Loading...
HomeMy WebLinkAboutGN010.0-T101 TITLE SHEETACP ADUL AFF AST ATS ALT ALUM APPROX BD BLDG BLK BLKG BM B.O. BRG B/ CB C/C Ci CKT CLG CLR CNTR CMU CO COL CONC CONSTR CONTR CONT DET DIA DIM DIN US DW DWG EA EC EF EL ELEC ELEV EM EPS EQUIP EW EWC EWH FA FD FIFE FIN FLR FT FTG GALV GC GFI END GWB HOW HIM HORIZ HP HT HVAC ID IN INFO INSUL INT INV AMPERES ACOUSTICAL CEILING PANEL ADDITIONAL ABOVE FINISH FLOOR ABOVE SUB FLOOR ABOVE TOP OF SLAB ALTERNATE ALUMINUM APPROXIMATE BOARD BUILDING BLOCK BLOCKING BEAM BOTTOM OF BEARING BOTTOM OF CONDUIT CIRCUIT BREAKER CENTER TO CENTER CONSTRUCTION JOINT CIRCUIT CEILING CLEAR CENTER CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONCRETE CONSTRUCTION CONTRACTOR CONTINUOUS DETAIL DIAMETER DIMENSION DOWN DOWNSPOUT DRY WALL DRAWING EACH ELEC. CONTRACTOR EXHAUSTFAN ELEVATION ELECTRIC (AL) ELEVATOR EMERGENCY EXPANDED POLYSTYRENE EQUIPMENT EACH WAY ELECTRIC WATER COOLER ELECTRIC WATER HEATER FIRE ALARM FLOOR DRAIN FINISH FLOOR ELEVATION FINISH FLOOR FEET FOOTING GALVANIZED GENERAL CONTRACTOR GROUND FAULT INTERUPTER GROUND GYPSUM WALLBOARD HARDWARE HOLLOW METAL HORIZONTAL HIGH POINT OR HORSE POWER HEIGHT HEATINGNENTILATIONAIR CONDITIONING INSIDE DIAMETER INCH INFORMATION INSULATION INTERIOR INVERT Abbreviations JB JUNCTION TION BOX JT LAV LAVATORY LIN LINEAR LP LOW POINT LT LIGHT LTG LIGHTING LVL LAMINATED VENEER LUMBER MAX MAXIMUM MC MECH.CONTRACTOR NICE MAIN CIRCUIT BREAKER AIECH MECHANICAL MFR MANUFACTURE (R) (ING) MIN MINIMUM MISC MISCELLANEOUS MLO MAIN LUGS ONLY MO MASONRY OPENING MT MOUNT MTD MOUNTED MTGHT MOUNTING HEIGHT MTL METAL N NORTH OR NEUTRAL NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NO or# NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OPNG OPENING OPP OPPOSITE HAND PC PLUMB.CONTRACTOR FILMS PLUMBING PLYWD PLYWOOD PNL PANEL PNLBD PANEL BOARD PREFAB PREFABRICATED PROJ PROJECT PVC POLYVINYL CHLORIDE R RADIUS R RISER RD ROOF DRAIN RECEIPT RECEPTACLE REINF REINFORCING REQ'D REQUIRED RES RESILIENT REV REVISION RM ROOM RO ROUGH OPENING RTU ROOF TOP UNIT SECT SECTION BHT SHEET SIM SIMILAR SPEC SPECIFICATIONS STL STEEL STRUCT STRUCTURAL STRL. STRUCTURAL TEL TELEPHONE T&B TOP AND BOTTOM T & G TONGUE AND GROOVE T TREAD T.O. TOP OF TYP TYPICAL UON UNLESS OTHERWISE NOTED V VOLTS VCT VINYL COMPOSITION TILE VERT VERTICAL VWC VINYL WALL COVERING WC WATER CLOSET WD WOOD WH WATER HEATER VIP WATERPROOF WR WATER RESISTANT W/ WITH W/O WITHOUT WWF WELDED WIRE FABRIC CONTRACTOR NOTE: • ARCHITECT IS NOT RESPONSIBLE FOR ANY BIDDING OR AWARDING OF CONTRACTS, ALL INQUIRES ARE TO BE DIRECTED TO THE PROJECT OWNER. • THESE PLANS ARE FORBIDDEN ON ALL PLAN ROOM WEBSITES • IF A CONTRACTOR FINDS ANY CONFLICTING INFORMATION WITHIN THESE DOCUMENTS DURING THE BIDDING PROCESS A WRITTEN REQUEST FOR INFORMATION (RFI) MUST BE cFNIT Tn THE ARrF-1 AT THE EMAIL ON RELEASED FOR CONSTRUCTION THE CONTRACTOR Subject to TCall reNala°°"' I IILITY FOR THE WORST of Slat anncaodes City of Camel DATE: 06/19/19 C OO O BURGERIM Carmel, IN Sheet Index T101 TITLE SHEET LS1 LIFE SAFETY PLAN A101 ARCHITECTURAL FLOOR PLAN A102 EXTERIOR ELEVATIONS A201 EQUIPMENT PLAN & SCHEDULE A301 FINISH SCHEDULE A401 INTERIOR FINISH ELEVATIONS A402 TYP. RESTROOM PLAN & DETAILS A403 ARCHITECTURAL DETAILS M101 MECHANICAL AIR DISTRIBUTION PLAN M102 HOOD PLAN AND DETAILS M103 HOOD & EXHAUST DETAILS M104 HOOD & EXHAUST DETAILS E101 ELECTRICAL LIGHTING & POWER PLAN E102 ELECTRICAL SPECIFICATIONS P101 PLUMBING PLAN P102 PLUMBING DETAILS Code Review Summary Building Codes: Indiana Building Code, 2014 Edition (IBC, 2012 Edition, 1st printing) ANSI Al 17.1-2009 Indiana Plumbing Code, 2012 Edition (IPC, 2006 Edition) Indiana Electrical Code2009 Edition (NFPA 70-2008) Indiana Mechanical Code, 2014 Edition (IMC, 2012 Edition, 1st printing) Indiana Energy Conservation Code 2010 (ASHRAE 90.1, 2007 edition, as amended) Indiana Fire Code, 2014 Edition (IFC 2012 Edition, 1st printing) Indiana Fuel Gas code, 2014 Edition (IFGC, 2012 Edition, 2nd printing) ICC/ANSI -At 17.1: AMERICANS WITH DISABILITIES ACT (ADA) =NTY,UCTION: TYPE -2B- (UNPROTECTED) F. Leasible; 1,462 SF gross occupiableUSE GROUP: A-2NCY LOAD: 917/200 SFPP = 5 peoplePANCY LOAD: 545/15 = 36 peopleCY LOAD TOTAL = 41 people G.C. N TE. GENERAL CONTRACTOR IS TO H/REA PROFESSIONAL LICENSED SPRINKLER CONTRACTOR TO PROVIDE ALL MODIFICATIONS, DRAWINGS AND CALCULATIONS NECESSARY FOR THE NEW CONSTRUCTION. V.I.F. FOR EXISTING CONDITIONS. Site Location Map / e -per • M. Proiect General Notes • ALL WORK SHALL CONFORM TO THE CODES LISTED HEREIN, AND ALL OTHER APPLICABLE CODES, STANDARDS, AND REGULATIONS OF THE CITY. • IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. • THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A.I.A. 1997 EDITION) ARE A PART OF THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECT'S OFFICE. • DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO SUBMISSION OF BID IN THE FORM OF A "REQUEST FOR INFORMATION". FAILURE TO DO SO WILL BE AT THE EXPENSE OF THE CONTRACTOR • ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE CONSTRUCTION MANAGER, IN WRITING, PRIOR TO INSTALLATION • G.C. IS RESPONSIBLE FOR SUBMITTAL, PAYING FEES AND OBTAINING ALL PERMITS ASSOCIATED WITH THE PROJECT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, ENCROACHMENT PERMIT, ETC. G.C. REQUIRED TO PAY FOR TEMPORARY FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER. • ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS ARE NOT CLEAR. • THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL CONDITIONS AND DIMENSIONS. ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THESE PLANS SHALL BE REPORTED TO THE ARCHITECT PRIOR TO SUBMISSION OF BID. A SUBMISSION OF BID SHALL IMPLY THAT THE CONTRACTOR HAS ACCEPTED THE DRAWINGS AND EXISTING CONDITIONS HAVING BEEN FIELD VERIFIED BY SAME. • NOTE TO BIDDERS, PLANS WITH THE LAST DATE STATING PERMITS ARE TO BE CONSIDERED FOR BIDDING PURPOSES AND ADDITIONAL INFORMATION FROM THE MUNICIPALITIES MAY BE ADDED TO THE PLANS PRIOR TO THEM BEING ISSUED FOR CONSTRUCTION. SUCCESSFUL BIDDER IS RESPONSIBLE TO CONTACT THE ARCHITECT PRIOR TO COMMENCING CONSTRUCTION TO OBTAIN THE APPROVED SET OF PLANS. • SITE SUPERINTENDENT MUST BE PRESENT THE FIRST DAY ANY SUBCONTRACTOR IS ONSITE TO ENSURE SCOPE OF WORK IS UNDERSTOOD AND FOLLOWED. NOTE: THIS IS A TENANT SPACE IN A NEW SHOPPING CENTER THAT HAS NEVER BEEN OCCUPIED. NO DEMOLITION SHOULD BE NECESSARY ff lu C (6 U) to C C L. C C U a; C N 758048th Street, S.E. Grand Rapids, Mi. 49512 P. 616.634.2253 Glenn@rdc-Ilc.com 61.E of (D co O �Y� let Co @ Z E E > 1_ Q L UcoU DATE ISSUED FOR 03/15/2019 REVIEW 04/01/2019 Construction 04/23/2019 Per State Rev. ououallNN iR nn� biyi�i�� goo• ��.E.........gHy ,Q�otsregFo = i N0. AR110001fi] ` F � • D Monte THIS DRAWING IS THE SOLE PROPERTY OF RETAIL DESIGN CONSULTANTS LLC AND IS A COPYRIGHTED DOCUMENT AND IS NOT TO BE USED OR REPRODUCED WITHOUT WRITTEN CONSENT. T101