HomeMy WebLinkAboutSP-31 � g'-2" NOTE: THE HEATER MUST BE INTERLOCKED WITH THE FILTER PUMP 50 THAT THE HEATER CANNOT FIRE UNLESS THE FILTER FUMP IS R N Ng4G CILMITY DIWMfwrION MODEL RATNG MANUFACTURE POMR I POOL PUMP WHISPEFFLO UM-12 3 HP PENTAIR 230N60 20 A I FEATURE RUMP WHISPERfLO M-20 5 HP PENTAIR 230N60 20 A I SPA FILTRATION FUMP WHISPERfLO UM-3 3/4 HP PENTAIR 115R08-230 1 SPA THERAPY PUMP WHISPERfLO MPE-8 2 HP PENTAIR 2W V60 20 A I POOL SALINE GENERATORS INTELLICNLOR IC60 ECOLAB 120V SA GFCI I SPA SALINE GENERATORS INTELLICNLOR ICAO ECOLAB 120V BA GFCI 2 CHEMICAL CONTROLLER INTELLICHEM 922622 PENTAIR 120V BA GFCI I FV-30300P RAGE TO BE 25-130 BLUE -WHITE I FV-302000 RANGE TO BE I0-100 BLUE -WHITE 5 POOL LIGHT 601204 400 WATT EQUIVALENT NTELL15RITE 53 PENTAIR 120V 20A GFCI POOL LIGHT NIC1E 18210'TOI PENTAIR I SPA LIGHT 60I1M 300 WATT EQUIVALENT NTELL15RITE 53 PENTAIR 90V 20A GFCI SPA LIGHT NICHE 1821MOI PENTAIR 2 POOL FILTER TRI00C 3050 DIA 4.91 80. FT. TRITON II I POOL HEATER LOC14NVAR M 252 2500M BTU NATURAL LOCHINVAR MOV 20A GFCI I SPA FILTER TR60 245N DIA 3J4 SO. FT. TRITON II I SPA HEATER LOC14NVAR ERN 252 2500M BTU NATURAL LOCHINVAR MOV 20A GFCI I POOL AQUMSTAT L-6006 CIOIS SET • 95' HONEYWELL I SPA AiUASTAT L-6006 CIOIS SET • 105, HONEYWELL 4 POOL 9' SQUARE MAN DRAIN U1310311-V/PAK2 45.6 Sa N OPEN EA HAYUJARD 4 POOL HYDROSTATIC RELIEF VALVE 01011-OW PENTAIR 2 SPA O" SMARE MAN DRAN WGI032LV2PA0 83A Sa N OPEN EA HAYWARD 2 SPA HYDROSTATIC RELIEF VALVE 01011-OW PENTAIR I SPA SKIMMER SP10B2 FV (NSF) 3 POOL SKIMMER SP10B2 FV (NSF) WAYWARD 10 POOL WALL RETUR4 INLET 640035 INSIDER DIRECTIONAL FITTING 9 GPM . HAS FPS WAYWARD 5 POOL FLOOR RETURN INLET 9 GPM . 14A5 FPS PENTAIR 2 SPA WALL RETIM INLET 540042 INSIDER DIRECTIONAL FITTING 24 GPM . MB FPS PENTAIR 9 SPA THERAPY WALL R'ENRN INLET OP1434PAKA OB GPM • 113 FPS WAYWARD 2 1 AUTO FILL VALVE T40-F LETRO 3 3 SEND STAIR RAIL 3HR-5-065 5.R SMITH PRECAST COPING SLIP RESISTANT C061OQ4T OF 6 I LEAF SKIMMER NET $1691 BYTE I COMPLETE TEST KIT K-2005 TAYLOR 1 1 1/t" X 50' VACUUM HOSE 225M POOL KING 1 14" WIDE VACUUM HEAD 84-298 AlUAMAX I WALL BRJSH R 500013 F'ENTAIR RELEASED FOR CONSTRUCTION TYPE POLE Subject to compliance with all regulaBons of Slate and Local Codes City of Camel Rp °L PENTAIR F'ENTAIR M21026L 1 PENTAIR JEW-24 JIM &JOY 82154 IRON DUCK I 980500 I LADERAL DATE: 03/27/19 POOL SECTION SCALE: 1/4" = 1' 0" z POOL SECTION POOL NOTES: I. DEPTH MARKER NUMERALS ON THE EDGE OF THE DECK SHALL BE A LEAST 6" HIGH. MARKERS ON THE VERT. POOL WALL SHALL BE AT LEAST 4" HIGH. DEPTH MARKERS TO BE A COLOR CONTRASTING TO THEIR BACKGROUND. 2 ALL EQUIPMENT 4 PIPE LOCATIONS DIAGRAMMATIC ONLY. 3. POOL, MECH. 4 ELEC. CONTRACTOR COORDINATE LOCATION OF ALL EQUIP. 4. POOL CONTRACTOR SHALL SE RESPONSIBLE TO MEET ALL STATE 4 LOCAL CODES AND TO FURNISH ADDITIONAL DWG'a 4 CALCULATIONS AS MAY BE REQUIRED. 5. ALL DOORS AND GATES TO BE SELF CLOSM 4 EQUIPPED WITH SELF LATCHING HARDWARE. 6, FOOL CONTRACTOR TO PROVIDE EQUI91ENT AS PER SCHEDULE OR APPROVED EQUAL. AIR TEST ALL PIPES, AND PROTECT POOL DURING CONSTRUCTION. �- ALL ELECTRICAL WORK SHALL BE DONE BY A LICENSED ELECTRICAL CONTRACTOR 8. MAXIMUM WATER TEMPERATURE 15 84 DEGREES FOR POOL, 104 DEGREES FOR THE SPA 9 POTABLE WATER FOR THIS PROJECT WILL BE PROVIDE BY LOCAL CITY JURISDICTION. 10, POOL SHELL 4 FIXTURES SHALL BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH SECTION 680 NEC. 11. POOL, MECH. 4 ELEC. CONTRACTORS SHALL COORDINATE 4 VERIFY ALL LOCATIONS 4 CLEARANCE$ OF ALL POOL EQUIPMENT. 12. ALL PIPING MUST HAVE FLOW ARROWS. S. PROVIDE A SPARE STRAINER BASKET FOR THE RECIRCULATION RUMS. 14. POOL INSTALLER TO NSTALL POOL WALL, STAIRS, SKIMMERS, LIGHTS, WATER INLETS, DRAINS, COPING, CONCRETE AND ALL MATERIALS AND PRODUCTS ACCORDING TO THE MANUFACTURES SPECIFICATIONS AND ACCORDING TO ALL STATE AND LOCAL BUILDING CODES. 15. CLEAR DECK 814ALL BE A MINIMUM OF 4'-0" IN WIDTH FROM THE EDGE OF T14E FOOL OUT B. AN EMERGENCY PHONE AND DRINKING FOUNTAIN SHALL BE LOCATED JUST INSIDE THE MAIN ENTRANCE TO THE POOL AREA 11. EMERGENCY SHUT- OFF SWITCH FOR THE SPA CONTROLS FOR PUMPS AND SLOWER SYSTEM SHALL BE INSTALLED AT LEAST 5' AND AND NOT MORE THAN m' OF THE SPA IS. GRADE OF CONCRETE - 3000 PSI MINIMUM PER ACT 3B-110. B. REBAR - A5TM AG15-12 20. CHEMICAL CONTROLLER BY ECOLAB S A C / TlOwl 4 SCALE: 1/4" . I'-0" NOTE: I NEARBY CERTIFY THAT POOL IS DESIGNED STRUCTURAL LOADS FOR BOTH FULL AND EMPTY CONDITIONS. THESE DRAWINGS ARE DIAGRAMMATIC FOR AN UNDERSTANDING OF THE JOB. CONTRACTOR SHALL P UR415H AND INSTALL ALL PARTS 4 PIECES A FULLY OPERATIONAL AND SERVICEABLE SYSTEM MEETING ALL STATE AND LOCAL CODES. ALL METALLIC PARTS OF THE FOOL STR MSS INCLUDING THE REBAR COPING STONES, DECK METAL PARTS SHALL BE CONNECTED NTO A COMMON BONDING GRID WITH A SOLID COPPER CONDUCTOR NOT SMALLER THAN 08. 2015 INTERNATIONAL BUILDING CODE METHOD USED TO DETERMINE MIX DESIGN FIELD MIX DESCRIPTION 15 MIN BAG SHOTCRETE MIX MIX CODE 94-SHOT MIX USAGE SHOTCRETE SLUMP R44SE I - 2 INCIIES WATER/CEMENT RATIO 036 AIR CONTENT 5-8 PERCENT MATERIAL DESCRIPTION CEMENT ASTM CB0 TYPE 1 105 FLYASH ASTM C618 CLASS O 50 SLAG CEMENT ASTM C989 FINE AGGREGATE INDOT 423 SAND IBM COARSE AGGREGATE PEA GRAVEL SOO WATER POTABLE 306 MASTER BUILDERS ASTM C454 TYPE A MASTERPAVE WATER REDUCER 342 ai MASTER BIUILDES ASTM C260 AS NEEDED FOR PROPER AIR MICROAIR AIR ENTRLABMENT MATERIAL SPECIFIC GRAVITY CUBIC FEET CE1'MENT 3.15 3M FLYASW 2.15 0.91 SLAG CEMENT 225 ODO FINE AGGREGATE 263 II00 COARSE AGGREGATE 251 4.99 WATER 100 4.93 AIR IB2 YIELD 21DO 870137 SMnTC w of u I M N CIM n � O b E a Ck=rn U � I U d 0 o O � s' Q b � O e �E O U E H Y W � v =F C..> t - O im y a E i a C> C= A Q O JOB TITLE Le.l V) J Z O O Z w a Q Z C Q 0 aJ U J 0 JOB NO. 18102-07 DATE 05/22/18 REVISIONS 112/18/18 SHEET NO. SP.3 POOL LAYOUT z