HomeMy WebLinkAboutP102 PLUMBING DETAILSRELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City
of Camel
�VT�QtBN�1DA�
DATE: \ 06/19/19
VENTING MUST COMPLY
WITH NATIONAL CODES,
LOCAL CODES AND
STS
MANUFACTURER'S
WGICPVC VENT PIPING
TM1am-X-TroI
INSTRUCTIONS
BY PLUMBER
Expansion Tank
VENTING TO BE 6"
SINGLE TURN FOR
WATERHEATER.
SEALED COMBUSTION UNITS (ALL
COMBUSTION AIR FROM OUTSIDE
OFTHEBURDING)
-PROVIDE CODE APPROVED
CONDENSATEDRAIN
TANKLESS
WATER
SPECIFYINWJROR
COLD
HEATER
OUTDOORUNIT
WATER
RINNAI-RUCWII
SHUTOFF
REU-KBD3237FFUD
POWER TZO VOLTS
VALVE
(REFER TO MANUFACTURER
PRESSURE
SPECIFICATIONS)
RELIEF
VALVE
"B"' PAN REWIRED IF
INSTALLED IN AN AREA
HOT
WHERE WATER DAMAGE
Tr
CAN OCCUR
I
GAS GAS SUPPLY UNE PROVIDE
SHUTOFF )CHECK RATING PLATE FOR CORRECT GAS SUITABLE
VALVE TYPE AND PRESSURE) DRAIN
NOTES'
-WATER HEATER MUST BE INSTALLED TO CONFORM WITH CURRENT NATIONAL ELECTRIC CODE,
NATIONAL FUEL GAS WIDE, AND MY APPLICABLE LOCAL PLUMBING, ELECTRICAL HEATING AND MR
CONDITIONING CODES, AND MANUFACTURER INSTALLATION INSTRUCTIONS
-PROTECT HEATER FROM FREEZING
-SPECIFY NATURAL GAS OR PROPANE
1 TANKLESS WATER HEATER
DETAIL
SCALE: NONE
DIAGRAM KEY NOTES
1. FLOOR LINE.
2
2. 1/8 BEND.
3. CLEANOUT AND ACCESS COVER
-O4 TOP OF COVER TO BE FLUSH WITH
TOP OF FLOOR.
O O 4. WASTE LINE LENGTH TO SUIT.
8 5. WASTE PIPING. SEE PLANS FOR
SIZE AND ROUTING.
6. 118 BEND IF CLEANOUT OCCURS
AT END OF LINE.
is1 FLOOR CLEANOUT DETAIL
P102/ SCALE: NO SCALE
V
DIAGRAM KEY NOTES
1. VENT. SEE PLANS FOR ROUTING.
1
2. WASTE. SEE PLANS FOR ROUTING.
3. FLOOR.
4. TRAP ARM.
5. INDIRECT WASTE RECEPTOR PER
PLANS.
6. AIR GAP PER CODE.
7. INDIRECT DRAINS. CLUSTER
CLOSELY TOGETHER, AND
SUPPORT PER CODE.
Z
s INDERECT WASTE DETAIL
P102 SCALE: NO SCALE
n
IM
DIAGRAM KEY NOTES
1. MAY EXTEND AS WASTE OR VENT.
2. FLOOR LINE.
,-/ 3. 1/8 BEND.
4. SEE PLANS FOR CONTINUATION.
5. WALL.
6. WALL COVER AND SCREW.
COORDINATE HEIGHTAND FINISH
�i WITH ARCHITECTURAL.
WALL CLEANOUT DETAIL
P102 SCALE: NO SCALE
(- 1
O O
O
DIAGRAM KEY NOTES
1.
COLD WATER. REFER TO PLANS
FOR CONTINUATION.
2.
TRAP PRIMER VALVE LOCATED
MINIMUM 1'-0" ABOVE FINISHED
FLOOR. MOUNT AND SECURE
PIPING AND TRAP PRIMER TO
WALL WITH UNISTRUT OR EQUAL.
3.
PROVIDE DISTRIBUTION UNIT
WHERE REQUIRED.
4.
TRAP PRIMER LINE TO DRAIN.
5.
ACCESS PANEL. COORDINATE
LOCATION WITH ARCHITECTURAL.
( TRAP PRIMER DETAIL
P102 SCALE: NO SCALE
DIAGRAM KEY NOTES
1. KITCHEN EQUIPMENT.
^\
2. FINISH FLOOR.
3. NEAREST WALL.
s
4. VERTICAL FIXTURE DRAIN.
5. VERTICAL FIXTURE VENT.
6. WYE BRANCH FITTING.
O
7. FOOT VENT, SLOPE AT 2% BACK
J
TO DRAIN.
4
6
8. WCO=WALL CLEANOUT.
10
9. HORIZONAL FIXTURE DRAIN.
9
10. SEE FLOOR PLAN FOR
CONTINUATION.
ISLAND VENT
PIPE DETAIL
P102
SCALE: NO SCALE
ff IL
11111111W VC
C
(r
C
U
C
a
d
(zl
d
7580 48th Street, S.E.
Grand Rapids, Mi. 49512
P. 616.634.2253
Glenn@rdc-Ilc.com
N �
Q �
d! CD
D E �
J C.)Z
1E E
1U
U co U
DATE ISSUED FOR'
I)WlW2019 REVIEW
04/01/2019 Construction
04/23/2019 Per State Rev.
�6VENN.R'uR H�L ��o.
_' .Q��lsregFo
i No. AR11000167 j `_
F
' w ... Dr
!niiio°
RCHle 'TEUt�ao"\`�
THIS DRAWING IS THE
SOLE PROPERTY OF
RETAIL DESIGN
CONSULTANTS LLC AND IS
A COPYRIGHTED
DOCUMENT AND IS NOT
TO BE USED OR
REPRODUCED WITHOUT
WRITTEN CONSENT.
P102