Loading...
HomeMy WebLinkAboutE111 Electrical PlanLEGEND NEW CONSTRUCTION EXISTING TO REMAIN Do POWER OUTLET, DUPLEX 4 POWER OUTLET, QUADRUPLEX ® JUNCTION BOX MOUNTED OCEILING JUNCTION BOX ® BOX, BLANK COVER PLATE ® BOX, OPEN P PROVIDE JUNCTION BOX 6 ABOVE CEILING FOR POWER POLE CONNECTION, POWER POLE BY OTHERS. FLOOR BOX WITH POWER 70=19 AND DATA, FLUSH MOUNTED FLOOR BOX WITH ®4 JUNCTION BOX AND DATA, FLUSH MOUNTED DATA/COMMUNICATION I OUTLET (PROVIDE BOX AND PULL STRING ONLY) DIED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42" HEIGHT OF ELECTRICAL OR DATA DEVICE POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX Q JUNCTION BOX O CEILING MOUNTED JUNCTION BOX Q BOX, BLANK COVER PLATE Q BOX, OPEN PO POWER AND DATA POLE FLOOR BOX WITH POWER Fq AND DATA, FLUSH MOUNTED FLOOR BOX WITH FGJ q JUNCTION BOX AND DATA, FLUSH MOUNTED b DATA/COMMUNICATION OUTLET RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel DATE: 06/17/19 AREA NOT IN CONTRACT ❑ AREA OF WORK GENERAL NOTES I. TENANTS FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS, ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 5. CONTRACTOR TO COORDINATE WITH TENANT'S FURNITURE VENDOR ON ANY ELECTRICAL AND DATA NEEDS FOR NEW OR RELOCATED WORKSTATIONS. PLAN NOTES LUl PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR, SEE DOOR SCHEDULE FOR MORE DETAILS. E02 COORDINATE WITH TENANT'SA/V VENDOR ON ANY UPDATED REQUIRED IN THIS ROOM, DESIGN INTENT IS FOR ALL EQUIPMENT INCLUDING, BUT NOT LIMITED TO SPEAKERS, PROJECTORS, DROP DOWN SCREEN, AND CONTROL SYSTEMS TO BE IN FULL WORKING ORDER. ANY UNUSED EQUIPMENT TO BE REMOVED. ED} EXISTING JUNCTION BOX AND DATA FOR TENANTS FURNITURE SYSTEM TO REMAIN, CONFIRM IF EXISTING LOCATION WORKS WITH TENANTS NEW LAYOUT. CONFIRM WITH TENANT'S FURNITURE VENDOR, E04 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO WALL CABINET/ BASE CABINET FOR TENANTS MICROWAVE, CENTERED AT 60"A.F.F. AND 24"A.F.F. E05 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. E06 PROVIDE POWER AS REQUIRED FOR TENANT PROVIDE SCOTSMAN ICE MACHINE, EO] PROVIDE POWER FOR TRAINING ROOM PROJECTOR AND PROJECTOR SCREEN. COORDINATE WITH TENANT AND TENANT'S I.T VENDOR, E06 PROVIDE(1) DOUG MOCKER PCD85B/3E(OR EQUAL) RECESSED ELECTRICAL OUTLET ON EACH VERTICAL END OF ISLAND (2 TOTAL). COLOR TO BE GRAY, PROVIDE SPEC SHEET TO TENANT FOR APPROVAL. E09 NOT USED. E10 EXISTING POWER TO REMAIN UNLESS OTHERWISE NOTED. CONFIRM WITH TENANT AND TENANT'S IT VENDOR ON ANY E11 ADJUSTMENTS IN POWER REQUIRED IN SERVER ROOM PER NEW LAYOUT. CLCI.I KILT rLAN 0 4' 8' 16' THIS DRAWING, AND THE IDEAS, IESIGNS AND CONCEPTS CONTAINED HWBN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART. WITHOUT THE WRITTEN CONSENT OF SCHOTT DEIGN. V I V) O Woo - 411i I �E111