1ST FLOOR CODE SUMMARY
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE
PREVIOUS USE OF SPACE
B(USINESS)
OCCUPANCY CLASSIFICATION
BIUSINESSI
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
1,325 SF/FLOOR
X
1 2 STORIES
=
2,650 SF
TOTAL PROJECT AREA
2,650 SF
SPACE TYPE AREA SF PEROCCUPANT OCCUPLOAD
OCCUPANCY CALCULATIONS
NUMBER OF EXITS
I ST FLOOR
F325 SF
1001
14
2ND FLOOR
1,325 SF
I too
14
TOTAL OCCUPANTS IN PROJECTAREA 28
REQUIRED:I PROVIDED:2
SPRINKLER SYSTEM YES/NO)
NO
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
IST FLOOR: 1,325 1 2ND FLOOR: 1,325
ACCESSORY AREA EXC EEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
ASHRAE 90.1 SUMMARY
REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978?
NO
BUILDING CONSTRUCTION TYPE
V-A
LEGEND
Ep MISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT (BUILDING STAIR LOCATION ON 2ND FLOOR)
TIfe FIRE EXTINGUISHER
EXIT SIGN/ EMERGENCY LIGHT COMBO
--- TRAVELDISTANCE
® EMERGENCY LIGHT
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Calmed
DATE: 06/21/19
LIFE SAFETY NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10, COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
m
RR'
CAFE
TIME
TRAVEL DISTANCE =40'
SIG.
CONFERENCE
Iz-oxla,Io.
I
Lei
I
ENTRY
/ MFETING
/
e
fig EX
1ST FLOOR
GENERAL NOTES
LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS
REQUIRED TO MEETALL LOCAL AND STATE CODES.
RR'
i
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
][-6 E-6
L J J
OPEN OFFICE
ME
0 2' 4' 8' 16
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
J
Li
10
Z
N
N
C�I1+O
`J
~
o
L
a
n
RaRaR�
�
—
Q
W
J
V
Li
LU
uJ
CLWV�
�OQ
=U
CD
%10
N
N
R—
ISSUE 4
DATE
DESCRIPTION
05.22.19
PERMITSET
REVISIONS
MARK DATE I DB DESCRIPTION
AR10700017
STATE OF
MOW
PROJECT NUMBER
2018.519
PROD. MGR DRAWN BY
AS AS
iiiiiiim
LIFE SAFETY
IN
L100'