED SOLID WITH GROUT. SEE DRAWINGS FOR OTHER
REQUIREMENTS.
18. PROVIDE BOND BEAMS WHERE SHOW ON ARCHITECTURAL & STRUCTURAL DRAWINGS.
19, PROVIDE LINTELS AT ALL OPENINGS IN MASONRY WALLS. NOT ALL OPENINGS ARE
SHOWN ON THE STRUCTURAL DRAWINGS. SEE THE ARCHITECTURAL DRAWINGS FOR
MASONRY WALL OPENING LOCATIONS AND SIZE.
20. ANCHORS USED IN MASONRY CONSTRUCTION SHALL BE KWIK BOLT 3 EXPANSION
ANCHORS BY HILTI . ANCHORS SHALL BE INSTALLED A MINIMUM OF 12" FROM THE END
OF A MASONRY WALL. DO NOT INSTALL ANCHORS WITHIN 2" OF VERTICAL JOINTS. SEE
DETAILS FOR DIAMETER OF ANCHORS. EMBED IN MASONRY PER THE FOLLOWING CHART.
MASONRY CORES WHERE ANCHORS ARE PLACED SHALL BE GROUTED SOLID.
21. WHEN FILLING IN OPENINGS IN EXISTING
CMU,
EXTENDING AN
EXISTING WALL, OR
BUILDING A NEW WALL PERPENDICULAR TO
EXISTING
CMU, TOOTH IN NEW CMU AND
REINFORCE COMMON CORE WITH ONE #6
BAR
VERTICAL AND
GROUT CORES SOLI -
LINTEL SCHEDULE
SEE STRUCTURAL DWGS FOR LOCATIONS
MARK
SIZE
REMARKS
NN
SPAN
LI
PC8-8
@ 8" CMU W/
@ 12" CMU W/
PL 5/16" x 7
PE. 5/16" x II
112"
112"
T &
T &
B
B
UP TO 4'
4' TO 8'
L2
W8x24
L3
W16x26
@ 8" CMU W/
PL 5/16" x 7
1/2"
T &
B
8' TO 14'
L4
W16x4O
# 12" CMU W/
PL 5/16" x II
112"
T &
B
14' TO 20'
NOTE:
EXTEND WIDE FLANGE LINTELS 1'-4" PAST OPENING ONTO BEARING PLATE. REINFORCE CMU WALL
W/ (2) #6 EA. CORE 0 12" WALL, (2) T5 EA. CORE 0 8" WALL
NN
PRECAST LINTEL PROPERTIES
MARK
SIZE
WxH
EI NF.
F'o
OVN
OMN
lap
BOT.
PC6-8
6x8
1 #4
1 #5
3,500
3,320
59,570 IN -LB
PC8-8
8x8
2 #4
2 #5
3,500
4,450 LB
167,150 IN -LB
PC8-16
8x16
2 #4
2 #6
3,500
10,540 LB
598,090 IN -LB
LINTEL NOTES.
SEE DETAILS FOR REQUIRED BEARING
PRECAST LINTELS MUST HAVE REINFORCEMENT AND STRENGTH NOTED ABOVE. PRECAST LINTELS
SHALL BE MARKED TO INDICATE TOP OF LINTEL. REINFORCEMENT SHALL BE 1-1/2" CLEAR FROM
TOP AND BOTTOM OF PRECAST LINTEL.
STEEL UNTELS IN EXTERIOR WALLS SHALL BE HOT DIPPED GALVANIZED (G90).
STEEL HOTELS IN INTERIOR WALLS SHALL BE SHOP PAINTED WITH A PRIMER AND A TOP COAT.
Z
O
r
O
O
IN.
IN
No
r
N
N
Q
6
O
a
O
d
•
?
x
Cm
U
Ne
W
J
Y
a
U
a
J°"z
•
co)
Z
L�J
W Z
Z
w
am
a
O
U)
H
W
0
z
Z
0
a
# DESCRIPTION DATE
E.
My� %
IWO
=, PE101W237
Ao. STATE OF 4rw
1• ,'�A �hDUNa '�4 .
l"EclONA/LV�yV�"P
STATE SUBMITTAL
APRIL 10, 2019
18148
S303