HomeMy WebLinkAboutL100 Life Safety2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1ST FLOOR CODE SUMMARY SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE PREVIOUS USE OF SPACE B(USINESS) OCCUPANCY CLASSIFICATION BIUSINESSI CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA 1,325 SF/FLOOR X 1 2 STORIES = 2,650 SF TOTAL PROJECT AREA 2,650 SF SPACE TYPE AREA SF PEROCCUPANT OCCUPLOAD OCCUPANCY CALCULATIONS NUMBER OF EXITS I ST FLOOR F325 SF 1001 14 2ND FLOOR 1,325 SF I too 14 TOTAL OCCUPANTS IN PROJECTAREA 28 REQUIRED:I PROVIDED:2 SPRINKLER SYSTEM YES/NO) NO TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR IST FLOOR: 1,325 1 2ND FLOOR: 1,325 ACCESSORY AREA EXC EEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO BUILDING CONSTRUCTION TYPE V-A LEGEND Ep MISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT (BUILDING STAIR LOCATION ON 2ND FLOOR) TIfe FIRE EXTINGUISHER EXIT SIGN/ EMERGENCY LIGHT COMBO --- TRAVELDISTANCE ® EMERGENCY LIGHT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Calmed DATE: 06/21/19 LIFE SAFETY NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10, COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. m RR' CAFE TIME TRAVEL DISTANCE =40' SIG. CONFERENCE Iz-oxla,Io. I Lei I ENTRY / MFETING / e fig EX 1ST FLOOR GENERAL NOTES LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEETALL LOCAL AND STATE CODES. RR' i I I I I I I I I I I I I I I I I ][-6 E-6 L J J OPEN OFFICE ME 0 2' 4' 8' 16 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. J Li 10 Z N N C�I1+O `J ~ o L a n RaRaR� � — Q W J V Li LU uJ CLWV� �OQ =U CD %10 N N R— ISSUE 4 DATE DESCRIPTION 05.22.19 PERMITSET REVISIONS MARK DATE I DB DESCRIPTION AR10700017 STATE OF MOW PROJECT NUMBER 2018.519 PROD. MGR DRAWN BY AS AS iiiiiiim LIFE SAFETY IN L100'