Loading...
HomeMy WebLinkAboutA121 Electrical - Reflected CeilingELECTRICAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLEL DUPLEX POWER OUTLEL DUPLEX .q, POWER OUTLEL POWER OUTLEL QUADRUPLEX QUADRUPLEX J JUNCTION BOX J JUNCTION BOX OCEILING MOUNTED CEILING MOUNTED JUNCTION BOX JUNCTION BOX ® BOX, BLANK COVER PLATE ® BOX, BLANK COVER PLATE Q BOX, OPEN 0 BOX, OPEN P PROVIDE JUNCTION BOX P POWER AND DATA POLE D ABOVE CEILING FOR D POWER POLE CONNECTION, POWER POLE BY OTHERS. FLOOR BOX WITH POWER FLOOR BOX WITH POWER �p AND DATA, FLUSH AND DATA, FLUSH MOUNTED MOUNTED FLOOR BOX WITH FLOOR BOX WITH (J)p JUNCTION BOX AND J b JUNCTION BOX AND DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED DATA/COMMUNICATION DATA/COMMUNICATION 11 OUTLET (PROVIDE BOX p OUTLET AND PULL STRING ONLY( DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42" HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL PLAN NOTES E01 NO ELECTRICAL WORK IN THIS AREA. E02 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT, E03 PROVIDE FLUSH MOUNT FLOOR CORE WITH POWER AND DATA; CONFIRM EXACT LOCATION AND REQUIREMENTS WITH TENANT. E04 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 24"A.F.F. E05 CONFIRM EXISTING POWER LOCATION CAN BE REUSED FOR DISHWASHER; PROVIDE NEW POWER AS REQUIRED. E06 ALL ABOVE COUNTER OUTLETS ARE FOR DEDICATED APPLIANCE USE ONLY, CONVENIENCE OUTLETS ARE LOCATED ELSEWHERE IN ROOM, 1ST FLOOR RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Ca el DATE: 06/21/19 GENERAL ELEC. NOTES I. TENANTS FUR MT URE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A. F.F. TOTH E CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANTS SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PUNS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. RCP LEGEND NEW OR RELOCATED �( SPECTRUM LIGHTING: SP415"RECESSED LED DOWNLIGHT, FINISH: MATTE BLACK MANS GLOBE LIGHTING: 10229 PENDANT ® BB® BRONZE WITH FINISH IL R TH q ARCHIPELAGO U FIGHTING : VINTAGE RCH EDISON ST19 LAMPS ®TRANS GLOBE LIGHTING : PND-1083 B PENDANT FINISH WEATHEREDBRONZE(WB) WITH ARCHIPELAGO UGHTNG: VINTAGE RCH RADIO EDT 0 LAMPS ®BARNLIGHT: WESCO CORD HUNG LED C PENDANT LIGHT, 20DIAMETER. FINISH: 100 BLACK, STANDARD BLACK CORD, 2700K BROWNLEE LIGHTING : 2600 LED PENDANT, ®D FINISH: BLACK(BL). DIFFUSER: WOVEN BLACI (WBK1, CC1 SUSPENSION INDUSTRIAL LIGHTW ORKS: 1 SUGHT RECLAIMED WOOD. FLUSH MOUNT, BLACK PLASTIC CORD GRIP, BLACK CORD, BLACK SOCKET, LED MIX BULBS MACK LIGHT: REUSE EXISTING (RACK SALVAGED FROM DEMOLITION AND PAINT (PTQ. TRACK HEADS: W AC LIGHTING - LUCB 6022, COLOR: BLACK, COLOR TEMP: 2700K 04 BARNLIGHT: STATIC RING LED TRIPLE VANITY LIGHT, FINISH: 100 BLACK, STRAIGHT ARM, NO GLASS, WITH ARCHIPELAGO LIGHTING VINTAGE RCH RADIO RD10 LAMPS NL INDICATES NIGHT LIGHT LOCATION EMERGENCY LIGHT FIXTURE EXISTING TO REMAIN 411 EXITUGHT/EMERGENCY LIGHT COMBO $N UGHTSWITCH V LIGHT SWITCH $N3 LIGHT SWITCH, 3-WAY $3 LIGHT SWITCH, 3-WAY $ND LIGHT SWITCH, DIMMER VD LIGHT SWITCH, DIMMEe $NP SWITCH, PROJECTOR SCREEN $P PROJECTOR SCREEN $NG SWITCH, GARBAGE DISPOSAL VG SWITCH, GARBAGE DISPOSAL i — LIGHT CIRCUIT —\ LIGHT CIRCUIT CEUNG GRID, SUSPENDED, 2'x2' GYPSUM BOARD CEILING SU i� CEILING GRID, SUSPENDED, 2'x2' ❑ DIFFUSER, LAWN, 2'x2' O DIFFUSER NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW, NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. GENERAL NOTES I. EXISTING DRYWALL CEILING TO REMAIN AND BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH. ALL EXISTING EXPOSED DUCT WORK AND DIFFUSERS TO BE PAINTED (PT4). 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILU RE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. S. NEW DEVICES AND FACE PLATES TO MATCH EXISTING WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS, ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES, 1ST FLOOR LoL LoL LoL MECHANICAL NOTES I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS, NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT, NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, RCP PLAN NOTES R01 CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. R02 PROVIDE NEW BLACK 2'X2' V6' CEILING GRID AND BLACK ARMSTRONG DUNE LAY -IN CEILING TILE Ai 10'-0"AFF, CENTERED IN ROOMASSHOWN. INSTALL SCONCE LIGHT FIXTURES SALVAGED FROM DEMOLITION R03 AT THIS LOCATION (PREVIOUS SCONCE LOCATIONS(. REMOVE GLASS GLOBE AND PROVIDE NEW ARCHIPELAGO LIGHTING, VINTAGE RCH RADIO RDIO LAMP. RO4 PROVIDE 25" DEEP DRYWALL BULKHEAD TO EXTEND FROM TOP OF CABINETS TO DRYWALL CEILING. HORIZONTAL FACE OF BULKHEAD TO BE PAINTED (PT3( AND VERTICAL FACE(S) OF BULKHEAD TO BE PAINTED (PTI). ROS PROVIDE 16'LO" X I I'-0" CEILING CLOUD WITH BLACK 2'X2' 5f6" CEILING GRID AND BUCK ARMSTRONG DUNE _AY -IN CEILING TILE CENTERED IN CLOUD AT 9' 0 AFF. EDGE TRIM TO BE 6" ARMSTRONG AXIOM, FINISH: BLACK. RELOCATE DIFFUSERS & MECHANICAL DIFFUSER RELOCATION 'RFFFR TO MFCHANICAI NOTFS FOR FIIRTHFR INFORMATION 2ND FLOOR REFLECTED CEILING PLAN 0 2' 4' 8' 16' V coo THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUTTHE WRBTEN CONSENT OF SCH07 DESIGN. mi Li 0 N N O z LLLLLLLLLL� C) Q � — W J L LJ LU CL LU WOQ =U 0 N PROJECT NUMBER 2018.519 PROD. MGR DRAWN BY AS AS ELECTRICAL PLAN/ REFLECTED CEILING PLAN Al 21