HomeMy WebLinkAboutS110-GENERAL-NOTES-Rev.0GENERAL NOTES GENERAL 1. THE STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE 2014 INDIANA BUILDING CODE. 2. THE LOADS THAT HAVE BEEN USED IN THE STRUCTURAL DESIGN INCLUDE THE FOLLOWING LIVE LOAD AT GROUND FLOOR 100 PSF LIVE LOAD AT ROOF 20 PSF SNOW LOAD DESIGN DATA: PER ASCE 7-10 1. GROUND SNOW LOAD, Pg: 20 PSF 2. SNOW EXPOSURE FACTOR, Ce: 1 3. SNOW LOAD IMPORTANCE, Is: 1.2 4. THERMAL FACTOR, Ct: 1 5. FLAT -ROOF SNOW LOAD Pm: 17 PSF 6. SLOPED ROOF SNOW LOAD Ps: 7PSF 7. SNOW DIAGRAMS: 3/51.3 WIND LOAD DESIGN DATA: PER ASCE 7-10 1. ULTIMATE DESIGN WIND SPEED: 120 MPH 2. NOMINAL DESIGN WIND SPEED: 93 MPH 3. RISKCATEGORY: IV 4. WIND EXPOSURE: B 5. INTERNAL PRESSURE COEFFICIENT: 0.18 6. COMPONENT AND CLADDING PRESSURE: 1/S1.3 SEISMIC LOAD DESIGN DATA: PER ASCE 7-10 1. RISKCATEGORY: IV 2. SEISMIC IMPORTANCE FACTOR, le: 1.5 3. MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETER Ss: 0.144 Si: 0.08 4. SITE CLASS: C 5. DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETER Ss: 0.115 Si: 0.091 6. SEISMIC DESIGN CATEGORY: C 7. BASIC SEISMIC -FORCE RESISTING SYSTEM(S): STEEL SYSTEM NOT SPECIFICALLY DETAILED FOR SEISMIC SYSTEM B. RESPONSE MODIFICATION COEFFICIENT(S): R=3 9. SEISMIC RESPONSE COEFFICIENT(S): 0.06g 10. DESIGN BASE SHEAR(S): 0.06xW 11. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE ALL LIVE LOADS HAVE BEEN REDUCED BASED ON TRIBUTARY AREAS IN ACCORDANCE WITH CODE PROVISIONS AND HAVE BEEN APPLIED TO BOTH ALTERNATE AND ADJACENT SPANS WHERE APPROPRIATE TO DERIVE GOVERNING CONDITIONS. DEAD LOADS HAVE BEEN CALCULATED TO INCLUDE THE ACTUAL WEIGHT OF ALL WORK SHOWN ON THE STRUCTURAL, MECHANICAL, ELECTRICAL AND ARCHITECTURAL DRAWINGS. NO OTHER EQUIPMENT SHALL BE PLACED ON OR HUNG FROM THE ROOF SYSTEM WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER. ROOF -MOUNTED HVAC UNITS SHALL BE PLACED WITHIN THE DESIGNATED AREAS SHOWN ON THE FRAMING PLANS. 3, COMPLETE SHOP DRAWINGS FOR THE STRUCTURAL WORK SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO COMMENCEMENT OF CONSTRUCTION, IN ACCORDANCE WITH THE SPECIFICATIONS. SUCH REVIEW BY THE ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF FULL RESPONSIBILITY FOR CORRECT FABRICATION AND CONSTRUCTION OF THE WORK. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR MATERIALS PURCHASED PRIOR TO REVIEW OF SHOP DRAWINGS. THE CONTRACTOR SHALL REVIEW AND STAMP ALL SHOP DRAWINGS PRIOR TO SUBMITTING THE DRAWINGS TO THE ARCHITECT/ENGINEER. 4. THE USE OF ELECTRONIC FILES OR REPRODUCTION OF THESE CONTRACT DOCUMENTS BY ANY CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR OR MATERIAL SUPPLIER IN LIEU OF PREPARATION OF SHOP DRAWINGS SHALL NOT BE PERMITTED. 5. ANY DEVIATION FROM, ADDITION TO, SUBSTITUTION FOR, OR MODIFICATION TO THE STRUCTURE OR ANY PART OF THE STRUCTURE DETAILED ON THESE DRAWINGS SHALL BE SUBMITTED IN WRITING TO THE ENGINEER FOR REVIEW. SHOP DRAWINGS THAT ARE SUBMITTED FOR REVIEW DO NOT CONSTITUTE "IN -WRITING" UNLESS IT IS CLEARLY NOTED THAT SPECIFIC CHANGES ARE BEING SUGGESTED. 6. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS NOT SHOWN AND FOR EXACT LOCATIONS OF ALL ARCHITECTURAL DETAILS. THE CONTRACTOR SHALL COMPARE THE STRUCTURAL AND ARCHITECTURAL DRAWINGS AND REPORTANY DISCREPANCIES TO THE ENGINEER PRIOR TO COMPLETION OF THE SHOP DRAWINGS. 7. THE CONTRACTOR SHALL VERIFYAND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS AT THE SITE AND SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN THE ACTUAL CONDITIONS AND INFORMATION SHOWN ON THE DRAWINGS BEFORE PROCEEDING WITH THE WORK. B. PRINCIPAL OPENINGS ARE SHOWN ON THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR SLEEVES, CURBS, INSERTS AND OTHER OPENINGS NOT SHOWN. THE CONTRACTOR SHALL PROVIDE FOR ALL OPENINGS, WHETHER SHOWN ON THE STRUCTURAL DRAWINGS OR NOT. SIZE AND LOCATION OF ALL OPENINGS SHALL BE VERIFIED BY THE CONTRACTOR. ANY DEVIATION FROM OPENINGS SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION FOR APPROVAL PRIOR TO CONSTRUCTION. 9. THE STRUCTURAL DRAWINGS ARE NOT TO BE SCALED FOR DETERMINATION OF QUANTITIES, LENGTHS, OR FIT OF MATERIALS. 10. THE GENERAL CONTRACTOR SHALL OBTAIN ALL CONTRACT DOCUMENTS & LATEST ADDENDA AND SUBMIT SUCH DOCUMENTS TO ALL SUBCONTRACTORS AND MATERIAL SUPPLIERS PRIOR TO THE SUBMITTAL OF SHOP DRAWINGS OR FABRICATION OF ANY STRUCTURAL MEMBERS. 11. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHODS OF CONSTRUCTION UNLESS SO STATED OR NOTED. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE WORKMEN AND OTHER PERSONS DURING CONSTRUCTION. 12. THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING AND SHORING OF ALL STRUCTURAL WORK AS REQUIRED FOR STABILITY OF THE STRUCTURE DURING ALL PHASES OF CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY CONDITION WHICH, IN HIS OPINION, MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE DISTRESS IN THE STRUCTURE. 13. CONSTRUCTION MATERIALS SHALL NOT BE STORED ON FLOORS OR ROOFS IN EXCESS OF THE DESIGN LIVE LOADS WHICH ARE INDICATED ON THE DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENFORCE THIS REQUIREMENT. IMPACT SHALL BE AVOIDED WHEN PLACING MATERIALS ON FLOORS OR ROOFS. 14, CONSTRUCTION SEQUENCE SHALL BE COORDINATED BY THE CONTRACTOR AS REQUIRED FOR INSTALLATION OF ALL STRUCTURAL COMPONENTS. 15. FIELD INSPECTION REPORTS SHALL BE SUBMITTED TO THE ENGINEER AS OUTLINED IN THE SPECIFICATIONS. INSPECTIONS SHALL BE PROVIDED BY A QUALIFIED AGENCY HIRED BY THE OWNER. CURTAINWALL & STOREFRONT CONNECTIONS I SUPPORT 1. GLAZED CURTAINWALL MANUFACTURER SHALL PROVIDE ALL BRACING AND CONNECTIONS TO THE STRUCTURE. CALCULATIONS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF INDIANA SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD FOR REVIEW. 1. STEEL JOIST DESIGN AND CALCULATIONS. 9 RTFFI CONNFCTION DFSIGNS AND CALCULATIONS. RELEASED FOR CONSTRUCTION ND CALCULATIONS. Subject to compliance With all regulations of State and Local Codes City of Camel ��GGs DATE: 06/07/19 CAST IN PLACE REINFORCED CONCRETE 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF ACT 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". 2. STEEL REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60, EXCEPT WELDED REINFORCEMENT WHICH SHALL CONFORM TO ASTM A706, GRADE 60. REINFORCEMENT SHALL NOT BE WELDED UNLESS SHOWN ON THE DRAWINGS. ALL HOOKS SHALL BE STANDARD ACI 90 DEGREE UNLESS NOTED OTHERWISE. 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 GRADE 65. ALL WELDED WIRE FABRIC SHALL BE SUPPLIED IN FLAT SHEETS, NOT IN ROLLS. LAP WELDED WIRE FABRIC A MINIMUM OF 2 CROSSWIRE SPACINGS. 4. ALL CONCRETE SHALL UTILIZE NORMAL WEIGHT AGGREGATE UNLESS NOTED OTHERWISE. 5. CONCRETE SHALL MEET THE FOLLOWING PERFORMANCE CRITERIA: 28 DAY CAMP. LOCATION STRENGTH (fc) SLUMP (A) MAX. W/C RATIO FOOTINGS 3000 PSI W-5" - GRADE BEAMS 4000 PSI 3"-5" 0.45 SLAB ON GRADE (b, c) 3000 PSI 3"- 5" 0.50 NOTES: a. CONCRETE SLUMPS GIVEN ARE AT THE POINT OF PLACEMENT. b. ALL EXTERIOR SLABS SHALL CONTAIN 3%-6% OF AIR ENTRAINMENT. c. MAXIMUM SLAB POUR SHALL NOT EXCEED A LENGTH OF 150 FEET IN EITHER DIRECTION NOR AN AREA OF 10,000 SQUARE FEET. 6. THE TESTING LABORATORY SHALL BE NOTIFIED AFTER THE MILD STEEL REINFORCEMENT AND EMBEDS ARE POSITIONED PRIOR TO EACH CONCRETE PLACEMENT. NO CONCRETE SHALL BE PLACED UNTIL THESE ITEMS ARE CHECKED AND APPROVED BY THE TESTING LABRATORY. 7. PERFORM SAWCUTS AS INDICATED ON THE FOUNDATION PLANS AS QUICKLY AS POSSIBLE AFTER PLACING CONCRETE WITHOUT DISLODGING AGGREGATE. ALL SAWCUTS SHALL BE COMPLETED WITHIN 8 HOURS OF CONCRETE PLACEMENT. SUSPENDED SLABS AND POST TENSION SLABS ON GRADE SHALL NOT HAVE SAWCUTS. STEEL 1. STRUCTURAL STEEL SHALL BE NEW STEEL AND SHALL CONFORM TO THE AISC 'SPECIFICATION FOR STRUCTURAL STEEL FOR BUILDINGS". BOLTED CONNECTIONS (UNLESS NOTED OTHERWISE) SHALL CONFORM TO THE REQUIREMENTS OF THE AISC "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS". 2. STEEL SHAPES AND FASTENERS SHALL TO THE ASTM SPECIFICATIONS BELOW: SHAPE ASTM WIDE FLANGE A992 CHANNELS A36 ANGLES A36 HSS A500 Gr. B PIPE A53 Dr.B PLATES A36(or A572 Gr. 50) BASE PLATES REF. SCHED. BOLTS ASTM HIGH STRENGTH BOLTS A325 N ANCHOR BOLTS F1554, GRADE 55 (WELDABILITY PER F1554 SUPPLEMENT) 3. ALL STRUCTURAL STEEL CONNECTIONS AND DETAILS SHALL CONFORM TO THE AISC"CODE OF STANDARD PRACTICE FOR STEEL, BUILDINGS AND BRIDGES." 4. WELDED CONSTRUCTION SHALL CONFORM TO AWS D-1.1,"STRUCTURAL WELDING CODE." WELDING PROCESSES AND OPERATORS SHALL BE QUALIFIED IN ACCORDANCE WITH AWS "STANDARD QUALIFICATIONS PROCEDURE." ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE E70XX, U.N.O. 5. SHEAR STUDS SHALL CONFORM TO ASTM A108, HEADED ANCHORS. 6. STEEL MEMBERS SHALL NOT BE SPLICED EXCEPT AS SHOWN ON THE DRAWINGS. 7. ALL STEEL BEAMS SHALL BE ERECTED WITH NATURAL CAMBER UP. B. ALL CONNECTIONS OF NON -COMPOSITE BEAMS SHALL BE DESIGNED BY THE FABRICATOR UNLESS OTHERWISE INDICATED. CONNECTIONS SHALL BE DESIGNED TO RESIST A FORCE OF 55 % OF THE AISC ALLOWABLE BEAM LOAD, OR THE REACTION SPECIFIED, WHICHEVER IS GREATER. ALL CONNECTION DESIGN REACTIONS SHALL BE NOTED ON THE SHOP DRAWINGS. 9. ALL EXTERIOR STEEL EXPOSED TO WEATHER, INCLUDING LINTELS, SHALL BE HOT -DIPPED GALVANIZED. FABRICATOR TO PREPARE MATERIAL TO BE GALVANIZED TO MEET THE GALVANIZER'S REQUIREMENTS AND THE SPECIFICATIONS. 10. CONNECTION DETAILS SHALL TAKE INTO CONSIDERATION CONSTRUCTION SEQUENCING AND POSSIBLE OBSTRUCTIONS FROM ADJACENT COMPONENTS SUCH AS RETAINING WALLS. 11. SUPPORTS FOR ROLL -DOWN SECURITY DOORS SHALL BE DESIGNED AND PROVIDED BY DOOR MANUFACTURER. DOORS SHALL NOT BE SUPPORTED FROM BUILDING COLUMNS WITHOUT PRIOR WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 12. GROUT AT STEEL COLUMN BASE PLATES SHALL BE NON -SHRINK, NON-METALLIC AGGREGATE TYPE, COMPLYING WITH ASTM C1107 AND CAPABLE OF DEVELOPING A MINIMUM COMPRESSIVE STRENGTH OF 7,000 PSI AT 28 DAYS. STEEL JOISTS 1. FABRICATION AND ERECTION OF ALL OPEN WEB STEEL JOISTS, JOIST GIRDERS, AND BRIDGING SHALL CONFORM TO THE STANDARDS OF THE STEEL JOIST INSTITUTE. 2. JOIST MANUFACTURER SHALL PROVIDE CAMBER IN CONFORMANCE WITH SA SPECIFICATIONS. 3. ALL BRIDGING SHALL BE WELDED OR BOLTED AT THE ENDS. ALL JOISTS SHALL BE WELDED AT THE ENDS, UNLESS SHOWN OTHERWISE. ALL JOIST GIRDERS SHALL BE BOLTED AT THE ENDS, UNLESS SHOWN OTHERWISE. BRIDGING SHALL BE DESIGNED FOR A NET WIND UPLIFTAS NOTED. 4. ANY HANGERS SUPPORTED FROM JOISTS SHALL BE LOCATED AT TOP OR BOTTOM CHORD PANEL POINTS AND SHALL BE CONNECTED WITHOUT FIELD WELDING OR DRILLING HOLES IN JOISTS. 5. MECHANICAL DUCTS, ELECTRICAL EQUIPMENT, CONDUIT, LIGHTING FIXTURES, AND PIPING SHALL NOT BE SUPPORTED FROM JOIST BRIDGING. 6. ALL PIPING LARGER THAN 4" DIAMETER RUNNING PARALLEL TO JOISTS SHALL BE SUPPORTED FROM A MINIMUM OF 2 JOISTS AND SUPPORTED AT PANEL POINTS ONLY. 7. ALL PIPING LARGER THAN 4" DIAMETER RUNNING PERPENDICULAR TO JOISTS SHALL BE SUPPORTED AT PANEL POINTS FROM AT LEAST EVERY SECOND JOIST. 8. PIPING LOADS EXCEEDING 4 PSF SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER. 1. ALL METAL DECKING SHALL COMPLY WITH THE SPECIFICATIONS OF THE STEEL DECK INSTITUTE FOR DESIGN AND ERECTION. GALVANIZED DECKS SHALL CONFORM TO ASTM A653. PAINTED DECKS SHALL CONFORM TO ASTM A1008. 2. METAL DECKING SHALL BE INSTALLED CONTINUOUSLY ACROSS 3 OR MORE SPANS. IF LESS THAN THREE SPANS ARE UTILIZED TEMPORARY SHORING MAY BE REQUIRED PER MANUFACTURER'S RECOMMENDATIONS. DECKING SHALL BE ATTACHED TO STEEL, JOISTS AND FRAMEWORK IMMEDIATELY AFTER ALIGNMENT. 3. UNLESS NOTED OTHERWISE, ROOF DECK SHALL BE 22 GAUGE, 1-1/2" WIDE RIB DECK (TYPE B), ASTM At 008 STRUCTURAL QUALITY, MINIMUM YIELD POINT OF 33,000 PSI, WITH MANUFACTURER'S STANDARD BAKED ON COATING. REF. 2/S130 FOR DECK GAUGES AND ATTACHMENT PATTERNS. MECHANICAL DECK FASTENERS MAY BE UTILIZED IN LIEU OF PUDDLE WELDS AT JOIST FRAMING AT THE DISCRETION OF THE STRUCTURAL ENGINEER OF RECORD. ATA MINIMUM, MECHANICAL DECK FASTENERS SHALL PROVIDE EQUAL OR GREATER DIAPHRAGM SHEAR STRENGTH STIFFNESS AND UPLIFT CAPACITY AS THE SPECIFIED PUDDLE WELD PATTERN, MECHANICAL DECK FASTENERS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD AND THE ARCHITECT TO APPROVAL PRIOR TO CONSTRUCTION. 4. ALL DECK IS TO BE FABRICATED TO RUN CONTINUOUSLY OVER ALL OPENINGS. DO NOT CUT OPENING IN DECK PRIOR TO INSTALLING SUPPORT FRAMING BELOW. 5. SUSPENDED CEILINGS, LIGHT FIXTURES,DUCTS, OR OTHER UTILITIES SHALL NOT BE SUPPORTED BY THE STEEL ROOF DECK. 6. DECK FINISH SHALL BE REPAIRED WITH TOUCH-UP PAINT IMMEDIATELY AFTER WELDING TO PREVENT CORROSION. COLD FORMED METAL FRAMING 1. COLD FORMED METAL FRAMING MANUFACTURER SHALL DESIGN THE COMPLETE METAL FRAMING SYSTEM, INCLUDING BUT NOT LIMITED TO BRACING AND CONNECTIONS TO THE METAL STRUCTURE, UNLESS SHOWN ON STRUCTURAL DRAWINGS. CALCULATIONS AND SHOP DRAWINGS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF INDIANA SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD FOR REVIEW. GENERAL CONTRACTOR SHALL PROVIDE ALL COLD FORMED METAL FRAMING AS REQUIRED. 2. WITH EACH TYPE OF METAL FRAMING REQUIRED, PROVIDE MANUFACTURER'S STANDARD STEEL RUNNERS (TRACKS), BLOCKING LINTELS, CLIP ANGLES, SHOES, REINFORCEMENTS, FASTENERS, AND ACCESSORIES AS RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED, AS NEEDED TO PROVIDE A COMPLETE METAL FRAMING SYSTEM. 3. FOR 16 GAUGE AND HEAVIER STUDS AND JOISTS, FABRICATE COMPONENTS OF STEEL SHEET WITH A MINIMUM YIELD POINT OF 50,000 PSI, CONFORMING TO ASTM A653 AND C955. 4. FOR 16 GAUGE AND HEAVIER TRACK, FABRICATE COMPONENTS OF STEEL SHEET WITH A MINIMUM YIELD POINT OF 33,000 PSI, CONFORMING TO ASTM A653 AND C955. 5. FOR 18 GAUGE AND LIGHTER STUDS, JOISTS, AND TRACK, FABRICATE COMPONENTS OF STEEL SHEET WITH A MINIMUM YIELD POINT OF 33,000 PSI, CONFORMING TO ASTM A653 AND C955. 6. PROVIDE MANUFACTURER'S STANDARD GALVANIZED FINISH TO METAL FRAMING COMPONENTS COMPLYING WITH ASTM A653. 7. THE COLD FORMED FRAMING DESIGN SHALL INCLUDE BUT SHALL NOT BE LIMITED TO THE FOLLOWING DESIGN ELEMENTS: WALL STUDS INCLUDING JAMB LOCATIONS HEADERS DESIGNED FOR GRAVITY AND LATERAL LOADING • TOP AND BOTTOM TRACKS INCLUDING ATTACHMENTS AT SLIP TRACKS ALL CONNECTIONS SHALL SPECIFY SIZE AND QUANTITY OF FASTENERS ANY BRACING OF METAL STUDS REQUIRED THAT IS NOT INDICATED ON THE STRUCTURAL DRAWINGS B. MAXIMUM ALLOWABLE DEFLECTION FOR VERTICAL LIGHT GAUGE MEMBERS BACKING BRICK IS U600 (U360 FOR OTHER MATERIALS). DEFLECTION CALCULATIONS SHALL BE BASED ON ABSOLUTE DEFLECTIONS (NOT RELATIVE DEFLECTIONS). 9. DEFLECTION OF VERTICAL STUDS WITH PARAPET SHALL BE CALCULATED BASED ON ABSOLUTE DEFLECTION, NOT RELATIVE DEFLECTION. 1. ALL REINFORCED MASONRY SHALL CONFORM TO THE PROVISIONS OF ACI 530.1/ASCE 6 (WITH EXCEPTIONS NOTED IN THE SPECIFICATIONS). CONSTRUCTION SHALL BE RUNNING BOND UNLESS NOTED OTHERWISE. 2. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 NORMAL WEIGHT UNITS WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1900 PSI. 3. MORTAR SHALL CONFORM TO ASTM C270, TYPE M OR S. AGGREGATES FOR MORTAR SHALL CONFORM TO ASTM C144. MORTAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 1800 PSI AT 28 DAYS. 4. GROUT SHALL CONFORM TO ASTM C476. AGGREGATES FOR GROUT SHALL CONFORM TO ASTM C-404. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS. 5. MASONRY CONSTRUCTION SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (fm) OF 1900 PSI AT 28 DAYS. 6. SPECIAL INSPECTION SHALL BE PROVIDED AS PRESCRIBED IN THE SPECIAL INSPECTION NOTES. 7. BOND BEAMS SHALL BE CONSTRUCTED WITH PORTLAND CEMENT GROUT HAVING A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT28 DAYS, AND A MAXIMUM AGGREGATE SIZE OF 3/4". 8. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, EXCEPT WELDED REINFORCEMENT SHALL CONFORM TO ASTM A706, GRADE 60. 9. HORIZONTAL JOINT REINFORCEMENT SHALL BE FACTORY FABRICATED, LADDER TYPE, 9 GAGE WIRE CONFORMING TO ASTM A82, AND PLACED AT 16' ON CENTER (TYPICAL U.NO.). 10. ALL CELLS CONTAINING REINFORCEMENT, BOLTS, OR OTHER METAL ANCHORS SHALL BE GROUTED SOLID. ANY CELLS AT OR BELOW GRADE SHALL BE GROUTED SOLID, WHETHER REINFORCED OR NOT. 11. BOND BEAM REINFORCING SHALL CONTINUE THROUGH CONTROL JOINTS ATALL FLOOR AND ROOF LEVELS AS WELLAS AT ALL LINTEL LOCATIONS. 12. ALL WALLS AND LINTELS SHALL BE TEMPORARILY BRACED/SHORED AS REQUIRED UNTIL CONSTRUCTION IS COMPLETE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING/SHORING. 13. CONTROL JOINTS SHALL NOT BE PLACED ABOVE OR WITHIN 2'-0" OF OPENINGS OR WITHIN A BOND BEAM. NOTIFY THE STRUCTURAL ENGINEER OF ANY CONTROL JOINTS VIOLATING THESE CRITERIA PRIOR TO STARTING WALL CONSTRUCTION. 14. CONTRACTOR SHALL PROVIDE CONTROL JOINTS IN CMU CONSTRUCTION. JOINT SPACING SHALL NOT EXCEED 1.5 TIMES THE WALL HEIGHT (1.5 x H) OR 25 FEET, WHICHEVER IS LESS. PROVIDE A JOINT WITHIN 10 FEET OF ALL WALL CORNERS. COORDINATE ALL JOINT LOCATIONS WITH ARCHITECTURE AND SUBMIT A JOINT LAYOUT PLAN TO ARCHITECT/ENGINEER FOR REVIEW & APPROVAL. 1. WH EN WELDS ARE NOT CALLE D OUT ON THE DRAWINGS, THEY AR E MIN IMU M SIZE CONTINUOUS FILLET WELDS IN ACCORDANCE WITH AWS D1.1. FILLET WELDS NOT SPECIFIED AS TO LENGTH SHALL BE CONTINUOUS. 2. UNLESS NOTED OTHERWISE ON THE DRAWINGS, ALL GROOVE WELD SHALL BE FULL PENETRATION. 3. PROVIDE FILLET WELDS AT ALL CONTACT JOINTS BETWEEN STEEL MEMBERS SUFFICIENT TO DEVELOP THAT ALLOWABLE TENSILE STRENGTH OF THE SMALLER MEMBER AT THE JOINT UNLESS NOTED OTHERWISE ON THE DRAWINGS. 4. WELDING OF METAL FORM DECK SHALL CONFORM TO AWS DI.3. EARTHWORK AND FOUNDATIONS 1. THE FOUNDATION DESIGN IS BASED ON A SUBSURFACE EXPLORATION AND REPORT BY ATC GROUP SERVICES, LLC. (PROJECT NO. 170GCOO754) DATED JANUARY 7, 2019. THE CONTRACTOR SHALL OBTAIN A COPY OF THIS REPORT, AND THE REPORT SHALL BE CONSIDERED APART OF THE CONTRACT DOCUMENTS. 2. A GEOTECHNICAL ENGINEER SHALL VERIFY THAT SOILS OF THE DESIGN BEARING CAPACITY HAVE BEEN ENCOUNTERED AND THAT THE BUILDING PAD IS SUITABLE FOR CONSTRUCTION. 3. THE FOUNDATION DESIGN IS BASED ON POTENTIAL SLAB TOTAL AND DIFFERENTIAL MOVEMENTS OF ONE (1) INCH AND THREE-QUARTERS (3/4) INCH, RESPECTIVELY. THE SLAWFOUNDATION DESIGN IS BASED ON THE •SPREAD FOOTINGS" SECTION OF THE GEOTECHNICAL REPORT. THE CONTRACTOR SHALL PREPARE THE SUBGRADE AS OUTLINED IN THE REPORT/SECTION. 4. CONTINUOUS AND ISOLATED FOOTINGS ARE DESIGNED FORAN ALLOWABLE NET BEARING PRESSURE OF 3,000 PSF. THESE VALUES ARE APPLICABLE FOR FOOTINGS BEARING ON FIRM, NATURAL SOIL ON COMPACTED ENGINEERED FILL AS OUTLINED IN THE GEOTECHNICAL REPORT. ALL EXTERIOR FOOTINGS SHALL BEAR A MINIMUM OF 36 INCHES BELOW FINISH GRADE FOR FORST PROTECTION. 5. A QUALIFIED SOIL TECHNICIAN SHALL PERFORM SUFFICIENT IN -PLACE DENSITY TESTS DURING FILL OPERATIONS TO VERIFY THAT PROPER LEVELS OF COMPACTION ARE ATTAINED AND THAT FOOTINGS ARE BEARING ON THE PROPER MATERIAL. THE CONTRACTOR/OW NER SHALL USE THE SAME GEOTECHNICAL ENGINEER THAT PREPARED THE GEOTECHNICAL REPORT FOR FOUNDATION INSPECTIONS. 6. AFTER THE FOOTINGS HAVE BEEN EXCAVATED AND BEFORE REINFORCING STEEL PLACEMENT, A GEOTECHNICAL ENGINEER SHALL VERIFY SOILS OF THE DESIGN BEARING CAPACITY HAVE BEEN ENCOUNTERED.A WRITTEN REPORT, INCLUDING REMEDIAL ACTION, SHALL BE PROVIDED TO THE STRUCTURAL ENGINEER OF RECORD. 7. CONCRETE FOR SLABS ON FILL SHALL BE PLACED OVERA CONTINUOUS 15 MIL. MOISTURE BARRIER OVER A 4 INCH LAYER OF CLEAN UNIFORM SAND. ALL SEAMS SHALL BE LAPPED 12 INCHES AND TAPED. VAPOR BARRIER SHALL CONFORM TO ASTM E 1745 CLASS A AND ASTM E 96 WITH A PERMEANCE RATING OF 0.01 PERMS OR LOWER. 8. POSITIVE SITE DRAINAGE SHALL BE MAINTAINED TO DIVERT WATER AWAY FROM THE BUILDING AREAS. WEATHER PERIODS WILL PRODUCE PROBLEMS DUE TO SOIL SATURATION. CONSULT THE GEOTECHNICAL ENGINEER REPORT OR GEOTECHNICAL ENGINEER FOR METHODS OF IMPROVING HIGHLY SATURATED SOILS. 9. THE ABOVE REQUIREMENTS ARE A SUMMARY OF THE REQUIREMENTS OF THE GEOTECHNICAL REPORT. CONTRACTOR SHALL NOT BE ABSOLVED FROM THE RESPONSIBILITY OF REVIEWING AND COMPLYING WITH THE ENTIRE GEOTECHNICAL REPORT. SYMBOL LEGEND F1� FOOTING MARK 0 w 99' -0"f TOP OF FOOTING X T/FTG EL- n TOP OF FOOTING / r- LLZQ 9A� PIER CAP ELEVATION I I O < T/CONC EL_ n TOP OF CONCRETE L - > j PIER DIAMETER w w O ELEVATION f PIER BELL DIAMETER w 2 T/STL EL- n TOP OF STEEL pQ 1 ELEVATION �� ` �99'-0�TOP OF PIER w o (BOTTOM OF DECK) I V I \ \ / PIER DIAMETER SECTION 54.0 24 PIER EMBED DEPTH 4"/ 0" 1 99--4r TOP OF PIER ELEVATION \ � 57.0 COL SIZE. REF. PLAN X(SX.X t Z BASE PLATE. REF. SCHEDULE 0 I ENLARGED PLAN J OR PLAN DETAIL STEEL BEAM SIZE / /�NUMBER OF NELSON STUDS � POSITIVE MID SPAN CAMBER �W14x22 (1 SLAB STEP I HIGH/LOW 'J 2) (C=1") IH GH R=18K UN FACTORED SERVICE LOAD REACTION AT EACH END ROOF TOP UNIT FULL PENETRATION REF. PLAN FOR MOMENT WEIGHT CONNECTION STRUCTURAL SHEET INDEX Sheet Number Sheet Name Silo GENERAL NOTES S120 SPECIAL INSPECTIONS S130 DIAGRAMS&ABBREVIATIONS S140 SCHEDULES & TYPICAL DETAILS S200 ISOMETRIC VIEW S210 FOUNDATION PLAN S220 MEZZANINE AND ROOF FRAMING PLAN S230 PARTIAL PLANS S310 TYPICAL FOUNDATION DETAILS S320 FOUNDATION DETAILS S330 FOUNDATION DETAILS S410 TYPICAL FRAMING DETAILS S420 TYPICAL COMPOSITE SLAB DETAILS S430 MEZZANINE DETAILS M itDETAILS S432 FRAMING DETAILS S433 FRAMING DETAILS S440�FRAMING DETAILS HART GAUGLER + ASSOCIATES sremN.n,e sir.. rz rv. c..N�.i sip iaoo wir..aS75zszsa m.zasSto smi 972. r., w..w.x.ftauglel•.am�.wm D�wm DJ DmIGN SWR I HGAJOBN 218232 <n H W LU oe cgs LU zJV W >wU a rr � z Ong q m W LLQ g O t ws z 0 E 2 � z w m 0 sn'U4r �, 1,QEG\SiERFO., _ No.PE108094216 STATE OF XO A r �rrrunlr� 0212fi12019 Seals ISSUE FOR BID & PERMIT co C+) O O V Z J W Q U U Z OL L06 J i [� LU CM O J IWI QiCnQ +-. WP�j LO OD +� Cz LO � = r No Reuisicn Date cr Project Number'. 3018082 Date'. 02/26/2019 Sheet Thle and Number'. silo GENERAL NOTES