HomeMy WebLinkAboutCPW00035CS Beam 2018.9.0.16
kmBeamEngine 2018.9.0.1
Materials Database 1572
5-30-19
2:03pm
1 of 1
All product names are trademarks of their respective owners
Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.
**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Member Data
Description: Member Type: Beam Application: Floor
Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 12 PLF Deck Connection: Nailed Member Weight: 9.4 PLF
Filename: Beam10
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 15' 6.00" 120 120 Snow
1 2
15 6 0
15 6 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall Not Checked N/A 1.500" 1951# --
2 15' 6.000" Wall Not Checked N/A 1.500" 1951# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Snow Dead
1 939# 1012#
2 939# 1012#
Design spans
15' 7.750"
Product:1-3/4x9-1/4 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
Connect members with 2 rows of 16d common nails at 12.0" oc
Minimum 1.50" bearing required at bearing # 1
Minimum 1.50" bearing required at bearing # 2
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 7631.'# 15263.'# 49% 7.75' Total Load D+S
Shear 1759.# 7074.# 24% 15.56' Total Load D+S
TL Deflection 0.7283" 0.7823" L/257 7.75' Total Load D+S
LL Deflection 0.3504" 0.5215" L/535 7.75' Total Load S
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
06/24/19
David Rutti