HomeMy WebLinkAboutA111 Architectural Floor PlanDECONSTRUCTION LEGEND
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL — WALL
mmmmmm PARTIAL HEIGHT WALL
' T DOOR AND FRAME
WINDOW / SIDELIGHT
D-----C CEILING GRID AND
rTILETILES,
5, 2'x4'
CEILING GRID AND
rTILES, 2'x2'
F N
I
N.
SUPPLY AIR DIFFUSERS
cam ca
—l1
LIGHT FIXTURE,
RL __ Ja
FLUORESCENT, 2'x4'
IF-1
LIGHT FIXTURE,
LJ _
FLUORESCENT, 2'x2'
X(
LIGHT FIXTURE, CAN
FYFr+
LIGHT FIXTURE, TRACK
)ZH LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
PENDANT
$ LIGHTSWITCH
F4y^ EXIT LIGHT
=' -e ELECTRIC OUiLEi(SI
gvDil i
DATA OR
b COMMUNICATION
OUTLET
� PARTIAL HEIGHT WALL
77 DOOR AND FRAME
x WINDOW/SIDELIGHT
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
1ST FLOOR
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Calmed (�
�NI��V'�O+n4:YTAMI_
DATE: 06/21/19
DECON. GENERAL NOTES
I. REFER TO ALL DECONSTRUCTION NOTES ON 717LESHEETT I II,
2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT
OR BUILDING IF POSSIBLE. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER TO THE DECONSTRUCTION
MANAGEMENT CHECKLIST BELOW.
3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE
FOR NEW FINISHES AS REQUIRED.
4. SALVAGE EXISTING LIGHTING TRACK FOR POSSIBLE REUSE; SEE REFLECTED CEILING PLAN FOR MORE INFORMATION.
DECON, PLAN NOTES
D01 REMOVE EXISTING CABINETRY AND COUNTERTOP.
D02 REMOVE EXISTING SINK. NO SERVICE SINKS ARE BEING REMOVED.
D03 REMOVE EXISTING SCONCE LIGHT. PATCH AND REPAIR WALL AS
REQUIRED AND PREP TO RECEIVE NEW FINISHES.
8
EXISTING LIGHT FIXTURE TO BE SALVAGED AND DELIVERED TO
SCHOTT DESIGN FOR STORAGE.
DOS EXISTING SCONCE LIGHT FIXTURE TO BE SALVAGED FOR REUSE. SEE
REFLECTED CEILING PLAN FOR NEW LOCATION(S),
DO6 REMOVE EXISTING UNUSED WATER METER AT THIS LOCATION;
PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED.
00] EXISTING PLUMBING FIXTURES AND RE37ROOM ACCESSORIES TO
REMAIN UNLESS NOTED OTHERWISE.
DECONSTRUCTION MANAGEMENT CHECKLIST
THIS CHECKLIST ONLY APPLIES TO ITEMS BEING REMOVED. REFER TO DECONSTRUCTION PLAN.
CONTAINER:
ITEM BEING
z
a z
REMARKS
REMOVED
a+
G E
Q }
Q
U6
U
3
rcU
DOORS
✓
FRAMES
✓
DOOR HARDWARE
✓
DECORATIVE LIGHTING
SALVAGE (7) 24" DIAMETER PENDANTS FROM 2ND FLOOR PER NOTE D04;
CONTRACTOR TO DELIVER TO SDI FOR STORAGE
CASEWORK
✓
CARPET
✓
GENERAL SORTING REQUIREMENTS (AS APPLICABLE):
CO -MINGLE RECYCLING CONTAINER: SHIPPING/PACKAGING, WOOD STUDS, WOOD TRIM, HVAC COMPONENTS,
CEILING GRID, METAL STUDS, WIRING/ CONDUIT, AND OUTLETS/SWITCHES
WASTE CONTAINER: DRYWALL,INSULATION, VINYL BASE AND LVT(LUXURY VINYL TILE)
CONTACTS:
KRUSE CARPEF RECYCLING: COORDINATE WITH SUSAN SHAFER (317)337-1950
2ND FLOOR
DECONSTRUCTION PLANS
0 2' 4' 8' 16'
LLI_t -
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BEE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT GREEN BOARD AS REQUIRED IN
RESiROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
E WALL WITH INSULATION
3S/g" METAL STUDS AT 16 O.C.;
ONE LAYER OF S% TYPE "X' GYPSUM BOARD
EACH SIDE; EXTEND WALL TO UNDERSIDE OF
CEILING; FIBERGLASS SOUND BATT
INSULATION INSIDE WALL
R PARTIAL HEIGHT WALL -
35/8" METAL STUDS AT 16" O.C.;
ONE LAYER OF S/e" TYPE "X" GYPSUM BOARD
EACH SIDE: EXTEND WALL TO 6-0 WITH
WITH
DRYWALL WRAPPED TOP CAP;
PROVIDE I" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED
R PARTIAL HEIGHT WALL
3s/8 METAL STUDS AT 16" O.C.;
ONE LAYER OF 5/e" TYPE "X" GYPSUM BOARD
EACH SIDE: EXTEND WALL TO 3'-4Y2';
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED
PLAN NOTES
A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
OA02 PROVIDE PLYWOOD PHONE BOARD, 4'x8'xi', PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
A03 NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
CONTRACTOR, ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10.
A04 PROVIDE 3'-0'W X8'-0"H WINDOW WITH}"TEMPERED GLASS AND
TIMELY BLACK FRAME, CENTERED IN WALL. TOP OF WINDOW TO
ALIGN WITH TOP OF ADJACENT DOOR FRAMES.
A05 PROVIDE S'-OW X8'-0"H WINDOW WITH}"TEMPERED GLASS AND
TIMELY BLACK FRAME, CENTERED IN WALL, TOP OF WINDOW TO
ALIGN WITH TOP OF ADJACENT DOOR FRAMES.
A06 COORDINATE WALL THICKNESS AND FRAMING WITH POCKET DOOR.
�] PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
AOB PROVIDE APPROXIMATELY I'-6"DX8'-0"W LIVE EDGE WOOD
COUNTER INSTALLED AT 42" ALL WITH INDUSTRIAL PIPE SUPPORTS
AS REQUIRED. PROVIDE SHOP DRAWINGS TO SDI FOR APPROVAL
PRIOR TO ORDERING.
A09 PROVIDE FULL HEIGHT WOOD WRAP AT CORNER OF WALL
UTILIZING RECLAIMED WOOD, APPROXIMATELY 8'X8". DESIGN
INTENT IS FOR WRAP TO APPEAR AS BEAM, NO VINYL BASE AT
THESE LOCATIONS. WOOD SPECIES AND STAIN TO BE DETERMINED
AND APPROVED BY TENANT.
A10 EXISTING OPENING TO BE INCREASED TO ALLOW FOR NEW 3'-0"W
WINDOW WITH 'TEMPERED GLASS AND TIMELY BLACK FRAME,
A71 EXTEND EXISTING WALL TO DRYWALL CEILING.
Al2 PROVIDE 6'-8" X 1'-2" QUARTZ (QZI ) TRANSACTION TOP ON
PARTIAL HEIGHT WALL WITH CONCEALED SUPPORTS BEHIND
DRYWALL AS REQUIRED.
P01 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE
OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING,
P02 PROVIDE WATER LINE FOR COFFEE AND/OR REFRIGERATOR.
CONFIRM LOCATION WITH TENANT.
P03 PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT
PROVIDED DISHWASHER AND/OR ICE MAKER.
1ST FLOOR
ARCHITECTURAL LEGEND
NEW CONSTRUCTION
EXISTING TO REMAIN
W?
WALL
=zzzzzz_
WALL
PARTIAL HEIGHT WALL
®
PARTIAL HEIGHT WALL
®
�u
WINDOW/SIDELIGHT
>~a
WINDOW/SIDELIGHT
DOOR AND FRAME
(SEE DOOR SCHEDULE)
77
DOOR AND FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
GENERAL NOTES
I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
}"TEMPERED GLASS WINDOW IN
TIMELY FRAME, FINISH: BLACK (TYP.)
„n
a
n PARTIAL HT, WALL DETAIL
2ND FLOOR
ARCHITECTURAL PLANS
0 2' 4' 8' 16'
.�
N
V
coo
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
mi
Li
0
Z
N
N
C�I1+O
Z�
0
II—
Q
Lu
J
L L-1
CL
LU
�OQ
=U
Q
N
N
R—
SSUE
DATE
DESCRIPTION
DS.22.19
PERMITSET
REVISIONS
ARK DATE I DES DESCRIPTION
NO.
AR10700017
STATE OF
PROJECT NUMBER
2018.519
PROD. MGR DRAWN BY
AJ A3
mm
DECONSTRUCTION/
ARCHITECTURAL
FLOOR PLAN
A111