Loading...
HomeMy WebLinkAboutP-701-SCHEDULES---PLUMBING-Rev.0PLUMBING SYMBOLS ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS SYMBOLS ARE SHOWN SCHEMATIC AND MAY NOT BE TO SCALE. SYMBOL DESCRIPTION EXISTING PIPING/FIXTURES/EQUIPMENT TO REMAIN EXISTING PIPING/FIXTURES)EQUIPMENT TO BE REMOVED -.- DOMESTIC COLD WATER PIPING DOMESTIC HOT WATER PIPING -- DOMESTIC HOT WATER RETURN PIPING -RCW- RELOCATED DOMESTIC COLD WATER PIPING SCW- SOFTENED DOMESTIC COLDWATER PIPING PIPING UP PIPING DOWN F WET -PIPE FIRE PROTECTION PIPING DF DRY -PIPE FIRE PROTECTION PIPING - G - NATURAL GAS PIPING LPG LIQUEFIED PETROLEUM GAS VV WATER SERVICE DIRECTION OF FLOW GATE VALVE a BUTTERFLVVALVE BALL VALVE GLOBAL VALVE TEMPERATURE AND PRESSURE RELEIF VALVE ( GAS COCK PRESSURE REGULATING VALVE t8w - CHECKVALVE HYDRAULIC SHOCK ARRESTOR UNION HOSE BIBB OR HYDRANT OH THERMOMETER -D- INDIRECT WASTE PIPING -SS- SANITARY SEWER PIPING SANITARY VENT PIPING -Rn PRIMARY ROOF DRAIN LEADER OD OVERFLOW ROOF DRAIN LEADER -SD STORM DRAIN PIPING BELOW GRADE -SSD- SUBSOIL DRAIN PIPING -AW- ACIDWASTEPIPING ----AV---- ACID VENT PIPING GW GREASE WASTE PIPING P-TRAP FLOOR DRAIN WITH P-TRAP FLOOR SINK WITH P-TRAP HUB DRAIN WITH P-TRAP HCUI FLOOR CLEANOUT OR GRADE CLEANOUT TI uwo­CLEANOUT WCO OR WALL CLEANOUT -TP- TRAP PRIMER SUPPLY -MC MEDICAL GAS PIPING -MO- MEDICAL OXYGEN PIPING ® MEDICAL GAS VALVE BOX OR MEDICAL GAS OUTLET MEDICAL GAS PIPING DOWN IN WALL MEDICAL GAS RISERS OR PIPING UP IN WALL B CONNECT TO EXISTING PLUMBING ABBREVIATIONS AFF ABOVE FINISHED FLOOR Hi HOT WATER RETURN AFG ABOVE FINISHED GRADE OD OVERFLOW DRAIN A/C ABOVE CEILING CON OVERFLOW DOWNSPOUT NOZZLE B/F BELOW FLOOR FIRM PRESSURE REDUCING VALVE BFF BELOW FINISHED FLOOR RD ROOF DRAIN BIG BELOW GRADE SO STORM DRAIN BRF BELOW RAISED FLOOR SS SANITARVSEWER CO CLEANOUT SV SANITARVVENT CW COLD WATER TP TRAP PRIMER DCO DOUBLE CLEANOUT VTR VENT THRU ROOF DS DOWNSPOUT (E) EXISTING TO REMAIN FCO FLOOR CLEANOUT (D) EXISTING TO BE RELOCATED FD FLOOR DRAIN (R) RELOCATED FROM EXISTING FDC FIRE DEPARTMENT CONNECTION FS FLOOR SINK GCO GRADE CLEANOUT GC GENERAL CONTRACTOR GW GREASE WASTE HW HOT WATER RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel DATE: 06/07/19 PLUMBING FIXTURE SCHEDULE WC1 WATER CLOSET (ACCESSIBLEH PUBLIC & STAFF RESTROOMS(FLOOR MOUNTED FLUSH VALVE) PROFLO MODEL #PF1723WH HIGH EFFICIENCY FLUSH VALVE W/ SIPHON JET FLUSHING, 17" HIGH ADA BOWL, 1-12" TOP INLET SPUD AND 11-1)2" X 13" WATER SURFACE. ZURN MODEL Z6000 MODEL FLUSH VALVE W/ 1.6 GALLON LOW CONSUMPTION FLUSH, SWEAT SOLDER KIT AND VAST WALL FLANGE. BEMIS COMMERCIAL EXTRA HEAVY DUTY PLASTIC TOILET SEAT MODEL #1655CT(WHITE), OPEN FRONT LESS COVER. PROFLOW PFWR HEAVY DUTY WAX BOWL RING. PROFLO PFC2110RWLA CLOSET BOLT KIT. LI WALL HUNG LAVATORY ADA (PATIENT) PROFLO MODEL #PF541419"X17" WALL HUNG LAVATORY, ADA COMPLIANT, ANTI SPLASH RIM, WALL MOUNT BRACKET INCLUDED, CONCEALED FRONT OVERFLOW, WITH 3 FAUCET HOLES, 4" CENTERSET LAVATORV(WHITE). CHICAGO MODEL # 895S17GNBAE29VAB DECK MOUNTER LAVATORY FAUCET W/ 4" FIXED CENTERS AND 4"WRIST BLADES. INCLUDE OFFSET LAVATORY GRID DRAIN ANGLE STOPS, LEAD FREE FLEXIBLE CONNECTORS, ESCUTCHEONS, WATER SAVER TRAP PRIMER AND TRAP COVER. L2 WALL HUNG LAVATORY (PUBLIC) PROFLO MODEL #PF5414 19"X17" WALL HUNG LAVATORY, ADA COMPLIANT, ANTI SPLASH RIM, WALL MOUNT BRACKET INCLUDED, CONCEALED FRONT OVERFLOW, WITH 1 FAUCET HOLE, 4" CENTERSET LAVATORV(WHITE). SLOAN MODEL #SF- 2150 ELECTRONIC SENSOR FAUCET, BATTERY OPERATED, 0.5GPM W/ MECHANICAL MIXING VALVE. INCLUDE OFFSET LAVATORY GRID DRAIN, ANGLE STOPS, FLEXIBLE CONNECTORS, ESCUTCHEONS, WATER SAVER TRAP PRIMER AND TRAP COVER. S1 (EXAM SINKS, EMERGENCY TREATMENT SINK, NOURISHMENT SINK, SUPPLIES SINK) PROFLO MODEL #PFSR171963 STAINLESS STEEL SINK W/ 3 FAUCET HOLES, 4" CENTERS' CHICAGO MODEL #786E29- 245ABCP DECK MOUNTED FAUCET WITH 2.2 GPM NONAERATING OUTLET WITH 4" VANDAL PROOF WRISTBLADES' MCGUIRE 8912C P-TRAP AND MCGUIRE BV2165 SUPPLIES INCLUDE FLEXIBLE CONNECTORS. 82 (LAB SINK, SOILED UTILITY SINK) PROFORM PFS42521553C STAINLES STEEL SINK W/ 3 FAUCET HOLES, 4" CENTERS ° CHICAGO MODEL #786E29-245ABCP DECK MOUNTED FAUCET WITH 2.2 GPM NON -AERATING OUTLET WITH 4" VANDAL PROOF WRISTBLADES'MCGUIRE 8912C P-TRAP, MCGUIRE BV2165 SUPPLIES. INCLUDE FLEXIBLE CONNECTORS. S3 (BREAK ROOM SINK) ELKAY #LRADQ19196519"X19", 18 GAUGE STAINLESS STEEL SINGLE COMPARTMENT SINK DRAIN CENTERED IN REAR, 8" CENTERS, 3 HOLE PUNCH *PROFLO MODEL #PFXC4111 SINGLE HANDLE KITCHEN FAUCET W/ SPRAYER, 1.5 GPM. MCGUIRE MODEL#H-2165 SUPPLY KIT WITH CHROME PLATED ANGLE STOP WITH ROUND W HEEL HANDLES, TWO 12" FLEXIBLE RISERS AND TWO CRHOME PLATED WALL ESCUTCHEONS McGUIRE MODEL#8912 ADJUSTABLE CHROME PLATED P-TRAP WITH SET SCREW, ESCUTCHEON AND CLEANOUT PLUG, MCGUIRE MODEL #151 BRASS BASKET STRAINER. S4 (POC LAB) ELKAY #DLR19191 OPD 18 GAUGE STAINLESS STEEL SINGLE COMPARTMENT SINK DRAIN CENTERED IN REAR, 8" CENTERS, 3 HOLE PUNCH' CHICAGO MODEL #786-E29-245ABCP DECK MOUNTED FAUCET WITH 2.2 GPM NON -AERATING OUTLET WITH 4" 4" VANDAL PROOF WRISTBLADES' MCGUIRE HD1151 W C GRID STRAINER, MCGUIRE 8912C P-TRAP, MCGUIRE BV2165 SUPPLIES. SHi REFER ARCHITECTURAL DRAWINGS FOR SHOWER ENCLOSURE SPECIFICATIONS' DELTA MODEL#DT13H3331.5GPM SHOWER HEAD, SUPPLY ELBOW WITH WALL FLANGE, 24" SLIDE BAR AND 60" HOSE WITH HAND HELD SHOWER.' JAY R SMITH 2705AO5NB DRAIN' CSS1 KOHLER "CAMERTON"K-12867 WALL HUNG CLINICAL SERVICE SINK, 21-1/2"Lx25"W,1-1/2" TOP SPUD, VITREOUS CHINA, WHITE BLOW-OUT ACTION FLUSHING RIM, KOHLER K-13W LOOSE SINK STRAINER, KOHLER K-8935 STAINLESS STEEL RIM GUARD. PROVIDE ZURN Z1217 SERVICE SINK SUPPORT SYSTEM WITH FITTING.. ZURN Z6017 MODEL EXPOSED AQUAFLUSH, WITH HANDLE ON FRONT OF FLUSH VALVE. ZURN Z843D4LVB-PESX7-FT-YJ SERVICE SINK FAUCET, POLISHED CHROME - PLATED CAST BRASS 8" SINK FAUCET WITH QUARTER -TURN CERAMIC DISC CARTRIDGES, 3/8" SHORT SWIVEL INLETS PROVIDING ADJUSTABLE CENTERS FROM 7-1/4" TO 8-3/4", INTEGRAL SERVICE STOPS AND A 6" CENTERLINE CAST BRASS PLAIN END SPOUT, PAIL HOOK, A FLUSH TUBE SPOUT BRACE AND WALL BRACE. UNIT SHALL BE FURNISHED WITH 4" VANDAL -RESISTANT COLOR -CODED METAL WRIST BLADE HANDLES. BEDPAN WASHER: BURN Z877P2-LKS-HK3H2 POLISHED CHROME PLATED CAST BRASS WASHER WITH A QUARTER TURN CERAMIC DISC CARTRIDGE, A LOOSE KEY STOP WITH A REMOVABLE BRASS TEE HANDLE AND AVANDAL RESISTANT COLOR -CODED METAL FOUR ARM HANDLE, WITH VACUUM BREAKER, A HAND-HELD 4' VINYL SPRAY HOSE W ITH AN ANGLED INSULATED 6" HANDLE AND HOOK. MS1 PROFLO MODEL PFMB 242424"X24" MOP SERVICE BASIN WITH INTEGRAL MOLDED DRAIN, ZURN MODEL#7843M1-RC SERVICE FAUCET. PROVIDE WITH CHECKSTOP AND SERVICE STOPS, VACUUM BREAKER, LEVER HANDLES, WALL BRACE AND AT GARDEN HOSE OUTLET, PROFLO MODEL #PF245 MOP HANGER, T&S B-0654 STAINLESS STEEL HOSE BRACKET AND HOSE. NFWH ZURN Z1305 NON -FREE WALL HYDRANT WITH HOSE CONN ECTION, INTEGRAL VACU UM BREAKER, "IT HANDLE KEY AND STAINLESS STEEL BOX WITH FULL 180 DEGREE COVER OPENING. INSTALL AT 24" AFF, UNLESS NOTED OTHERWISE. FD1 JAY R SMITH"2005L-AOIBNB CAST IRON FLOOR DRAIN, TWO PIECE BODY WITH FLANGE, BOTTOM OUTLET, 6°ROUND NICKEL BRONZE STRAINER AND TRAP PRIMER CONNECTION IN COMPLIANCE WITH ASSE 1072. SH-2 DECONTAMINATION SHOWER(ADA COMPLAINT) SHOWER VALVE WITH PRESSURE AND TEMPERATURE MIXING VALVE "POWERS ES♦'-F727 C727' VISGUARD' COMBINATION VALVE W ITH BATTERY OPERATED LCD TEMPERATURE READOUT. 4 GPM CAPACITY WITH HIGH TEMP LIMIT STOP, SPEAKMAN VS 123014 CHROME COMBINATION FIXED AND HAND-HELD SHOWER HEADS WITH VS-111 DIVERTER AND VS153 ADA SLIDE BAR, 60" CHROME HOSE. ASSE 1016 LISTED. FS WATTS DRAINAGE MODEL #FS-740 12"X8" SQUARE DEEP SANITARY FLOOR SINK WITH WHITE PROCELAIN ENAMEL COATED INTERIOR, LOOSE SET PORCELAIN ENAMEL COATED CAST IRON GRATE, ALUMINUM DOME BOTTOM STRAINER, AND NO HUB OUTLET, HALF GRATE UNLESS NOTED OTHERWISE. TO WATTS DEAD LEVEL DX PRE SLOPED TRENCH DRAIN SYSTEM WITH 12" WIDE X BY LONG DUCTILE IRON FRAME. LIVE STABILIZED CHANNELS WITH 4" NO HUB OUTLET. SYSTEM SHALL BE FRAMED -ANCHORED, TO INCLUDED FRAME CONNECTORS, GRATE LOCKDOWNS AND CONSTRUCTION COVERS. PROVIDE DUCTILE IRON GRATE. EW DECK MOUNTED EYE WASH. BRADLEY S19465EFW EYEWASH/DRENCH HOSE UNIT. DECK MOUNTED WITH UNDER COUNTER HOSE GUIDE BRACKET. TMV MODEL BS19-200 THERMOSTATIC MIXING VALVE TO DELIVER TEPID WATER AS PROVIDED BY ANSI Z358.1-2014 W/ WALL MOUNT BRACKET. SS-1 ADVANCED TABCO MODEL#7-PS-62 HANDS FREE HAND SINK W ITH KNEE OPERATED VALVE. 18 GAUGE 304 STAIN LESS STEEL WITH NO DROP COUNTERTOP EDGE, SINGLE KNEE VALVE AND LEAD FREE FAUCET INCLUDED. 31/2" BASKET DRAIN INCLUDED. WE-1 GUY GRAY GALVANIZED OUTLET BOX MODEL NO. FBI RECESSED IN WALL. IMCB-1 GUY GRAV#MIEIAB ICE MAKER CONNECTION BOX. CO JR SMITH#4472-U STAINLESS STEEL CLEANOUTS, THREADED PLUG WITH COVER, VANDAL PROOF SCREWS. SA JAY R SMITH-5OOO SERIES HYDROTROL ALL STAINLESS STEEL SHOCK ABSORBERS INSTALLED AT ALL SOLENOID, REMOTE OPERATED OR QUICK CLOSING VALVES AND AT EACH PLUMBING FIXTURE OR BATTERY OF PLUMBING FIXTURES. INSTALL ON BOTH HOT AND COLD WATER BRANCH LINES IN AN UPRIGHT POSITION AS CLOSE AS POSSIBLE TO THE VALVE OR VALVES BEING SERVED. SIZES AND LOCATIONS AS INDICATED ON DRAWINGS. TP J.R. SMITH PRIME-EZE#2698 WATER SAVER P-TRAP WITH TRAP PRIMER. TG J.R. SMITH TRAP GUARD#2692 QUAD CLOSE"STINK STOPPER"TRAP SEAL DEVICE.COMPLIANCE WITH ASSE 1072. GENERAL NOTES: 1. VERIFY ALL MOUNTING HEIGHTS WITH ARCHITECTURAL DRAWINGS. 2. ALL LAVATORY P-TRAPS SHALL HAVE CLEANOUT PLUGS. 3. ALL PLUMBING FIXTURES MUST CONFORM TO CURRENT WATER CONSERVATION REGULATIONS. 4. ALL FIXTURES SHALL HAVE STANDARD FINISHES, UNLESS NOTED OTHERWISE. 5. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS, FLOOR SINKS AND INDIRECT CONNECTIONS UNLESS NOTED OTHERWISE. 6. PROVIDE ALL DRAIN COVERS, ESCUTCHEONS, AND MISCELLANEOUS TRIM ITEMS FORA NEAT APPEARANCE. 7. ALL MOUNTED HEIGHTS SHALL BE VERIFIED WITH THE ELEVATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS. 8. ALL PLUMBING FIXTURES MUST MEET ADA REQUIREMENTS. 9. ALL FAUCETS WITH WRIST BLADE HANDLES SHALL BE INSTALLED SUCH THAT THE BLADE HANDLES ARE PARALLEL TO THE BACK LEDGE OF THE SINK OR LAVATORY WHEN IN "OFF" POSITION. ELECTRIC WATER HEATER SCHEDULE SYMBOL LOCATION SERVES STORAGE STORAGE TANK PH RECOVERYVOLT/PHASE ANUFACTURE OPERATING WEIGHT GALLONS TEMP DIMENSIONS � 100°F. RISE KW MODEL N0. 48OVGP WHi HK BUILDING BO 740 24"DX 49 12 KW TOTAL AO SMITH 211 LBS 142 593/8"H. SIMULTANEO DEN-80 US OPERATION ' MAINTAIN PROPER CLEARANCE AROUND UNIT TO COMPLY WITH APPLICABLE CODES AND MANUFACTURER'S RECOMMENDATIONS FOR SERVICE ACCESS. ° COORDINATE ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING AND INSTALLATION. CIRCULATION PUMP SCHEDULE SYMBOL LOCATION SERVES TYPE GPM TDH HP RPM VOLTS/PHASE MANUFACTURER (FT) MODEL NO. CP1 HK 142 WATER IN -LINE 6 15 1/12 2750 120/1 GRUNDFOS HEATER UP26-96BF EXPANSION TANK SCHEDULE SYMBOL LOCATION TANK TOREDWATER PRE -CHARGE INSTALLATION TANK PRESSURE MANUFACTURER CAPACITY TEMP ('F) PRESSURE(PSI) CONFIGURATION RATING (PSI) MODEL NO. ET -I 2.1 140 F 55 SUSPENDED 150 A TTSROOL 742 THERMOSTATIC MIXING VALVE SCHEDULE HOTWATER I LENDEDWATEF PRESSURE SENSING MANUFACTURER SYMBOL LOCATION NLET TEMP. (°F) TEMP.(OF) DROPTHRU RANGE MODEL N0. REMARKS SYSTEM (GPM) LEONARD -HIGH LOW THERMOSTATIC MIXING VALVE, LOCKING TEMP REGULATOR, Tel HK 140 110 20 29 #TM-18652OB-LF OUTLET BALL VALVE WITH THERMOMETER/PRESSURE GAUGE, 3/4"RETURN & 142 LOOPITHERMOMETER AND BALL VALVE, INTEGRAL COMBO CHECK STOPS TMV2 - LOCKING TEMP REGULATOR, SWARM, MOUNTED ON UN ISTRUT MIXING VALVE MUST CONFORM TO ASSET 017. -INSTALL BOTH TMV-1 AND TMI IN PARALLEL ON WALL FOR REDUNDANCY AND SERVICING. PROVIDE SHUT-OFF VALVES ON INLET FOR BOTH COLD AND HOT WATER ON EACH TMV AND ON BLENDED WATER OUTLET FOR EACH TMV. REFER TO DETAIL 08/P-801 FOR PIPING DIAGRAM, TMI L2 110 105 20 0.5-7.0 LEONARD -PROVIDE CHECKS ON HOT AND COLD WATER SIDE OF VALVE. MIXING VALV - #Z70 MUST CONFORM TO ASSE 1070 MEDICAL VACUUM PUMP SCHEDULE NFPA SYSTEM ON TANK SYSTEM SYSTEM SYMBOL LOCATION PUMP SCFM STANDBY PUMP WEIGHT SQ. FT. HP SIZE F.L.A VOLTAGE/ BTUH SOUND MANUFACTURER @ 19'HG SCFM @ 19"HG LBS. REQUIRED GAL, 46D V PHASE LEVEL DBA MODEL NO. VACUUM BEACON MEDAS BEACONVEDAS All PUMPROOM 5 5 348 6.3 1.5 30 3.1 4W/3 3,054 67 VDVOl WATER DEMAND SCHEDULE FIXTURE TYPE QUANTITY WSFU VALV TOTAL WSFU VALUE WATER CLOSET (FLUSH VALVE TYPE) 7 10 70.0 LAVATORY 8 2.0 16.0 SINK 18 2.0 36.0 MOP SINK 1 3.0 3.0 SHOWER 1 3.0 3.0 CLINICAL SERVICE SINK 1 10.0 10.0 (FLUSH VALVE) 136.00 WSFU= 77 GPM TOTAL =2"CW SERVICE @ <8FT./SEC MAX ZONE VALVE BOX SCHEDULE ZONE VALVE BOX SERVING OXYGEN AIR VACUUM NB-1 CT & PAID 12" 12" 314" NB-2 TREATMENTEXAM 314" 314" 1-114" NB3 FT EXAM 3/4" 314" 1-114" PLUMBING FIXTURE CONNECTION SCHEDULE FIXTURE TYPE WASTE TVENT CW HW WATER CLOSET 4" 2" 1" - LAVATORY 2" 2" 1124 1Q" ELEC. WATER COOLER 2" 2" 1/Z' ' CLINICAL SERVICE SINK 4" 2" 1-1/4" 3M" SHOWER 2" MOPSINK 3" 2" 3/4" 314" SW ASSOCIATES Tn GonsWfing Engineers l- LU Z E 1700 Pacific Avelac Z W e S s Darts, TX 75201 Tel: 214.397.0211 mrww.Swamgmars.min- w d = PRDJECT#18209 �wH PLUMBING GENERAL NOTES:ZJ ;:=V 12 ZOO F PIP - A PROVIDE COMPLETE PLUMBING SYSTEM AS REQUIRED FOR THE SCOPE OF LLJ L.LQ THIS CONTRACT. FINAL SYSTEM DESIGN SHALL BE BUILT TO COMPLY WITH o CURRENT PLUMBING, LOCAL CODE DEPARTMENT OF HEALTH, NFPA, AND t OSHA REQUIREMENTS. B. ALL CONSTRUCTION DEBRIS BY THE c �' z y o RWISE.OSEDOF EDSHALL CONTRACTOR,UNLESS NOTED OTHERWISE. OTHERWISE. r g C. THERE SHALL BE NOTHING ABANDONED IN PLACE, UNLESS SPECIFICALLY - 0 E E 2 IDENTIFIED AS SUCH. - D. THESE PLANS ARE DIAGRAMMATIC IN NATURE, CONTRACTORS SHALL m O e INCLUDE APPROPRIATE ALLOWANCES FOR OFFSETS AS REQUIRED TO m ACCOMMODATE VERTICAL AND HORIZONTAL VARIATIONS IN THE LOCATIONS AND ELEVATIONS OF DUCTWORK, PIPING AND EXISTING CONDITIONS. H0101"Ii E. EACH TRADE SHALL COORDINATE THE ROUTING AND INSTALLATION OF HIS tYaN G. PIq�'%. IIS Pill, .%e 0;.I WORK WITH THAT OF ALL OTHER TRADES THROUGH THE GENERAL `3-'i2• f0 •-1 CONTRACTOR. IN ANY INSTANCES OF CONFLICT, SYSTEMS REQUIRING 3 ' % = "GRADE"OR"SLOPE"FOR DRAINAGE (SANITARY SEWER, SANITARY VENT, = 1NO.PE10403225 EQUIPMENT DRAINS, ETC...) SHALL HAVE PRIORITY. ea STATE OF ;_ c F. PENETRATIONS OF WALLS OR FLOORS FOR THE PASSAGE OF PIPING, OR OTHER EQUIPMENT SHALL BE PROPERLY SEALED AFTER INSTALLATION OF EQUIPMENT. FIELD VERIFY EXISTING WALL PENETRATIONS AND PROPERLY SEAL AS REQUIRED TO MAINTAIN WALL OR FLOOR RATING. /I G. PROVIDE ALL EQUIPMENT,MATERIAL, LABOR, SUPERVISION, COSTS AND SERVICES REQUIRED TO INSTALL COMPLETE AND WORKING Seals SVSTEMSINCLUDING ALL ITEMS AND APPURTENANCES NECESSARY, REASONABLE, INCIDENTAL OR CUSTOMARILY INCLUDED, EVEN THOUGH EACH AND EVERY ITEM IS NOT SPECIFIED OR SHOWN ON DRAWINGS. H. ALL WOW DOCUMENTS, INC UDNGADDENDA,ANDAPPLICABLECCODESANDLL COMPLY WITH THE REQUIREMENTS OF THE TRACT ISSUED FOR BID & STANDARDS.PERMIT I. PROVIDE ACCESS TO ALL CONCEALED EQUIPMENT AND VALVES. COORDINATE LOCATION OF ACCESS PANELS WITH ARCHITECT. J. ALL FLOOR DRAINS, FLOOR SIN KS, H UB DRAINS, OR INDIRECT CONNECTIONS SHALL BE PROVIDED WITH JR SMITH QUAD CLOSE IN LIEU OF TRAP PRIMER. K. VENT STACK SHALL BE LOCATED A MINIMUM OF 25'-0" AWAY FROM ANY HVAC OUTSIDE AIR INTAKE. (HOSPITAL) L. PROVIDE PVC SLEEVE FOR ANY PORTION OF THE GAS PIPING THAT IS ROUTED CD IN BUILDING, UNDER CONCRETE SLAB OR WALKWAY (TYPICAL) O M. EXTEND SANITARY SEWER, DOMESTIC WATER, FIRE, STORM AND GAS PIPING AS REQUIRED IN ORDER TO CONNECT TO STUB -OUT PROVIDED BY CIVIL. T C) N. UTILITIES OR SHALL BE INSTALLED PER THE MANUFACTURERS RECOMMENDATIONS. O.J >CD) 0. COORDINATE ALL FLOOR DRAIN, FLOOR SINK, HUB DRAIN, WALL AND FLOOR CLEANOUT LOCATIONS WITH ARHICTECT/OWNER AND EQUIPMENT VENDOR NC BOOK PRIOR TO INSTALLATION. C L.I..I P. PROVIDE AND INSTALL BACKFLOW PREVENTERS ON SUPPLY LINES SERVING OWNER FURNISHED EQUIPMENT IN ACCORDANCE WITH LOCAL AND STATE p46 CODES. REFER TO SPECIFICATIONS. ROUTE DRAIN LINE FROM RPZ TO AN APPROVED LOCATION. a�D 0. DURING INSTALLATION FIELD MODIFICATIONS TO ROUTING MAY BE REQUIRED. U R. CONTRACTOR TO VERIFY ALL INVERT ELEVATIONS FOR NEW PIPING a--� CONNECTING TO CIVIL. NOTIFY ENGINEER OF ANY DISCREPANCIES. N S. NO PIPING SHALL RUN EXPOSED IN FINISHED AREAS. T. PROVIDE WALL CLEANOUTS ON ALL FLOOR DRAINS, FLOOR SINKS, HUB J DRAINS, FIXTURES, AND AT THE BASE OF ALL RISERS. MOUNT MINIMUM 12" - A.F.F. TO KEEP WALL CLEANOUT OUT OF BASEBOARDS. aD U. PROVIDE CHECK VALVES ON HOT AND COLD WATER SIDE BEFORE ALL THERMOSTATIC MIXING VALVES. V. PROVIDE SHOCK ARRESTOR'S AT ALL QUICK CLOSING VALVES PE R PLUMBINGCz CODE AND LOCAL CODE. C W. ANY PIPING LOCATED IN RETURN AIR PLENUM SHALL BE PLENUM RATED PER TDH, PLUMBING AND LOCAL CODE. X VERIFY FINAL VENDOR EQUIPMENT DRAWINGS WITH OWNER PRIOR TO INSTALLATION. Z. PROVIDE FUNNEL DRAINS ON BACKFLOW DEVICES. GENERAL FIRE PROTECTION NOTES: A. PROVIDE A COMPLETE AUTOMATIC WET PIPE FI RE SPRINKLER SYSTEM AS REQUIRED TO PROVIDE FULL COVERAGE FOR THE SCOPE OF THIS CONTRACT. FINAL SYSTEM DESIGN SHALL BE HYDRAULICALLY CALCULATED TO COMPLY WITH CURRENT NFPA 13, INTERNATIONAL FIRE CODE. LOCAL CODE/AMMENDMENTS AND INDIANA DEPARTMENT OF HEALTH FREESTANDING EMERGENCY MEDICAL CARE FACILITY LICENSING RULES. B. SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THEARCHRECT PRIOR TO ORDERING, PURCHASING, OR FABRICATION OF ANY FIRE PROTECTION EQUIPMENT. SHOP DRAWINGS SHALL INCLUDE: SPRINKLER DRAWINGS AND CALCULATIONS BEARING THE SEAL OF AREGISTERED PRD ESSIONAL ENGINER OR EQUIVALENT CONTRACTORS FIRE SPRINKLER CERTIFICATE SEAL AND APPROVAL STAMP OF LOCAL CODE AUTHORITY; SPRINKLER PIPING. SPRINKLER HEADS VAViEB; AND ACCESSORIES. SHOP DRAWINGS SWILL BE SUBMITTED TO AND APPROVED BY THE OWNERS INSURANCE UNDERWRITER PRIOR TO BEING SUBMITTED TO THE ARCHITECT. C. CONTRACTOR SHALL COORDINATE THE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF All FIRE PROTECTION EQUIPMENT WITH THE ELECTRICAL DRAWINGS AND SHALL FURNISH EQUIPMENTWTRED FOR THEVOLTAGESSHOWN THEREIN. D. All FIRE PROTECTION EQUIPMENT AND SYSTEMS SHAL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. 41 E. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND Z SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. PIPING HUNG FROM JOBTS SWILL BE HUNG FROM THE TOP CHORDS OF THE JOBTS. F. COORDINATE SPRINKLER TYPES WITH ARCHITECT PRIOR TO INSTALLMION. G. PROVIDE CONCEALED SPRINILERB CENTERED IN CEILING TILE. Project Number: 3018082 H. PROVIDE SIDEWALL SPRINKLERS INKRAY ROOM. Date: 02/262019 I. PROJIDEDRKPIPE SYSTEM FOR EXTERIOR CANOPIESAS REQUIRED. Sheet Title and Number'. P-701 SCHEDULES - PLUMBING