HomeMy WebLinkAboutA-101-MECHANICAL-MEZZANINE-FLOOR-PLAN-Rev.0Subject to compliance with all regulations
of State and Local Codes
City of Camel
FLOOR PLAN LEGEND
NEW PARTITION - TYPE A2 U N 0.
STRUCTURAL COLUMN - REFER TO STRUCT.
ELEVATION TAG
/iTION TAG
A4.01
1000 DOOR IDENTIFICATION
REF: SHEET A5.02 FOR DOOR SCHEDULE
�- WALL PARTITION TAG
REF: SHEET A501
pp CARD READER BY OWNER'S SECURITY VENDER
F.E.C. AUTOMATIC OPERATOR PUSH PAD
�F E.
FIRE EXTINGUISHER CABINET
FIRE EXTINGIIISHFR BRACKET MOIINTFn
11 -1 VLnuun_uiu_nuuLenLnuuLn,nu. aM,U,
02 HOUSEKEEPING FAD AT MECH. EQUIPMENT, PER MEP
03 DAVIT CRANE, FLOOR MOUNTED
04 PAINTED STEEL PIPE GUARD RAIL, PAINT TO MATCH DOOR FRAMES
OS DOUBLE FRAME WALL FOR KNOCK -OUT PANEL AS INDICATED.
MEVANINE GUARDRAIL. PER 2&3/A-101
TYP. GUARDRAIL AT MEZZANINE
A-101 SCALE: 11/2"=1'-0"
L11X3X1/4X3CLIP -
BOLTED TO 16 GA. CANT
DOUBLE STUD BEHIND GYP Go.
FLOOR PLAN GENERAL NOTES
1. PARTITION TYPES ARE SHOWN ON A-600. REF: GIGO SERIES FOR ADDITIONAL FIRE RATED
& SMOKE TIGHT WALL LOCATIONSAND ENLARGED PLANS FOR ADDITIONAL PARTITION TAGS.
ALL PARTITIONS ARE TYPE'A3' UNLESS OTHERWISE NOTED.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR OBTAINING CLARIFICATIONS FROM THE ARCHITECT.
3. DIMENSIONS SHOWN ON THE FLOOR PLANS ARE FROM CENTERLINE OF COLUMNS TO FACE
OF FINISH INTERIOR WALLS AND TO INSIDE FACE OF EXTERIOR WALLS UNLESS OTHERWISE
INDICATED OR DETAILED.
4. FOR FURTHER DIMENSIONS, SEE LARGE SCALE PLANS, SECTIONS, ELEVATIONS AND
DETAILS.
6. AT EACH SINK LOCATION PROVIDE & INSTALL (1) PT-1 PAPER TOWER DISPENSER AND (1)
SDI OWNER FURNISHED SOAP DISPENSER UNLESS INDICATED OTHERWISE.
7. PIPING LOCATED ABOVE GRADE AND INSIDE THE BUILDING SHALL BE CONCEALED IN
FURRED SPACES WITH THE EXCEPTION OF PIPING IN STAIRWAYS, EQUIPMENT ROOMS, SHELL
SPACES, AND MEP SUPPORT SPACES. THE CONTRACTOR SHALL COORDINATE WITH OTHER
TRADES TO PROVIDE FURRING FOR PIPING INSTALLED IN FINISHED AREAS.
A. RECESSED ITEMS (GREATER THAN 16 SQ. IN.I IN RATED ANDIOR SMOKE WALLS. INCLUDING
ELEC. PANELS, ELEC. DUCTS, MED GAS VALVE BOXES, FIRE EXT. CABINETS. ETC. SHALL BE
BACKED WITH 518' TYPE'X' GYP. BD. TO MAINTAIN RATING FOR WALL. REF: A6 SERIES FOR
DETAILS.
9. CAULK AT JUNCTURE OF INTERIOR FACES OF DOOR FR)NMES, VIEW WINDOW FRAMES, EXT.
WINDOW FRAMES, CABINET WORK AND CASEWORK WITH ADJACENT MATERIALS EVEN
THOUGH JOINT MAY NOT BE VISIBLE.
10. PROVIDE ONE JA-1 MOPIBROOM HOLDER AT EACH JAN ITOR5 CLOSET WITH FRP
SURROUND AT UTILITY SINK . REFER TO AS SERIES FOR DETAIL OF ERE.
11. APPLY CEMENTITIOUS SPRAYED ON FIRE PROOFING ON ALL STRUCTURAL MEMBERS AS
SPECIFIED TO MEET REQUIRED FIRE RATINGS.
12. ALL OPENINGS IN SMOKE RATED ENCLOSURES TO BE SEALED TO RESIST THE PASSAGE
OF SMOKE PER SECTION 710.5 AND 710.7
a.
MEZZANINE LADDER DETAIL
A-101 SCALE: 3/4"=1tom
1 114" LD, STD METAL
PIPE GUARDRAIL
12" DIAMETER INTERMEDIATE
PICKETS AT 4" O.C. MAX
SPACING
EDGE ANGLE, REF STRUCTURAL
STEEL BEAM, REF STRUCTURAL
f RE: PLAIN RE: PLAN
STAIR STRINGER AND RAILING
A-101 SCALE: 3/4" = 1'-0"
ELD CLIP ANGLES
TO EDGE ANGLES
3/4"DIA STL. RU
@ r-G" Q.C.
(DRILL CHANNEL
C 3 X 5 CONT.
H W
z
E
Z <LLJ
0wI.-
e
J
>wU
g
Z �
m
w009
Q
0
O
w
t
i
iffi
z
n
g
E
m
0
/
Z
0
W
0
m
�
Seals
ISSUED FOR BID &
PERMIT
C
O
O
U
co
I_—
O
CD
O)
co
V
OLDZ
C
J
ul
LrJ
06
cc
Q
CD
U
s—
G-
U
�
a�
c
EL
j
CCU
Cll
>
OLD
ZD
�
J
call
NJ
call
Q
2
H�
�
2
LO
m
A)
r
No
Redden
Date
Project Number 3018082
Date 0226/2019
Sheet Title and Number
A-101
MECHANICAL MEZZANINE
FLOOR PLAN
DATE: 06/07/19