Loading...
HomeMy WebLinkAboutA121 Reflected Ceiling PlanLEGEND NEW OR RELOCATED EXISTING TO REMAIN IN 01 LIGHT FIXTURE, 2'x4', LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC FLUORESCENT, PARABOLIC ❑LIGHT FIXTURE, 2'x2', LIGHT FIXTURE, 2'x2', FLUORESCENT, PARABOLIC FLUORESCENT, PARABOLIC RECESSED LIGHT jX RECESSED LIGHT FIXTURE FIXTURE DIRECTIONAL RECESSED LIGHT FIXTURE WALL SCONCE LIGHT WALL SCONCE LIGHT FIXTURE FIXTURE ®LIGHT FIXTURE, ® LIGHT FIXTURE, PENDANT PENDANT ® EXIT LIGHT FIXTURE ® EXIT LIGHT FIXTURE EMERGENCY LIGHT EMERGENCY UGHT FIXTURE FIXTURE $N LIGHTSWITCH $ LIGHTSWITCH $N3 LIGHT SWITCH, 3-WAY $3 LIGHT SWITCH, 3-WAY $ND LIGHT SWITCH, DIMMER $D LIGHT SWITCH, DIMMER $NP SWITCH, PROJECTOR SCREEN $P SWITCH, PROJECTOR SCREEN $NG SWITCH, GARBAGE DISPOSAL $G SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) $NE SWITCH, EXHAUST FAN $G SWITCH, EXHAUST FAN i — LIGHTCIRCUIT - LIGHTCIRCUIT CEILING GPoD, CEILING GPoD, SUSPENDED, 2a2' _ __�__r_ SUSPENDED, 2a2' GYPSUM BOARD GYPSUM BOARD CEILING CEILING RELOCATED DIFFUSER, LAYJN, 2'X2' ❑ DIFFUSER LAYJN, TX7 El RELOCATED EXISTING DIFFUSER, LAYJN, Px4' ® DIFFUSER, LAY IN, Px4' RELOCATED EXISTING DIFFUSER, LAY-N. ® DIFFUSER, LAY -IN, 4'k4' ® 4"x4' ® EXHAUST FAN, 2'{' EXISTING EXHAUST FAN, TX7 NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City Bf Catmel DATE: 06/17/19 RELOCATE DIFFUSERS & MECHANICAL DIFFUSER RELOCATION nTaT 'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION GENERAL NOTES REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 9'LWA.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION, FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. UNLESS NOTED OTHERWISE. THE LIGHTS SHOWN AS 'NEW OR RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LESS THAN 50%OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING, LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI, 5. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. MECHANICAL NOTES PLAN NOTES I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED, ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT, NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. PROVIDE (2) PENDANTS CENTERED EQUALLY OVER ISLAND. RV1 PROVIDE SEPARATE SWITCH. ASSUME ALLOWANCE OF$800 EACH MATERIAL COST. RD2 NOT USED, OR03RELOCATE SALVAGED PROJECTOR SCREEN PROJECTORS AND COORDINATING EQUIPMENT. CONFIRM EXACT LOCATION WITH TENANT AND TENANTS FURNITURE VENDOR. PROVIDE SWITCHES AS REQUIRED FOR AUTOMATIC SCREEN CONTROL. ® AREA NOT IN CONTRACT REFLECTED CEILING PLAN N ❑ AREA OF WORK 0 4' 8' 16' THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 D51GN. Z O � Woa0 Q W `Z` i% = Q Q T1 0 Z i p O Lu t/7 OO LL1 Y = Zap pw CL 0 O NO ISSUE DATE DESCRIPTION 03.04.19 REVIEW SET 03.13.19 CHECKSET 03.19.19 ND SET 04.24.19 CONSTRUCTION SET EVISIONS ARK DATE DB DESC NPTION PROJECT NUMBER 2019.049 I'llMGR DRAWN BY SD� 4TH FLOOR REFLECTED CEILING PLAN Al21