Loading...
HomeMy WebLinkAboutC507 - PLAN AND PROFILE (STORM)PROPOSED 15' ESMT (TYP)709 RIM=864.00 704A RIM=858.04 68' OF 18" RCP @1.17% 703 RIM=856.85 STR. #702 18" PIPE END SECTION INV. IN 851.00 (18" RCP (W))STR. #704A MH 4' DIA; R-3455-CTC: 858.04INV. OUT 854.00 (18" RCP (E))STR. #701 INLET AM; R-3402-ETC: 855.50INV. OUT 845.05 (24" RCP (SE))STR. #701A MH 4' DIA.;R-1772TC: 853.44INV. IN 843.52 (24" RCP (NW))INV. OUT 843.52 (24" RCP (E)) 126' 1.21% 24" RC P STR. #703 MH 4' DIA; R-3455-CTC: 856.85INV. IN 851.80 (18" RCP (W))INV. OUT 851.80 (18" RCP (E))INV. OUT 851.00 (18" RCP)STR. #702 FLARED END SECTIONSILVARA COURTWWWWWWWW701 RIM=855.50 16' OF 24" RCP @1.17% 1 2 6 ' O F 2 4 " RC P@1 . 2 1% 701A RIM=853.44 18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK STORM SEWER PLAN STORM SEWER PROFILE ALIGNMENT 701-701A ALIGNMENT 704-702 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. GENERAL NOTES SCALE: 1" = 30' SCALE:HORZ.: 1"=30' VERT.: 1"=5' LEGEND Existing Grade New Grade Granular Backfill C507 PLAN & PROFILE (STORM) NOTE* INSTALL FULL DEPTH GRANULAR BACKFILL WHEN UTILITY IS WITHIN 5' OF PAVEMENT.