HomeMy WebLinkAboutL100 Life Safety Plan2 3 4 5 6 7 13 14 15 16 CODE SUMMARY SCOPE OF WORK OFFICE BUILD -OUT OF SHELL SPACE PREVIOUS USE OF SPACE N/A OCCUPANCY CLASSIFICATION B(USINESS) CHANGE OF OCCUPANCY CUI%SS? NO TOTAL BUILDING AREA 58.182 SF/FLOOR X I I STORIES 58.182 SF TOTAL PROJECT AREA 4,110 SF SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD OCCUPANCY CALCULATIONS NUMBER OF EXITS GEN. OFFICE 4,110 SF too 42 TOTAL OCCUPANTS IN PROJECT AREA 42 REQUIRED I PROVIDED 2 SPRINKLER SYSTEM YES/NO) YES- EXISTINGTO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 58,182 SF ACCESSORYAREA EXCEEDS 10% NO FIRE WALLS, ARI OCCUPANCY SEPARATIONS (IF REQUIRED) N/A ASTRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO BUILDING CONSTRUCTION TYPE i GENERAL NOTES U. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEVA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING IF RE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFFA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUI ED SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. RELEASED FOR CONSTRUCTION Subject to compliance with all regull of State and Local Codes City GF Carvind DATE: 06/19/19 LEGEND EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT FIRE EXTINGUISHER EXITSIGN -LED EDGE LIT EMERGENCYLIGHT — — — TRAVEL DISTANCE AREA NOT IN CONTRACT AREA OF WORK COO F 115 6 E 6 COFFEE ­7T STG ISERVER mm OFFICE OFFICE WELRME F + I m 9 14G 9 �49 31�2'10 0 8 9 y 5,SF5 6 t CSOCE' I � � c mm mm F + I 115 ee6 156�6 1 11 6�F5 6 F­� 1E L - II - J L = J tot I OPEN OFFICE FOCUS /C 0 OATS 7 7x� 4 CONFERENCE 11113 ­7771 49,6Z C41 OFFICE OFFICE A'O Cl to '4.�G T_ 'at- G gg �l it I� -I I 7 IFI64 MLAKki LIM bArtl Y rLAN 0 4' W 16, 166, IF DE IN SEPARATE PROJECT SCOPE FULL BUILDING PLAN NOT TO SCALE 0 pr -1 AA WN 0 0 0 0�0 SENOR Z � RE 0 Qc�� �0 C THUS DRAWING, AND THE IDEAS. DESIGNS AND CONCEPTS CONTAINED HEREIN, ME THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DES] GNr IN C.r AND ARE N0770 BE USED OR REPRODUCED IN WHOLEr OR IN PARTr WITHOUT THE WRIFFEN CONSENT OF SCH07 DESIGN. III LU 0 im 0 LU LU 7 SENSORS J LEE LU LU U :* 2 V) ce� z < U U 3: Z L0 LL. %o RRRRRRR ISSUE DATE DESCRIPTION 04.10.19 REVIEWSET 04.15.1? PERINUTSET EVISIONS AR DATE I DB rMESCRUPTION IN 0. AR10700017 STATE OF PROJECT NUMBER 2019.012 OJ. MGR DRAWN BY EH EH/SLF I ST FLOOR LIFE SAFETY Ll 00