HomeMy WebLinkAboutA002.0FINISHED BASEMENT PLAN1/4" = 1'-0"
FINISHED BASEMENT
UNEXCAVATED
EGFI
4040 SL w/ EGRESS HARDWARE
2/8
TO SWITCH ABOVE
BEDROOM
MECH/STORAGE
W.I.C.
2/8\pxql;110V W/ BAT.\PBACKUP\PINTERCONNECTED
CHANGE TO CAN\PLIGHT WHEN CAN\PPACKAGE IS CHOSEN
\A1;14'-0"
\A1;14'-5{\H0.750000x;\S1#2;}"\A1;9'-7{\H0.750000x;\S1#2;}"
\A1;20'-0"
\A1;3'-4{\H0.750000x;\S1#2;}"
\A1;6'-5{\H0.750000x;\S1#2;}"
\A1;5'-2{\H0.750000x;\S3#4;}"\A1;5'-5{\H0.750000x;\S1#2;}"\A1;6'-4"
\A1;8'-8{\H0.750000x;\S1#2;}"\A1;9'-0"
8'-0" CLG. \PCARPET
EGRESS WITH 9'-0" POUR OPTION SEE PROJECT MANAGER FOR DETAIL
\A1;13'-11{\H0.750000x;\S1#2;}"
STANDARD HIGH EFFICIENCY FURNACE LOCATION VERIFY W/ MECHANICAL PLANS
POWER VENT W.H.
EJECTOR PIT AND PUMP \PFIELD VERIFY LOCATION W/PROJECT MANAGER. \PPROVIDE DEDICATED 110V OUTLET AS SHOWN
UP 16R
\A1;3{\H0.750000x;\S1#2;}"
\A1;6'-11"
\A1;10'-8{\H0.750000x;\S1#4;}"\A1;3'-5{\H0.750000x;\S3#4;}"
2/42/4
\A1;5'-0"
2/4STORAGE
\A1;16'-9"
\A1;6'-0"
2/4
VENT TO EXTFAN / LT.TBTP
1R/1S.
\A1;7{\H0.750000x;\S1#2;}"\A1;4'-9"
\A1;14'-0{\H0.750000x;\S1#2;}"
CH
\A1;5'-0"
\A1;3'-4"
\A1;6'-0"
\A1;13'-5{\H0.750000x;\S1#2;}"
\A1;8'-8"
\A1;23'-0"
\A1;2'-0"
\A1;9'-7{\H0.750000x;\S1#2;}"
GAS SUPPLYFD
BEAM & POST PER STRUCT
BEAM & POST PER STRUCTBEAM & POST PER STRUCT
BEAM & POST PER STRUCT
BEAM & POST PER STRUCT
4040 SL w/ EGRESS HARDWARE
EGRESS WITH 9'-0" POUR OPTION SEE PROJECT MANAGER FOR DETAIL
121311109
653421
78
1415
RAISED BAR TOP
\A1;6"
\A1;4'-4"
\A1;1'-0"
\A1;4'-4{\H0.750000x;\S1#2;}"
\A1;1'-0"
\A1;5'-7"
HALF WALL
5' PLATFORM\PUP 12"
5' PLATFORM\PUP 6"
THEATER
GYM8'-0" CLG. \PRUBBER FLOOR
MIRROR WALL
2/4CH
STO.
1R/1S.TPBATH
VENT TO EXTFAN / LT.
BATH
\A1;4'-4"
\A1;6"
\pxql;12" DRP. HDR.
\A1;1'-0"
\A1;13'-0"\A1;1'-4{\H0.750000x;\S1#2;}"\A1;16'-4"\A1;1'-0"\A1;1'-0"\A1;17'-6"\A1;1'-0"\A1;13'-6{\H0.750000x;\S1#2;}"
\A1;4'-9"\A1;5'-8{\H0.750000x;\S1#2;}"
\A1;3'-2{\H0.750000x;\S1#2;}"
\A1;3'-0"
\A1;2'-2{\H0.750000x;\S1#2;}"
\A1;5'-0"
\A1;5'-0"
\A1;12'-7{\H0.750000x;\S1#2;}"
\A1;15'-2"
\A1;15'-1"
\A1;8{\H0.750000x;\S1#2;}"
\A1;5'-0"SHOWER
S
TVPH
S S3
GFI
SS S
S
S PHTV
S3
S
S
S3S3
S
GFI
SS
PLAN NAME
SHEET
COMMUNITY NAME
PRODUCTION MANAGER
LAWSON COMMUNITY ID
RELEASE DATE:DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME
SPECIFICATION LEVEL
GARAGE HANDING
REV #
PROJECT TYPE
CURRENT
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
ARCHITECT OF RECORD:ENGINEER OF RECORD:
12/12/2018Joel Hampshire
(c) Copyright PulteGroup, Inc. - 2011
Indiana Division11590 N. Meridian St, Suite 530Carmel, Indiana 46032SINGLE FAMILY
West Clay
LOT 323
----
GARAGE LEFT
Red
Plan 5
1815.0000
--
5271
MULHERN & KULPGODUCO DESIGN - ARCHITECTS
PLOTTED: March 6, 2019 / Annie Lee / PLAN-5271-IN-WCLY-PLAN.DWG 1--2--3--4--------------------------
PLOTTED: March 6, 2019 / Annie Lee / PLAN-5271-IN-WCLY-PLAN.DWG Finshed Basement Plan2.00a
06/16/19
William Hohlt