HomeMy WebLinkAboutSP-2POOL DATA 29'-10'' X 55' SPA DATA 20' X 30' POOL CIRCULATION: SPA CIRCULATION: MAIN POOL: SURFACE SQ. FT. '053 SURFACE SQ FT. 699 PERIMETER LIN. FT. IT9"-8" PERIMETER LIN. FT. 32'-4" H2O OAP. OU FT 4039 H2O OAP. OU FT 134b H2O CAP. GAL. 30210 H2O CAP. GAL. I,006B FLOW RATE - GPM II8 FLOW RATE - GPM 48 TURN OVER HRS. 421 TURN OVER HRS. .35 TANNING SHELF. SURFACE Sa FT. B20 PERIMETER LIN. FT. 06' H2O CAP. CU FT 140 H2O CAP. GAL. 1,045 FLOW RATE - GPM 10 TURN OVER HRS. ITS PIPING LEGEND: MAIN DRAIN — — SKIMMER RETURN INLET ——— —— MAKE UP WATER . VACUUM LINE WATER LEVEL NOTE: I. ALL PVC PIPES SHALL ISE ASTM 01185/16 SCHEDULE 40. 2. ALL EXPOSED PIPING SHALL 5E LABELED RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/27/19 POOL FLOW RATES POOL MAN DRAIN GRATE VELOCITY . 28 X 0321 458 SQ EA VELOCITY = 291 FPS POOL SUCTION PIPE VELOCITY 128 X 0321 3"0 101 VELOCITY . 5B1 FPS POOL RETURN LINE VELOCITY = II8 x 0321 25"0 4.91 VELOCITY = 1.1 FPS FEATURE FUMP FLOW RATES POOL MAN DRAIN GRATE VELOCITY = 215 X 0321 45B SQ EA VELOCITY = B2 FPS FOOL SUCTION PIPE VELOCITY . 215 X 0321 3'0 ,Z1 VELOCITY = 536 FPS SHEAR FOUNTAIN RETURN LINE VELOCITY . Sa X 0321 2"0 314 VELOCITY, 92 FPS SPA FLOW RATES SPA THERAPY FLOW RATES VELOCITY = 146 X 0321 83AO 80 EA VELOCITY = 56 FPS SPA SUCTION PIPE THERAPY SUCTION PIPE VELOCITY . 48 X 0321 VELOCITY . W X 0321 2110 3.14 3110 721 VELOCITY = 4.9 FPS VELOCITY = 4.45 FPS SPA RETURN LINE SPA THERAPY LNE VELOCITY = 48 X 0321 VELOCITY = 98 X 0321 2110 3.14 2110 3.14 VELOCI = 4.3 FPS VELOCITY = 10 FPS (2) SPA RETURN N-ETS (9) SPA THERAPY INLETS 24 X 0321 VELOCITY VELOCITY IOB X 0321 . 3/4'0 .44 IR"0 2 VELOCITY = n5 FPS VELOCITY = 113 FPS �I I"lilllllll �' I'�I�'llllll wlru wllsllal l l l l E1358LERi 25 GPM EA = 125 GFM E I z I D l I I E I wpwo SHEAR FOUNTAIN 15 GPM PER FT = 90 GPM I S �Y TOTAL 215 GPM -I §IE ¢II ICI I IIII .�II�I�I I II�I�IIIIII I i I a�IIIII z I� .IEIact la ��IQIQI� I I "I IT T — — — — — — — — — — — — — -- 1 9 - QI 1 _ r- I LIGHT LIGHT _ 1 � 46 ♦ p_0 — — a n s a, e SHEAR FOUNTAIN 40:_0n m I - o Y'-0" 1'-0e 2'-011 5'-0" 10'-0" 9 LIGHT LIGHT � uP I II I I I �' IIIIII I ---III IIIIII __ �I'Illlll IIIII I I IIIII i IIIII I IIIII _ I III IIIII �I IIIII - �IIIII IIIII 3:� IIIII — — — — — I IIIII I-m 0 _IIIII __ _--------- ---- _--_—�JiI IIi------�� \ -- — — — -- — — -- — — — — — — — —�---- LED LIGHTS 0 BUBBLERS COURTYARD POOL PLAN �•. SPA THERAPY PIPING 2 SCALE: 3/16" = 1'-0" J J a�A moo. 870137 STATE c*P o" i'N11Ta n " 1� N r` `D � f O �E: s � rn U � ' I U v a 0 e 0 o s' Q p e C= — 3 s O U E H Y W i v C..> L - O i y c � = a a CU C= A Q o JOB TITLE W V) J z o 0 Z w a a ?) z o: a 0 aJ U J 0 JOB NO. 18102-07 DATE 05/22/18 REVISIONS 112/18/18 SHEET NO. SP.2 PIPING LAYOUT