HomeMy WebLinkAboutA121 Electrical Plan & Reflective Ceiling PlanELECTRICAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET, DUPLEX
POWER OUTLET, DUPLEX
.N,
^N'
POWER OUTLET,
POWER OUTLET,
QUADRUPLEX
QUADRUPLEX
J
JUNCTION BOX
J
JUNCTION BOX
OCEILING
MOUNTED
CEILING MOUNTED
JUNCTION BOX
JUNCTION BOX
®
BOX, BLANK COVER PLATE
®
BOX, BLANK COVER PLATE
BOX, OPEN
QO
BOX, OPEN
P
PROVIDE JUNCTION BOX
P
POWER AND DATA POLE
D
ABOVE CEILING FOR
O
POWER POLE
CONNECTION, POWER
POLE BY OTHERS.
FLOOR BOX WITH POWER
FLOOR BOX WITH POWER
F6I®
AND DATA, FLUSH
5z11
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
®
JUNCTION BOX AND
J 14
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
DATA/COMMUNICATION
14
OUTLET (PROVIDE BOX
b
AND PULL STRING ONLY)
OUTLET
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42"
HEIGHT OF ELECTRICAL
OR DATA DEVICE
WELCOME
o E04 I 10
r---i
1 1 CONFERENCE
��rrSS NFEREN"P �b
LJI . ICD
CI Ia
oe
® AREA NOT IN CONTRACT
❑ AREA OF WORK
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Camel
DATE: 06/19/19
GENERAL ELEC. NOTES
ME
I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
FURNITUREAND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. E01 DEDICATED RECEPTACLEAS REQUIRED.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF E02 PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL SYSTEM, WHERE JUNCTION BOX AND DATA ARE LOCATED AT
NEW DEVICES AND FACE PLATES TO BE WHITE; REPLACE EXISTING WINDOW LINE, ENSURE LOCATION IS POSSIBLE PER EXTERIOR
AS REQUIRED. WINDOWS. IF NOT POSSIBLE, MOVE JUNCTION BOX AND DATATO
CLOSEST LOCATION POSSIBLE. COORDINATE EXACT LOCATION
3. REFER TO DOORSCHEDULEAND COORDINATE WITH WITH TENANT'S FURNITURE VENDOR,
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
MAG-LOCKS. CARD READERS ARETVPICALLV INSTALLED BVTHE EO} INTO CABINET/WALL FORTENANT'S MICROWAVE, CENTERED AT
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BYSDI. 60" A.F.F.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS O PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED E04 TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES LOCATION WITH TENANT,
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL O CONFIRM FINAL ELECTRICAL REQUIREMENTS AND LOCATIONS
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL E05 WITH TENANT IN THIS ROOM.
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES. PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR
E06 FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANTS SECURITY CONTRACTOR. SEE DOOR SCHEDULE
FOR MORE DETAILS,
E07 COORDINATE ELECTRICAL REQUIREMENTS AND LOCATION WITH
TENANT'S UNDER COUNTER FRIDGE.
E08 PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THIRD DEVICE
FOR ELECTRICAL AND DATA. COORDINATE WITH TENANT'S
FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THIRD
DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO
ORDERING,
5'-6"x5'-6" 5'-6"x5'-6",I E02 5'-6"x5'-6" E06
ELECTRICAL PLAN NOTES
-0+60" OFFICE
B1+60 rm
OFFICE
OFFICE OFFICE
Iv
5'-6"X5'-6" II 5'-6"x5'-6":1 II 5'-6'k5'-6"
5'-6"X5'-6" II 5'-6'55'-6":1 I: 5'-6'k5'-6"
OPEN OFFICE FOCUS
® 112
o7C = u ¢r
II I10 13LJI
L r 6x6 11
--�i
II E02 1 11
Ef JI
x6L II
OFFICE
IFTETI
ELECTRICAL PLAN
0 2' 4' 8' 16'
■
RCP LEGEND
ME
NEW
OR RELOCATED
EXISTING TO REMAIN
I
LIG- HT FIXTURE, x4', LED,
LIGHT FIXTURE, 2>4 ,
-
MEIA U24CZ2
FLUORESCENT, PARABOLIC
LIGHT FIXTURE, 2'x2', LED,
LIGHT FIXTURE, 2'x2',
METALUX 22CZ
FLUORESCENT. PARABOLIC
TX
RECESSED LIGHT
):{
RECESSED LIGHT
FIXTURE, LED
FIXTURE
LIGHTFIXTURE,
®
LIGHTFIXTURE,
PENDANT
PENDANT
NIL
NIGHT LIGHT
e
EXIT NIGHT FIXTURE
®
EXIT NIGHT FIXTURE
EMEdGEJCYLIGHT
®
EMERGENCY NIGHT nXTURE
FIXTURE
UGHTSWITCH
$
UGHTSWITCH
+N3
UGHT SWITCH, SWAY
$3
UGHT SWITCH, SWAY
$NO
UGHT SWITCH, DIMMER
$D
UGHT SWITCH, DIMMER
$NG
SWITCH, GARBAGE DISPOSAL
$G
SWITCH, GARBAGE DISPOSAL
(ABOVE COUNTERTOP)
i —
NIGHT CIRCUIT
NIGHT CIRCUIT
RSIRONG
24 X2EIIMREVEAL
IFLOU °/la"
__IT__
_
CEILING GRID,
yTl--illT--IIT�
SUSPENDED CEILING GRID
r_
SUSPENDED, 2'x2'
WITH ARMSiRONG
GEORGIAN #1753B
TEGULAR BEVELED EDGE 24'
X 2aE X W',
GYPSUM BOARD
El
COPING
® EXHAUST FAN, 2 x2A] EXISTING EXHAUST FAN, 2'x2'
NO NEW HVAC DUCTWORK S TO BE INSTALLED PER THIS SHEET.
GENERAL RCP NOTES
I. PROVIDE NEW CEILING GRID AND TILE THROUGHOUT; SEE LEGEND
FOR EXACT SPEC. GRID TO BEAT9-0 AFF AS ALLOWABLE PER HVAC
EQUIPMENT AND STRUCTURAL BUILDING ELEMENTS.
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
FIRMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY, IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION, FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS ATTHEIR EXPENSE.
3. LAVOUTSHOWNIS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION, IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI.
4. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE
OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH
ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON
OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT
OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS
DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN
OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS
(COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF
REQUIRED BY CODE.
5. NEW DEVICES AND FACE PLATES TO BE WHITE; REPLACE EXISTING AS
REQUIRED, WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO
ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN
ADJACENT ON PLAN.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUI DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES,
RCP PLAN NOTES
R01 CONTROL WELCOME 101, COFFEE 104, SOCIAL HUB 109, OPEN
OFFICE I10 & CORRIDOR LIGHTING WITH 3-WAY SWITCH AT THIS
LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
R02 PROVIDE NEW BUILDING STANDARD CEILING GRID AND TILE AS
REQUIRED IN COMMON CORRIDOR PER NEW WALL LAYOUT. NEW
CORRIDOR CEILING GRID: 24" X 24" USG FINELINE DXF 9/f6
SUSPENDED GRID WITH USG HACYON CIMAPLUS #98225 SL EDGE
24"X24"XI"CEILING TILES. PROVIDE BUILDING STANDARD LIGHT
FIXTURES. DESIGN INTENT IS FOR CEILING GRID AND LIGHTI FIG TO
MATCH LAYOUT OF EXISTING CORRIDOR ON NORTH END OF
BUILDING. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS.
COORDINATE ALL REQUIREMENTS AND SWITCHING WITH
PROPERTY MANAGEMENT.
RO} PROVIDE NEW DRYWALL BULKHEAD WHERE NEW CEILING GRID
AND TILE DIE INTO EXTERIOR WINDOW LINE. DESIGN INTENT IS FOR
BULKHEAD LOCATION, WIDTH AND HEIGHT ALL TO MATCH SAME
DETAIL IN ATAPCO'S EXISTING SUITE, COORDINATE WITH
LANDLORD FOR EXACT REQUIREMENTS. ENTIRE DRYWALL
BULKHEAD TO BE PAINTED PT1. ON WEST SIDE OF BULKHEAD,
CEILING TO RECEIVE SUITE STANDARD CEILING GRID AT MAXIMUM
HEIGHT ALLOWABLE.
PROVIDE EXHAUST FAN AND SEPARATE SWITCH IN
R04 STORAGE/SERVER 108 AS SHOWN.
® AREA NOT IN CONTRACT REFLECTED CEILING PLAN
❑ AREA OF WORK 0 2' 4' 8' 16' IN
THIS DRAWING. AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
CL O
r
0 W
~
0 W
W > get
J z
5 � J
LJ W
NV��
ZUU
Q
Z_qq
�
Li
DATE DESCRIPTION
04.10.19 REVIEWSET
04.15.19 PERMITSET
REVISIONS
MAR DATE D11DESCRIPTIONiiiiim
No.
AR10700017
STATE OF
PROJECT NUMBER
2019.012
PRIMGR DRAWN BY
EH EH/SLF
1ST FLOOR
ELECTRICAL PLAN/
REFLECTED
CEILING PLAN
A121