HomeMy WebLinkAboutL100 Life Safety Plan2
3
4
5
6
7
13
14
15
16
CODE SUMMARY
SCOPE OF WORK
OFFICE BUILD -OUT OF SHELL SPACE
PREVIOUS USE OF SPACE
N/A
OCCUPANCY CLASSIFICATION
B(USINESS)
CHANGE OF OCCUPANCY CUI%SS?
NO
TOTAL BUILDING AREA
58.182 SF/FLOOR
X
I I STORIES
58.182 SF
TOTAL PROJECT AREA
4,110 SF
SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD
OCCUPANCY CALCULATIONS
NUMBER OF EXITS
GEN. OFFICE
4,110 SF
too
42
TOTAL OCCUPANTS IN PROJECT AREA 42
REQUIRED I PROVIDED 2
SPRINKLER SYSTEM YES/NO)
YES- EXISTINGTO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
58,182 SF
ACCESSORYAREA EXCEEDS 10%
NO
FIRE WALLS, ARI OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
ASTRAE 90.1 SUMMARY
REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978?
NO
BUILDING CONSTRUCTION TYPE
i
GENERAL NOTES
U. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS
REQUIRED TO MEET ALL LOCAL AND STATE CODES.
LIFE SAFETY NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEVA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING IF RE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFFA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUI ED
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regull
of State and Local Codes
City GF Carvind
DATE: 06/19/19
LEGEND
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT
FIRE EXTINGUISHER
EXITSIGN -LED EDGE LIT
EMERGENCYLIGHT
— — —
TRAVEL DISTANCE
AREA NOT IN CONTRACT
AREA OF WORK
COO
F
115 6 E 6
COFFEE
7T STG ISERVER mm OFFICE OFFICE
WELRME F + I
m 9 14G 9 �49
31�2'10 0 8 9 y 5,SF5 6
t CSOCE' I � � c mm mm
F + I
115 ee6 156�6 1 11 6�F5 6
F� 1E L - II - J L = J tot
I OPEN OFFICE FOCUS
/C 0 OATS
7 7x� 4
CONFERENCE 11113
7771
49,6Z
C41
OFFICE OFFICE A'O
Cl to
'4.�G T_
'at- G
gg �l it I� -I I
7 IFI64
MLAKki LIM bArtl Y rLAN
0 4' W 16,
166,
IF
DE IN
SEPARATE PROJECT SCOPE
FULL BUILDING PLAN
NOT TO SCALE
0 pr -1
AA
WN
0
0
0
0�0
SENOR
Z � RE
0
Qc��
�0 C
THUS DRAWING, AND THE IDEAS.
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ME THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DES] GNr IN C.r AND ARE N0770 BE
USED OR REPRODUCED IN WHOLEr OR
IN PARTr WITHOUT THE WRIFFEN
CONSENT OF SCH07 DESIGN.
III
LU
0
im 0 LU
LU
7
SENSORS J LEE
LU
LU U :* 2
V) ce�
z <
U U
3:
Z L0
LL. %o
RRRRRRR
ISSUE
DATE DESCRIPTION
04.10.19 REVIEWSET
04.15.1? PERINUTSET
EVISIONS
AR DATE I DB rMESCRUPTION
IN 0.
AR10700017
STATE OF
PROJECT NUMBER
2019.012
OJ. MGR DRAWN BY
EH EH/SLF
I ST FLOOR
LIFE SAFETY
Ll 00