HomeMy WebLinkAboutA121 Electrical - Reflected CeilingELECTRICAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLEL DUPLEX
POWER OUTLEL DUPLEX
.q,
POWER OUTLEL
POWER OUTLEL
QUADRUPLEX
QUADRUPLEX
J
JUNCTION BOX
J
JUNCTION BOX
OCEILING
MOUNTED
CEILING MOUNTED
JUNCTION BOX
JUNCTION BOX
®
BOX, BLANK COVER PLATE
®
BOX, BLANK COVER PLATE
Q
BOX, OPEN
0
BOX, OPEN
P
PROVIDE JUNCTION BOX
P
POWER AND DATA POLE
D
ABOVE CEILING FOR
D
POWER POLE
CONNECTION, POWER
POLE BY OTHERS.
FLOOR BOX WITH POWER
FLOOR BOX WITH POWER
�p
AND DATA, FLUSH
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
(J)p
JUNCTION BOX AND
J b
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
DATA/COMMUNICATION
11
OUTLET (PROVIDE BOX
p
OUTLET
AND PULL STRING ONLY(
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42"
HEIGHT OF ELECTRICAL
OR DATA DEVICE
ELECTRICAL PLAN NOTES
E01 NO ELECTRICAL WORK IN THIS AREA.
E02 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT,
E03 PROVIDE FLUSH MOUNT FLOOR CORE WITH POWER AND DATA;
CONFIRM EXACT LOCATION AND REQUIREMENTS WITH TENANT.
E04 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
24"A.F.F.
E05 CONFIRM EXISTING POWER LOCATION CAN BE REUSED FOR
DISHWASHER; PROVIDE NEW POWER AS REQUIRED.
E06 ALL ABOVE COUNTER OUTLETS ARE FOR DEDICATED APPLIANCE
USE ONLY, CONVENIENCE OUTLETS ARE LOCATED ELSEWHERE IN
ROOM,
1ST FLOOR
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Ca el
DATE: 06/21/19
GENERAL ELEC. NOTES
I. TENANTS FUR MT URE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A. F.F. TOTH E CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANTS SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PUNS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
RCP LEGEND
NEW OR RELOCATED
�( SPECTRUM LIGHTING: SP415"RECESSED LED
DOWNLIGHT, FINISH: MATTE BLACK
MANS GLOBE LIGHTING: 10229 PENDANT
® BB® BRONZE WITH FINISH IL R TH
q
ARCHIPELAGO
U FIGHTING : VINTAGE RCH
EDISON ST19 LAMPS
®TRANS GLOBE LIGHTING : PND-1083
B PENDANT FINISH WEATHEREDBRONZE(WB)
WITH ARCHIPELAGO UGHTNG: VINTAGE
RCH RADIO EDT 0 LAMPS
®BARNLIGHT: WESCO CORD HUNG LED
C PENDANT LIGHT, 20DIAMETER. FINISH: 100
BLACK, STANDARD BLACK CORD, 2700K
BROWNLEE LIGHTING : 2600 LED PENDANT,
®D FINISH: BLACK(BL). DIFFUSER: WOVEN BLACI
(WBK1, CC1 SUSPENSION
INDUSTRIAL LIGHTW ORKS: 1 SUGHT
RECLAIMED WOOD. FLUSH MOUNT, BLACK
PLASTIC CORD GRIP, BLACK CORD, BLACK
SOCKET, LED MIX BULBS
MACK LIGHT: REUSE EXISTING (RACK
SALVAGED FROM DEMOLITION AND PAINT
(PTQ. TRACK HEADS: W AC LIGHTING - LUCB
6022, COLOR: BLACK, COLOR TEMP: 2700K
04 BARNLIGHT: STATIC RING LED TRIPLE VANITY
LIGHT, FINISH: 100 BLACK, STRAIGHT ARM,
NO GLASS, WITH ARCHIPELAGO LIGHTING
VINTAGE RCH RADIO RD10 LAMPS
NL INDICATES NIGHT LIGHT LOCATION
EMERGENCY LIGHT FIXTURE
EXISTING TO REMAIN
411 EXITUGHT/EMERGENCY
LIGHT COMBO
$N
UGHTSWITCH
V
LIGHT SWITCH
$N3
LIGHT SWITCH, 3-WAY
$3
LIGHT SWITCH, 3-WAY
$ND
LIGHT SWITCH, DIMMER
VD
LIGHT SWITCH, DIMMEe
$NP
SWITCH, PROJECTOR SCREEN
$P
PROJECTOR
SCREEN
$NG
SWITCH, GARBAGE DISPOSAL
VG
SWITCH, GARBAGE
DISPOSAL
i —
LIGHT CIRCUIT
—\
LIGHT CIRCUIT
CEUNG GRID,
SUSPENDED, 2'x2'
GYPSUM BOARD
CEILING
SU
i� CEILING GRID,
SUSPENDED, 2'x2'
❑ DIFFUSER, LAWN, 2'x2' O DIFFUSER
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW, NO NEW HVAC
DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
GENERAL NOTES
I. EXISTING DRYWALL CEILING TO REMAIN AND BE PAINTED BRIGHT
CEILING WHITE, FLAT FINISH. ALL EXISTING EXPOSED DUCT WORK AND
DIFFUSERS TO BE PAINTED (PT4).
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILU RE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS,
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL
BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
NEED TO BE MET.
4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
S. NEW DEVICES AND FACE PLATES TO MATCH EXISTING WHERE
POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON
PLAN.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS, ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES,
1ST FLOOR
LoL LoL LoL
MECHANICAL NOTES
I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS, NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT, NO NEW HARD DUCTWORK OR
EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES,
RCP PLAN NOTES
R01 CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT
THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
R02 PROVIDE NEW BLACK 2'X2' V6' CEILING GRID AND BLACK
ARMSTRONG DUNE LAY -IN CEILING TILE Ai 10'-0"AFF, CENTERED IN
ROOMASSHOWN.
INSTALL SCONCE LIGHT FIXTURES SALVAGED FROM DEMOLITION
R03 AT THIS LOCATION (PREVIOUS SCONCE LOCATIONS(. REMOVE
GLASS GLOBE AND PROVIDE NEW ARCHIPELAGO LIGHTING,
VINTAGE RCH RADIO RDIO LAMP.
RO4 PROVIDE 25" DEEP DRYWALL BULKHEAD TO EXTEND FROM TOP OF
CABINETS TO DRYWALL CEILING. HORIZONTAL FACE OF BULKHEAD
TO BE PAINTED (PT3( AND VERTICAL FACE(S) OF BULKHEAD TO BE
PAINTED (PTI).
ROS PROVIDE 16'LO" X I I'-0" CEILING CLOUD WITH BLACK 2'X2' 5f6"
CEILING GRID AND BUCK ARMSTRONG DUNE _AY -IN CEILING TILE
CENTERED IN CLOUD AT 9' 0 AFF. EDGE TRIM TO BE 6"
ARMSTRONG AXIOM, FINISH: BLACK.
RELOCATE DIFFUSERS &
MECHANICAL DIFFUSER RELOCATION
'RFFFR TO MFCHANICAI NOTFS FOR FIIRTHFR INFORMATION
2ND FLOOR
REFLECTED CEILING PLAN
0 2' 4' 8' 16'
V
coo
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUTTHE WRBTEN
CONSENT OF SCH07 DESIGN.
mi
Li
0
N N
O
z
LLLLLLLLLL�
C)
Q � —
W J
L LJ
LU
CL LU
WOQ
=U
0
N
PROJECT NUMBER
2018.519
PROD. MGR DRAWN BY
AS AS
ELECTRICAL PLAN/
REFLECTED
CEILING PLAN
Al 21