HomeMy WebLinkAboutA010.0-A101 FLOOR PLANFIRE DEPARTMENT NOTES 1. ADDRESS NUMBERS: APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION SHALL BE PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET, ROAD, ALLEY, AND WALKWAYS GIVING ACCESS TO AND WITHIN THE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC NUMERALS OR ALPHABET LETTERS. NUMBERS SHALL BE A MINIMUM OF SIX (6) INCHES (152 MM) HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCH (12.7 MM) AND SHALL BE ILLUMINATED IN AN APPROVED MANNER (IF NUMBERS ARE ON THE EXTERIOR). NUMBER HEIGHT AND STROKE WIDTH SHALL BE INCREASED AS NEEDED FOR LEGIBILITY BASED ON VISIBILITY DISTANCE. 2. KNOX BOX: MOUNTING HEIGHT FOR THE KNOX BOX AND/OR KEY SWITCH SHALL NOT EXCEED SIX (6) FEET ABOVE THE GROUND LEVEL/ FINISHED FLOOR. PROVIDE THREE (3) SETS OF KEYS (WITH PERMANENT ENGRAVED IDENTIFICATION) FOR ALL EXTERIOR DOORS, GATES, FIRE ALARM PANEL, AND OTHERS AS DIRECTED BY THE FIRE INSPECTOR. 3. FIRE EXTINGUISHERS: PROVIDE AFIRE EXTINGUISHER (MINIMUM 2A-10BC) WITHIN A RECESSED OR SEMI -RECESSED CABINET WITHIN 75 FEET TRAVEL DISTANCE FROM ALL POINTS IN THE OCCUPANCY; THE EXTINGUISHER SHALL BE MOUNTED ON A HOOK WITHIN THE CABINET (ELEVATED OFF CABINET FLOOR); THE TOP OF THE EXTINGUISHER SHALL BE NO HIGHER THAN 48 INCHES (1219 MM) ABOVE THE FLOOR; EXTINGUISHER SHALL BE PLACED IN A EASILY ACCESSIBLE LOCATIONS WHERE THEY WILL BE READILY ACCESSIBLE AND IMMEDIATELY AVAILABLE FOR USE. 4. FIRE SPRINKLERS: EXISTINGSYSTEM: FOR TENANT IMPROVEMENT PROJECTS,EXTEND/MODIFY THE EXISTING BUILDING'S AUTOMATIC FIRE SPRINKLER SYSTEM TO PROVIDE COMPLETE SPRINKLER PROTECTION THROUGHOUT THE ADDITION OR REMODELED AREA OF WORK. ALTERATIONS TO THE FIRE SPRINKLER SYSTEM SHALL BE APPROVED UNDER SEPARATE PERMIT. PLANS AND PERMIT APPLICATION SHALL BE SUBMITTED WITHIN 30 DAYS OF ISSUANCE OF THE BUILDING PERMIT. NEWSYSTEM: A COMPLETE AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE INSTALLED THROUGHOUT THE STRUCTURE IN ACCORDANCE WITH THE RECOMMENDATIONS OF NFPA 13 AND THE REQUIREMENTS OF THE GLENDALE FIRE DEPARTMENT. PLANS AND PERMIT APPLICATION SHALL BE SUBMITTED WITHIN 30 DAYS OF ISSUANCE OF THE BUILDING PERMIT. RISER AND ALL SPRINKLER PIPING SHALL BE CONCEALED; NO EXPOSED PIPING ON EXTERIOR PERMITTED. QUICK RESPONSE SPRINKLER HEADS ARE REQUIRED THROUGHOUT THE STRUCTURE UNLESS CONTRA -INDICATED. FLAT CONCEALED SPRINKLER HEADS ARE REQUIRED IN ALL HABITABLE AREAS. 5. FIRE ALARM: EXISTINGSYSTEMS: EXTEND/MODIFY THE EXISTING BUILDING'S FIRE ALARM SYSTEM TO PROVIDE COMPLETE PROTECTION THROUGHOUT THE ADDITION OR REMODELED AREA OF WORK. ALTERATIONS TO THE FIRE ALARM SYSTEM SHALL BE APPROVED UNDER SEPARATE PERMIT. FIRE ALARM PLANS SHALL BE SUBMITTED WITHIN 30 DAYS OF ISSUANCE OF THE BUILDING PERMIT BY THE CONTRACTOR IN POSSESSION OF THE UNDERWRITERS LABORATORIES CERTIFICATE FOR THE BUILDING. NEWSYSTEMS: PROVIDE AFIRE ALARM SYSTEM CAPABLE OF NOTIFYING THE OCCUPANTS, AUDIBLY AND VISUALLY, UPON ACTIVATION OF THE AUTOMATIC FIRE SPRINKLER SYSTEM. THE FIRE ALARM SYSTEM SHALL BE INSTALLED BY A UNDERWRITERS LABORATORIES (UL) LISTED FIRE ALARM INSTALLATION COMPANY. UPON COMPLETION OF THE INSTALLATION A SERIALIZED CERTIFICATE SHALL BE ISSUED IN ACCORDANCE WITH THE LISTING AGREEMENT BETWEEN THE INSTALLER AND UNDERWRITERS LABORATORIES. PLANS AND PERMIT APPLICATION SHALL BE SUBMITTED WITHIN 30 DAYS OF ISSUANCE OF THE BUILDING PERMIT. WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE ONLY BY A QUALIFIED UL LISTED FORM ALARM CONTRACTOR WHO WILL PROVIDE THE GLENDALE FIRE DEPARTMENT W ITH A COPY OF A UL CERTIFICATE CERTIFYING PROPER INSTALLATION OF THE SYSTEM AND MINIMUM ONE (1) YEAR TESTING AND MAINTENANCE AGREEMENT PRIOR TO FINAL INSPECTION. SUCH SYSTEM SHALL BE MONITORED BYA UL LISTED CENTRAL STATION IN ACCORDANCE WITH CURRENT CFC CHAPTER 9. (AS APPLICABLE.) 6. EMERGENCY LIGHTING: EMERGENCY LIGHTING SHALL COMPLY WITH THE PROVISIONS OF CURRENT IBC 1008. THE MEANS OF EGRESS ILLUMINATION SHALL NOT BE LESS THAN ONE (1) FOOT-CANDLE AT THE WALKING SURFACE LEVEL. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL AREAS PER CODE. 7. EXIT SIGNS: EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL, BE ILLUMINATED AT ALL TIMES AND COMPLY WITH PROVISIONS OF THE CURRENT IBC 1013. 8. DOOR OPERATIONS: ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT KEY, SPECIAL KNOWLEDGE, OR EFFORT. THE UNLATCHING OF ANY EXIT DOOR SHALL NOT REQUIRE MORE THAN ONE OPERATION. 9. LOCKS AND LATCHES: THE LOCKING DEVICE FOR THE MAIN EXTERIOR EXIT DOOR(S) SHALL BE READILY DISTINGUISHABLE AS LOCKED. DOOR SHALL ALSO HAVE A VISIBLE DURABLE SIGN STATING: °THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." THE SIGN SHALL BE IN LETTERS ONE INCH HIGH ON CONTRASTING BACKGROUND (ABOVE THE DOOR); POSTED ON THE EGRESS SIDE OR ADJACENT TO THE DOOR.' (AS APPLICABLE.) I. INSTALLATION OF HOOD FIRE SUPPRESSION SYSTEMS SHALL BE APPROVED UNDER SEPARATE PERMIT. e. ADDITIONAL PERMITS: PRIOR TO FINAL INSPECTION, THE FOLLOWING ANNUAL PERMITS ARE REQUIRED FROM THE FIRE DEPARTMENT: I. HAZARDOUS MATERIALS • KITCHEN HOOD EXTINGUISHING SYSTEM • HAZARDOUS MATERIALS DOOR NOTES 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON THE WORKING DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES PRIOR TO COMMENCEMENTS OF ANY WORK IN THE EVENT OF FAILURE TO DO SO THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTION OF ANY ERROR. 2. PROVIDE HARDWARE AND ACCESSORIES AS REQUIRED FOR RATED AND MINERAL CORE DOORS. 3. CHECK DOOR SCHEDULE FOR DOOR THICKNESS, DETAILS OF TRIM CLEARANCES FOR HINGES, STRIKES, CLOSERS, FASTENER REQUIREMENTS, AND FIRE RATING REQUIREMENTS. 4. ALL NEW DOORS SHALL RECEIVE LEVER HARDWARE (SEE HARDWARE SCHEDULE) UNLESS NOTED OTHERWISE. HARDWARE SHALL BE IN COMPLIANCE WITH CALIFORNIA STATE HANDICAPPED REGULATIONS TITLE 24. 5. MAXIMUM ALLOWABLE DOOR CLOSER PRESSURE: a. INTERIOR DOORS: 5 POUNDS b. EXTERIOR DOORS:5 POUNDS c. FIRE DOORS: 15 POUNDS 6. ALL LABELED DOORS SHALL BE TIGHT -FITTING WITH A GASKET SO INSTALLED AS TO PROVIDE A SEAL WHERE THE DOOR MEETS THE STOP ON BOTH SIDES AND ACROSS THE TOP. 7. GENERAL CONTRACTOR SHALL PROVIDE MANUFACTURERS' CERTIFICATION THAT GLAZING ON DOORS AND WITHIN 4'-0' OF DOORS SHALL COMPLY WITH APPLICABLE CONSUMER PRODUCT SAFETY STANDARDS. UNDERSIDE OF B. THE CONTRACTOR SHALL DEVELOP AND SUBMITTO THE DESIGNER FOR APPROVAL HE) ROOF DECK AND COMPLETE SCHEDULE OF FINISH HARDWARE, INDICATING THE QUANTITY, PART (V.I.F.) NUMBER, INSTALLATION, LOCATION AND FINISH OF EACH ITEM AS NEEDED FOR A COMPLETE AND PROPER INSTALLATION. BID PRICE SHALL BE BASED ON THE HARDWARE SCHEDULE. CONT. METAL 9. HARDWARE SCHEDULE SHALL INCLUDE BUT NOT NECESSARILY BE LIMITED TO: BUTTS, TOP TRACK, TYP. 'I LOCKSETS, LATCHSETS, CLOSERS, WEATHERSTRIPPING, PANIC HARDWARE, FLOOR HINGES, PIVOTS, KICKPLATES, PULLS, STOPS, ANCHORS, WALL BUMPERS, THRESHOLDS, O DOOR SHOES AND MUTES. 5/8"GYPSUM BOARD 10. ALL DOORS TO HAVE INDIVIDUAL KEYS, STAMPED WITH ROOM NUMBER WITH ONE PAINTED PER MASTER KEY. CONTRACTOR TO SUBMIT 4 SETS OF EACH PRIVATE OFFICE DOOR AND 6 ELEVATION SETS OF KEYS FROM EACH AUXILIARY ROOM. 11. PROVIDE TENANT AN INDIVIDUAL KEY FOR ROOMS WITH "T" STAMPED ON THE KEY. 12. ALL LOCKS MUST BE KEYED TO A MASTER KEY WHICH IS TO BE STAMPED K1 QUANTITY OF 10 MASTER KEYS ARE REQUIRED. 3 5/8" x 20 GA. 13. CONTRACTOR TO PREP AND REWORKAND DRILL EXISTING DOORS AS WELL AS NEW CONT. METAL TRACK O METAL STUDS DOORS TO RECEIVE SECURITY HARDWARE WHEN APPLICABLE. @ i6" O.C., TYP. 14. EXTERIOR HINGED DOORS AND FOLDING DOORS SHALL READ IRE NOT MORE THAN 5 POUNDS FORCE TO OPEN. H 1 B404.2.9 CBC) DOUBLE'C' STUD HEADER EGRESS NOTES 1. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2. EXIT SIGNS ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54 LUX). 3. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURE'S INSTRUCTIONS AND SECTION 2702. 4. EXIT SIGN SHALL BE ILLUMINATED AT ALL TIMES.H 013.5) 5. EXITS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL PROVIDE AN ILLUMINATION OF NOT LESS THAN 90 MIN. IN CASE OF PRIMARY POWER LOSS (1013.6.3) 6. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.SEE 1010.1.9 FOR EXCEPTIONS. 7. DOOR HANDLES, LOCKAND OTHER OPERATING DEVICES SHALL BE INSTALLED ATA MIN. 34' AND MAX 48' ABOVE THE FINISHED FLOOR. 8. THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. 9. ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITH SECTION 1010. 10. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS OCCUPIED. 11. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT WALKING SURFACE. 12. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY TH E PREMISES' ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE FOLLOWING AREAS: a. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE TWO OR MORE MEANS OF EGRESS. b. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.; c. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EXIT DISCHARGE UNTIL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. d. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION 1028.1, IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. e. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1010.1.6, FOR EXIT DISCHARGE DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. 13. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON -SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM rrRELEASED FOR CONSTRUCTION TO PROVIDE INITIAL F-CANDLE (11 LUX) AND A ASURED ALONG THE PATH OF BE PERMITTED TO DECLINE TO WY POINT OF 0.06 FOOT-CANDLE IE DURATION. A MAXIMUM -TO HALL NOT BE EXCEEDED. Subject to compliance with all regulations of State and local Codes City of Camel �VT�Q1�Da�41WML DATE: 06/19/19 5/8' GYPSUM BOARD PAINTED MTL. PAINTED PER CORNER BEAD, TYR. FINISH SCHEDULE - DOOR SCHEDULE DOOR FRAME HARDWARE a REMARKS M ¢ W MATERIAL FINISH MATERIAL FINISH HINGES LATCHES MISC. -' O k w z Z s s F U d z < ¢ ¢ w O 0 W W y F Y p F O W m w a r/ 5 °o U g U g w z ¢ o f W t9 p 0 0 m o: r o? a F r c? 3 3 o. m mw iK iwa o¢W a: Q o r ? u w a w0 ­ mz O ¢ O¢ O O ¢ 0 x a ¢O MARK SIZE m¢ o_ a x m 00 m w o. o iW U o 101 VARIES EXISTINGTOREMAIN 102 T-0" x T-0" X 1 3/4" 2 91 110 KITCHEN 103 T-Omx T-OmX 13/4" 5 OFFICE/CORRIDOR 104 T-0" x 7'-0" X 1 3/4" 3 W OMENS 105 3'-0' x T-0" X 1 3/4' 1 4 MENS r7N), TYP. GWB CLG./ SOFFIT A101 SCALE: 3'=1'-0" (1) OR (2) DOOR SEE PLAN a DOOR TYPES A101 SCALE: N.T.S. 0 FRONT TO REMAIN. SUPPLY / INSTALL `3"GYP. BD. FROM F.F. TO STRUCTURE ABOVE. (FIRR OUT WALL WHERE INDICATED O w/20GA. MTL STUD SEE PLAN FOR SIZE) NOT USED LANDLORD PROVIDED INTERIOR WALL TO REMAIN. SUPPLY/ INSTALL `3"GYP. BD. FROM F.F. TO STRUCTURE ABOVE. 3 5/8" (or 6" WHERE INDICATED) METAL (20 GA.) @ 16" O.C. FULL HEIGHT w/ 5/8'GYP. BD. FROM F.F. TO BTM. OF STRUCTURE ABOVE (NOTE: 4�' ADD SOUND ATTENUATING INSULATION). 3 5/8" METAL STUD SOFFIT DROP FROM BOTTOM OF ROOF STRUCTURE TO TOP OF COOLER. 5/8" GYP. BD. & FRP ON KITCHEN SIDE. '" SEE SH EET A301 FOR FINISH SCHEDULE & A401 FOR 3 518" METAL STUDS �P SB' GYPSUM BOARD DOOR JAMB DETAIL A101 SCALE: 3/4" = 1'-0" 3518' METAL STUDS 5B"GYPSUM BOARD 54 i1 DOOR HEAD DETAIL A101 / SCALE: 3/4" = 1'-0" r ARCHITECTURAL HITECTURAL FLOOR PLAN A101 SCALE: 1/4"=1'-0" U_ C U) CC: C L C U, a C Iv 7580 48th Street, S.E. Grand Rapids, Mi. 49512 P. 616.634.2253 Glenn@rdc-Ilc.com ICU `W= a.. oL o M C� C) W f4 f9 Z j U - M CO- m Q(0Q DATE ISSUED FOR 03/15/2019 REVIEW G4/01/2019 Construction 04/23/2019 Per State Rev. 000uallNN iR nn� biyi�ix� F g'R"aCHIIpTNE�n:�1 gB THIS DRAWING IS THE SOLE PROPERTY OF RETAIL DESIGN CONSULTANTS LLC AND IS A COPYRIGHTED DOCUMENT AND IS NOT TO BE USED OR REPRODUCED WITHOUT WRITTEN CONSENT. A101