HomeMy WebLinkAbout`(•� DUKE
ENERGY
June 6, 2019
K.WEERTS @LILLIY.COM
I
RE: Demolition of Property at 931 Oswego Rd. Carmel, IN 46032
To Whom- It May Concern,
This letter= is to inform you that all electric service and meter to the :above referenced.
property have- been removed as of June. 6, 2019
Should. you have any further :questions please feel free to contact our office at 311-896
6703.
Sincerely,
Mindy Brackin
Sr. Work Management Specialist
Carmel District Office
NVectren Energy Delivery
16000 Allisonville Road
i
P.O. Box 1700
Noblesville, IN 46061
June 10, 2019
Attn: K.WEERTS@LILLY.COM
WO MAXIMO 16859758 93'1 OSWEGO RD CARMEL IN
As per your.' request, this letter confirms that Vectren has checked our active retired files at the above
address. I also checked with Dispatch and the- confiirmed:t6e same thing: .
Provided the demolition:activities are restricted to the area, where the -structure is located, you should be -
able to proceed with the demolition Without interference to Vectren Energy. Delivery distribution lines,
Please contact ILIPPS-at :1-800-382-5544 locations of other buried utilities that might be in _the area.
If I can be of further assistance, concerning this matter, please contact meat 317-776-5544.
My `fax number is 317-776-5554
]OE BARC
Field Supervisor .
I Noblesville
AIR
4404 N. Franklin Rd.
Indianapolis, IN 46226
(317) 546-7473
FAX: (317) 546-1272
May 29, 2019
C"W'ph,con
Jim Arthur
Casey Bertram Construction
5780 East 25th Street
Indianapolis, IN 46218
Re: Asbestos Inspection
931 Oswego Road.
Dear Mr. Arthur:
Asbestos .Inspections & Removal Company (AIR Co.) is pleased to. present the findings of the
asbestos inspection performed by Daniel Flack (license# 190206048� expires- April 06; 2020) at
the vacant residence located at 931 Oswego Road in Carmel. The house is a one-story structure
constructed over a full -basement with brick exterior siding.
Samples of -following suspect asbestos materials were collected and submitted -to Micro Air; Inc.
:for analysis by Polarized Light Microscopy, (PLM) with Dispersion Staining using EPA-600-M4-
-82-020 & EPA Method/600/R-93/116 (1993).
Drywall Ceiling Texture _Popcorn
�. Wall Texture • : Loose Fill Insulation - brown
Fiberboard Ceiling • Loose Fill .Insulation white
• Acoustic; Ceiling Tile
According to laboratory analysis, none:of the sampled materials contain asbestos.
Asphalt roofing materials: and resilient floor coverings were assumed -to contain asbestos and not
sampled. These materials are category I non -friable materials which do not need to be removed
unless subjected to -sanding, grinding, abrading, burning or any. other activity which will crumble,
pulverize, or reduce the material to a powder.
We appreciate the opportunity to provide. our asbestos services and look forward to :assisting you
in the future. If you have any questions- or require additional information, please contact us. at
(317) 546-7473.
Sincerely,
Wayne IGrelle
Vice President
i
U,
May 28, 2019
AIR Co.
Dan Flack
4404 North Franklin Road
Indianapolis, IN 46226
i
Indoor Air Quality
Catastrophe Services
6320 LA PAS TRAIL, NDIANAPOLIS, INDIANA 46268
Microbiology
Asbestos Surveys
TELEPHONE: (317) 293-1533 FAX: (317) 290-3569
Air Monitoring
Industrial Hygiene
E-MAIL: microair@m�croair.com
Epidemiology
Rados Testing
WEB SITE: wvvw.micloair.com
Water Testing
Lead Testing
RE: Polarized Light Microscopy (PLM) Bulk Sample Results
Project Name:
Project Number:
Dear Mr_ Flack:
Casey; Vacant House Location: 931 Oswego
19-272 Date Received: May 23, 2019
Enclosed is(are) the result(s) of the analysis performed on the sample(s), received by Micro Air, Inc.
Method of Analysis:
Polarized Light Microscopy (PLM) with Dispersion Staining using EPA-600-M4-82-020 & EPA Method/600/R-
93/116 (1993). All samples may be heated to release fibrous material.
Negative PLM results of non -friable organic bound (NOB) materials, such as floor tiles and roofing materials, can be
inconclusive due to analytical difficulties in standard bulk sample analysis techniques. If desired, negative results can
be confirmed with transmission electron microscopy (TEM) to ensure that asbestos has not been missed during PLM
analysis.
Asbestos regulations and EPA methods state that distinct layers must be analyzed and reported separately. If composite
analysis is requested and performed on multi -layered samples, the sample is considered asbestos containing material
(ACM) if any quantity of asbestos is found.
This report may not be reproduced, except in full, without written approval from Micro Air, Inc., and only relates to the
items tested. This report should not be used to imply product or service endorsement by NVLAP or any agency of the
U.S. Government.
If you have any questions concerning this report please do not hesitate to contact us.
Sincerely,
1-7
Betsie L. McAfee
Technical Manager
AIHA Laboratory ID No. 100951 NVLAP Lab Code 101221-0 * ISDH Certificate No. M-49-5
Page 1 of 3
micro air, inc.
6320 La Pas Trail Client: AIR Co. ®
Indianapolis, IN 46268 Project Number: 19-272 �� O
Telephone: (317) 293-1533 Project Name: Casey; Vacant House
Fax: (317) 290-3566 Report Date: 5/28/2019 TESTING
e-mail: microair@microair.com Lab Number: 126155 ANItPi'R� [OPF101771.0
Website: www.microair.com Date Received: 5/23/2019
Polarized Light Microscopy (PLM) Bulk Sample Results
Location: 931 Oswego
Sample
1D
Client
Sample ID
Date
Collected
Date
Analyzed
Sample Description
Asbestos
Present?
Color
homogeneous
Sample Composition
Asbestos Non -Asbestos
001
01
5/22/2019
5/24/2019
Drywall
NO
W-G
YES
N/A
Cellulose 2%
Binder 98%
002
02
5/22/2019
5/24/2019
Wall Texture
NO
W
YES
N/A
Cellulose <I %
Binder 100%
003
03
5/22/2019
5/24/2019
Fiberboard Ceiling
NO
O-W
YES
N/A
Cellulose 100%
004
04
5/22/2019
5/24/2019
ACT
NO
O
YES
N/A
Cellulose 100%
00.5
05
5/22/2019
5/24/2019
Popcorn Ceiling Texture
NO
W
YES
N/A
Cellulose <I%
Binder 100%
Page 2of3
Client: AIR Co. Project Number: 19-272
Report Date: 5/28/2019 Project Name: Casey; Vacant House
Lab Number: 126155
Polarized Light Microscopy (PLM) Bulk Sample Results
Location: 931 Oswego
Sample.
ID
Client
Sample ID
Date
Collected
Date
Analyzed
Sample Description
Asbestos
Present?
Color
Homogeneous
Sample Composition
Asbestos Non -Asbestos
006
06
5/22/2019
5/24/2019
Brown Loose Fill
NO
BR
YES
N/A
Cellulose 100%
007
07
5/22/2019
5/24/2019
White Loose Fill
NO
W
YES
N/A
Cellulose <1%
Binder 100%
A concentration of greater than one (1) percent of any type of asbestos means a sample meets the EPA definition of an asbestos -containing material
Color: B-Black, BL-Blue, BR -Brown, GL-Gold, G-Gray, GR-Green, O-Orange, P-Pink, PR -Purple, R-Red, S-Silver, T-Tan, W-White, Y-Yellow
Deanna French has reviewed this final report.
Sample(s) received in good condition and acceptable.
Analyst: Darren A. Parsons
Analytical Method: EPA Method 600-M4-82-020 & EPA Method 600-R-93-116 (1993)
Page 3 of 3