Loading...
HomeMy WebLinkAboutCPW00035CS Beam 2018.9.0.16 kmBeamEngine 2018.9.0.1 Materials Database 1572 5-30-19 2:03pm 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Member Data Description: Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 12 PLF Deck Connection: Nailed Member Weight: 9.4 PLF Filename: Beam10 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 15' 6.00" 120 120 Snow 1 2 15 6 0 15 6 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall Not Checked N/A 1.500" 1951# -- 2 15' 6.000" Wall Not Checked N/A 1.500" 1951# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Snow Dead 1 939# 1012# 2 939# 1012# Design spans 15' 7.750" Product:1-3/4x9-1/4 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0" oc Minimum 1.50" bearing required at bearing # 1 Minimum 1.50" bearing required at bearing # 2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 7631.'# 15263.'# 49% 7.75' Total Load D+S Shear 1759.# 7074.# 24% 15.56' Total Load D+S TL Deflection 0.7283" 0.7823" L/257 7.75' Total Load D+S LL Deflection 0.3504" 0.5215" L/535 7.75' Total Load S Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% 06/24/19 David Rutti