HomeMy WebLinkAboutA111 ArchitecturalARCHITECTURAL LEGEND
NEW CONSTRUCTION
WALL
WT
PARTIAL HEIGHT WALL
®
�u
WINDOW/SIDELIGHT
DOOR AND FRAME N�
(SEE DOOR SCHEDULE)
EXISTING TO REMAIN
WALL
® PARTIAL HEIGHT WALL
> WINDOW/SIDELIGHT
7 DOOR AND FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS,
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE WIIUNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM Al SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
Wl WALL WITH INSULATION -
3% METAL STUDS AT 16" O.C.;
ONE LAYER OF 5/g'TYPI GYPSUM BOARD ..:...>..:.:. „::....,,
EACH SIDE:
EXTEND WALLTO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND T-O' EACH SIDE OF WALL ABOVE
CEILING
PARTIAL HEIGHT WALL - -
3% MEAL STUDS AT 16"O.C.;
ONE LAYER OF % TYPE "X" GYPSUM BOARD
EACH SIDE;
SEE DETAIL 3/A211 FOR MORE INFO
PROVIDE 1"STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED;
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Calmed
DATE: 06/17/19
GENERAL NOTES PLAN NOTES
I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. AJI ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING
WALLS.
2. REFER TO FINISH PUN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL DRYWALL A02 NEW SEMI RECESSED FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. NFPA 10.
A03 PROVIDE NEW ALL GLASS WINDOW SYSTEM AND DOOR. SEE DOOR TYPE D4 FOR MORE INFORMATION. NEW GLASS SYSTEM TO INCLUDE NEW CUSTOM
VINYL FILM. ASSUME 50%COVERAGE AND (2) COLORS. FINAL DESIGN TBD. COORDINATE WITH TENANT AND SDI.
E4 EXISTING SEMI RECESSED FIRE EXTINGUISHER TO REMAIN.
A05 NOT USED.
A06 PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT.
A0� PROVIDE NEW PARTIAL HEIGHT WALL AND 3'-6" DEEP x 12'-0" LONG COUNTERTOP. SUPPORT COUNTER AS REQUIRED WITH CENTERLINE BRACKET'S FRONT
MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRY WALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK
CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL
INSTALLATION AS NEEDED. SEE DETAIL 3 ON SHEET A211 FOR MORE INFORMATION.
A08 PROVIDE SEPARATE PRICE FOR NEW CUSTOM VINYL FILM. DESIGN INTENT IS FOR 75%COVERAGE. ASSUME 3 DIFFERENT COLORS. FINAL DESIGN TBD.
COORDINATE AS REQUIRED WITH SDI AND TENANT.
A09 CONTRACTOR TO LEAVE 5'-0" CLEAR PATHWAY BETWEEN EXISTING WORKSTATIONS AND NEW WALL CONSTRUCTION. CONFIRM NEW WALL LOCATION WITH
TENANT.
9 NOT USED.
9 PROVIDE ADDITIONAL BLOCKING AS REQUIRED FOR TENANT PROVIDED WHITE BOARD. CONFIRM LOCATOR! WITH TENANT.
9 PROVIDE SEPARATE PRICE FOR NEW AUTOMATIC ROLLER SHADES IN THIS LOCATION. DESIGN INTENT IS FOR EXISTING BUILDING STANDARD BLINDS TO
REMIAIN INTACT. ROLLER SHADES TOM INSTALLED ON INTERIOR OF EXISTING BLINDS. PROVIDE CUT SHEEFSTO TENANT FOR APPROVAL.
ppi PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PlPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING.
P02 PROVIDE WATER LINE FOR COFFEE AND ICE MACHINE. CONFIRM LOCATION WITH TENANT. CONFIRM IF ICE MAKER REQUIRES DRAIN.
AREA NOT IN CONTRACT ARCHITECTURAL PLAN "
0 4' B' 16'
❑ AREA OF WORK �
THIS DRAWING, AND THE IDEAS,
IESIG NS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
ISED OR REPRODUCED IN WHOLE, OR
IN PAWL WITHOUTTHE WRITTEN
CONSENT OF SCHOTT DESIGN.
VA
N
V-)
Woo
Z
qi
CL
Q
W
H
~
Z
Q
Q
N
Q
�O
Z
0
I-
HOril
Y
=
Z
a
NO
Ow
CL
ON,
O
O
ISSUE
DATE
DESCRIPTION
03.04.19
REVIEW SET
03.13.19
CHECKSET
03.19.19
BID SET
04.24.19
CONSTRUCTION SET
EVISIONS
ARK
DATE
DB
DESCRIPTION
iiiiiiiim
PROJECT NUMBER
2019.049
PROD. MGR DRAWN BY
SDH JJ
4TH FLOOR
ARCHITECTURAL
FLOOR PLAN
A111