HomeMy WebLinkAbout19060191 Building PlansIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-1.1REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSSCALE:SITE PLAN1N3/16"=1'-0" (FULL SIZE) 3/32"=1'-0"(11x17)4'2'04'(E) 120'-0" MONOPOLE(E) FENCE(E) UTILITYFRAME(E) AT&T FEEDLINES(1) ANDREW / ATCB-B01-001 (5/16")(12) ANDREW - LDF5-50A (7/8")(4) COMMSCOPE - PWRT-606-S (7/8")(2) COMMSCOPE- RFFT-36SM-001-XXM (3/8")(E) AT&T ICE±32'-0" BRIDGE(E) DUAL SWING GATE(E) AT&T 6'-3"X15'-4"CONCRETE EQUIPMENTPAD(E) AT&T UTILITYH-FRAME (TYP.)(E) AT&T ICE±12'-0" BRIDGE(E) AT&T 6'-3"X9'-7"CONCRETE EQUIPMENTPAD(E) AT&T 6'-3"X4'-9"CONCRETE EQUIPMENTPAD(E) OTHER CARRIEREQUIPMENT SHELTER6/19/2019
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-1.2REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSSCALE:PROPOSED SITE PLAN1N1/2"=1'-0" (FULL SIZE) 1/4"=1'-0"(11x17)2'2'1'0(P) AT&T FEEDLINES TO BE INSTALLED(2) COMMSCOPE - PWRT-606-S(1) ROSENBERGER LEONI - FB-L98B-034-50(E) AT&T DC POWER PLANT & BATTERIESTO BE REPLACED (BY OTHERS)-REFER TO POWER SCOPE OF WORK(E) 120'-0" MONOPOLE(E) FENCE(E) UTILITYFRAME(E) AT&T FEEDLINES(1) ANDREW / ATCB-B01-001 (5/16")(12) ANDREW - LDF5-50A (7/8")(4) COMMSCOPE - PWRT-606-S (7/8")(2) COMMSCOPE- RFFT-36SM-001-XXM (3/8")(E) AT&T ICE±32'-0" BRIDGE(E) DUAL SWING GATE(E) AT&T 6'-3"X15'-4"CONCRETE EQUIPMENTPAD(E) AT&T UTILITYH-FRAME (TYP.)(E) AT&T ICE±12'-0" BRIDGE(E) AT&T 6'-3"X9'-7"CONCRETE EQUIPMENTPAD(E) AT&T 6'-3"X4'-9"CONCRETE EQUIPMENTPAD(E) OTHER CARRIEREQUIPMENT SHELTERPOWER SCOPE OF WORK (BY OTHERS)·INSTALL (6) NEW DROPS & BREAKERS·INSTALL NETSURE 512 & BATTERIES6/19/2019
C
B
A
A
A
A
D
C
B
A
A IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-2REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSSCALE:FINAL ELEVATION1NOT TO SCALESCALE:FINAL ANTENNA LAYOUT3NOT TO SCALENSCALE:EXISTING ANTENNA LAYOUT2NOT TO SCALEN(E) AT&T RRUs11 TO BEREMOVED FROM POSITION 3(3 TOTAL, 1 PER SECTOR)A1A2C1B1NEW AT&T SQUIDRAYCAP - DC6-48-60-18-8F(1 TOTAL)(E) AT&T SQUIDS TO REMAIN(2 TOTAL)(2) DC6-48-60-18-8FAT&T EQUIPMENTANTENNA CL: 98'-0"MOUNT CL: 97'-0"(E) 120'-0" MONOPOLE(E) AT&T EQUIPMENT TO BE REMOVED(6) ANTENNAS(3) RRUsNEW AT&T EQUIPMENT(6) ACE XXQLH-654L8H8-iVT ANTENNAS(3) RRUs4478 RRHs(3) RRUs4449 RRHs(1) RAYCAP DC6-48-60-18-8FA4B2B3B4C2C3C40°0°(E) AT&T RRUs32 B2 TO REMAININ POSITION 3(3 TOTAL, 1 PER SECTOR)(E) AT&T ANTENNAPLATFORM TO REMAINNEW AT&T RRHs MOUNT INPOSITION 3RRUS-4449 B5/B12(3 TOTAL, 1 PER SECTOR)(E) AT&T TMAs TO REMAININ POSITIONS 1 & 2(12 TOTAL, 4 PER SECTOR)A3240°240°120°120°180°(E) AT&T ANTENNA TOREMAIN IN POSITION 1 & 2(6 TOTAL, 2 PER SECTOR)(E) AT&T ANTENNA TO BEREMOVED FROM POSITION 3 & 4(6 TOTAL, 2 PER SECTOR)NEW AT&T ANTENNA INPOSITION 3 & 4ACE - XXQLH-654L8H8-iVT(6 TOTAL, 2 PER SECTOR)(P) AT&T FEEDLINES TO BE INSTALLED(2) COMMSCOPE - PWRT-606-S(1) ROSENBERGER LEONI - FB-L98B-034-50(E) AT&T FEEDLINES(1) ANDREW / ATCB-B01-001 (5/16")(12) ANDREW - LDF5-50A (7/8")(4) COMMSCOPE - PWRT-606-S (7/8")(2) COMMSCOPE- RFFT-36SM-001-XXM (3/8")60°60°180°300°300°(E) AT&T RRUs32 B66 TOREMAIN IN POSITION 4(3 TOTAL, 1 PER SECTOR)(E) AT&T RRUs32 TOREMAIN IN POSITION 4(3 TOTAL, 1 PER SECTOR)A1A2C1B1(E) AT&T SQUIDS TO REMAIN(2 TOTAL)(2) DC6-48-60-18-8FA4B2B3B4C2C3C40°0°(E) AT&T RRUs32 B2 TO REMAININ POSITION 3(3 TOTAL, 1 PER SECTOR)(E) AT&T ANTENNAPLATFORM TO REMAIN(E) AT&T TMAs TO REMAININ POSITIONS 1 & 2(12 TOTAL, 4 PER SECTOR)A3240°240°120°120°180°(E) AT&T ANTENNA TOREMAIN IN POSITION 1 & 2(6 TOTAL, 2 PER SECTOR)60°60°180°300°300°(E) AT&T RRUs32 B66 TOREMAIN IN POSITION 4(3 TOTAL, 1 PER SECTOR)(E) AT&T RRUs32 TOREMAIN IN POSITION 4(3 TOTAL, 1 PER SECTOR)NEW AT&T RRHs MOUNT INPOSITION 4RRUS-4478 B14(3 TOTAL, 1 PER SECTOR)6/19/2019
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-3REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSSCALE:FINAL ANTENNA AND COAXIAL CABLE SCHEDULE1NOT TO SCALEALPHAAZIMUTHANTENNA TYPEANTENNARADCENTERPOSITIONTECH.STATUSMECHANICALDOWNTILTELECTRICALDOWNTILT(LOW BAND/HIGH BAND)MAIN COAXSIZEMAIN COAXLENGTHCOAXQTYTMA QTYDIPLEXER QTYON TOWERRAYCAP DEMARC SQUIDDC(WR-VG86T/VG66ST-BRD)FIBER CABLES(FB-L98-002-XXX)RRHs QTYON TOWERDIPLEXERS QTYON GROUNDRET HOMERUN0°7/8"120'22°/2°98'-0"A1EXISTING120'POWERWAVERA21.7770.00-(1) RRUs-4449 B5/B12(1) RRUS-32 B20°A2BETAB1B2GAMMAC1C2RRHs QTYON GROUND-FINAL ANTENNA AND COAXIALCABLE SCHEDULENOTE: RFDS BEING USEDDATED 03/26/19 V V14GSMA3-(2) DC(1) FIBER(1)DC6-48-60-18-8F--LTEA498'-0"PROP.--(1) RRUs4478 B14(1)RRUs32 B66(1) RRUs 32-B3B4C3C4(2) POWERWAVELGP21404---ACEXXQLH-654L8H8-iVT--(2) ERICSSONKRF 102 272/1----------------------------------------------LTE98'-0"PROP.---0°7/8"120'22°98'-0"EXISTINGPOWERWAVERA21.7770.000°UMTS(2) POWERWAVELGP21404-(2) ERICSSONKRF 102 272/1-(2) ERICSSONKRF 102 272/1-(2) ERICSSONKRF 102 272/1-(2) ERICSSONKRF 102 272/1-(2) ERICSSONKRF 102 272/1----(2) DC(1) FIBER-(2) DC(1) FIBER--(1)DC6-48-60-18-8F-(1)DC6-48-60-18-8F--(2) POWERWAVELGP21404(2) POWERWAVELGP21404(2) POWERWAVELGP21404(2) POWERWAVELGP214040°7/8"120'22°/2°0°7/8"120'22°------------0°7/8"120'22°/2°0°7/8"120'22°98'-0"98'-0"98'-0"98'-0"98'-0"98'-0"98'-0"98'-0"POWERWAVERA21.7770.00POWERWAVERA21.7770.00POWERWAVERA21.7770.00POWERWAVERA21.7770.00120°120°240°240°EXISTINGPROP.PROP.EXISTINGEXISTINGPROP.PROP.EXISTINGGSMLTELTEUMTSGSMLTELTEUMTSACEXXQLH-654L8H8-iVTACEXXQLH-654L8H8-iVTACEXXQLH-654L8H8-iVTACEXXQLH-654L8H8-iVTACEXXQLH-654L8H8-iVT(1) RRUs-4449 B5/B12(1) RRUS-32 B2(1) RRUs4478 B14(1)RRUs32 B66(1) RRUs 32(1) RRUs-4449 B5/B12(1) RRUS-32 B2(1) RRUs4478 B14(1)RRUs32 B66(1) RRUs 326/19/2019
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-4.1REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSSCALE:PLUMBING DIAGRAM - SECTOR A1NOT TO SCALEFORREFERENCEONLY
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-4.2REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSSCALE:PLUMBING DIAGRAM - SECTOR B1NOT TO SCALEFORREFERENCEONLY
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-4.3REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSSCALE:PLUMBING DIAGRAM - SECTOR C1NOT TO SCALEFORREFERENCEONLY
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-5REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSSCALE:ACE - XXQLH-654-L8H8-IVT1NOT TO SCALESCALE:NOT USED6NOT TO SCALESCALE:NOT USED 5NOT TO SCALERAYCAP - DC6-48-60-18-8CSIZE: 10.24x31.41 IN.WEIGHT: 26.2 LBSNOMINAL OPERATING VOLTAGE: 48 VDCVOLTAGE PROTECTION RATING: 400 VWIND LOADING: 150 MPH SUSTAINED (105.7 LBS)WIND LOADING: 195 MPH GUST (213.6 LBS)CONTRACTOR TO USE "THREAD LUBRICANT" ON MOUNTINGBOLTS DURING INSTALLATIONRAYCAPDC6-48-60-18-8FACE - XXQLH-654-L8H8-iVTWEIGHT (WITHOUT MOUNTING HARDWARE):102.1 LBSSIZE (HxWxD): 96.0x19.6x7.8 IN.MOUNTING HARDWARE P/N: BSAMNT-1RATED WIND VELOCITY: 150.0 MPHERICSSONSCALE:ERICSSON - RADIO 4449 B52NOT TO SCALEERICSSON - RADIO 4449 B5WEIGHT: 70.0 LBSSIZE (HxWxD): 18.0x13.2x9.4 IN.ERICSSONSCALE:ERICSSON - RRUS 4478 B143NOT TO SCALEERICSSON - RRUS 4478 B14WEIGHT: 60.0 LBSSIZE (HxWxD): 15.0x13.0x8.0 IN.SCALE:RAYCAP - DC6-48-60-18-8F 4NOT TO SCALEFORREFERENCEONLY
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-1REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSSCALE:GROUNDING SCHEMATIC1NOT TO SCALESCALE:ANTENNA GROUNDING PLAN2NOT TO SCALESCALE:NOT USED3NOT TO SCALEEQUIPMENTGROUND BAREQUIPMENTCABINETEQUIPMENTGROUND BARGROUND TOTOWER GROUNDBAREQUIPMENTGROUND BARRAYCAP TOGROUND BARRRH TO GROUNDBARNEW TOP JUMPERCABLE (TYP)(E) ANTENNA PIPEMOUNTNEW SECTORANTENNANEWRAYCAPNEW FIBERJUMPER CABLE(TYP)RAYCAP TOGROUND BAR(TYP)NEW DC JUMPER(TYP)NEWRRH UNIT(E) DC CONDUCTOR(4 TOTAL)(E) SECTORANTENNA(E) ANTENNA PIPEMOUNT(E) TOP JUMPERCABLE (TYP)NEWRRH UNIT(E)RRH UNITNEWRRH UNIT(E)RRH UNIT(E) RAYCAP(E) RAYCAP(E) DC JUMPER(TYP)(E) FIBER JUMPERCABLE(TYP)(E) FIBER CONDUCTOR(1 TOTAL)NEW FIBER CONDUCTOR(1 TOTAL)NEW DC CONDUCTOR(1 TOTAL)EXISTING AT&T SECTOR GROUND BAR (TYP. OF 3SECTORS)NEW AT&T RRHs/OVPs/TMA (7 TOTAL)NEW AT&T ANTENNAS (6 TOTAL)PROVIDE GROUNDING FORRRHs,ANTENNAS,OVPs&TMAS (MECHANICALCONNECTION) TO EXISTING SECTOR GROUND BAR(USE EXISTING GROUND BAR, IF PRESENT)(SEE SHEET G-2 FOR DETAILS)EXISTING AT&T SECTOR COLLECTOR BUS BAR.EXISTING AT&T ANTENNA (6 TOTAL)EXISTING AT&T RRHs/OVPs/TMAs (23 TOTAL)1234567NOTE: EXISTING GROUNDINGNOT SHOWN FOR CLARITY25111222222673333334444446666677777777777776/19/2019
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-2REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSNOTES:1.ALL GROUNDING LUGS ARE TO BEINSTALLED PER MANUFACTURER'SSPECIFICATIONS. ALL HARDWAREBOLTS, NUTS, LOCK WASHERSSHALL BE STAINLESS STEEL. ALLHARDWARE ARE TO BE ASFOLLOWS: BOLT, FLATWASHER,GROUND BAR, GROUNDLUG, FLAT WASHER AND NUT.BURNDY GROUND LUG W/LONG BARREL(SEE CHART)BURNDY TWO HOLE LUG W/LONG BARREL(SEE CHART)BARE WIRE TO BENO-OX AT BOTH ENDSGROUNDINGCONDUCTORNUT(TYP)LOCK WASHER(TYP)BOLT(SEE CHART)(TYP)GROUND BARSTRANDED(GREEN INSULATED)ONLY FOR #6 AWG(SEE CHART)WIRE SIZE#6 AWG GREEN INSULATED#2 AWG SOLID TINNED#2 AWG STRANDED#2/0 AWG STRANDED#4/0 AWG STRANDEDYA6C-2TC38YA3C-2TC38YA2C-2TC38YA26-2TC38YA28-2N1/2" - 16 NC S 2 BOLT3/8" - 16 NC S 2 BOLT3/8" - 16 NC S 2 BOLT3/8" - 16 NC S 2 BOLT3/8" - 16 NC S 2 BOLTBURNDY LUGBOLT SIZETYPE VVTYPE GYTYPE GRTYPE VNTYPE NCTYPE VSTYPE VBTYPE SSTYPE PTNOTE:1.ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FORSPECIFIC MOLDS TO BE USED FOR THIS PROJECT.2.MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD.TYPE 2-YA-2TYPE XATYPE YA-2TYPE HSHEAT SHRINK(CLEAR)CABLE CONNECTOR(TYPICALLY)12" TO 24"120" MAX.ANTENNA CABLECABLE GROUND KITWEATHERPROOFING KIT (SEENOTE 3)NOTES:1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIREDOWN TO GROUND BAR.2.GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDEDBY CABLE MANUFACTURER.3.WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED.#6 AWG STRANDED COPPER GROUND WIRE(GROUNDED TO GROUND BAR). SEE NOTE 1 & 22 1/2"DIA. MAX.#6 AWG WEATHERPROOFINGKIT(TYP)GROUND KIT (TYP)COPPER/GALVANIZED COAXGROUND BAR BONDEDDIRECTLY TOWERRX2ANTENNA CABLETO BTS EQUIPMENT (TYP.)TX1/RX1TO ANTENNASNOTES:1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWNTO ANTENNA GROUND BAR.2.WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED.SCALE:CADWELD GROUNDING CONNECTIONS1NOT TO SCALESCALE:MECHANICAL LUG CONNECTION3NOT TO SCALESCALE:CABLE GROUND KIT CONNECTION4NOT TO SCALESCALE:GROUND CABLE CONNECTION5NOT TO SCALESCALE:GROUND BAR DETAIL7NOT TO SCALECOAX JUMPER (TYP.)CONNECTORWEATHERPROOFING KIT(TYP. SEE NOTE 2)INSULATORSSEE NOTE 2.(TYP)WALL BRACKET(TYP)TW0-HOLECOMPRESSION LUGNOTES:1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE TOWER, PER THE GROUNDINGDOWN CONDUCTOR POLICY QAS-STD-10091.NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD-WELDING ON THE TOWERAND/OR IN THE AIR ARE NOT PERMITTED.2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEELUSE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS.UNIVERSAL COPPERGROUND BAR (4"x20")LOCK WASHERP/N M10(TYP)3/8-11x1" TAMPERRESISTANT BOLT(TYP)TYPE GT²6 AWG STRANDED Cu WIRE WITHGREEN, 600V, THWN INSULATION(OR AS PROVIDED WITH GROUNDKIT) (TYP)2/0 TINNED BARECOPPER WIREEXOTHERMIC WELD (TYP)GROUND WIRENOTE 3GROUND WIRESEE NOTE 3NOTES:1.NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATIONSAND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE TOWER SHALL HAVEGROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED.2.ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE TOWERS.ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI-OXIDANT COATING.3.ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZEDEDITION OF ANSI/TIA 222 AND NFPA 780.ANTENNA GROUND BARLOCATED AT MCL(BONDED TO TOWER STEEL)2 HOLE LUG (TYP)COAX GROUND BAR WITHINSULATORS, CONNECTEDDIRECTLY TO THE BOTTOM OFMONOPOLE. SEE NOTE 1.MECHANICAL CONNECTION(TYP)MONOPOLE PIERMONOPOLE℄TO BTS EQUIPMENT VIATRAY OR ICE BRIDGECOAX CABLE(TYP FOR ALL)STANDARD COAXCABLE GROUND KIT(TYP)INSPECTION WELLTO ANTENNATO TOWER MOUNTED EQUIPMENT(TYP)SCALE:TYPICAL ANTENNA CABLE GROUNDING9NOT TO SCALENOTES:1.DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED.2.EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS.3.GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL.NOTES:1.DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED.2.EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS.3.GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL.TO ANTENNA COAXTWO HOLE LONG BARRELCOMPRESSION LUG (TYP)SCALE:ANTENNA GROUND BAR DETAIL8NOT TO SCALECOPPER/GALVANIZED GROUND BARNOTE: MINIMUM OF3 THREADS TO BEVISIBLE (TYP)2 HOLE LONGBARREL TINNEDSOLID COPPERLUG (TYP)TIN COATED SOLIDCOPPER BUS BARCHERRY INSULATORINSTALLED IF REQUIREDS/S NUT (TYP)S/S SPLITWASHER (TYP)S/S FLATWASHER (TYP)S/S FLATWASHER (TYP)S/S BOLT (TYP)*TWO HOLE LUG, OR EXOTHERMICWELD TO BE USED WITH #2 AWGBARE CONDUCTOR WIRE TOBUILDING SERVICE GROUND ORGROUND RING#6 AWG MIN. FROM ANTENNA CABLEGROUND KITGROUND BAR ON SHELTER. ICEBRIDGE, OR ON ANTENNA TOWERGROUNDING SHALLBE ELIMINATED WHENGROUND BAR ISELECTRICALLYBONDED TO METALTOWERSCALE:GROUNDWIRE INSTALLATION2NOT TO SCALESCALE:LUG DETAIL6NOT TO SCALE6/19/2019
TITLE SHEETT-1SITE PLANC-1.1C-1.2C-2C-3C-4.1C-5PROPOSED SITE PLANFINAL ANTENNA AND COAXIAL CABLE SCHEDULEFINAL ELEVATION, EXISTING & FINAL ANTENNA LAYOUTSPLUMBING DIAGRAM (REF ONLY)IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0T-1REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSG-1GROUNDING SCHEMATICLOCATION MAPNO SCALEMOUNT ANALYSIS:REFERENCE DOCUMENTS:STRUCTURAL ANALYSIS:APPLICABLE CODES/REFERENCE DOCUMENTSALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED INACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODESAS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESEPLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESECODES:CODE TYPE CODEBUILDING2015 IBC (INTERNATIONAL BUILDING CODE)MECHANICAL2015 IMC (INTERNATIONAL MECHANICAL CODE)ELECTRICAL2017 NEC (NATIONAL ELECTRICAL CODE)NOTE:PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACTTHE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTIONMANAGERPROJECT DESCRIPTIONPROJECT TEAMA&E FIRM:CROWN CASTLEUSA INC. DISTRICTCONTACTS:GPD GROUP, INC.520 S. MAIN STREET, SUITE 2531AKRON, OH 44301TRACI PREBLE - TPREBLE@GPDGROUP.COMSITE INFORMATIONCARRIER/APPLICANT:SHEET #DRAWING INDEXSHEET DESCRIPTIONALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11x17.CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONSAND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFYTHE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFOREPROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME.THE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNAMODIFICATION ON AN EXISTING WIRELESS SITE.TOWER SCOPE OF WORK·REMOVE (6) ANTENNAS @ EL 98'·REMOVE (3) RRUS-11 RRUs·INSTALL (6) ACE XXQLH-654L8H8-iVT ANTENNAS·INSTALL (3) ERICSSON RRUs4478 B14 RRHs·INSTALL (3) ERICSSON RRUs4449 B5/B12 RRHs·INSTALL (1) RAYCAP DC6-48-60-18-8F SQUID·INSTALL (2) DC TRUNK CABLES·INSTALL (1) FIBER TRUNK CABLEGROUND SCOPE OF WORK·INSTALL 5G BBUPOWER SCOPE OF WORK (BY OTHERS)·INSTALL (6) NEW DROPS & BREAKERS·INSTALL NETSURE 512 & BATTERIESGENERAL NOTEST-2CALL INDIANA ONE CALL(800) 382-5544CALL 3 WORKING DAYSBEFORE YOU DIG!RSITE PHOTOREPORT PENDING COMPLETIONAT&T SITE NUMBER:AT&T SITE NAME:AT&T FA CODE:AT&T PACE NUMBER:SITE TYPE:BUSINESS UNIT #:SITE ADDRESS:COUNTY:TOWER HEIGHT:IN0475HAZEL DELL10070790MRIND039144MONOPOLE873708HAMILTON COUNTY120'-0"10851 HAZEL DELL PKWYCARMEL, IN 46280PROJECT: AT&T LTE 6CDUKE ENERGYELECTRIC PROVIDER:TBDTELCO PROVIDER:494881CROWN CASTLE USA INC.APPLICATION ID:GROUND ELEVATION:39° 56' 54.20" -86° 04' 19.30"LATITUDE:LONGITUDE:UFACILITY IS UNMANNED AND NOT FORHUMAN HABITATIONOCCUPANCY CLASSIFICATION:A.D.A. COMPLIANCE:MAP/PARCEL #:HAMILTON COUNTYJURISDICTION:29-14-04-000-018.001-018CARMEL HAZEL DELLSITE ADDRESS:HAMILTON COUNTYCOUNTY:AREA OF CONSTRUCTION:EXISTINGNAD83LAT/LONG TYPE:511 RES-1CURRENT ZONING:PROPERTY OWNER:CCATT, LLC2000 CORPORATE DRIVECANONSBURG, PA 15317TOWER OWNER:IIBTYPE OF CONSTRUCTION:±74910851 HAZEL DELL PKWYCARMEL, IN 46280MARTIN MARIETTA MATERIALS, INCPO BOX 8040FORT WAYNE, IN 46898DESIGN PACKAGE BASEDON THE APPLICATIONID: 494881REVISION: 1DESIGN PACKAGE BASEDON THE RFDSREVISION: V14DATE: 03/26/19AT&T MOBILITY220 MERIDIAN STINDIANAPOLIS, IN 462349045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240CROWN CASTLE USA INC.SITE NAME:EQUIPMENT SPECSG-2GROUNDING DETAILSC-4.2PLUMBING DIAGRAM (REF ONLY)C-4.3NICK TALEVSKI - CONSTRUCTION MANAGER317-249-2022SITE LOCATIONPLUMBING DIAGRAM (REF ONLY)GENERAL NOTEST-3CHRIS POLICINSKI - A&E PROJECT MANAGER317-249-2024MOUNT ANALYSIS NOTES:¬7+('(6,*1'(3,&7(',17+(6('5$:,1*6,69$/,':+(1ACCOMPANIED BY A CORRESPONDING PASSING MOUNT ANALYSIS.¬&216758&7,210$1$*(5*(1(5$/&2175$&7256+$//5(9,(:THE MOUNT ANALYSIS FOR ANY CONDITIONS PRIOR TO INSTALLATION.¬$1<5(48,5('0281702',),&$7,21'(6,*12502817REPLACEMENT SHALL BE APPROVED BY EOR.REPORT PENDING COMPLETION6/19/2019
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0T-2REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSGENERAL NOTES:1.FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY:CONTRACTOR- __________SUBCONTRACTOR- GENERAL CONTRACTOR (CONSTRUCTION)CARRIER- AT&TTOWER OWNER- CROWN CASTLE USA INC.OEM- ORIGINAL EQUIPMENT MANUFACTURER2.PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TOFAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BEACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BEBROUGHT TO THE ATTENTION OF CONTRACTOR AND CROWN CASTLE USA INC.3.ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLECODES, REGULATIONS AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICESAND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANYPUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALLCOMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCALJURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS.4.DRAWINGS PROVIDED HERE ARE NOT TO SCALE AND ARE INTENDED TO SHOW OUTLINE ONLY.5.UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT,APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THEDRAWINGS.6."KITTING LIST" SUPPLIED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT WILL BE SUPPLIED BYCONTRACTOR. ITEMS NOT INCLUDED IN THE BILL OF MATERIALS AND KITTING LIST SHALL BE SUPPLIEDBY THE SUBCONTRACTOR.7.THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITHMANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE.8.IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THESUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THECONTRACTOR AND CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OFINSTALLATION.9.SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES,GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWINGS.10.THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS,LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'SEXPENSE TO THE SATISFACTION OF OWNER.11.SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH ASCOAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVEDSHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION.12.SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BEREMOVED FROM SITE ON A DAILY BASIS.ABBREVIATIONS AND SYMBOLS:METERMDISCONNECT SWITCHTEST WELLCHEMICAL GROUND RODSINGLE-POLE THERMAL-MAGNETICCIRCUIT BREAKER2-POLE THERMAL-MAGNETIC CIRCUITBREAKERSUPPLEMENTAL GROUND CONDUCTORSOLID NEUTRAL BUS BARS/NSOLID GROUND BUS BARS/GSYMBOLS:RADIO BASE STATIONRBSINTERIOR GROUND RING (HALO)IGRGENERATORGENSMART INTEGRATED ACCESS DEVICESIADBARE COPPER WIREBCWEQUIPMENT GROUNDEGMASTER GROUND BARMGBAMERICAN WIRE GAUGEAWGEQUIPMENT GROUND RINGEGRREQUIREDREQTYPICALTYPTO BE RESOLVEDT.B.R.TO BE DETERMINEDT.B.D.RADIO FREQUENCYRFREFERENCEREFMINIMUMMIN.EXISTING(E)BASE TRANSCEIVER STATIONBTSABOVE GRADE LEVELAGLABBREVIATIONS:EXOTHERMIC WELD (CADWELD)(UNLESS OTHERWISE NOTED)GROUNDING WIREMECHANICAL CONNECTIONSITE WORK GENERAL NOTES:1.THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OFCONSTRUCTION.2.ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED INTHE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTIONOF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BEUSED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES,SUBCONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDEBUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D)TRENCHING AND EXCAVATION.3.ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTIONACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE" AND LATEST VERSION OF TIA 1019 "STANDARDFOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES ANDANTENNAS."4.ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECTSPECIFICATIONS.5.IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVEDFROM THE SITE AND DISPOSED OF LEGALLY.6.ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFEREWITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISEDISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECTTO THE APPROVAL OF CONTRACTOR, OWNER AND/OR LOCAL UTILITIES.7.THE SUBCONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICALSPECIFICATION FOR SITE SIGNAGE.8.THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE BTS EQUIPMENTAND TOWER AREAS.9.NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS,SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT.10.THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TOFINISHED SURFACE APPLICATION.11.THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THETOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TOPREVENT EROSION AS SPECIFIED ON THE PROJECT SPECIFICATIONS.12.SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION.EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCEWITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL.13.NOTICE TO PROCEED- NO WORK TO COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEEDAND THE ISSUANCE OF A PURCHASE ORDER.14.ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS,RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THEGENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN ANDSHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; ANDANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIESBEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) ANDCROWN STANDARD CED-STD-10253 INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIEDENGINEER FOR CLASS IV CONSTRUCTION TO CERTIFY THE SUPPORTING STRUCTURE(S) INACCORDANCE WITH THE ANSI/TIA-322 (LATEST EDITION).1.THE DESIGN DEPICTED IN THESE DRAWINGS IS VALID WHEN ACCOMPANIED BY ACORRESPONDING PASSING MOUNT ANALYSIS.2.CONSTRUCTION MANAGER/GENERL CONTRACTOR SHALL REVIEW THE MOUNTANALYSIS FOR ANY CONDITIONS PRIOR TO INSTALLATION.3.ANY REQUIRED MOUNT MODIFICATION OR MOUNT REPLACEMENT SHALL BEAPPROVED BY EOR.MOUNT ANALYSIS NOTES:6/19/2019
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0T-3REVISION:SHEET NUMBER:AT&T SITE NUMBER: IN0475BU #: 873708CARMEL HAZEL DELL10851 HAZEL DELL PKWYCARMEL, IN 46280MWA 120'-0" MONOPOLEISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE006/03/19BAGLJBFINAL CDS9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 46240GPD JOB NUMBER: 2019717.98520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.21028550 W. BRYN MAWR AVE, SUITE 100CHICAGO, IL 60631106/19/19AERLJBREV. PER COMMENTSGENERAL NOTES:1.FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY:CONTRACTOR- __________SUBCONTRACTOR- GENERAL CONTRACTOR (CONSTRUCTION)CARRIER- AT&TTOWER OWNER- CROWN CASTLE USA INC.OEM- ORIGINAL EQUIPMENT MANUFACTURER2.PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TOFAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BEACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BEBROUGHT TO THE ATTENTION OF CONTRACTOR AND CROWN CASTLE USA INC.3.ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLECODES, REGULATIONS AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICESAND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANYPUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALLCOMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCALJURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS.4.DRAWINGS PROVIDED HERE ARE NOT TO SCALE AND ARE INTENDED TO SHOW OUTLINE ONLY.5.UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT,APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THEDRAWINGS.6."KITTING LIST" SUPPLIED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT WILL BE SUPPLIED BYCONTRACTOR. ITEMS NOT INCLUDED IN THE BILL OF MATERIALS AND KITTING LIST SHALL BE SUPPLIEDBY THE SUBCONTRACTOR.7.THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITHMANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE.8.IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THESUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THECONTRACTOR AND CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OFINSTALLATION.9.SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES,GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWINGS.10.THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS,LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'SEXPENSE TO THE SATISFACTION OF OWNER.11.SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH ASCOAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVEDSHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION.12.SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BEREMOVED FROM SITE ON A DAILY BASIS.ABBREVIATIONS AND SYMBOLS:METERMDISCONNECT SWITCHTEST WELLCHEMICAL GROUND RODSINGLE-POLE THERMAL-MAGNETICCIRCUIT BREAKER2-POLE THERMAL-MAGNETIC CIRCUITBREAKERSUPPLEMENTAL GROUND CONDUCTORSOLID NEUTRAL BUS BARS/NSOLID GROUND BUS BARS/GSYMBOLS:RADIO BASE STATIONRBSINTERIOR GROUND RING (HALO)IGRGENERATORGENSMART INTEGRATED ACCESS DEVICESIADBARE COPPER WIREBCWEQUIPMENT GROUNDEGMASTER GROUND BARMGBAMERICAN WIRE GAUGEAWGEQUIPMENT GROUND RINGEGRREQUIREDREQTYPICALTYPTO BE RESOLVEDT.B.R.TO BE DETERMINEDT.B.D.RADIO FREQUENCYRFREFERENCEREFMINIMUMMIN.EXISTING(E)BASE TRANSCEIVER STATIONBTSABOVE GRADE LEVELAGLABBREVIATIONS:EXOTHERMIC WELD (CADWELD)(UNLESS OTHERWISE NOTED)GROUNDING WIREMECHANICAL CONNECTIONGREENFIELD GROUNDING NOTES:1.ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO,LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHERAT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS INACCORDANCE WITH THE NEC.2.THE SUBCONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCETO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODESYSTEMS, THE SUBCONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTALGROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS ORLESS.3.THE SUBCONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCINGGROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANYLOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THECONDUIT AND PROVIDE TESTING RESULTS.4.METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLYCONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THEDISCONTINUITY WITH #6 AWG COPPER WIRE UL APPROVED GROUNDING TYPECONDUIT CLAMPS.5.METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENTGROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREENINSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED ANDINSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT.6.EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTERGROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUNDWIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 AWG SOLIDTINNED COPPER FOR OUTDOOR BTS.7.CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKEDBACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS AREPERMITTED.8.ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARSAND THE GROUND RING SHALL BE #2 AWG SOLID TINNED COPPER UNLESSOTHERWISE INDICATED.9.ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BEUSED FOR GROUNDING CONNECTIONS.10.USE OF 90° BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BEAVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED.11.EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONSBELOW GRADE.12.ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALLBE FORMED USING HIGH PRESS CRIMPS.13.COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMICWELD CONNECTIONS.14.ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED ORBOLTED TO THE BRIDGE AND THE TOWER GROUND BAR.15.APPROVED ANTIOXIDANT COATINGS (I.E. CONDUCTIVE GEL OR PASTE) SHALLBE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS.16.ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSIONRESISTANT MATERIAL.17.MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMESAND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCEWITH THE NEC.18.BOND ALL METALLIC OBJECTS WITHIN 6 FT. OF MAIN GROUND WIRES WITH 1-#2AWG TIN-PLATED COPPER GROUND CONDUCTOR.19.GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNINGPROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTSTHAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS,METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS, WHEN IT ISREQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS ORLOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUITSHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G.,NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUNDCONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT.20.ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUSTBE #2 TINNED SOLID IN 3/4" LIQUID TIGHT CONDUIT FROM 24" BELOW GRADE TOWITHIN 3" TO 6" OF CAD-WELD TERMINATION POINT. THE EXPOSED END OF THELIQUID TIGHT CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADDTRANSITIONING GROUND STANDARD DETAIL AS WELL).240/120 1ØDESCRIPTIONLEG 1PHASE/CODE LETTERWIRE COLORLEG 2BLACKREDAC NEUTRALNWHITEGROUND (EGC)GGREENVDC POS+*RED-POLARITY MARKAT TERMINATIONVDC NEG-240V OR 208V, 3ØPHASE APHASE BPHASE CBLACKRED(ORG. IF HI LEG)BLUE480V, 3ØPHASE APHASE BPHASE CBROWNORANGE OR PURPLEYELLOWNEC INSULATOR COLOR CODE* SEE NEC 210.5(C)(1) AND (2)*BLACK-POLARITYMARK AT TERMINATIONELECTRICAL INSTALLATION NOTES:1.ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECTSPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES.2.CONDUIT ROUTINGS ARE SCHEMATIC. SUBCONTRACTOR SHALL INSTALL CONDUITS SO THATACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED.3.WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THEREQUIREMENTS OF THE NEC. HILTI EPOXY ANCHORS ARE REQUIRED BY CROWN CASTLE USA INC.4.ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIREDBY THE NEC.5.CABLES SHALL NOT BE ROUTED THROUGH LADDER-STYLE CABLE TRAY RUNGS.6.EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I.E., HOTS), GROUNDING AND T1CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR-CODED INSULATION OR ELECTRICALTAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THEIDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA.7.ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH PLASTIC TAPE PER COLORSCHEDULE. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASECONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT IDNUMBERS (I.E. PANEL BOARD AND CIRCUIT ID'S).8.PANEL BOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALLBE CLEARLY LABELED WITH PLASTIC LABELS.9. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES.10.POWER, CONTROL AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLECONDUCTOR (#14 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDEDCOPPER CABLE RATED FOR 90° C (WET & DRY) OPERATION LISTED OR LABELED FOR THELOCATION AND RACEWAY SYSTEM USED UNLESS OTHERWISE SPECIFIED.11.SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR(#6 AWG OR LARGER), 600V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION CLASS BSTRANDED COPPER CABLE RATED FOR 90° C (WET AND DRY) OPERATION LISTED OR LABELEDFOR THE LOCATION AND RACEWAY SYSTEM USED UNLESS OTHERWISE SPECIFIED.12.POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI-CONDUCTOR, TYPETC CABLE (#14 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDEDCOPPER CABLE RATED FOR 90° C (WET AND DRY) OPERATION WITH OUTER JACKET LISTED ORLABELED FOR THE LOCATION USED UNLESS OTHERWISE SPECIFIED.13.ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGSAND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOROPERATION AT NO LESS THAN 75° C (90° C IF AVAILABLE).14.RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE INACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC.15.ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E. RIGID PVC SCHEDULE40 OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USEDFOR EXPOSED INDOOR LOCATIONS.16.ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT) OR RIGIDNONMETALLIC CONDUIT (RIGID PVC, SCHEDULE 40) SHALL BE USED FOR CONCEALED INDOORLOCATIONS.17.SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90sAND ALL APPROVED ABOVE GRADE PVC CONDUIT.18.LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS ANDOUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED.19.CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVEDFOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE.20.CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCEWITH NEMA, UL, ANSI/IEEE AND NEC.21.WIREWAYS SHALL BE EPOXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TOSWING OPEN DOWNWARDS; SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (ORBETTER).22.CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPSAND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BEPERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TOTHE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTEAROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BEINSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TOSTRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS.ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENTCONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TOBOXES BY GALVANIZED MALLEABLE IRON BUSHIN ON INSIDE AND GALVANIZED MALLEABLE IRONLOCKNUT ON OUTSIDE AND INSIDE.23.EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BEGALVANIZED OR EPOXY-COATED SHEET STEEL; SHALL MEET OR EXCEED UL 50 AND RATED NEMA1 (OR BETTER) INDOORS OR NEMA 3R (OR BETTER) OUTDOORS.24.METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPOXY-COATED ORNON-CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA 1 (ORBETTER) INDOORS OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS.25.NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2;AND RATED NEMA 1 (OR BETTER) INDOORS OR WEATHER PROTECTED (WP OR BETTER)OUTDOORS.26.THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THECONTRACTOR BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS.27.THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES ANDDISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TOSAFEGUARD LIFE AND PROPERTY.28.INSTALL PLASTIC LABEL ON THE METER CENTER TO SHOW "AT&T".29.ALL CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORDINSTALLED.6/19/2019