HomeMy WebLinkAboutM101 MECHANICAL SHEETTWO-PIECE COUNTER FLASHING BASE FLASHING 60 MIL MEMBRANE (INSTALLED PER MFR.) ON 3" RIGID INSULATION, ON METAL DECK SEE STRUCT. WOOD NAILER THRU BOLT TO DECK WITH 3/8" DIA. BOLTS AT STRUCTURAL FRAMING WOOD NAILER PREFABRICATED ROOF CURB W/ INTEGRAL FIBER GLASS INSULATION CANT STRIP PROVIDE WELL LINER OR DUCT CONNECTION WHERE REQ'D. FASTEN TO METAL. CURB 8 WELD TO STRUCTURAL FRAMING TYP. ROOF CURB DTL. M 101 SCALE: 1" = 1'-0" MC6K15.3 C/L OF BAR JOIST II II II K�OUTUINIE ��2 C6X6.2 OF MECH. UNIT I I I II II I I II II I MQ6%15.3 /'6� TYP. ROOF CURB PLAN M101 SCALE: 1/2"=1'-0" GIST SPACING, SEE PLAN RqPF OPENIUG L6x4x3/8x6" LG. STRUCTURAL STEEL: (LLV) - TYP C SHAPES: ASTM A36 UNO PLATE, ANGLES ASTM A36 UNO L6x4x5/16 TUBES" ASTM A500 GRADE B(Fy = 46 KSI) (LLR) TYP. EACH SIDE OF DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO THE LATEST AISC SPECIFICATIONS. /1 P. ALL WELDING SHALL BE DONE USING E-70XX *FOR ALL ROOF OPENINGS 12" OR ELECTRODES IN ACCORDANCE WITH THE LATEST AWS MORE. SPECIFICATIONS. COORDINATE OPENING SIZES AND PRIMEA ALL STEEL NOT IN CONTACT WITH CONCRETE. LOCATIONS WITH ARCHITECT AND M.C. j:) TYP. ROOF OPENING DETAIL M101 SCALE: 1/2"=1'-0" STEEL SHIMS O 2'-0" MECH. UNIT O.C. (NOTE REQ'D IF TAPERED CURBS ARE PROVIDED) MECH. CURB �CONT. MC605.3 L REINFORCEMENT TYP WHEN GREATER THANAN 6" 6" /8 L7 3x1 JxA EA SIDE /71 TYP. RTU SUPPORT M101/ SCALE: 1/2"=1'-0" RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 06/19/19 MECHANI SCALE: 1 /4" = 1'-0" DUCTWORK & AIR DISTRIBUTION NOTES 1. ALL DUCTWORK SHALL BE INSTALLED STRAIGHTAND TRUE IN A QUALITY WORKMANLIKE FASHION. 2. ALL DUCTWORK SHALL CONFORM TO ASHRAE AND SMACNA STANDARDS WITH REGARDS TO DUCT GAUGES, TURNING VANES, THE INSTALLATION OF THE TURNING VANES AND/OR EXTRACTORS, AND MOUNTED AND BRACING. 3. RECTANGULAR DUCT CONSTRUCTION 4. GALVANIZED IRON PER SMACNA 5. DUCT WIDTH U.S. STD BRACING INCHES 6. IN INCHES GAUGE GALV.ANGLE SPACING 1-12 26 Ga. - - 13-24 24 Ga. - - 25-30 24 Ga. 1X 1 X 1/8 48 31-40 22 Ga. 1X1X1/8 48 41-60 22 Ga. 11/4 x 11/4 x 1/8 24 61-90 20 Ga. 11/2 x 11/2 x 1/8 24 91-OVER 18 Ga. 11/2x 11/2x 1/8 24 7. STEEL OR ALUMINUM DUCTWORK SHALL CONFORM WITH DEPT.OF COMMERCE CHAPTER 63.29(3) AND 64.34(184), AS WELL AS SMACNA SEAL CLASS'C'. FRESH AIR DUCTWORK, AND ANY DUCTWORK EXTERIOR OF TH E BUILDING SHALL BE INSULATED WITH MATERIAL NO LESS THAN R-9. SUPPLY -AIR DUCTWORK NOT IN THE CONDITIONED SPACE SHALL BE INSULATED WITH MATERIAL NO LESS THAN R-5. 8. TH E HVAC CONTRACTOR SHALL CONSULT WITH THE GENERAL CONTRACTOR AND/ OR THE BUILDING OWNER(S) TO DETERMINE THE EXACT LOCATION OF REGISTERS, GRILLES, AND DIFFUSERS. HVAC DRAWINGS INDICATE QUANTITIES AND AIR FLOW SPECIFICATIONS, HOWEVER, LOCATIONS ARE DIAGRAMMATIC. 9. THE HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR BALANCING THE ENTIRE SYSTEM SO THAT TH E SUPPLY AIR, RETURN AIR, EXHAUST AIR, AND FRESH AIR ARE WITH IN +/-5% OF THE AIR QUANTITIES SHOWN ON TH E PLAN. THE HVAC CONTRACTOR SHALL FURNISH THE HVAC DESIGNER WITH TWO COPIES OF THE BALANCE DATA. 10. INSULATED FLEXIBLE SUPPLY AIR DUCT RUNS SHALL NOT EXCEED FIVE (5) FEET IN LENGTH. 11. HVAC CONTRACTOR SHALL FURNISH AND INSTALL PLEATED FILTERS WITH AN AVERAGE ARRESTANCE OF 85% OR GREATER, OR HIGHER EFFICIENT FILTER MEDIA TYPES. FILTERS SHALL BE EASILY ACCESSIBLE IN FILTER RACK OR FILTER GRILLES. 12. HVAC CONTRACTOR SHALL FIELD ROUTE DUCTWORK AS REQUIRED TO AVOID INTERFERENCE WITH SUSPENDED ACOUSTICAL CEILING HEIGHT. COORDINATE WITH GENERAL CONTRACTOR. 13. ALL ELECTRICAL FIXTURES SHALL BE PROVIDED BY THE ELECTRICIAN, AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED, SEE E101. 14. FOR SYMBOLS SHOWN IN LEGEND, BUT NOT ON THE PLAN, REFER TO THE MECH. AND ELEC. DRAWINGS. 15. EACH UNIT SHALL PROVIDE IONIZATION TYPE RETURN AIR DUCT SMOKE DETECTION. 16. SMOKE DETECTION SYSTEM WILL CONSIST OF IONIZATION TYPE SAMPLING TUBE, SMOKE DETECTOR WITH AUDIBLE ALARM, LED INDICATOR, AND MANUAL TESTRRIP KEY. GAS PIPING NOTES; 17. ALL GAS PIPING SHALL BE RUN STRAIGHTAND TRUE AND BE INSTALLED IN A QUALITY WORKMANLIKE FASHION. 18. GAS PIPING SHALL CONFORM TO ALL STATE AND LOCAL CODES, AS WELL AS NATIONAL FUEL GAS CODE RECOMMENDATIONS. 19. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL SCHEDULE 40 STEEL GAS PIPING AND FITTINGS. HVAC CONTRACTOR SHALL INSTALL ALL NECESSARY VALVES, FITTINGS, REGULATORS, AND SAFETY AND OPERATING DEVICES. VENTING NOTES: 20. ALL GAS FIRED APPLIANCE VENTING SHALL COMPLY WITH STATE AND LOCAL CODES AND BE DONE IN A QUALITY WORKMANLIKE FASHION. 21. ALL VENTING SHALL STRICTLY COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS. 22. ALL FRESH AIR INTAKES SHALL BE A MINIMUM OF 10' AWAY FROM ANY EXHAUST VENT, SOIL VENT PIPE, OR GAS METER. 23. ALL GAS FIRED APPLIANCE VENTS SHALL BE A MINIMUM OF 1 O'-0" AWAY FROM ANY WINDOW, DOOR, OR BUILDING ENTRANCE.AND MANUAL TEST/TRIP KEY. MECHANICAL NOTES 1. AFIELD VISIT IS REQUIRED TO THE SITE TO VERIFY THE FIELD CONDITIONSAND LAYOUTOF EXISTING DUCTWORK. ALL WORK REQUIRED TO COMPLETE THE REWORK OF DUCTWORK IN THE SPACE SHALL BE INCLUDED IN THE BASE BID FOR THE PROJECT. 2. ALL WORK AND MATERIALS SHALL COMPLY WITH GOVERNING CODES, SAFETY ORDERS AND REGULATIONS. 3. OBTAIN AND PAY FOR ALL NECESSARY PERMITS, FEES AND INSPECTIONS REQUIRED BY GOVERNING AUTHORITIES. 4. ALL FLEX DUCT SHALL BE UL 181 LISTED. 5, ALL BRANCH DUCTS FEEDING INDIVIDUAL DIFFUSERS SHALL HAVE DAMPERS AT TAKEOFFS FOR AIR BALANCING. PROVIDE ACCESS PANELS TO DAMPERS AS MAY BE REQUIRED BY THE GENERAL TRADES CONSTRUCTION, SEE ARCHITECTURAL PLANS. 6. ALL OUTSIDE AIR INTAKES SHALL BE MINIMUM OF 1O'-0" FROM EXHAUST FANS AND / OR VENTS. 7, FINAL HVAC BALANCING SHALL BE PERFORMED BY THE HVAC CONTRACTOR AS A PART OF H IS BASE BID FOR THE PROJECT. IN WHEN REMOVING DIFFUSERS AND SHORTENING EXISTING DUCTING, MECHANICAL CONTRACTOR IS RESPONSIBLE FOR RE -BALANCING HVAC SYSTEM. 8. MECHANICAL CONTRACTOR TO INSTALL DUCT WORK TO EF-1 AS SHOWN UNLESS APPROVED BY ARCHITECT AHEAD OF TIME. 9. SEE SHEET M102 FOR HOOD, WELDED DUCT, FIRE WRAP AND EXHAUST FAN. THE HOOD AND EF-1 ARE PROVIDED BY THE OWNER INSTALLATION AND CONNECTION FOR PROPER OPERATION ARE BY THIS CONTRACTOR. 10. EF-1 IS TO BE INSTALLED ON THE ROOF. PROVIDE A ROOF CURB DESIGNED FOR THE SLOPED ROOF. VERIFY ROOF PITCH AT ALL LOCATIONS. 11. ALL EXHAUST AND VENTS SHALL BEA MINIMUM OF IO'TO PROPERTY LINES. DIFFUSER AND GRILLE SCHEDULE SYMBOL MAKE BOOT NEC, MODEL NO. PRICE POE PERFORATED W/ INSULATED BOOT 8 AS STATED 2-WAY BLADES 9:i [6>!:i>r Oli 9 C115 MODEL BOFF W/ AS STATED INSULATED BOOT 8 REMOVABLE FILTER 181:14111MMIM 011 W IMMA1*41�. v EXHAUST FAN NUMBER e DIFFUSER TYPE INDICATES GEM QUANTITY V AFF) NUMBER I NDICATES HVAC NUMBER O SMOKE D ETE CT OR MOUNTED IN THE RETURN PLENUMS OF HVAC UNITS. �TTIIII CONTROL DAMPER FLEXIBLE DUCT WITH INSULATION �P NUMBER DENOTES INSIDE DIAMETER EMERSON 1F97-1277 or EQUIVALENT HONEYW ELL O EQUIVALENT AUTOMATIC CHANGEOVER THERMOSTAT (r@ 54' A.F.F. NUMBER INDICATES HVAC NUMBER.) J C (73 U) CC: C C C U, a C 0) (i 758048th Street, S.E. Grand Rapids, Mi. 49512 P. 616.634.2253 Glenn@rdc-Ilc.com a W= L a)0 M Q a)Ev f6 (� Z u .J U EE L O L Df Lid M C.) (o U DATE ISSUED FOR 03/15/2019 REVIEW 04/01/H019 Construction 04/23Y2019 Per State Rev. omaoolNN IR nn� biyi�ix� goo• ............. ".., i Na. AR110001fi] `: gRaCHITEn�1 THIS DRAWING IS THE SOLE PROPERTY OF RETAIL DESIGN CONSULTANTS LLC AND IS A COPYRIGHTED DOCUMENT AND IS NOT TO BE USED OR REPRODUCED WITHOUT WRITTEN CONSENT. 101