HomeMy WebLinkAboutA111 Architectural Floor PlanDECONSTRUCTION LEGEND EXISTING TO BE REMOVED EXISTING TO REMAIN WALL — WALL mmmmmm PARTIAL HEIGHT WALL ' T DOOR AND FRAME WINDOW / SIDELIGHT D-----C CEILING GRID AND rTILETILES, 5, 2'x4' CEILING GRID AND rTILES, 2'x2' F N I N. SUPPLY AIR DIFFUSERS cam ca —l1 LIGHT FIXTURE, RL __ Ja FLUORESCENT, 2'x4' IF-1 LIGHT FIXTURE, LJ _ FLUORESCENT, 2'x2' X( LIGHT FIXTURE, CAN FYFr+ LIGHT FIXTURE, TRACK )ZH LIGHT FIXTURE, SCONCE LIGHT FIXTURE, PENDANT $ LIGHTSWITCH F4y^ EXIT LIGHT =' -e ELECTRIC OUiLEi(SI gvDil i DATA OR b COMMUNICATION OUTLET � PARTIAL HEIGHT WALL 77 DOOR AND FRAME x WINDOW/SIDELIGHT NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. 1ST FLOOR RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Calmed (� �NI��V'�O+n4:YTAMI_ DATE: 06/21/19 DECON. GENERAL NOTES I. REFER TO ALL DECONSTRUCTION NOTES ON 717LESHEETT I II, 2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR BUILDING IF POSSIBLE. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER TO THE DECONSTRUCTION MANAGEMENT CHECKLIST BELOW. 3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. 4. SALVAGE EXISTING LIGHTING TRACK FOR POSSIBLE REUSE; SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. DECON, PLAN NOTES D01 REMOVE EXISTING CABINETRY AND COUNTERTOP. D02 REMOVE EXISTING SINK. NO SERVICE SINKS ARE BEING REMOVED. D03 REMOVE EXISTING SCONCE LIGHT. PATCH AND REPAIR WALL AS REQUIRED AND PREP TO RECEIVE NEW FINISHES. 8 EXISTING LIGHT FIXTURE TO BE SALVAGED AND DELIVERED TO SCHOTT DESIGN FOR STORAGE. DOS EXISTING SCONCE LIGHT FIXTURE TO BE SALVAGED FOR REUSE. SEE REFLECTED CEILING PLAN FOR NEW LOCATION(S), DO6 REMOVE EXISTING UNUSED WATER METER AT THIS LOCATION; PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. 00] EXISTING PLUMBING FIXTURES AND RE37ROOM ACCESSORIES TO REMAIN UNLESS NOTED OTHERWISE. DECONSTRUCTION MANAGEMENT CHECKLIST THIS CHECKLIST ONLY APPLIES TO ITEMS BEING REMOVED. REFER TO DECONSTRUCTION PLAN. CONTAINER: ITEM BEING z a z REMARKS REMOVED a+ G E Q } Q U6 U 3 rcU DOORS ✓ FRAMES ✓ DOOR HARDWARE ✓ DECORATIVE LIGHTING SALVAGE (7) 24" DIAMETER PENDANTS FROM 2ND FLOOR PER NOTE D04; CONTRACTOR TO DELIVER TO SDI FOR STORAGE CASEWORK ✓ CARPET ✓ GENERAL SORTING REQUIREMENTS (AS APPLICABLE): CO -MINGLE RECYCLING CONTAINER: SHIPPING/PACKAGING, WOOD STUDS, WOOD TRIM, HVAC COMPONENTS, CEILING GRID, METAL STUDS, WIRING/ CONDUIT, AND OUTLETS/SWITCHES WASTE CONTAINER: DRYWALL,INSULATION, VINYL BASE AND LVT(LUXURY VINYL TILE) CONTACTS: KRUSE CARPEF RECYCLING: COORDINATE WITH SUSAN SHAFER (317)337-1950 2ND FLOOR DECONSTRUCTION PLANS 0 2' 4' 8' 16' LLI_t - WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BEE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT GREEN BOARD AS REQUIRED IN RESiROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. E WALL WITH INSULATION 3S/g" METAL STUDS AT 16 O.C.; ONE LAYER OF S% TYPE "X' GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL R PARTIAL HEIGHT WALL - 35/8" METAL STUDS AT 16" O.C.; ONE LAYER OF S/e" TYPE "X" GYPSUM BOARD EACH SIDE: EXTEND WALL TO 6-0 WITH WITH DRYWALL WRAPPED TOP CAP; PROVIDE I" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED R PARTIAL HEIGHT WALL 3s/8 METAL STUDS AT 16" O.C.; ONE LAYER OF 5/e" TYPE "X" GYPSUM BOARD EACH SIDE: EXTEND WALL TO 3'-4Y2'; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED PLAN NOTES A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. OA02 PROVIDE PLYWOOD PHONE BOARD, 4'x8'xi', PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. A03 NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR, ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. A04 PROVIDE 3'-0'W X8'-0"H WINDOW WITH}"TEMPERED GLASS AND TIMELY BLACK FRAME, CENTERED IN WALL. TOP OF WINDOW TO ALIGN WITH TOP OF ADJACENT DOOR FRAMES. A05 PROVIDE S'-OW X8'-0"H WINDOW WITH}"TEMPERED GLASS AND TIMELY BLACK FRAME, CENTERED IN WALL, TOP OF WINDOW TO ALIGN WITH TOP OF ADJACENT DOOR FRAMES. A06 COORDINATE WALL THICKNESS AND FRAMING WITH POCKET DOOR. �] PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. AOB PROVIDE APPROXIMATELY I'-6"DX8'-0"W LIVE EDGE WOOD COUNTER INSTALLED AT 42" ALL WITH INDUSTRIAL PIPE SUPPORTS AS REQUIRED. PROVIDE SHOP DRAWINGS TO SDI FOR APPROVAL PRIOR TO ORDERING. A09 PROVIDE FULL HEIGHT WOOD WRAP AT CORNER OF WALL UTILIZING RECLAIMED WOOD, APPROXIMATELY 8'X8". DESIGN INTENT IS FOR WRAP TO APPEAR AS BEAM, NO VINYL BASE AT THESE LOCATIONS. WOOD SPECIES AND STAIN TO BE DETERMINED AND APPROVED BY TENANT. A10 EXISTING OPENING TO BE INCREASED TO ALLOW FOR NEW 3'-0"W WINDOW WITH 'TEMPERED GLASS AND TIMELY BLACK FRAME, A71 EXTEND EXISTING WALL TO DRYWALL CEILING. Al2 PROVIDE 6'-8" X 1'-2" QUARTZ (QZI ) TRANSACTION TOP ON PARTIAL HEIGHT WALL WITH CONCEALED SUPPORTS BEHIND DRYWALL AS REQUIRED. P01 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING, P02 PROVIDE WATER LINE FOR COFFEE AND/OR REFRIGERATOR. CONFIRM LOCATION WITH TENANT. P03 PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT PROVIDED DISHWASHER AND/OR ICE MAKER. 1ST FLOOR ARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN W? WALL =zzzzzz_ WALL PARTIAL HEIGHT WALL ® PARTIAL HEIGHT WALL ® �u WINDOW/SIDELIGHT >~a WINDOW/SIDELIGHT DOOR AND FRAME (SEE DOOR SCHEDULE) 77 DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. }"TEMPERED GLASS WINDOW IN TIMELY FRAME, FINISH: BLACK (TYP.) „n a n PARTIAL HT, WALL DETAIL 2ND FLOOR ARCHITECTURAL PLANS 0 2' 4' 8' 16' .� N V coo THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. mi Li 0 Z N N C�I1+O Z� 0 II— Q Lu J L L-1 CL LU �OQ =U Q N N R— SSUE DATE DESCRIPTION DS.22.19 PERMITSET REVISIONS ARK DATE I DES DESCRIPTION NO. AR10700017 STATE OF PROJECT NUMBER 2018.519 PROD. MGR DRAWN BY AJ A3 mm DECONSTRUCTION/ ARCHITECTURAL FLOOR PLAN A111