HomeMy WebLinkAboutA-400-REFLECTED-CEILING-PLAN-Rev.01. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THIS RCP WITH ELECTRICAL
LIGHTING PLANS, MECHANICAL SUPPLY, RETURN, ACCESS DOORS AND EXHAUST PUNS. THE
CONTRACTOR SHALL REPORT ANY OMISSIONS OR INCONSISTENCY TO THE ARCHITECT.
2. SPRINKLER HEADS LOCATIONS ARE NOT SHOWN ON THIS RCP. THE CONTRACTOR SHALL
INSTALL SUFFICIENT HEADS IN ALL SPACES TO PROVIDE 100%COVERAGE PER NFPA 13. CENTER
ALL SPRINKLER HEADS IN CEILING TILES.
3. SEE ELECTRICAL DRAWINGS FOR THE LOCATIONS OF CEILING MOUNTED SPEAKERS, NURSE
CALL, DOME LTS AND EXIT SIGNAGE , ETC.
4. ALL GB CEILINGS IN TOILET/SHOWER AREAS SHALL BE MOISTURE RESISTANT. (WASH OFF)
5. PROVIDE ACCESS DOORS IN HARD CEILINGS PER MPE.
6. LIGHTING LAYOUTS ARE APPROXIMATE. REFER TO MPE DRAWINGS FOR COORDINATED
RELATIONSHIPS BETWEEN DIFFUSER GRILLES, SUPPLY VENTS AND LIGHT FIXTURES. CUBICLE
CURTAINS MAY NOT TRAVERSE MPE DEVICES.
7. REFER TO ENLARGER CEILINGS PLANS FOR ADDITIONAL NOTES AND CEILING AREAS NOT
INDICATED ON THIS PLAN.
0. PRIOR TO INSTALLATION OF CEILINGS VERIFY THERE WILL BE 00' CLEAR FROM BOTTOM OF TV
& BRACKET TO FINISH FLOOR.
9. ALL VANITY SCONCE LIGHTS IN TOILET ROOMS SHALL BE CENTERED OVER LAVATORY
RCP LEGEND
ACOUSTICAL LAY -IN TILE (2- X 2' GRID SYSTEM)
CENTER SPRINKLER HEADS IN 2'X 2' AREA
2X4 LAY -IN FLUORESCENT LIGHT FIXTURE
(REF: ELEC.)
2X2 LAY -IN FLUURESCENT LIGHT FIXTURE
(REF: ELEC.)
SUPPLY AIR DIFFUSERS. REFER TO MECHANICAL
RETURN AIR GRILLES- REFER TO MECHANICAL
$91 oil
CEILING HEIGHT DESIGNATION, Tl U.N.O.
GB GYP. BOARD CEILING- TO BE PAINTED PT3, LAD,
ES EXPOSED STRUCTURE (NO CEILING)
® FLUORESCENT STRIP LIGHT FIXTURE
(REF: ELEC.)
0 RECESSED INCANDESCENT OR FLUORESCENT LIGHT RXTURE
(REF: ELEC.)
CH WALL MOUNTED LIGHT FIXTURE
(REF. ELEC.)
0 SKYLIGHT
�—\—� UNDER CABINET LIGHT; REF. ELECTRICAL
�p SECURITY CAMERA; REF VENDOR DRAWINGS
RCP NOTES BY NUMBER
01 DECORATIVE LIGHTING FIXTURE REF. MEPDRAWINGS
O2 CUBICLE CURTAIN TRACK
03 ACCESS LADDER
04 COORDINATE CEILING HEIGHT WITH FINAL EQUIPMENT
05 OFCI TV BRACKET(TYPICAL) COORDINATE BLOCKING& MEP.; REF. TO ELECTRICAL
FOR MOUNTING HEIGHTS
06 COORDINATE EQUIPMENT AND SUPPORTS WITH SPRINKLER LOCATIONS;
CONSULT ARCHITECT WITH ANY CONFLICTS
07 PROVIDE HOLD DOWN CLI PS IN HATCHED AREA
OS FRY REGLET,"V'REVEAL 314"
OB SHOWER CURTAIN
DATE: 06/07/19
H W
Z OC
z
g
E
W
o
m
Z <Lu
Owl—
e
d
J
>wU
-
009
Z �
m
W Q
¢
O
w
i
iffi
z
n
g
E
m
n
/
Z
0
W
0
m
�
Seals
ISSUED FOR BID &
PERMIT
C
O
O
U
M
C
O
QJ
cc
CCD
Z
C
J
Lu
w
CD
U
i
c6
U
�
a)
EL
j
Qi
�j
�
i
ZD
�
cm
J
0
NJ
N
2
�
(D
N
=
1
W
r
Na
Rel
Oat
Z
J
Q
L LI
T
G>
a+
Z
91f
Protect Number: 3018082
Date 02/26/2019
Sheet Thle and Number:
A-400
REFLECTED CEILING PLAN