HomeMy WebLinkAboutM-802-DETAILS---MECHANICAL-Rev.0SW ASSOCIATES cn Consulting Engineers W G o Z e QJ 1700 Pam Ave x LLISUW @ Dallas?TX 75ZI =� O d Tel. 214.391.0211 �.SWAengineen.corn d ZJw PROJECT#IW09 Owl 4 AIR COOLED C= WALL —Tn 1" MINIMUM OPENING OVERLAP CONDENSER UNIT NCO c j ON ALL SIDES OF DAMPER g on FAN DISCHARGE TRANSITION AS REQUIRED WOW ¢ a NOTE: DUCT FUSIBLE R00 1. PROVIDE ACCESS DOOR FORALL FIRESMOKE DAMPERS. SIZE& INSTALL REFRIGERANT LINES PER VAV TERMINAL UNIT z 'o 2. FOR DUCTS 12112 AND SMALLER REQUIRING A FIRESMOKE CONDENSER UNIT MANUFACTURER'S r g DAMPER, TRANSITION TO A DUCT A TOTAL OF 2"LARGER RECOMMENDATIONS Ell ON EACH SIDE PRIOR TO DAMPER CONNECTION. E TRANSITION BACK TO ORIGINAL DUCT SIZE AFTER EXITING — Ca E DAMPERFRAME DAMPER. LARGER SIZE DUCT SHALL BE USED TO SIZE z w REQUIRED DAMPER. PRIMARY AIR DUCT SIZED TO MATCH OPERATORIACTUATOR EQUIPMENT SUPPORTS LOW PRESSURE SUPPLY AIR DUCT, PLAN VIEW UNIT CONNECTION. PROVDETWOTO� PATE CO. STYLE "ES-1 A" '- SEE PLANS FOR SIZE FIVE DUCT DIAMETERS OF STRAIGHT m AUXILIARY OPERATING OPERATION: OR APPROVED EQUAL DUCT WITHOUT ELBOWS IMMEDIATELY JACKSHAFT A FIRE DAMPER MODE: HIGH TEMPERATURE MELTS FUSIBLE - UPSTREAM OF THE UNIT LINK. CLOSING FIRE DAMPER. 1111ppnnJpJe11 o" N G. P/ ��i� a ey. RUN ROOFING MEMBRANE B. SMOKE DAMPER MODE: SMOKE DETECTOR UPON SENSING UP TO FLASHING �•'p15TEy'.•., .`�•'fr. Epy �, HEATISMOKE ACTUATES DAMPER MOTOR TO CLOSE CALKING MATERIAL PIPE CURB ASSEMBLY DAMPER. PATE CO. STYLE "PCA-1" MOPE 10403225: = c C. PROVIDE INTEGRAL NO FLOWSENSOR WITH REMOTE OR APPROVED EQUAL =a STATE OF �., SLEEVE RESETISTATUS. 16 GAUGE SHEET METAL STRAPS 'o�i.M'UL\M1.'" 4�0 'oEdJfpMA...... � SJOINT. SLEEVE TO DUCT BUILT UP ROOF, EXISTING D. PROVIDE END SWITCHES TO MONITOR DAMPER POSITION. S ROOF DECK, EXISTING TRANSITION AS REQUIRED Q p E. PROVIDE REMOTE TEST SWITCH FOR TESTING PURPOSES AT GROUND LEVEL. MOUNTING ANGLES 7" NEOPRONE PADS OR VAV TERMINAL UNIT Seals 8226119 RESTRAINED SPRING ISOLATORS MAX.) n— �1 FIRE WE DAMPER INSTALLATION DETAIL SCALE: N.T.S. SUPPLY DUCT CONICAL SPIN -IN TAP WITH SQUARE DAMPER ROD& DAMPER OPERATOR WITH LOCKING QUADRANT. PROVIDE SHEETMETAL STANDOFF TO CLEAR INSULATION. CEILING SURFACE MOUNT TYPE LAY -IN TYPE GRILLE OR DIFFUSER NOTES: 1. REFER TO ARCHITECTURAL CEILING PLANS FOR CEILING TYPES AND COORDINATION OF CEILING DIFFUSER LOCATIONS. 2. USE BOTTOM TAP CONNECTION ONLY IF SIDEWALL BRANCH RUNOUT CONNECTION METHOD IS NOT POSSIBLE. %1 BOTTOM TAP SUPPLY AIR DEVICE CONNECTION DETAIL SCALE: N.T.S. SUPPLY AIR DUCT STEAM DISPERSION MANIFOLD LOW PRESSURE STEAM LINE DOMESTIC COLD WATER MAKE-UP FOR STEAM. REFER TO PLUMBING FOR CONNECTION. HUMIDIFIER L PAD MOUNTED CONDENSING UNIT SCALE: N.T.S. NOTE: 1. PROVIDE DOOR WITH I" THICK INSUATON. 2. PROVIDE REMOVABLE DOOR WITH CAM LATCHES. 3. IN ROUND DUCTS, PROVIDE TAP TO TRANSITIONS TO SQUARE DOOR. 4. REFER TO PLANS FOR DOOR SIZE WHEN DOOR IS LOCATED IN HORIZONTAL PLANE. 5. DOOR HEIGHTTO BE 2" LESS THAN DUCT HEIGHT. 6. BASIS OF DESIGN: AIR BALANCE FSA-101-H FOR DOORS IN MEDIUM PRESSURE DUCTWORK AND AIR BALANCE FSA-101 FOR DOORS IN LOW PRESSU RE DUCTWORK. SHEET METAL DUCT ACCESS DOOR SCALE: N.T.S. CONDENSATE DRAIN LINE HUMIDIFIER TANK I A SLOWDOWN DRAIN will 314" TO FLOOR DRAIN. TERMINATE WITH AIR GAP. SECONDARY DRAIN PAN UNION (TYP.) STEEL SPRING VIBRATION DOMESTIC COLD WATER FOR ITYP ISOLATOR ICAL(MN. 4) ROD, SECURE TO S STRUCTURE WITH TEMPERED CONDENSATE TEMPERING. DOUBLE NUTS,TYPICAL.(MIN. OF 4). CONDENSATE TO REFER TO PLUMBING FOR DISCONNECT— DRAIN (MAX. 1200F) CONNECTION. THERMOSTATIC TEMPERATURE CONTROL VALVE (BY FLEXIDLECONECTION, AFTERCOOLER MFR.) TYPICAL MANUAL DRAIN VALVE (NORMALLY CLOSED) CONDENSATE AFTERCOOLER (BY FULL SIZE OF AFTERCOOLER HUMIDIFIER DO INNCCN CONNECTION, ROUTE MANUFACTURER) / AIRFLOW NOTE: STEAM CONDENSATE, WATER AND DRAIN LINES SIZED PER MANUFACTURER'S INTAKE DUCT, RECOMMENDATIONS. INSULATE STEAM, ISCHARGE DUCT, FOR SIZE CONDENSATE AND DRAIN LINES AS SPECIFIED. SEE PLANS FOR SIZE. RELEASED FOR CONSTRUCTION 8 INLINE FAN DETAIL Subject to compliance with all regulations �J SCALE: N.T.S. of State and local Codes TEAM HUMIDIFICATION SYSTEM DETAIL City of Camel �VT�'�Da141WML DATE: 06/07/19 SUPPLYAIRDUCT ELEVATION VAV TERMINAL UNIT INSTALLATION DETAIL �J SCALE: N.T.S. (6" MAX. TYP.) SLEEVE WRAP NTH 1"- MIN. OR EQUAL TO EXTERNAL J�L � INSULATION. TAPE& SEAL (TVP.) EXTERNALLY WRAPPED DUCT N� AIRFLOW FIRE DAMPER PRIMARY AIR DUCT METAL NOSING ON DOWNSTREAM SIDE U.L. APPROVED SLIP JOINT(TYP. 4 SIDES) DUCTACCEESDOOR. REF4I108.02 RETAINING ANGLE PER MANUFACTURERS EXTERNALLY WRAPPED DUCT LISTED INSTRUCTIONS THERMAL EXPANSION SPACE TO BE AS RECOMMENDED SLEEVE INSULATE TO PREVENT CONDENSATION BY MANUFACTURER TO INSURE ILL. APPROVAL NOTE: 1. STYLE-B, DYNAMIl 2. STYLE -A, DYNAMIC RATED ALLOWED AT GRILLES. 3. SEE SPECS FOR DETAILS. 4. PROVIDE INTEGRAL SQUARE TO ROUND TRANSITION WHERE ROUND DUCT IS SHOWN ON PLANS. �1 FIRE DAMPER INSTALLATION DETAIL ~J SCALE: N.T.S. DIRTY FILTER PANEL INCHES OF WATER INCHES OF WATER F_ E I f RTU-1 AHU-1 MANOMETER LOCATE AT NURSE STATION DIRTY FILTER PANEL DETAIL �J SCALE: N.T.S. ISSUED FOR BID & PERMIT F— O 0 cc M U C o Z Q� E J W W C Q 03 U s_ (T5 C-) � Y QD C I1 � J QJ W J _ QJ N CD p ¢ 2 _ _ aJ U0 NJ 00 E7 � = r No Rewbon Date Project Number. 3018082 One 0226/2019 SheETide and Number. M-802 DETAILS - MECHANICAL