HomeMy WebLinkAboutM-801-DETAILS---MECHANICAL-Rev.0OPEN NIPPLE ABOVE TOP OF DRAIN PAN. C.O. @ EVERY CHANGE IN DIRECTION GREATER THAN 45 AND AT MAX. OF 25 FEET INTERVALS. WEATHERPROOF ALUMINUM HOUSING FAN TYPE AS SCHEDULED BIRDSCREEN SECURE TO CURB WITH STAINLESS STEEL SCREWS o O.C. ALL SIDES. ROOF INSULATION & MEMBRANE ROOF DECK REFER TO FLOOR PLANS FOR SIZES DRAIN LINE SHALL BEAT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN. PITCH DOWN TOWARD DRAIN, MIN. 118" PER ft. T.S.P. OF FAN PLUS 1" WATER FLOOR DRAIN CONDENSATE DRAIN TRAP DETAIL �J SCALE: N.T.S. �1 EXHAUST FAN ON ROOF DETAIL SCALE: N.T.S. .016 ALUM. INSULATION PROTECTIVE COVER ON EXPOSED PIPING 12' LONG, 16 GA CURVED GALV. STEEL SUPPORT FASTENED TO 40r4- REDWOOD RUNNER ON RASED SUPPORT CURB. (SPACED @ "' CENTERS) SEE SPECS FOR SUPPORTS PIPE SUPPORT DETAIL RELEASED FOR CONSTRUCTION 9.' SCALE: N.T.S. Subject to compliance with all regulations of State and Local Codes City of �Caromed �/\�� VTGtiUDa141WMC_ DATE: 06/07/19 C.0 OPPOSED BLADE DAMPER WALL CONSTRUCTION INI:E1111J411 CONDENSATE DRAIN TRAP WITH SUFFICIENT TRAP SEAL TO OFFSET SUPPLY — PRESSURE ATDRAIN PAN. REGISTER, RENRN SIMIIAR BIRDSCREEN NI_(1@DP1IPG111R3 PREFAB ROOF CURB WITH BUILT-IN CANT FLASH & COUNTERFLASH WEATHERTIGHT 16' ABOVE ROOF FINISHED SURFACE. COORDINATE CURB HEIGHT WITH INSULATION THICKNESS TO ACHIEVE THIS DIMENSION ROOF CURB INSULATION DAMPER TYPE AS SCHEDULED III PIPING /-SHT.MTLFLASHING 4Ne REDWOOD RUNNER x 4 NOIE'. WHERE REGISTER MOUNTED EXPOSED ON DUCT. TAP TO BE SIZE OF FUNGE ON REGISTER TURN SHEET METAL DOWNAND FASTEN FLANGE WITH SCREWS. SJE �ETPL ETMSMATION IIII REGISTER L CLINCH LOCCOOM STOP INSULATION AMID TURN SHEET METAL BACK TO REG. NECK SIDEWALL REGISTER DETAIL �J SCALE: N.T.S. CONICAL TAP WITH INTEGRAL MANUAL VOLUME DAMPER AND LOCKING HANDLE. PROVIDE 2" INSULATION STAND OFF EQUAL TO FLEXMASTER CB-D-B112. FOR BRANCHES TO HERA FILTERS WITH INTEGRAL DAMPERS, OMIT DAMPER AT BRANCH TAKE OFF. TURNING VANES BOLTED TO SIDE OF TAP. V THICK DUCTLINER. SUPPLY DUCT SEE PUN. MINIMUM DEPTH 2"LAR3ER THAN DUCT TAP. SUPPLY DUCT RIGID ROUND DUCT J DIFFUSER SW ASSOCIATES Consulting Engineers 1100 Pal Ave SUW21M Dallas, TX 75ZI Tel. 214.391.0211 ffiwwxSWOenginiwnicorn PROJECT#18209 FLEX DUCT 6'MAX. EQUAL TO FLE%MASTER TYPE SM. INSULATE TOP OF DIFFUSER. TYPICAL OF ALL DIFFUSERS. CEILINGTILE �1 DIFFUSER CONNECTION DETAIL �J SCALE: N.T.S. A MANUAL VOLUME L=1.5X DAMPER EXHAUST AIR X X::DUCT SEE PLAN Y X.v B AB=XIY SPUTTER DAMPER fry MANUAL VOLUME DAMPER MTH LOCKING HANDLE AND F INSULATION STANDOFF. =QUAL TO RUSKIN MD35 FLEX DUCT SHALL HAVE SMACNA SEAL RATED FOR - 2" W.G. MAXIMUM 6 LENGTH SHEET METAL PLENUM FULL SIZE OF GRILLE NECK S, MINIMUM OF 3" TALL, INSULATE TOP OF PLENUM MANUALVOLUME DAMPER 45 DEG. LI C 45 DEG. ! 1 MAIN DUCT MUN DUCT EXHAUST GRILLES I T-BAR BY OTHERS TYPICAL CONICAL TAP TYPICALTAP �1 RETURNWLIST AIR GRILLE DUCT CONNECTION SCALE: N.T.S. LOW PRESSURE DUCT DETAIL �J SCALE: N.T.S. DUCT 2�114"ANGLE IRON WITH GALVANEAL FINISH 6'-0"SPACING 18 DUCTWORK SUPPORT DETAIL \J SCALE: N.T.S. 5116.1EK ON 12" Cl TYPICAL COORDINAT SUPPORTHI NTH WALK I LaVT.T1 E DUCTSII COIL TRANSITION REQUIRED SUPPLY AIR DUCT, SEE PLANS FOR SIZE. VAV BOX PLAN VIEW T 16 GAGE SHEETMETAL STRAPS — SECURE TOSTRUCTURE, MIN. OF 4. VAV I I I I I BOX RECOMMENDATIONS LAY -IN CEILING PRIMARY AIR DUCT, SEE PLANS FOR SIZE PRIMARY AIR DUCT SUPPLY AIR DUCT. ELECTRICAL COIL SEE PLANS FOR SIZE ELEVATION VAV WITH ELECTRIC REHEAT DETAIL �J SCALE: N.T.S. Cn LLI E ¢z W =H su ~C� p 15 J USE a LULU Cc"U i2 ED Z0� g m BUB 2 m Co Co2 mO ,e m PE 10403 STATE OF Gadla �� ISSUED FOR BID & PERMIT C O O M U CY) C O CL) (9 Z CL) J W Iy 06 cc G.3 U (T5 U � QD C 11 � J QJ W J _ LJLJ QJ N �_ Q 2 + QD LO LO Lr) � = r No Revision Date Project Number. 3018082 Date 02/26/2019 Shect T"I and Number. M-801 DETAILS - MECHANICAL