Loading...
HomeMy WebLinkAboutE-601-ELECTRICAL-ONE-LINE-DIAGRAM-Rev.0SW ASSOCIATES cn Coneulerq Engineers H W _ o Z E 17W Pacific Ave Sufte iT W Dallas, 75MI Tel: 214.347.0211 wr,.,.swr relree,: coin JU - PROJECT#18203 § I OWE max= z ]�U m Z Q a - W WQ 0 O r o w x Z ryg m a E o w` m h o m m uGnuPl'a'�%..�� a:a�1N �O'•,p151fq�OTy�% YYYY i ' `- (Np. PE 10403225E _`_ ONAI EwNa�y� 'is F`r /Q�� KEYED NOTES:O �a15 U 02/26/19 NOTE : REFERENCE NUMBER INSIDE HE%AGON 7. TRYSTAR DOCKING STATION WITH KIRK KEY WTERLOCK. 40OA480V-3PH. NEW SIR ACCESS TO CAMLOCK PANELMOUNTS IS PREVENTED UNTIL ISSUED FOR BID & MAIN GENERATOR CIRCUIT BREAKER IS OPENED. PERMIT SEQUENCE OF OPERATIONS: - KIRK KEY IS HELD CAPTIVE AT GENERATOR MAIN BREAKER. -TURN OFF GENERATOR BREAKER AND REMOVE KIRK KEY. - INSERT KIRK KEY TO OPEN CAMLOCK DOOR TO ALLOW CONNECTION OF TEMPORARY GENERATOR CABLES. KEY IS HELD CAPTIVE UNTIL ALL TEMPORARY CABLES REMOVE D AND DOOR LOCKED PREVENTING POSSIBILITY OF PARALLEING POWER. - INSERT KIRK KEY TO CLOSE MAIN GENERATOR BREAKER TO EMERGENCY GENERATOR RESUME NORMAL OPERATION. 3PH, 480VI277V15OKW t GND O Q NEW PAD MOUNTED _ UTILITY TRANSFORMER #2 GND. U M C O CID U1 � i z H ELECTRICAL METER TEMPORARY BY POWER COMPANY 30013 J GENERATOR K LSI IW W BV OWNER ^� 06 SERVICE DISCONNECT-NEI I Q #310 GND. G 8001 BREAKER I (L) U 42 DDDAIC 1 O U C d (2) SETS EACH OF 14#600KCM, 3-in"C) t (2) SPARE 3-012"C U J MAIN DISIF 480I N 42,OOO,4W BOOA ML0, 42,000AIC 4k350KCM, 7#4G, 3"C t (2) SPARE 3"C - W NSS 260KA DISTRIBUTION WIREWAV ^I a � > 2 22513 22513 11013 80/3 7293 22513 2293 -, P.S. P.S. S- P S. 225f3 LSI 225f3 LSI �- LSI LSI LSI LSI •"' 225A �-' 225A -` 225A ENCLOSED CB ENCLOSED CB lip 22,000AIC 22,000AIC = V No Revision Date 8013 12513 SHUNTTRIP SHUNTTRIP PNL PINE ATS-1 ATS-2 'HB' 'HA' 2251 225A4P 225A 225A CU-1 30,000AIC X4RAV CTJ=H 30,000AIC MILO MLO TLB TLX 45KVA 45KVA PNL LI FE SAFETY PNL EQUIPMENT 'ELSH' BRANCH 'EQH BRANCH 225A 225A PNL PNL ECL' TELSL' 'TECL' +j 'LB 'LA' 45 KVA 15 KVA 15 KVA a� 150A 150A M.C.B. M.C.B. (84 CKT- (84CKT- Z SINGLE SINGLE iiiiiiiim SECTION) SECTION) PNL PNL PNL 'ECL' 'ELSE' 'EQL' 150A 60A 60A 4 MCB MCB MCB Project Number 301801 Date 02/26/2019 Shoot Tile and Nlmber: %1 ELECTRICAL RISER DIAGRAM RELEASED FOR CONSTRUCTION I SCALE: N.T.S. Subject to compliance with all regulations of State and local Codes E-601 City d Camel 13 ELECTRICAL ONE -LINE DIAGRAM BRANCH AND FEEDER CIRCUIT SCHEDULE -COPPER AMPS CONDUCTORS EMT PVC 40 CONDUCTORS EMT PVCdp 15 3p12 CU, p12 CUG 3l4"C 3l4"C 4p12 CU, p12 CUG 3l4"C 3'4"C 2p 3p12 CU, p12 CUG 3l4"C 3l4"C 4#72 CU, p72 CUG 3l4"C 3'4"C 25 3p10 CU, p10 CUG 3l4"C 3I6"C dplpcu,pmcuc 3l4"C 3'4"C 3p 3pip CU, pip CUG 3l4"C 3I6"C 4pID CU, pip CUG 3l4"C 35 3p8 CU, p1p CUG 3Id'C 3I4'C 4iB CU, p1p CUG 3Id'C by 3p8 CU, p1p CUG 3Id'C 3l4'C 4iB CU, p1p CUG 3Id'C 45 3p6 CU, pip CUG 3Id"C 3Id"C 4#6CU, pip CUG 1"C 03WC 5p 3p6 CU, pip CUG 3Id"C 3Id"C 4#6CU, pip CUG 1"C fio 3p4CU, p1pCUG 1"C 1^C 4p4CU, p1p CUG 11I4'C ]p 3p4CU,p8 CUG 1"C 1'CCU,p8 CUG 1114'C Bp 3p3 CU,pe CUG 1114"C 11I4'C 4p3 CU,pe CUG 1114"C 11I4"C 90 3p2 CU,pe CUG 1114"C 11I4^C 4in CU,pB CUG 11I4"C 11I4"C 100 3p1 CU, p8 CUG 1 1I4'C 1 1?C 4#I CU, p8 CUG 1 1IrC 1 1?C 110 3p1 CU,p6 CUG 1114'C 11ITC 4#I CU,p6 CUG 11IrC 11?C 125 3p1 CU,p6 CUG 1114'C 11ITC 4#I CU,p6 CUG 11IrC 11?C 150 3pvo cu, pscuG 11n"c lvrc 4p110 cu,l�cuG z"c z"c 225 3l@Ip CU, pb CUG 212'C 21ITC 4i@Ip CU, pb CUG 212'C 212'C NOTES: 1. COPPER CONDUCTOR AMPACITY S2ES BASED ON 2008 NEC TABLE 370.75(B)(1fi). CONDUCTORS LESS THAN 7 70 AMPS UTILIZE fi0°O CONDUCTORS GREATER THAN 7 70 AMPS UTILIZE 75°C. 2. GROUND CONDUCTOR SIZES ARE BASED ON 2008 NEC TABLE 250.722. 3. CONDUIT SIZES ARE BASED ON 2008 NEC TABLES C.7 (ENT) AND C.70 (PVC). d. CONDUIT SIZES FOR OTHER INSULATION CHARACTERISTIC, USE THE 2p08 NEC, PNNEXCTABIE. DATE: 06/07/19 TRANSFORMER SCHEDULE -COPPER PRIMARY SECONDARY KVA GROUNDING NP CONDUCTORSICONDUR NP CONDUCTORSICONDUIT ELECTRODE 15 2513 3pf0, p70G, 314"C 6013 4p4,p8G, 7414"C ipBG 3p 5013 3p6, p10G, 314"C 10013 4p1,p6G, 1-il2"C ip6G 45 7013 Si pBG, 1"C 15013 dp110, p6G, 2"C ip6G ]5 72513 3p1,p6G, 1-114"C 2259 4p410, p2G,2-0IrC ip2G 112.5 17513 3p2N, p6G, 2"C 40p13 dp600KCM, p1lOG, 3-1 ITC ip1lpG 15p 225'3 3pMU, p4G, 2"C 50p13 2SETS OF 4p250KCM, p1lOG, 2-1 ITC ip1lpG OCA- OVERCURRENT PROTECTION rYP-PMPSIPOLES NOTES: 7. COPPER CONDUCTOR AMPACITY SIZES BASED ON 2008 NEC TABLE 370.75(B)(76). CONDUCTORS LESS THAN 770 AMPS UTILIZE fi0°C. CONDUCTORS GREATERTHAN 7 70 AMPS UTILIZE 75°C. 2. CONDUIT SIZES ARE BASED ON 2008 NEC TABLE O7 (ENT). 3. CONDUIT SIZES FOR OTHER INSULATION CHARACTERISTIC, USE THE 2008 NEC, ANNEXCTABLE.