Loading...
HomeMy WebLinkAboutM104 HOOD DUCT WORKREVISIONS ft NIP w ADJUSTABLE HE wa FEE TTHA IT( u MUTE. TRACTION PIER � CECTma 91 M mT � "TER RUTa SILL to.Lwt SETA MATE ADJUSTABLE EaUR TER MLL ORI AR. MI STETNN TRANSITION PLATE DETAIL HIGH TEMP GASKET Is BE& THE FAN TO THE TRANSITION PLATE. VENTED CURB ROOF TERMINATION. LISTED Duct run shown is for example purposes only. See mechanical plans for additional information. dditional information including installation manual available www.captivealre.com. CHAUsIBAN. IF INNER DUCT IS FULLY WELDED TO AE TRANSITION PLATE, ALL WELDS ARE YE TESTED. FIGURED TO THE URB BY OTHER. " ��- ��x�, "moo ""a EI 'RE MERCER Fwnf RE Furnish double wall, factory built grease duct for use with Type I kitchen hoods, which conforms to the requirements of A F NOM.AN NOW NFPA-96. Products shall be ETL listed to UL-1978 and UL-2221 for venting air and grease vapors from commercial cooking operation. Models DW-2R, 3R and 3Z are used for grease duct applications when installed in accordance with these instructions and National Fire Protection Association "NFPA 96", Standard for Ventilation Control and Fire - — - - --- ""` Protection of Commercial Cooking Operations. Double wall grease ducts are listed for a continuous internal temperature of 500 degrees F and intermittent temperatures of 3000 degrees F. The duct sections shall be constructed of an inner duct wall and an outer wall with insulation in between. The inner duct wall shall be constructed of .036 inch thick, 430 type stainless steel and be available in diameters 8" through 24". The outer wall shall be constructed of stainless steel at a minimum of .024 inch thickness. The duct, based on model number, IUTER DUCT BAND DETAIL shall include layers of Super Wool 607 Plus insulation between the inner and outer wall. Grease duct joints shall be held together by means of formed V clamps and sealed with 3M Fire Barrier 2000+. The duct wall assembly shall be tested and listed at'W or zero inch clearance, according to classifications. LEARNCED CDCE Classifications and Clearances EERE DOUBLE EA -BAND DUCT 1 D "T 'IN T) Er FIELD VERDES, PARTS SUBJECT TO CHANCE L OR INNER DUCT CIA TEE TO 24 fiBAJ RT _E J _T OVERLAP 10 BE NO LESS PLAN 6 i UNLESS RELEASED FOR CONSTRUCTION UL 2221: Standard for Fire Resistive Grease Duct Enclosure Assemblies. Chapter 7 of this standard references a test labeled Internal Fire Test. Section 7.1.1 references two installation conditions, Condition A and Condition B. Condition A represents all installation condition except for installation within non -ventilated combustible enclosures. Condition B represents installation within a non -ventilated combustible enclosure. Model DW-3Z is classified under UL2221 (Test of Fire Resistive Duct Enclosure Assemblies) as an alternate to 2-Hr. fire resistive shaft enclosures with a minimum zero clearance to combustibles (sizes 8" to 24" diameter). Model 3Z is listed in accordance with the requirements for duct enclosure Condition A and B. Model DW-3R is classified under UL2221 (Test of Fire Resistive Duct Enclosure Assemblies) as an alternate to 2-Hr. fire resistive shaft enclosures with a reduced clearance to combustibles (sizes 8" to 24" diameter). Model 3R is listed in accordance with the requirements for duct enclosure Condition B. Model DW-2R is classified under UL2221 (Test of Fire Resistive Duct Enclosure Assemblies) as an alternate to 2-Hr. fire resistive shaft enclosures with a reduced clearance to combustibles (sizes 8" to 16" diameter). Model 2R is listed in accordance with the requirements for duct enclosure Condition B. Subject to compliance with all regulations of State and Local Codes City Ed Carmel �VT�Vt�B*S41WML_ DATE: \\ 06/19/19 GREASE DUCT IS NOT IN OWNER'S PACKAGE. PROVIDED BY GC Insi in ARE 1 DATE: 3/29/201 9 DWG.M 3774882 DRAWN RJC - 81 BY: SCALE: 3/4" — 1' n' Specification 61:14=111dI![all D_ c t>3 U) to c C C C U, a C IY 7580481h Street, S.E. Grand Rapids, Mi. 49512 P. 616.634.2253 Glenn@rdc-Ilc.com W .� W > 0 W I N M � O ry�NEv W J U Z iJ CDE UcLODU DATE ISSUED FOR 03/1512019 REVIEW 04/01/2019 Construction 04/23/2019 Per State Rev. omaooTNN IR nn� biyi�iY� goo• �\.E,_.......4Hy RI //�''yq gRaCHITEn�\�� THIS DRAWING IS THE SOLE PROPERTY OF RETAIL DESIGN CONSULTANTS LLC AND IS A COPYRIGHTED DOCUMENT AND IS NOT TO BE USED OR REPRODUCED WITHOUT WRITTEN CONSENT. M 104