HomeMy WebLinkAboutC504 - UTILITY PLAN (POND)FFE = 868.50 FFE = 868.50 T 112' WIDE EMERGENCYSPILLWAYW/ RIP RAPREVETMENT COVER PROPOSED 15' ESMT (TYP)NO PARKINGNO PARK I N G NO PARK I N GNO PARKING 1.REFER TO MECHANICAL, ELECTRICAL AND PLUMBING PLANS FOR CONTINUATION OF UTILITIES WITHIN 5 FEET OF STRUCTURES. 2.PRESSURE UTILITY MAINS AND SERVICE LINES MAY NEED TO BE INSTALLED AT A DEPTH GREATER THAN THAT SPECIFIED OR SHOWN ON THE DRAWINGS TO CLEAR EXISTING AND PROPOSED CROSSING UTILITIES. IN SUCH CASES, THE CONTRACTOR SHALL INSTALL VERTICAL BENDS AS REQUIRED TO ACHIEVE APPROPRIATE CLEARANCE BETWEEN THE CROSSING UTILITIES. 3.A MINIMUM HORIZONTAL SEPARATION OF 10 FEET BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT ALL TIMES. A MINIMUM VERTICAL SEPARATION OF 18 INCHES BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT CROSSINGS. IN THE EVENT THAT MINIMUM SEPARATION REQUIREMENTS CANNOT BE MET, THE CONTRACTOR SHALL UTILIZE PRESSURE-TYPE WATER PIPE FOR THE SEWER PER DETAIL SA-9. 4.WATER MAINS SHALL BE INSTALLED WITH A MINIMUM OF 54 INCHES OF COVER AS MEASURED FROM THE TOP OF THE PIPE TO THE FINAL FINISH GRADE ABOVE THE PIPE. 5.THRUST BLOCKS OR JOINT RESTRAINTS SHALL BE INSTALLED ON ALL WATER LINES AT ALL BENDS, TEES AND HYDRANTS PER THE DETAILS. 6.WHERE WATER FITTINGS ARE REQUIRED, DUCTILE IRON (DI) FITTINGS SHALL BE USED. FITTING JOINTS SHALL BE OF STANDARD MJ TYPE (ANSI/AWWA C111/A21.11) OR PJ TYPE (ANSI/AWWA C111/A21.11). 7.DI FITTINGS SHALL CONFORM TO ANSI/AWWA C110/A21.10, 350 PSI AND SHALL BE CEMENT MORTAR LINED PER ANSI/AWWA C104/A21.4 AND SHALL BE OUTSIDE COATED WITH A BITUMINOUS COATING. 8.PIPE LENGTHS SHOWN ARE MEASURED FROM CENTER TO CENTER OF STRUCTURES ROUNDED TO THE NEAREST FOOT. UTILITY NOTES 9.PIPE LENGTHS SHOWN FOR STORM SEWERS ARE MEASURED TO THE DOWNSTREAM END OF END SECTIONS. 10.WHERE GRADE MODIFICATIONS (CUT OR FILL) ARE SHOWN ADJACENT TO EXISTING VALVE BOX COVERS AND MANHOLE CASTINGS, THE VALVE BOX COVERS AND MANHOLE CASTINGS SHALL BE ADJUSTED FLUSH WITH THE PROPOSED GRADE. 11.ADJUSTMENTS OF EXISTING MANHOLE CASTINGS TO GRADE TO A MAXIMUM OF 12 INCHES SHALL BE MADE USING PRECAST CONCRETE ADJUSTING RINGS PROVIDED THE TOTAL HEIGHT OF EXISTING AND NEW ADJUSTING RINGS DOES NOT EXCEED 12 INCHES. 12.ADJUSTMENTS OF CASTINGS WHERE THE TOTAL HEIGHT OF ADJUSTING RINGS WOULD EXCEED 12 INCHES SHALL BE MADE BY REPLACING THE CONE AND/OR BARREL SECTION OF THE STRUCTURE. 13.PAVEMENTS, WALKS, CURBS AND OTHER SURFACE IMPROVEMENTS REQUIRING REMOVAL FOR INSTALLATION OF UNDERGROUND UTILITIES SHALL BE RESTORED TO THEIR PRESENT CONDITION UNLESS OTHERWISE SHOWN. 14.ALL INLET CASTINGS LOCATED WITHIN ASPHALT PAVEMENT AREAS SHALL INCLUDE A CONCRETE PAVED COLLAR EXTENDING A MINIMUM OF 24 INCHES IN ALL DIRECTIONS FROM THE EDGE OF THE CASTING PER THE DETAILS. 15.THE CONTRACTOR SHALL MAINTAIN ALL FLOWS AND UTILITY CONNECTIONS TO EXISTING BUILDINGS, ETC. WITHOUT INTERRUPTION UNLESS/UNTIL AUTHORIZED TO DISCONNECT BY THE OWNER, UTILITY COMPANIES, AND GOVERNING AUTHORITIES. THE CONTRACTOR SHALL INSTALL AS NECESSARY, TEMPORARY SITE LIGHTING, GAS, SANITARY, WATER, STORM, ELECTRIC, TELEPHONE, AND CABLE SERVICES TO SERVICE BUILDING(S) TO REMAIN OPEN. 16.CONTRACTOR TO PROVIDE SLEEVES UNDER FOOTINGS OR THROUGH FOUNDATIONS FOR UTILITY CONNECTIONS. 17.CONTRACTOR SHALL PROVIDE ALL BENDS, FITTINGS, ADAPTERS, ETC. AS REQUIRED FOR PIPE CONNECTIONS TO BUILDING/CANOPY STUB OUTS. INCLUDING ROOF/FOOTING DRAIN CONNECTIONS TO ROOF LEADERS AND TO STORM DRAINAGE SYSTEM. 18.CONTRACTOR TO PROVIDE AND INSTALL CONDUIT FOR SITE LIGHTING PER SITE LIGHTING PLAN (BY OTHERS). 19.CONTRACTOR TO PROVIDE AND INSTALL CONDUIT FOR IRRIGATION PER IRRIGATION PLAN (BY OTHERS). 20.CONTRACTOR WILL BE RESPONSIBLE TO REPAIR, REPLACE, AND/OR RECONNECT ANY EXISTING DRAINAGE TILES NOT SHOWN ON THE PLANS, WHICH CROSS THROUGH EXCAVATED TRENCHES. ANY DRAINAGE TILE ENCOUNTERED IS TO BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND A MEASUREMENT TAKEN FROM THE NEAREST MANHOLE OR INLET STRUCTURE TO THE CENTERLINE OF THE TILE. 21.MANHOLE AND INLET CASTINGS LOCATED WITHIN ASPHALT PAVEMENT AREAS SHALL INCLUDE A CONCRETE PAVED COLLAR EXTENDING A MINIMUM OF 24 INCHES IN ALL DIRECTIONS FROM THE EDGE OF THE CASTING PER THE DETAILS. 22.SUBSURFACE DRAIN (SSD) INLET CONNECTIONS SHALL BE INCLUDED ON ALL STORM INLETS AND SHALL BE SET 24 INCHES BELOW THE CASTING ELEVATION UNLESS OTHERWISE SPECIFIED. THE SSD'S SHALL BE 10 LF. AND SLOPE 1.04% TOWARD THE INLET CREATING AN 'X' PATTERN BELOW THE CASTING ELEVATION. FFE = 868.50 WWWWWWGT HW 100: 855.8 NORMAL: 851.0FHV4"6"DOMFIREW W P WLatLatLatLatLatLatLat6" C.O. C.O. C.O. C.O. C.O.RDRDRDC.O. RD C.O. RD C.O.RDC.O. C.O.RDRDRDC.O. C.O. C.O. RD RDC.O.C.O. C.O. OUTDOOR MECHANICAL YARD 150' LF OF 10" HDPE 75' LF OF 10" HDPE 57' LF OF 10" HDPE 61' LF OF 10" HDPE 160' LF OF 10" HDPE 116' LF OF 10" HDPE 136' LF OF 10" HDPE 57' LF OF 12" HDPE 110' LF OF 12" HDPE 110' LF OF 12" HDPE655 lL.F. OF 6" PVC SANITARY LATERALAT 1.04% SLOPECONCRETE COLLAR REQUIRED BETWEEN BOT. OF STORM AND TOP OF WATER AND GAS LINES. C.O. C.O. 721 RIM=865.25 720 RIM=865.10 732 RIM=865.00 718 RIM=865.00 731 RIM=865.00 705 RIM=864.00 709 RIM=864.00 710 RIM=864.00 716 RIM=863.20 717 RIM=863.20 715 RIM=862.70 704A RIM=858.04 701 RIM=855.50 714 FES 701A RIM=853.44 703 RIM=856.85 702 FES 721B RIM=864.50 134' OF 12" PVC @0.25% 22 2 ' O F 1 2 " P V C @ 0 . 2 5 % 446' OF 12" PVC @0.25% 22 3 ' O F 1 2 " P V C @ 0 . 2 5 % 126' OF 24" RCP @1.21% 60' OF 15" RCP 309' OF 18" RCP @0.58% 174' OF 36" RCP @0.52% 144' OF 36" RCP @0.54% 12' OF 42" RCP @0.49% 184' OF 42" RCP @0.51% 368' OF 42" RCP @0.49% 156' OF 42" RCP @0.48% 100' OF 24" RCP @0.65% 95' OF 24" RCP @0.63% 124' OF 12" RCP @1.93% 91' OF 12" RCP @1.21% 16' OF 24" RCP @1.17% 3 0 9 ' O F 1 5 " R C P@1 . 1 7%216' OF 24" R C P @0.60 % 68' OF 18" RCP @1.17% 391' OF 18" RCP @0.56% 144' O F 3 6 " R C P @0.54 %77' OF 12" RCP@1.36%NYLOPLAST DRAIN BASIN NYLOPLAST DRAIN BASIN NYLOPLAST DRAIN BASIN NYLOPLAST DRAIN BASIN NYLOPLAST DRAIN BASIN NYLOPLAST DRAIN BASIN 112' WIDE EMERGENCY SPILLWAY W/ RIP RAP REVETMENT COVER PROPOSED 15' ESMT (TYP)SILVARA COURTDOMIN O D RI V E WWWWWWWWWWWRETENTION BASIN W6 W5 NO P A R KI N G S1 W1 T1 AQUASWIRL AS-10 E2 E3 W6 W - WATER / FIRE PROTECTION S - SANITARY SEWER 6" PVC SANITARY LATERAL @ 1.04% MIN. SLOPE. FIRE HYDRANT FIRE DEPARTMENT CONNECTION (COORDINATE WITH MEP PLANS) 8-INCH WATER MAIN 8-INCH PRESSURE CONNECTION (HOT TAP) TO EXISTING 16-INCH WATERMAIN 4-INCH DOMESTIC SERVICE CONNECTION (COORDINATE FINAL SIZING WITH MEP PLANS) 6-INCH FIRE SERVICE LINE 2-INCH WATER SERVICE LINE W1 W2 W3 S1 T - TELECOM FIBER OPTIC CONNECTION. COORDINATE WITH LOCAL UTILITY PROVIDER.T1 G - GAS GAS CONNECTION. COORDINATE WITH LOCAL UTILITY PROVIDER.G1 E - ELECTRIC (2) 4" CONDUITS FOR PRIMARY ELECTRIC SERVICE COORDINATE WITH DUKE TRANSFORMER TRANSFORMER PAD PER UTILITY OWNER SPECIFICATIONS. E1 E2 D - DRAINAGE / STORM SEWER 6''SSD 6''SSD D1 CONNECT OUTFALL TO EXISTING STRUCTURE 6-INCH PERFORATED HDPE SUBSURFACE DRAIN UTILITY KEY NOTE LEGEND W4 W5 W6 E3 W7 18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK SCALE: 1" = 50' KEYMAP C504 C.O. C.O. Lat PROPOSED LINETYPES LEGEND EXISTING LINETYPES LEGEND RD RD STORM SEWER CLEANOUT STORM SEWER PIPE SANITARY CLEANOUT GAS LINE ROOF DRAIN WATER LINE SWALE UNDERGROUND CABLE SUBSCRIBE DRAINS (STRUCTURES) UNDERGROUND GAS UNDERGROUND WATER AERIAL ELECTRIC UNDERGROUND ELECTRIC MIXED OR UNIDENTIFIED OVERHEAD UTILITY BOARD FENCE WROUGHT IRON FENCE BOUNDARY LINE FLOW LINE E(A)E(A) E E E OHU OHU SECTION LINE FARM FENCE INDEX CONTOUR INTERMEDIATE CONTOUR SANITARY SEWER STORM SEWER D1 C504 UTILITY PLAN (POND) 1.A MINIMUM HORIZONTAL SEPARATION OF 10 FEET BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT ALL TIMES. A MINIMUM VERTICAL SEPARATION OF 18 INCHES BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT CROSSINGS. IN THE EVENT THAT MINIMUM SEPARATION REQUIREMENTS CANNOT BE MET, THE CONTRACTOR SHALL UTILIZE PRESSURE-TYPE WATER PIPE FOR THE SEWER PER DETAIL SA-9. 2.PIPE LENGTHS SHOWN ARE MEASURED FROM CENTER TO CENTER OF STRUCTURES ROUNDED TO THE NEAREST FOOT. 3.WHERE GRADE MODIFICATIONS (CUT OR FILL) ARE SHOWN ADJACENT TO EXISTING VALVE BOX COVERS AND MANHOLE CASTINGS, THE VALVE BOX COVERS AND MANHOLE CASTINGS SHALL BE ADJUSTED FLUSH WITH THE PROPOSED GRADE. 4.FULL DEPTH GRANULAR BACKFILL SHALL BE REQUIRED UNDER AND WITHIN FIVE (5) FEET OF ALL PAVED AREAS, INCLUDING CURBS, EDGE OF PAVEMENT, AND SIDEWALKS. 5.ADJUSTMENTS OF EXISTING MANHOLE CASTINGS TO GRADE TO A MAXIMUM OF 12 INCHES SHALL BE MADE USING PRECAST CONCRETE ADJUSTING RINGS PROVIDED THE TOTAL HEIGHT OF EXISTING AND NEW ADJUSTING RINGS DOES NOT EXCEED 12 INCHES. 6.ADJUSTMENTS OF CASTINGS WHERE THE TOTAL HEIGHT OF ADJUSTING RINGS WOULD EXCEED 12 INCHES SHALL BE MADE BY REPLACING THE CONE AND/OR BARREL SECTION OF THE STRUCTURE. 7.THE CONTRACTOR SHALL MAINTAIN ALL FLOWS AND UTILITY CONNECTIONS TO EXISTING BUILDINGS, ETC. WITHOUT INTERRUPTION UNLESS/UNTIL AUTHORIZED TO DISCONNECT BY THE OWNER, UTILITY COMPANIES, AND GOVERNING AUTHORITIES. THE CONTRACTOR SHALL INSTALL AS NECESSARY, TEMPORARY SITE LIGHTING, GAS, SANITARY, WATER, STORM, ELECTRIC, TELEPHONE, AND CABLE SERVICES TO SERVICE BUILDING(S) TO REMAIN OPEN. 8.CONTRACTOR TO PROVIDE SLEEVES UNDER FOOTINGS OR THROUGH FOUNDATIONS FOR UTILITY CONNECTIONS 9.CONTRACTOR TO SET PRE-CONSTRUCTION MEETING WITH Tri Co NO MORE THAN 2 WEEKS PRIOR TO BEGINNING WORK. 10.MANHOLE OR CLEAN OUT CASTINGS MAY NEED TO BE ELEVATED AFTER FINAL GRADING TO INSURE DRAINAGE AWAY FROM STRUCTURES. MANHOLE CASTINGS IN NON-PAVED AREAS SHALL BE 0.2' ABOVE GRADE. 11.CASTING ELEVATIONS OF EITHER THE FIRST UPSTREAM OR DOWNSTREAM MANHOLE TO WHICH THE CONNECTION IS MADE SHALL BE A MINIMUM OF 1 FOOT BELOW THE FINISHED FLOOR ELEVATION. 12.CONNECTIONS OF ROOF DRAINS, SUMP PUMPS AND SOURCE CLEAR WATER SHALL BE PROHIBITED. 13.AT THE INSPECTOR'S DISCRETION, A CONCRETE CRADLE MAY BE REQUIRED FOR ALL LATERAL / UTILITY CROSSINGS. CONCRETE CRADLE IS REQUIRED WHEN VERTICAL DISTANCE BETWEEN SANITARY SEWER/LATERAL AND CROSSING UTILITY IS LESS THAN 18". 14.CONTRACTOR MUST FIELD VERIFY INVERT ELEVATIONS OF EXISTING MANHOLE PRIOR TO CONSTRUCTION. IF A VARIATION EXISTS, THEN CONTACT ENGINEER. 15.ALL STRUCTURES SHALL HAVE POURED FLOW LINES AND BENCH WALLS. THE FLOW LINES AND BENCHWALLS SHALL BE TROWELED SMOOTH AND BRUSH FINISHED. ALL BENCH WALLS SHALL EXTEND TO THE CROWN OF THE HIGHEST INFLUENT PIPE. 16.ALL SANITARY MANHOLES INSTALLED UNDER THIS CONTRACT SHALL BE AIR TESTED FOR LEAKAGE IN ACCORDANCE WITH ASTM C1244-93, STANDARD TEST METHOD FOR CONCRETE SEWER MANHOLES BY THE NEGATIVE AIR PRESSURE (VACUUM) TEST. GENERAL SANITARY UTILITY NOTES