HomeMy WebLinkAboutA100 Arch-Dim. Plan+Door ScheduleDOOR SCHEDULE
NUM.
DIMENSIONS
DOORS
FRAME
HARDWARE
SET
REMARKS
TYPE MATERIAL FINISH
TYPE MATERIAL FINISH
®
EXISTING TO REMAIN
EXISTING
TO REMAIN
I
201
3'-0'x 8'-3Cx1
DI
WOOD
MATCH
EXISTING
F1
TIMELY
MATCH
EXISTING
PS
3'-d'x B'-d'x It,
DI
WOOD
MATCH
EXISTING
FI
TIMELY
MATCH
EXISTING
PS
0
3'-0'x 8'-d'xl ,
DI
WOOD
MATCH
EXISTING
Fl
TIMELY
MATCH
EXISTING
BE, PH, KIP
04
3'-d'x B'-d'x It,
DI
WOOD
MATCH
EXISTING
FI
TIMELY
MATCH
EXISTING
PS
®
3'-0'x 8'-9'x1
Dl
WOOD
MATCH
EXISTING
Fl
TIMELY
MATCH
EXISTING
PS
®
3'-d'x8'-0"x1}"
DI
WOOD
MATCH
EXISTING
FI
TIMELY
MATCH
EXISTING
AS
SEE SCHED
D1
DOOR TYPES
OPEN
OFFICE
Cm
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
Cite d Camel
DATE: 06/25/19
T' SE�ES-�. CHEED rT
N�YI III II!�II'
F1
FRAME TYPES
FLOOR PLAN -AREA A
SCALE: 1/8"= 1'-0"
LEGEND
NEW CONSTRUCTION
WALL
W.
DOOR AND FRAME
(SEE DOOR SCH MULE)
EXISTING TO REMAIN
WALL
77 DOOR AND FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
■ AREA NOT IN CONTRACT
❑ AREA OF WORK
HARDWARE LEGEND
AF AUTOMATIC FLUSH BOLT
AL ALARM
CL CLOSER
CH COATHOOK
OR CARD READER BY TENANT(N.LC.)
DB DEADBOLT
ES ELECTRIC STRIKE BY TENANT(N.FC.)
H HOLD OPEN
KP KICK PLATE
KS KICK STOP
MFB MANUAL FLUSH BOLT ON ONE LEAF
OL OFFICE LOCKSET
PH PANIC HARDWARE/ALARM
PL PRIVACY LOCKSET
PP PUSH/PULL
PS PASSAGE LATCHSET
PV PIVOTHINGE
RL ROLLER LATCHES
SP STEPNPULL- METAL FOOT PULL, SILVER FINISH
(W W W,STEPNPULLCOM)
SL STOREROOM LOCKSET
TS TOP STRIKES
DIMENSION FLOOR PLAN -AREA B
SCALE: 1 /8" = 1'-0"
FLOOR PLAN -AREA B
SCALE: 1/8" = 1'-0"
WALL TYPES
GENERAL NOTES
NOTE:
I.
UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW
ALL PLAN DIMENSION
ARE
FROM FACE TO FACE OF FINISHED WALL.
WALLS TO BE TYPE W 2.
ALL WALLS ARE TO BE
TUNLESS
OTHERWISE NOTED,
ALL NOT ALL WTVPESL
D BELOW ARE NECESSARILY USED ON THIS
2.
PROVIDE BRACING AND FIRE- TREATED BLOCKING AS REQUIRED IN
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
WALLS SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS,
RESTROOM ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM
REQUIRING ADDITIONAL SUPPORT.
STANDARD WALL WITH INSULATION
3.
FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
2 25 GUAGE METAL STUDS AT 24"O. C.; -
-
EXISTINGFIREARE ACCORDING TO NFPA
AN
ONE LAVER OF g" TYPE "X" GYPSUM BOARD
ATEEXTIWITISHERS
OWNE/LNDLORD EXTINGUISHER
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
EACH SIDE;
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
EXTEND WALL TO THE UNDERSIDE OF THE
POINT TO A VISIBLE EXTINGUISHER.
CEILING. PROVIDE BATT SOUND INSULATION
I NSI DE WA ILL AND 2'-0" SO UN D I NSU LATI ON
4.
WRAP CO LUMNS AS TI GH FLY AS POSSIBLE UN LESS N OT®OTHFIR WISE .
EACH SIDE OF WALL ABOVE CEILING.
® STANDARD WALL
2Y2 METALSTUDSAi24"O.C.;
ONE LAYER OF % TYPE "X" GYPSUM BOARD
EACH SIDE
EXTEND WALL TO UNDERSIDE OF CEILING
WALL TO DECK
2' METAL STUDS AT 16" O.C.; - ONE LAYER OF % TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO DECK ABOVE. PROVIDE
BATIF SOUND INSULATION INSIDE WALL.
DOOR/FRAME NOTES
I. REUSE DOORS FROM DEMOLITION WHERE POSSIBLE. PROVIDE
NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER
AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING.
PRE -MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS.
2. CONTRACTOR TO VERIFY THAT NO HOLES/OPENINGS ARE IN
EXISTING DOOR DUE TO HARDWARE CHANGES. IF HOLES ARE
PRESENTTHAT WILL NOT BE FILLED IN MY NEW HARDWARE,
CONTRACTOR TO CONTACT PARALLEL DESIGN GROUP TO
CONFIRM ON HOW TO MOVE FORWARD,
3. PROVIDE NEW HARDWARE ON NEW DOORS. REUSE EXISTING
HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW
DOOR HARDWARE, PROVIDE BUILDING STANDARD. PROVIDE
A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND
LATCHSEfS.
4. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED.
REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE.
5. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL
CORNERS UNLESS OTHERWISE NOTED ON PLAN.
6. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS
AND LOCKSETS.
7. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE
SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS
CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND
ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS
MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10,
MEANS OF EGRESS.
8. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
• 7'-0'HT.TOHAVE3HINGES
• GREATER THAN 70 IN HT. TO HAVE 4 HINGES
• FINISH TO MATCH HARDWARE SET
9. PROVIDE I SET OF SILENCERS ON ALL DOORFRAMES UNLESS
OTHERWISE NOTED,
10. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH
DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING
BEHIND WALL STOP,
5. ALL DIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL UNLESS
NOTED OTHERWISE. DIMENSIONS TO EXISTING WALL ARE SHOWN TO
FACE OF EXISTING FINISH. DIMENSIONS DESIGNATED AS "CLR" OR
"CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO
FACE OF FINISH.
6. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO PARALLEL
DESIGN GROUP FOR FINAL DECISIONS.
KEYED NOTES
OALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR )IMPELS OR WHERE NEW
WALLS ARE IN LINE WITH EXISTING WALLS.
2O MICROWAVE PROVIDED BY TENANT.
(D NEW LOCATION OF RELOCATED EXISTING SEMIRECESSEDFIRE
EXTINGUISHER CABINETS.
PLACEMENT IS FOR GENERAL REFERENCE. ALL EXTINGUISH ERS
SHALL BE PLACED IN ACCORDANCE WITH NFPA 10.
4O PR OV IDE WATER LIN E FOR COFFEE AND R EFRI GERATOR.
CONFIRM LOCATION WITH TENANT.
5O PROVIDE WATER LINE FOR REFRIGERATOR AND WATER
DISPENSER. CONFIRM LOCATION WITH TENANT.
ONEW LOCATION OF EXISTING DISHWASHER, CONTRACTOR
INSTALLED. PROVIDE PLUMBING AS NEEDED.
O7 NEW LOCATION OF RELOCATED EXISTING ICE MAKER,
CONTRACTOR INSTALLED, PROVIDE PLUMBING AS NEEDED,
OPROVIDE SINGLE BOWL STAINLESS STEEL UNDER-MOUNTSINK
AND FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT
COMMERCIAL MODEL, PROVIDE PUSH BUTTON ON/OFF AT
SINK/COUNTER FOR GARBAGE DISPOSAL IN LIEU OF SW ITCH.
SINK- ELKAY, CROSSTOWN OECMU24179R
(STAINLESS STEEL)
FAUCET -DELTA, MATEO SINGLE -HANDLE PULL DOWN
#9183-AR-DST (ARCTIC STAINLESS FINISH)
PLUMBING RISER DIAGRAM
TYPICAL ALL SINGLE LOCATIONS NOTTOSCALE
2" VENT TO
`S MAIN BLDG. VENT
>I
NI
I
I
I
KEY PLAN
9;{f
F
a
5d6
y
-
m_
tu
Z
O_
Z
O
Eu
U
d
�
U
3
WE
z
Do
"
S>
OPic
o
C
nP
U
AS
DO
ro
h
OEYJ
o
0
0
rn
N
DO
3Inch
r
N
� M
o Ln
Co
N
OfT
EiiiiiiiiiiiiiiiE
Z
Oo
N
V
N
(O
Y�
CD
CD
W
= O rt
Q
O
4=•+
C
ZN
CTI a)
WIIIo
O TQd
Ln s=
v TC
C.
G
�
J
ARCH./DIM. PLAN +
DOORSCHEDULE
A100
ALLaHIGNS,CONCEPTS,APMNGEMENISMDP1 S
INDICATED OR REPRESENTED
eYMESE DRAWINGS ARE
OWNED by PARALLEL DEBI GROUP, INC AND SHALL
NOT BE USED BY OR DISCLOSED
TO ANY PERSON, FIRM
OR CORP MR ANY RGsory
WHATSOEVER WITHOUT THE
WRITTEN CONSENTOF PARALLEL DEs4ry GROUP INC.
CONTRACTORSSINLL VERIFY AND BE RESPONSIBLE ME
ALL DIMENSIONS ON THE
JOB WE. PARALLEL DEIGN
GROUPINC. MUST BE JOTTED
OF ANY DISCREPANCILE
OR WRIPNTIONS FROM THE
DIMENSIONS SHOWN ON THE
PLAN