HomeMy WebLinkAboutE111 Electrical PlanLEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
Do
POWER OUTLET, DUPLEX
4
POWER OUTLET,
QUADRUPLEX
®
JUNCTION BOX
MOUNTED
OCEILING
JUNCTION BOX
®
BOX, BLANK COVER PLATE
®
BOX, OPEN
P
PROVIDE JUNCTION BOX
6
ABOVE CEILING FOR
POWER POLE
CONNECTION, POWER
POLE BY OTHERS.
FLOOR BOX WITH POWER
70=19
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
®4
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
I
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DIED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42"
HEIGHT OF ELECTRICAL
OR DATA DEVICE
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
Q
JUNCTION BOX
O
CEILING MOUNTED
JUNCTION BOX
Q
BOX, BLANK COVER PLATE
Q
BOX, OPEN
PO
POWER AND DATA POLE
FLOOR BOX WITH POWER
Fq
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
FGJ q
JUNCTION BOX AND
DATA, FLUSH MOUNTED
b DATA/COMMUNICATION
OUTLET
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel
DATE: 06/17/19
AREA NOT IN CONTRACT
❑ AREA OF WORK
GENERAL NOTES
I. TENANTS FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS, ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
5. CONTRACTOR TO COORDINATE WITH TENANT'S FURNITURE
VENDOR ON ANY ELECTRICAL AND DATA NEEDS FOR NEW OR
RELOCATED WORKSTATIONS.
PLAN NOTES
LUl PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR
FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANT'S SECURITY CONTRACTOR, SEE DOOR SCHEDULE
FOR MORE DETAILS.
E02 COORDINATE WITH TENANT'SA/V VENDOR ON ANY UPDATED
REQUIRED IN THIS ROOM, DESIGN INTENT IS FOR ALL EQUIPMENT
INCLUDING, BUT NOT LIMITED TO SPEAKERS, PROJECTORS, DROP
DOWN SCREEN, AND CONTROL SYSTEMS TO BE IN FULL WORKING
ORDER. ANY UNUSED EQUIPMENT TO BE REMOVED.
ED} EXISTING JUNCTION BOX AND DATA FOR TENANTS FURNITURE
SYSTEM TO REMAIN, CONFIRM IF EXISTING LOCATION WORKS
WITH TENANTS NEW LAYOUT. CONFIRM WITH TENANT'S FURNITURE
VENDOR,
E04 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO WALL CABINET/ BASE CABINET FOR TENANTS MICROWAVE,
CENTERED AT 60"A.F.F. AND 24"A.F.F.
E05 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT.
E06 PROVIDE POWER AS REQUIRED FOR TENANT PROVIDE SCOTSMAN
ICE MACHINE,
EO] PROVIDE POWER FOR TRAINING ROOM PROJECTOR AND
PROJECTOR SCREEN. COORDINATE WITH TENANT AND TENANT'S
I.T VENDOR,
E06 PROVIDE(1) DOUG MOCKER PCD85B/3E(OR EQUAL) RECESSED
ELECTRICAL OUTLET ON EACH VERTICAL END OF ISLAND (2
TOTAL). COLOR TO BE GRAY, PROVIDE SPEC SHEET TO TENANT
FOR APPROVAL.
E09 NOT USED.
E10 EXISTING POWER TO REMAIN UNLESS OTHERWISE NOTED.
CONFIRM WITH TENANT AND TENANT'S IT VENDOR ON ANY
E11 ADJUSTMENTS IN POWER REQUIRED IN SERVER ROOM PER NEW
LAYOUT.
CLCI.I KILT rLAN
0 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
IESIGNS AND CONCEPTS CONTAINED
HWBN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
ISED OR REPRODUCED IN WHOLE, OR
IN PART. WITHOUT THE WRITTEN
CONSENT OF SCHOTT DEIGN.
V I
V)
O
Woo
- 411i
I
�E111