Loading...
HomeMy WebLinkAboutSHEET S332 - Shoppes on Main Retail Building (Carmel, IN) 23FULL WELDED FRAME L4 X 4 X 1/4 TOP FLUSH JOIST TOP CHORDS ----W/ II I II 11 11 I I I I I r 1 i � OUTLINE OF RTU CURB TYPICAL MECHANICAL UNIT SUPPORT NOTES: ROOF DECK OMITTED FOR CLARITY USE THIS DETAIL WITH NOS JOISTS FRAME AND DECK OVER OPENING SHALL BE INSTALLED AS PART OF STEEL ERECTION. SUBCONTRACTOR USING OPENING SHALL REMOVE DECK AND IS RESPONSIBLE FOR PROVIDING APPROPRIATE FALL PROTECTION. VERIFY SIZE AND LOCATION OF RTU WITH MECHANICAL CONTRACTOR PROVIDE ANGLE FRAMES UNDER CURBS AND AROUND OPENINGS IF OPENINGS ARE NOT THE SAME SIZE AS THE CURB. 5/16 V BASE PLATE — PER SCHEDULE P PLAN FRAME AT ROOF HATCH PER PUN LEVELING NUTS II 7I" TYP. (4) 3/4"0 ANCHOR RODS `ASTM F1554 GRADE 36 L A (Fu = 58 KSI) 5 _ Jh � 1'-5° SECTION BASE PLATE SCHEDULE COLUMN BASE PLATE W8 PL 3/4" x 14" x I'-2" WIO PL 3/4" x 16" x 1'-4" RELEASED FOR CONSTRUCTION TYPICAL W COLUMN Subject to compliance with all regulations of State and meal Codes City of Carmel �N;T��3tax�A�A� DATE: 06/17/19 OR SKYLIGHT NOTES: 1. DECK OMITTED FOR CLARITY. 2. FRAME SHALL BE INSTALLED AS PART OF STEEL ERECTION. 3. DECK SHALL BE INSTALLED OVER THE OPENING. 4. SUB -CONTRACTOR USING OPENING SHALL REMOVE DECK AND IS RESPONSIBLE FOR PROVIDING ADEQUATE FALL PROTECTION. 5/16 V 0- BASE PLATE — PER SCHEDULE PLAN 2" TYP. IF THIS DIMENSION IS MORE THAN 4" ROOF DRAIN OR OVERFLOW DRAIN ADD (2) L2x2x3/16 AS SHOWN. WELD SEE NOTES ON DWG, S102 TO TOP & BOTTOM CHORDS (FURNISHED (SEE PLUMBING DRAWINGS FOR AND INSTALLED BY MUCH. CONTRACTOR) ! T, OF PANEL POINT OPENING SIZE AND LOCATION) r✓ SUPPORT ANGLE L2262214 TYP. EACH SIDE BY STEEL SUPPLIER TYPICAL ROOF DRAIN JOIST PARALLEL TO BEAM TYPICAL "KICKER" - K DO PUN (4) 1"0 ANCHOR RODS x 2'-3" N ASTM F1554 GRADE 36 (To (Fu = 58 KSI) z� SECTION BASE PLATE SCHEDULE COLUMN BASE PLATE AID PL I" x I8" x 1'-6" :i ZED] =:%v�A»_AIq L An TYPICAL JOIST WEB REINFORCING AT RTU FRAME VERIFY WITH JOIST SUPPLIER L3x3x1/4 WELD TO JOIST AT TOP CHORD PANEL POINT -t 11141161 a a 4:19 4119 [oil] W_1:111 iH -71_1 ly, �& OF PANEL POINT .W_. l SEE PLAN FOR LOAD )WIN WELD TO TOP & BOTTOM CHORDS TYPICAL JOIST WEB REINFORCING AT CONCENTRATED LOAD HUNG FROM BOTTOM CHORD 0 z z O DLU rrnnF- U) � Z � O O O N i N Q W p z a X U > W J Y a Q 0= o a an z L•J Z z LU W am 2 am Ell Q O # DESCRIPTION DATE E. My� IptO w PEIOIW227 ', • - Ao. STATE OF 4r": a,'A�e'1hD�ANR ��: 'S'OONNAL V�7 STATE SUBMITTAL APRIL 10, 2019 18148 S332