HomeMy WebLinkAboutT111 Cover Sheet & General NotesGENERAL PROJECT NOTES L BUILDING CODE COMPLIANCE: ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THEGENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 2. CONTRACTOR SITE VISIT$:CONTRACTORS SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTORS) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 3. CONTRACTOR FIELD VERIFICATION: FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE, VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GEN ERAL CONTRACTOR TO SCHOTT DESIGN. INC. 4. GENERAL CONTRACTOR COORDINATION WITH OWNER: THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ONSITEACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY i0 EXECUTE THE OVERALL PROJECT SCOPE. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION i0 NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION 15 DEEMED i0 INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. 5. PROJECT MATERIAL LEAD TIMES: FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE, THE OWNER, TENANT, OR DESIGNER/ARCHITECT 6 NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTORS FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 6. MATERIAL SUBSTITUTIONS: SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. 7. SAFE WORK AREA: SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. 8. GENERAL CONTRACTOR CLEANUP PROCEDURES: THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER i0 CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. 9. STAGING/ PARKING/ DUMPSTERS/ RESTROOMS: THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. 10. DUST CONTROL: THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS i0 MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS ® 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE. 11. PROJECT INSTALLATION CONFLICTS: CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE NSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). 12. SCHOTT DESIGN HAZARDOUS MATERIALS WAIVER: SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECTSITE. 13. WOOD BLOCKING IN WALLS: PROVIDE FIRE -TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC, 14. SHOP DRAWINGS: SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED i0 SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES i0 DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 15. PROJECT APPROVALS: ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT i0 FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER. 16. CHANGE ORDERS: REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS& CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PREBIDFIELD INSPECTION AND AFTER AWARD OF CONTRACT. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Canted (� �VT�LD'�B*4'aWML DATE: 06/21/19 17. FURNITURE AND EQUIPMENT EXCLUSIONS: FURNITURE, OFFICE EQU I PMENT OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ON LV AN D ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED i0 BE PROVIDED, 18. WALL PATCHING: PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 19. CONSTRUCTION CLEANING: EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER i0 THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK. 20. O & M MATERIALS: PROVIDE i0 THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 21. PLAN DIMENSIONS: ALL PUN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 22. WINDOW BLINDS: CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 23, PERMITTING: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 24. FIRE SEALING: FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON LIDO IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION. 25, WALL PENETRATIONS: WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED i0 FITTIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 26. FLOOR LEVELING: CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED i0 RECEIVE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. 27. REPAIR GYPSUM WALLBOARD: WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN i0 EXISTING CORE WALLS. 28. EQUIPMENT INSTALLATION: ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. FINISH NOTES I. STATE BUILDING COMPLIANCE FOR FINISHES: ALL FINISHES SHALL COMPLY WITHCHAPTER8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. 2. GYPSUM ASSOCIATION CONFORMITY: FOR ALL NEW DRYWALL NSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.) PROVIDE NEW CEMENT BACKER BOARD AS A SUBSTRATE FOR NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS. 3. COVER PLATES: REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR TO PURCHASING NEW. 4. PAINTING: ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. 5. FLOORING TRANSITION STRIPS: FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN UNLESS NOTED OTHERWISE F.E. WHERE VCT MEETS CARPET). 6. DELIVERY OF COMPREHENSIVE WORK PRODUCT: WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. WALL DEMOLITION: REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN i0 EXISTING CORE WALLS, 8. TELEPHONE BOARDS: WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT i0 MATCH ADJACENT WALL FINISH. 9. MILLWORK SAMPLES: SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) i0 SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 10. INTERIOR ELEVATION DETAILS: REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION. 11. PAINT & ADHESIVE VOC'S: ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE ZERO VOC CONTENT, 12. ADHESIVE MANUFACTURER RECOMMENDATIONS: ALL ADHESIVES/SEALANTS i0 BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. IM *6, K_I MEP:' 'COPES SCOPES OF WORK ARE WHI CH ARE OUTLI NED II S. THE DESIGN -BUILD CONTRACTORS FOR EACH TRADE MUST A RCHITECT IF TH EYFIND THATTHE SCOPE OF WORK EXCE L OF MECHANICAL, ELF FRICAL OR PLUMBING WORK INDIC DON iHES E DRAWINGS 50 THAT A NV NECESSARY ENGINEERIF AN OCCURAND ADDITIONAL PLA NS CAN BE FILED, OR IF ADDITIONA ORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD, THE CHANICAL ELECTRI CAL A N D PLUM BI NG DESIGN -BUILD CONTRA RS SHALL COMPLY WITH ALLAPPLICABLE STATE AND LOCAL BUILI CODES. FIRE SUPPRESSION AND ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN-E CONTRACTOR AND MUST COMPLY WITH ALL APPLICABLE STATE AND AL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIG JILD CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILI N EIR PLANS AND OBTAINING THE R PERMITS. 2. DESIGN/BUILD HVAC ECHANICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL AS NCES OR MAIN EQUIPMENT ARE BEING PROVIDED, ALL MECHf AL WORK IS LIMITED i0 RELOCATION OF DIFFUSERS AND FLEX DU PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPN TI5 BEING ADDED; MECHANICAL CONTRACTOR IS TO NC APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADL PHAL PLANS CAN BE FILED AND M UST COMPLY WITH THE INDIANA MEC NICAL CODE AND ALL OTHER APPLICABLE CODES, 3. HVAC HEAT LOADS: PIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, i PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER OR TO ANY PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQU D. DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLI ONE UNLESS APPROVED BY BUILDING OWNER/LANDLORD. C( TRACTOR TO ENSURE THAT ALL HVAC ZON ES ARE LOCATED APPROP YELP SUCH THAT NO SPLIT SON ES ARE IN OFFICES OR CONFEREN :ROOMS. 4. HVAC DIFFUSER LOC IONS: RELOCATE AIR- SUPPLY DIFFUSERS AND RETURNAIRGRILLES AS DUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN 2 FROM RETURN AIR GRILLES. CONTRACTOR IS TO PLACE LOCATION C )IFFUSER5 AND RETURN AIR GRILLES AS REQUIRED BY CODE, 5. HVAC THERMOSTAT I iATIONS: POSITION LOCATION OF ALL THERMOSTATS WHERE A ROPRIATE PER MECHANICAL DESIGN. COORDINATE WITH TEN IT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CON) -,TS. 6. DESIGN/BUILD ELECT :AL: ELECTRICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE EIS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LII ED i0 ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DE\ ES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXIST i ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACT i IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS R UIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMP WITH ALL APPLICABLE CODES. 7. ELECTRICAL CODE C IPLIANCE: COMPLY WITH THE INDIANA ELECTRICAL AND Ni UCAL CODE AND ALL OTHER APPLICABLE CODES. 8. ELECTRICAL CIRCUITING: SIZE AND CIRCUIT ELECTRICAL POWER ITEMS PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. 9. GFI OUTLETS: ALL ELECTRICAL OUTLETS WITHIN 6' 0" OF WATER ARE TO BE G.F.C.I. 10. PHONE AND DATA ACCOMMODATIONS: AT EACH PHON E AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. 11. ELECTRICAL SWITCH PLATES: PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCH PLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 12. WORK STATION POWER: PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN. REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BOXES. 13. LIGHTING CIRCUITS: VERIFY EXISTING LIGHTING CIRCUITING. SIZENEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUTOF LIGHT FIXTURES. 14. ELECTRICAL OUTLETS: ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS. 15. LIGHTING SWITCH PLATES: WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 16. LIGHT FIXTURE PLACEMENT: CENTER CEILING ELEMENTS IN CEI LING TILES, INCLUDING RECESSED DOWNLIGHTS, SMOKE DEFECTORS, SPRINKLER HEADS. AND EXIT SIGNS UNLESS OTHERWISE NOTED. 17. EMERGENCY LIGHTING: PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED i0 AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 18. FIRE ALARM SYSTEM: PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHI N SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. TECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANTINSTALLEDITEMS I.E. PRESENTATION BOARDS, A V EQUIPMENT AND PROJECTION SCREENS). 21. EXISTING LIGHT FIXTURE IIIIF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTI N G 5 PACES. CONSULT WITH LANDLORD. 22. HVAC CONTRACTOR AIR BALANCE: CONTRACTOR TO PERFORM AIR BALANCE UPON COMPLETION OF HVAC SCOPE. PROVIDE REPORTTO LANDLORD. 23. HVAC FLEX DUCT FLEX DUCT MUST MEET ASHRAE STAN CARD BUILDING CODES FOR FLEX DUCT LENGTH. 24. ELECTRICAL CIRCUITS: AREAS WITHIN ELECTRICAL SCOPE MUST BE POWERED BY THE ELECTRICAL PANEL FROM THE FLOOR ON WHICH CONSTRUCTION OCCURS. 25. SUPPLEMENTAL HVAC/ELECTRICAL: IN THE EVENT THAT ANY SUPPLEMENTAL HVAC EQUIPMENT OR ABOVE BUILDING STANDARD ELECTRICAL POWER FACILITIES ARE INSTALLED (SUCH AS IN AN IT SERVER ROOM) CONTRACTOR SHOULD FURNISH AND INSTALL ADDITIONAL ELECTRICAL AND BTU SUB -METERING SO AS TO ENABLE OWNER TO MONITOR TENANT'S UTILITY CONSUMPTION (IN RELATION i0 THE SUBJECT EQUIPMENT) GOING FORWARD. THE MAKE AND MODEL OF CONTRACTOR'S PROPOSED METERS SHOULD BE REVIEWED AND APPROVED BY OWNER PRIOR TO CONTRACTOR INSTALLATION. 26. ENGINEERED MEP DRAWINGS: WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTOR(5) SHALL PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR FIRE SUPPRESSION. DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW. 27. EQUIPMENT INSTALLATIONS: ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 28. BUILDING DIRECTORY: THE BUILDING AUTOMATION SYSTEM GRAPHIC AND PROGRAMMING TO BE UPDATED WITH NEW TENANT'S INFORMATION FOR FUTURE USE. 29. ELECTRICAL PANELS: ALL ELECTRICAL PANELS TO GET UPDATED CIRCUIT SCHEDULES. FIRE PROTECTION NOTES I. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEEF FROM ANV POINT i0 A VISIBLE EXTINGUISHER, 2. DESIGN BUILD FIRE PROTECTION SYSTEM: FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UN DER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM, SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 3. FIRE PROTECTION SYSTEM CODE COMPLIANCE: THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE IN DIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY i0 DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 4. FIRE PROTECTION DESIGN DRAWINGS: THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AN D LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. SPRINKLER HEADS: PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. DOCUMENT APPROVAL 2. DECONSTRUCTION MANAGEMENT CHECKLIST: ALL ITEMS SHOWN ON THE DECONSTRUCTION PLAN HAVE BEEN CAREFULLY CONSIDERED FOR RECOVERY, REUSE, AND RECYCLING WITH THE BEST INTENTTO DIVERT ITEMS FROM THE LANDFILL. REFER TO DECONSTRUCTION MANAGEMENT CHECKLIST FOR SPECIFIC INSTRUCTIONS. 3. RECYCLING: GENERAL CONTRACTOR 15 RESPONSIBLE FOR RECYCLING ANY AND ALL POSSIBLE PROJECT MATERIAL WASTE AND COORDINATING THE APPROPRIATE HAULING CONTAINERS WITH THE WASTE MANAGEMENT 5UB-CONTRACTOR. 4. EXISTING STRUCTURAL ELEMENTS OF BUILDING: NO STRUCTURAL OR LOAD -BEARING CONSTRUCTION SHALL BE REMOVED DEMOLISHED OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS DURING DEMOLITION CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD -BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT i0 OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR NADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 5. EQUIPMENT, FIXTURE, FINISH REUSE: WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY N ECE55ARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIREC"' 6. DECONSTRUCTION PO :REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATE) Y NOTE, SYMBOL, OR DASHED LINES. NOTE THAT SOME ITEMS HAVE P ' BEEN SHOWN ON DECONSTRUCTION PLAN. VISIT AREA OF WO TO ASSURE EXTENT OF DECONSTRUCTION. 7. FIELD VERIFICATION OI {ISTING CONDITIONS: REMOVE ALL CARPET, VINYL BASE, VCI TALL FABRIC, AND ANY OTHER FINISHES REQUIRED FOR NEW CON AUCTION. CONTRACTOR TO FIELD V EXISTING CONDITIONS. R iR TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISYt FINISHES i0 REMAIN. 8. PROTECTION OF BUILD : ELEMENTS TO REMAIN: Ll' rRETO PROTECT EXISTING BUILDII ELEMENTS INDICATED' CIE DRAWINGS TOREMAIN RE SUPPSUCH AS BUT Ji LIMITED iF E%ISi _NLTURES, D TILES, FIRESUPPRESSIONS JD FINISHES. TFER' RA FIXTURES EQUIPMENT, CASEWORK, !D FINISHES. TN' ,NTRACTORSHALL REPLACE AND/OR REPAIF ,i THE CONTR OR'5 COST, ANY SUCH ELEMENTS DAMAGED DUI G CONST" iON THAT COULD HAVE OTHERWISE BEEN REASON ILY PRO- cD AND MAINTAINED IN GOOD CONDITION FOR OWI , USE IN THE PROJECT. 9. REMOVALOFABANDC _c BLING&WIRING: PER THE INDIANA "`^'"'^"'^^^"`^^" r FIRE OR PRODUCTS OF COMBUSTION) LL , OPTIONS OF ABANDONED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES. REFER TO SECTION 300.21. ANY SUCH CABLE OR WIRING SHOULD BE PULLED AND REMOVED BACK TO THEIR MAIN SOURCES ON THE FLOOR (I E. ELECTRICAL PANELS, PHONE BOARDS, ETC.) 10. PROTECTION OF ABANDONED/TERMINATED BUILDING SYSTEM ELEMENTS: WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN "AS-BUI LT' SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 11. HAZARDOUS MATERIALS: GENERAL CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ANY AND ALL ITEMS THAT MAY CONTAIN HAZARDOUS OR HARMFUL MATERIALS. ALL IDENTIFIED ITEMS MUST BE PROPERLY DISPOSED OF PER EPA AND INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT RULES AND REGULATIONS. 12. COSTS: GENERAL CONTRACTOR i0 PROVIDE ANY COST RELATED TO SORTING AND RECYCLING, AS WELL AS ALL SCRAP METAL INCOME AS PART OF THE DEMOLITION/DECONSTRUCTION BASE BID. 13. RECEIPTS: GENERAL CONTRACTOR MUST OBTAIN AND PROVIDE TO OWNER RECEIPTS ON ALL RECYCLED ITEMS INCLUDING CREDIT FOR METALS, TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. TENANT/CLIENT COMPANY NAME I IgJdR183g93�i:RIG\I11i9[.7Jc\Ip 7i1gJcTN83g93sjgN/_\IL7i9 7INIgHJcn4 ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT, THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOTTS) BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. ./CASEWORK NOTES DRK/MILLORK: CASEWORK AND MILLWORK GENERALLY ON WIN v A O THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERENERi :ONTRACT. 2. AWIIJ IMPLIANCE: UNLESS INDICATED OTHERWISE, COMPLYWITH ARCHIII TURAL WOODWORK INSTITUTE(A.W.I.) CURRENT STANDARDS FOR CIIII )M GRADE WOODWORK. 3. MILL' IRK SHOP DRAWINGS: FURNISH SHOP DRAWINGS ON ALL MILLWC AND CASEWORK FORAPPROVAL BVTHETENANTAND SCHOU :SIGN PRIORTO FABRICATION. 4. MILL' IRK FIELD VERIFICATION: WHERE RK AND MILLWORK CASEWORK O AREINSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSNS JS OF AS -BUILT CONDITIONS IN FIELD. REPORT ANY DISCREI aCIES TO SCH07 DESIGN THROUGH THE GENERAL CONTR. TOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT ) CONDITIONS UNLESS DOI NG SO WILL SIGNIFICANTLY ALTER THE INTI OF THE DESIGN SHOWN ON THE DRAWINGS. 5. DRA' IG REVIEW AND DISCREPANCIES: VERIFY FINISHES (LAMINATE VENEER AINS,ETC.) ON THE SECTIONS AND ELEVATION DRAWINGS WITH FP BEE INDICATED ON THE FINISH PLAN/SCHEDULES. MMEDI PLY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROW THE GENERAL CONTRACTOR. 6. MILL' IRK REQUIREMENTS: REFER TO MILLWORK SECTIONS& ELEVATI IS. UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD, COUNT OPS WITH 4" BACKSPLASHES WHERE INDICATED. BACK5F 5HE5 TO BE FIELD APPLIED. REFER TO MILLWORK SECTIONS& ELEVATI IS FOR CABINETRY SPECIFICATIONS(CUSTOM PLASTIC LAMINA OR PRE- MANUFACTURED STOCK CABINETRY). EDGES OF PLASTIC kMINATE COUNTERTOPS, CABINETS AN D DRAWERS TO BE PLASTIC %MINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS )TED OTHERWISE. m JRK WALL BLOCKING: i0 PROVIDE BLOCKING IN WALLS FOR A��LLWORK, WALL STOPS, HARDWARE, AND CABINETRY WHERE -CIFIED. ALL WOOD BLOCKING TO BE FIRE RATED. 1.9 ^... �..�... 9 mmi T ;f. T 9 St. t. VICINITY MAP NOT TO SCALE 1ST FLOOR 2ND FLOOR KEY PLANS N N OT TO SCALE INDEX OF DRAWINGS TIII COVERSHEET AND GENERAL PROJECT NOTES L 100 LIFE SAFETY PLAN AIII DECONSTRUCTION PLAN/ ARCHITECTURAL FLOOR PLAN A121 REFLECTED CEILING PLAN / ELECTRICAL PLAN A131 FINISH PLAN A211 DOOR SCHEDULE/ INTERIOR DETAILS o THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DEIGN, INC., AND ARE NOTTO BE )SED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. LLM In Z N N O r Z_Q `r o z Z - C) QLJJ V J � LlJ W � UJ WOQ =U Q N N L- ISSUE DATE DESCRIPTION D5.22.19 PERMITSET REVISIONS MARK DATE I DB DESCRIPTION AR10700017 STATE OF MOW PROJECT NUMBER 2018.519 PROD. MGR DRAWN BY AS AS COVER SHEET AND GENERAL NOTES T111