HomeMy WebLinkAboutSHEET S333 - Shoppes on Main Retail Building (Carmel, IN) 24o =m � o 1/2" ~ 112 4° MAX. o NO COPE TOP FLANGE COPED TOP & BOTTOM FLANGE COPED TYPICAL BEAM CONNECTION DETAILS PER SCHEDULE �k PER SCHEDULE STIFFENER PLATE PER SECTION PLATE t FILLET WELD 1/4 3/16 5/16 1/4 3/8, 1/2, 5/8, 3/4 5/16 V 3/S TYPICAL STIFF PLATE & WELD SCHEDULE SEE SECTION FOR FORCE t TYPICAL ANGLE CONNX TO JOIST TOP CHORD PANEL POINT - JOIST PARALLEL RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel DATE: 06/17/19 ALLOWABLE SERVICE LOADS (Kipsl in In Bolts 2 6" 8.2K 3 9" 16.3K 4 12" 26.1K 5 15" 36.3K 6 18" 46.3K 7 21" 56.4K Notes: 1) The capacity of the connection shall be the lesser of A) Bolt Capacity B Weld Capacity C Supporting Plate Capacity D Web Net Shear 2) Refer to ABC ASO — Manual of Steel Construction (Part 1). 3) Allowable bolt capacity is based on 3/4"0 A325—N Type bolls. 4) For coped beam connections, the capacity o' Lhe ^a; -hen, area of the web shall be verified. STANDARD BEAM SHEAR TAB CONNECTION DETAIL ASD DESIGN SCALE: NONE t WEB min. = 0.51" FOR A36 BEAMS (NOTE 2) 0.37" FOR DR. 50 BEAMS 1/�` E70XX DOUBLE L 4x3 1/2"x5/16" ALLOWABLE SERVICE LOADS (Kipsl n L in Bolts Welds (Note 2) 2 5 1/2" 37.1K 49.5K 3 8 1/2" 55.7K 73.7K 4 11 1/2" 74.2K 97K 5 14 1/2" 928K 118K 6 17 1/2- 111K 139K 7 20 1/2" 130K 158K Notes: 1) The capacity of the connection shall be the lesser of: A) Bolt Capacity B Weld Capacity C Connected Plate Capacity D Block Shear 2) Allowable weld capacity is based on web thicknesses nolel above. Ratio this capacity for lesser web thicknesses_ 3) Allowable bolt capacity is based on 3/4"0 A325—N Tyo_ 4) Block shear should be checked for coped beams STANDARD DOUBLE ANGLE CONNECTION DETAIL ASD DESIGN SCALE: NONE BEAM CONNECTION NOTES 1, BEAM TO BEAM CONNECTIONS MAY USE SHEAR TABS. IF BEAM REACTION EXCEEDS 100 KIPS, A DOUBLE ANGLE CONNECTION IS REQUIRED. 2. CONNECTION OF BEAMS TO COLUMN FLANGES MAY USE A SHEAR TAB EXCEPT AT BEAMS ON GRIDS WITH BRACES. BEAMS ON SAME GRID LINES AS BRACES SHALL USE A DOUBLE ANGLE CONNECTION. 3. CONNECTION OF BEAMS TO COLUMN WEBS MAY USE DOUBLE ANGLE CONNECTIONS OR EXTENDED SHEAR TABS, EXCEPT AT BEAMS ON GRIDS WITH BRACES. BEAMS ON SAME GRID LINES AS BRACES SHALL USE A DOUBLE ANGLE CONNECTION. 4. IF BEAM REACTIONS ARE NOT SHOWN ON THE PLAN, DESIGN CONNECTIONS FOR 1/2 OF THE UNIFORM LOAD CARRYING CAPACITY OF THE BEAM. 5. DESIGN CONNECTIONS OF BEAMS IN LINE WITH BRACES FOR AXIAL TENSION SHOWN ON PLAN IN ADDITION TO THE SHEAR LOAD. 6. CONNECTION CHARTS REQUIRE USE OF A-325N BOLTS. 7. HOLES MAY BE STANDARD OR SHORT —SLATTED TRANSVERSE TO DIRECTION OF LOAD. 8. THE MINIMUM NUMBER OF ROWS OF BOLTS SHALL AS SHOWN IN THE TABLE BELOW: WS 2 ROWS WIO 2 ROWS W12 2 ROWS W14 3 ROWS W16 3 ROWS W18 3 ROWS W21 4 ROWS W24 4 ROWS W27 5 ROWS W30 5 ROWS W33 6 ROWS W36 6 ROWS C) z z O aaaaaaa� � LW r D W H U/ Q Z � O O O N i N MIX go Inv 0 z a a x p '+ x V) U W Y O I a IN z C= o a m an z Z C1 O U W 0 Rw w ImI 6 `m 6r W c y m W W o Z � N z300 W n ^ Z O z Z LIJ W SEE SECTION FOR FORCE aQ � 1 SEE SECTION FOR 3/16 O f..1 ANGLE ,,^^ v! C7 JOIST PER PLAN Z LL -o J TYPICAL ANGLE CONNX TO U a a W ANGLE SPANNING JOISTS ~° OR BEAMS X DESCRIPTION DATE E. MY�% w PHIOIW227 ', • - ry �0'. STATE OF 'WW: a,'w�e'1hD/ANR : 1111 STATE SUBMITTAL APRIL 10, 2019 18148 S333