HomeMy WebLinkAboutA-400-REFLECTED-CEILING-PLAN-Rev.01. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THIS RCP WITH ELECTRICAL LIGHTING PLANS, MECHANICAL SUPPLY, RETURN, ACCESS DOORS AND EXHAUST PUNS. THE CONTRACTOR SHALL REPORT ANY OMISSIONS OR INCONSISTENCY TO THE ARCHITECT. 2. SPRINKLER HEADS LOCATIONS ARE NOT SHOWN ON THIS RCP. THE CONTRACTOR SHALL INSTALL SUFFICIENT HEADS IN ALL SPACES TO PROVIDE 100%COVERAGE PER NFPA 13. CENTER ALL SPRINKLER HEADS IN CEILING TILES. 3. SEE ELECTRICAL DRAWINGS FOR THE LOCATIONS OF CEILING MOUNTED SPEAKERS, NURSE CALL, DOME LTS AND EXIT SIGNAGE , ETC. 4. ALL GB CEILINGS IN TOILET/SHOWER AREAS SHALL BE MOISTURE RESISTANT. (WASH OFF) 5. PROVIDE ACCESS DOORS IN HARD CEILINGS PER MPE. 6. LIGHTING LAYOUTS ARE APPROXIMATE. REFER TO MPE DRAWINGS FOR COORDINATED RELATIONSHIPS BETWEEN DIFFUSER GRILLES, SUPPLY VENTS AND LIGHT FIXTURES. CUBICLE CURTAINS MAY NOT TRAVERSE MPE DEVICES. 7. REFER TO ENLARGER CEILINGS PLANS FOR ADDITIONAL NOTES AND CEILING AREAS NOT INDICATED ON THIS PLAN. 0. PRIOR TO INSTALLATION OF CEILINGS VERIFY THERE WILL BE 00' CLEAR FROM BOTTOM OF TV & BRACKET TO FINISH FLOOR. 9. ALL VANITY SCONCE LIGHTS IN TOILET ROOMS SHALL BE CENTERED OVER LAVATORY RCP LEGEND ACOUSTICAL LAY -IN TILE (2- X 2' GRID SYSTEM) CENTER SPRINKLER HEADS IN 2'X 2' AREA 2X4 LAY -IN FLUORESCENT LIGHT FIXTURE (REF: ELEC.) 2X2 LAY -IN FLUURESCENT LIGHT FIXTURE (REF: ELEC.) SUPPLY AIR DIFFUSERS. REFER TO MECHANICAL RETURN AIR GRILLES- REFER TO MECHANICAL $91 oil CEILING HEIGHT DESIGNATION, Tl U.N.O. GB GYP. BOARD CEILING- TO BE PAINTED PT3, LAD, ES EXPOSED STRUCTURE (NO CEILING) ® FLUORESCENT STRIP LIGHT FIXTURE (REF: ELEC.) 0 RECESSED INCANDESCENT OR FLUORESCENT LIGHT RXTURE (REF: ELEC.) CH WALL MOUNTED LIGHT FIXTURE (REF. ELEC.) 0 SKYLIGHT �—\—� UNDER CABINET LIGHT; REF. ELECTRICAL �p SECURITY CAMERA; REF VENDOR DRAWINGS RCP NOTES BY NUMBER 01 DECORATIVE LIGHTING FIXTURE REF. MEPDRAWINGS O2 CUBICLE CURTAIN TRACK 03 ACCESS LADDER 04 COORDINATE CEILING HEIGHT WITH FINAL EQUIPMENT 05 OFCI TV BRACKET(TYPICAL) COORDINATE BLOCKING& MEP.; REF. TO ELECTRICAL FOR MOUNTING HEIGHTS 06 COORDINATE EQUIPMENT AND SUPPORTS WITH SPRINKLER LOCATIONS; CONSULT ARCHITECT WITH ANY CONFLICTS 07 PROVIDE HOLD DOWN CLI PS IN HATCHED AREA OS FRY REGLET,"V'REVEAL 314" OB SHOWER CURTAIN DATE: 06/07/19 H W Z OC z g E W o m Z <Lu Owl— e d J >wU - 009 Z � m W Q ¢ O w i iffi z n g E m n / Z 0 W 0 m � Seals ISSUED FOR BID & PERMIT C O O U M C O QJ cc CCD Z C J Lu w CD U i c6 U � a) EL j Qi �j � i ZD � cm J 0 NJ N 2 � (D N = 1 W r Na Rel Oat Z J Q L LI T G> a+ Z 91f Protect Number: 3018082 Date 02/26/2019 Sheet Thle and Number: A-400 REFLECTED CEILING PLAN