Loading...
HomeMy WebLinkAboutC513 - PLAN AND PROFILE (STORM)FFE = 868.50 FFE = 868.50 WWWWWWWWWWWWWC.O. RDRD RDRDRDRDRDRDRD SAMPLING BOX PER TRI CO STANDARDS 726A RIM=864.65 726 RIM=864.25 726B RIM=866.10 726C RIM=866.75 725 RIM=865.80 725A RIM=865.25 724 RIM=864.00 724A RIM=866.80 724B RIM=868.00 37' OF 12" RCP @3.42% 119' OF 12" RCP @1.47% 46' OF 30" RCP @0.54% 168' OF 24" RCP @0.66% 119' OF 12" RCP @1.26% 37' OF 12" RCP @2.74% 27' OF 12" RCP @3.72%162' OF 24" RCP@0.52%721B RIM=864.50 STR. #725 MANHOLE, 4' DIA.; R-1772TC: 865.80INV. IN 857.95 (24" RCP (N))INV. IN 860.75 (12" RCP (E))INV. OUT 857.95 (30" RCP (S))STR. #726 MH 5' DIA.; R-3287-10VTC: 864.25INV. IN 859.05 (24" RCP (N))INV. IN 859.50 (12" RCP (W))INV. IN 859.40 (12" RCP (NE))INV. OUT 859.05 (24" RCP (S))STR. #724 MH 5' DIA.; R-3010TC: 864.00INV. IN 857.70 (30" RCP (N))INV. IN 859.00 (12" RCP (W))INV. OUT 857.70 (30" RCP (S)) 168' 0.66% 24" RCP 46' 0.54% 30" RCP STR. #726 MH 5' DIA.; R-3287-10VTC: 864.25INV. IN 859.05 (24" RCP (N))INV. IN 859.50 (12" RCP (W))INV. IN 859.40 (12" RCP (NE))INV. OUT 859.05 (24" RCP (S)) 162' 0.52% 24" RCP STR. #727 MH 4' DIA.; R-3010TC: 865.10INV. IN 859.90 (12" RCP (W))INV. IN 860.40 (12" RCP (N))INV. IN 860.85 (12" RCP (E))INV. OUT 859.90 (24" RCP (S)) 86' 0.99% 12" RCP STR. #728 MH 4' DIA.; R-3010TC: 866.35INV. IN 861.25 (12" RCP (E))INV. OUT 861.25 (12" RCP (S)) 78' 0.64% 12" RCP STR. #729 INLET AM; R-3402-ETC: 864.55INV. OUT 861.75 (12" RCP (W))FFE = 868.50FHV WWWWWWWWWRDRDRD RDRD RDRDRD RD RD RD RD RD D D D 727B RIM=868.60 727 RIM=865.10 726A RIM=864.65 726B RIM=866.10 726C RIM=866.75 728 RIM=866.35 727A RIM=866.00 729 RIM=864.55 727D RIM=865.85 119' OF 12" RCP @1.26% 37' OF 12" RCP @2.74% 27' OF 12" RCP @3.72%162' OF 24" RCP@0.52%37' OF 12" RCP @2.74% 123' O F 1 2 " R C P @0.7 7 % 25' OF 12" RCP @3.00%86' OF 12" RCP@0.99%78' OF 1 2 " R C P @0.64%NO PARKING18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK STORM SEWER PLAN STORM SEWER PROFILE ALIGNMENT 724-726 ALIGNMENT 726-729 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. GENERAL NOTES SCALE: 1" = 30' SCALE:HORZ.: 1"=30' VERT.: 1"=5' LEGEND Existing Grade New Grade Granular Backfill C513 PLAN & PROFILE (STORM) NOTE* INSTALL FULL DEPTH GRANULAR BACKFILL WHEN UTILITY IS WITHIN 5' OF PAVEMENT.