HomeMy WebLinkAboutE-001-SCHEDULES-AND-DETAILS---ELECTRICAL-Rev.0RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City 0f Camel DATE: 06/07/19 POWER SYMBOL DESCRIPTION MOUNTING SIMPLEX RECEPTACLE. 18"AFF QP DUPLE%RECEPTACLE. 18"AFF DUPLEX TAMPER RESISTANT RECEPTACLE. 18"AFF A DUPLEX RECEPTACLE MOUNTED 8"ABOVE COUNTER U.N.O. 8"ACT GFI IP GFI RECEPTACLE. 18"AFF GFI Q GFI RECEPTACLE MOUNTED 8" ABOVE COUNTERISINK, U.N.O. g'ACT GR R QY GFI RECEPTACLE.'R INDICATES REMOTE DEAD FRONT -NOTE 7. 18"AFF GFI,WP QY GFI RECEPTACLE.'WP'INDICATES WEATHERPROOF COVER. 18"AFF QTV DUPLEX RECEPTACLE MOUNTED AT 96" ABOVE FINISHED FLOOR, U.N.O.- NOTE NOTE VUSB DUPLEX RECEPTACLENSB 18"AFF QUSB UPLE% RECEPTACLENSB MOUNTED HORIZONTALLY ABOVE COUNTER, U.N.O. $'ACT 4P DUPLEX RECEPTACLE, ON EMERGENCY POWER CIRCUIT. NOTE: TICK MARKS SHOWN ON RECEPTACLE SYMBOL INDICATES CONNECTION TO THE EMERGENCY CIRCUIT (RED DEVICE). TYPICAL FOR ANY SYMBOL. 18"AFF W QUADRUPLE%RECEPTACLE. 18"AFF SPECIAL PURPOSE RECEPTACLE. 18"AFF ® FLOOR MOUNTED DUPLEX RECEPTACLE. FLOOR 0 POKE THROUGH DEVICE. FLOOR ® CEILING MOUNTED DUPLEX RECEPTACLE. CEILING ® PLUGMOLD, NEMA 5-MR RECEPTACLE 24" O.C. UNO 42' AFF MOTOR. AS REQ'D aQ JUNCTION BOX CEILING MOUNTED. CEILING Q JUNCTION BOX WALL MOUNTED. AS REQ'D TT GROUND BAR. AS REQ'D LIGHTING SYMBOL DESCRIPTION MOUNTING ° LIGHT FIXTURE- OPEN CIRCLE INDICATES NORMAL POWER -TYPICAL FOR ALL FIXTURES. NOTE: TEXT DENOTES ASSOCIATED 'FIXTURE TYPE'(A2t'SWITCH1EG'(a), TYPICAL FOR ANY LIGHT FIXTURE. CEILING A2,a ®LIGHT FIXTURE- LIFE SAFETY POWER INDICATED BY CROSS HATCH. TYPICAL FOR ALL FIXTURES. CEILING LIGHT FIXTURE- CRITICAL POWER INDICATED BY FILLED CIRCLE. TYPICAL FOR ALL FIXTURES. CEILING ° DUAL CIRCUIT LIGHT FIXTURE- CRITICAL DRIVER WILL CONTROL OUTER UGHT(S) AND NORMAL DRIVER WILL CONTROL INNER LIGHT(S) CEILING LINEAR LED LIGHT FIXTURE AS REO'D o STRIP LIGHT FIXTURE. AS REO'D WALL MOUNTED LIGHT FIXTURE. AS REO'D 0 DOWNLIGHT FIXTURE. CEILING WALL WASHER FIXTURE. CEILING Q WALL MOUNTED LIGHT FIXTURE. AS REO'D ® EXIT LIGHT FIXTURE WITH DIRECTION CHEVRONS AS SHOWN. SHADED QUADRANT($) INDICATE FACE($) OF FIXTURE. CEILING EAT LIGHT FIXTURE, WALL MOUNTED. AS REO'D EMERGENCY DUAL HEAD LIGHTING FIXTURE WITH BATTERY PACK. AS REQ'D GENERAL NOTES A. INSTALL LIGHTING CONTROLLERS 48" ABOVE FINISHED FLOOR TO CENTER OF DEVICE, UNLESS NOTES OTHERWISE. B. INSTALL RECEPTACLES 18"ABOVE FINISHED FLOOR TO CENTER OF DEVICES, UNLESS NOTES OTHERWISE. C. INSTALL RECEPTACLES ABOVE COUNTER AT 8" ABOVE COUNTER TO CENTER OF DEVICE, UNLESS NOTES OTHERWISE. D. RECEPTACLES WITHIN FOF SINK SHALL BE GFI TYPE. RECEPTACLES SERVING VENDING MACHINES, WITHIN KITCHENS AND EXTERIOR LOCATIONS SHALL BE GFI TYPE. E. INSTALL RECEPTACLES WITH GROUND PIN MOUNTED UP. F. BOND TOGETHER EQUIPMENT GROUND BARS OF NORMAL AND ESSENTIAL ELECTRICAL SYSTEM PANELBOARDS SERVING THE SAME PATENT VICINITY WITH 910 AWG INSLLATED CONTINUOUS COPPER CONDUCTOR. G. EQUIPMENT SHALL BE RATED SUITABLE FOR INSTALLED ENVIRONMENT. H. INSTALL BOXES WITHIN FIRE RATED WALLS AND ASSEMBLIES TO MAINTAIN FIRE RATING. I. PROVIDE TYPE M17EN DIRECTORIES FOR NEW AND EXISTING PANELS AFFECTED BY T IS PROJECT. REVISE ROOM NAMESAND NUMBERS CONTAINED ON THE CONSTRUCTION DOCUMENT PANEL DIRECTORIES TO MATCH ACTUAL ROOM NAMES AND NUMBERS ELECTRICAL SYMBOL LEGEND FIRE ALARM SYMBOL DESCRIPTION ® FIRE ALARM CONTROL PANEL. COORDINATE EXACT LOCATION. ® FIRE ALARM ANNUNCIATOR PANEL. COORDINATE EXACT LOCATION. IREaD 0 MANUAL PULL STATION -NOTE 4. LtCOMBINATION AUDIBLENISUAL NOTIFICATION DEVICE -NOTE 3. IJ VISUAL NOTIFICATION DEVICE -NOTE 3. ft; I CEILING MOUNTED AUDIBLEMSUAL NOTIFICATION DEVICE. CEILING Ctc CEILING MOUNTED VISUAL NOTIFICATION DEVICE. CEILING ® FLOW SWITCH. AS REO'D ® TAMPERSWITCH. CEILING SO SMOKE DETECTOR. CEILING © CARBON MONOXIDE DETECTOR. AS REO'D OH HEAT DETECTOR. ASREQ'D O DUCT SMOKE DETECTOR. ASREQ'D 9 FIRE FIGHTERS JACK 48"AFF DISCONNECTING MEANS/CONTROLS SYMBOL DESCRIPTION MOUNTING $ SINGLE POLE SWITCH) LOW VOLTAGE CONTROLLER AS REQUIRED. 48"AFF $a LOW VOLTAGE CONTROLLER. LETTER DENOTES CONTROL CIRCUITSWITCH LEG, TYPICAL FORALL CONTROLLERS. 48"PFF $3 LOWVOLTAGE CONTROLLER(OPERATING AS A3-WAY SWITCH). 48"AFF $4 LOWVOLTAGE CONTROLLER(OPERATING AS A 4-WAY SWITCH). 48"AFF $D DIMMER SWITCWCONTROL. 48"AFF $WP SINGLE POLE SWITCH WITH WEATHERPROOF COVER 48"AFF $K SINGLE POLE KEY SWITCH. 48"AFF $T SINGLE POLE TIMER SWITCH. 48"AFF, U.N.O. $M MOTOR RATED SWITCH. 48"AFF $D' WALL MOUNTED DUALTECHNOLOGY OCCUPANCY SENSOWSWITCH. 48"AFF $W' WALL MOUNTED DUAL TECHNOLOGYVACANCY SENSOWSWITCH. 48"AFF ®a CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCYSENSOR WITH SWITCH LEG IDENTIFIER. CEILING DaCEILING MOUNTED DUAL TECHNOLOGYVACANCY SENSOR WITH SWITCH LEG IDENTIFIER. CEILING ® PHOTOCELL. AS REQ'D GPD EMERGENCY POWER OFF BUTTON. 48"AFF Ell MAGNETIC DOOR HOLD OPEN. AS REO'D PP PUSH PLATE. 48"AFF ® MOTION DETECTOR TO OPERATE MOTORIZED DOOR. CEILING © TIME CLOCK ASREQ'D 3L1+F0 WHEN ADJACENTTO DISCONNECTING MEANS DENOTES'SWITCH SIZE'TFUSE SIZE'TNUMBER OF POLES.'NF INDICATES NON -FUSED. DISCONNECT SWITCH. AS RED D I� FUSIBLE DISCONNECT SWITCH. AS REO'D STARTEROISCONNECT SWITCH. AS REO'D LIGHTING AND APPLIANCE PANEUBOARD. AS REO'D © ENCLOSED CIRCUIT BREAKER. AS REO'D ABBREVIATIONS ACT ABOVE COUNTERTOP AFF ABOVE FINISHED FLOOR C CONDUIT CB CIRCUIT BREAKER E INDICATED DEVICE ON EMERGENCY CIRCUIT EX EXISTING G GROUND GFI GROUND FAULT CIRCUIT INTERRUPTER GFIIR GROUND FAULT CIRCUIT INTERRUPTER WITH REMOTE DEAD FRONT IS ISOLATED GROUND OC ON CENTER PP POWER POLE RCPT(S) RECEPTACLE(S) ST SHUNTTRIP UNO UNLESS NOTED OTHERWISE WP WEATHERPROOF %FMR TRANSFORMER TELECOMMUNICATIONS DESCRIPTION TELEPHONE OUTLET -NOTE 1. WALL MOUNTED TELEPHONE OUTLET -NOTE I AND NOTE 5. SYMBOL MOUNTING ♦ 18"AFF ♦ 4T AFF AS REO'D 2 v DATA OUTLET -NOTE 1. NOTE: SUBSCRIPT INDICATES NUMBER OF DROPS (IE.2 INDICATES (2) TWO DATA DROPS). NO SUBSCRIPT INDICATES SINGLE DROP. TYPICAL FOR ANY TELECOMMUNICATION DEVICES. 'ACT SUBSCRIPT INDICATES E' O.C. ABOVE COUNTER TOP. ® FLOOR MOUNTED TELEPHONE OUTLET. FLOOR M FLOOR MOUNTED DATA OUTLET. FLOOR ® FLOOR MOUNTED COMBINATION TELEPHONEIDATA OUTLET. FLOOR CEIUNG MOUNTED DATA OUTLET. CEILING ® CEIUNG MOUNTED COMBINATION TELEPHONEJDATA OUTLET. CEILING m TELEVISION SIGNAL OUTLET NOTE 1. MOUNTED AT 96"ABOVE FINISHED FLOOR. UNLESS NOTED OTHERWISE -NOTE 6. 96"AFF PAGING SPEAKERS. CEILING Q SINGLE FACE CLOCK OUTLET -NOTE 1. MAFF POWER OVER ETHERNET- NO BACK BOX M AFF TELEPHONE PLYWOOD BACKBOARD, 314"THICK 7 HIGH - NOTE 2 AS REO'D AP WIRELESS ACCESS POINT - NOTE 1. AS REO'D Q ANTENNA. CEILING NURSE CALL SYMBOL DESCRIPTION MOUNTING FNC-PI NURSE CALL CONTROL PANEL- TYPICAL FOR ALL FIXTURES AS REO'D IDS NURSE CALL CONTROLSTATION- TYPICAL FOR ALL FIXTURES AS REO'D NQ NURSE CALL PATIENT STATION. NOTE 1, UNO AS REQ'D B NQ NURSE CPi1 STAFF STATION. NOTE 1, 11N0 48' AFF ID NURSE CALL COMBINATION DUTY/STAFF STATION. NOTE 1, UNO 48'' AFF OD NURSE CALL PATIENT STATIOWCODE BLUE, NOTE 1, UNO AS REO'D NQ @ NURSE CALL EMERGENCY PULL STATION. NOTE 1, LINO AS REQ'D a CEILING MOUNTED NURSE CALL CORRIDOR DOME LIGHT ASREQ'D SECURITY SYMBOL DESCRIPTION MOUNTING Da CAMERA -NOTE 1. A$REQD HE KEYPAD ASREQD OR CARD READER. PROVIDE DOOR POSITION SWITCH CONTACT(S) FOR ASSOCIATED DOORS). DOUBLE POLE, DOUBLE THROW 481AFF I]B PANICBUTTON. AS REDID DOOR RELEASE, AS REQ'D [I] INTERCOMMUNICATION DEVICE. AS REQ'D ELECTRICAL SYMBOL LEGEND NOTES I PROVIDE BACKBi MUD RING,1"CONDUITWITH PULL STRINGTO 6ABOVE ACCESSIBLE CEILING. COORDINATE SIZE OF BACK BOX WITH ASSOCIATED EQUIPMENT REQUIREMENTS. 2. BOTTOM OF PLYWOOD BOARD 12"AFF UNO. AUDIOMSUAL DEVICE: 80' AFF OR T BELOW CEILING WHICHEVER IS LOWER PER 3' TASIADA REQUIREMENTS. DIMENSION IS TO BOTTOM OF VISUAL DEVICE, 4. MANUAL PULL STATION: 49'AFF TO CENTER OF DEVICE. 5 PROVIDE T CLEARANCE ON EACH SIDE OF PHONE. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT REQUIREMENTS. B COORDINATE EXACT LOCATION WITH TV BRACKET LOCATION PRIOR TO CONSTRUCTION. DEVICE TO BE LOCATED DIRECTLY BEHIND THE TELEVISION AS TO AVOID BRACKET. PROVIDE REMOTE"DEAD FRONT' GFI DEVICE AT 8" ACT AT NEAREST COUNTER 7. LOCATION. DEVICE SHALL BE PROVIDED FOR REFRIGERATOR AND UNDERCOUNTER REGRIGERATOR RECEPTACE(S) WITHIN B' OF CENTER OF SINK TYPICAL. SW ASSOCIATES caneul4rg Engineers 17W Pacific Ave Sore 2100 Dallas, TX 75MI Tel 214,30,0211 x SWAengireers com PRWECT#18209 L7 H W can o z 5d LU 2 1— as Owl § V z A� J Z O � a W LQ 0 o O r W Z m 4 o E m N m R STATE OF Seals V ISSUED FOR BID & PERMIT E O 0 Project Norther : 3018082 Date 02/262019 Sheet Title and Nionber: E-001 SCHEDULES AND DETAILS -