Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A60-2
Refrigerator RangeVent HoodDWUP DN 90 80 70 60 50 40 30 AREA OF WORK NEW WALL NON-LOAD BEARING INTERIOR PARTITION EXISTING WALL TO REMAIN GENERAL FLOOR PLAN NOTES THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. A. NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE THE CONTRACTOR FROM ITS RESPONSIBILITY TO PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, ANCHORAGE, AND COORDINATION WITH ALL OTHER SUBCONTRACTORS AND TRADES, OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THESE DOCUMENTS, OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO ALERT THE ARCHITECT TO ERRORS OR OMISSIONS CONTAINED THEREIN. B. THE CONTRACTOR AND ALL ITS SUBCONTRACTORS SHALL VERIFY IN THE FIELD ALL NEW AND EXISTING APPLICABLE CONDITIONS, DIMENSIONS, RELATIONSHIPS, ETC. SHOWN IN THESE DRAWINGS AND AS PERTINENT TO THE INTENT OF THESE DRAWINGS. ANY DISCREPANCY DISCOVERED SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK AFFECTED BY, OR RELATED TO, SUCH DISCREPANCY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH, OR CAUSED BY, ITS FAILURE TO COMPLY WITH THIS REQUIREMENT. C. ALL FLOOR PLAN DIMENSIONS SHOWN ON THE NEW FLOOR PLANS ARE FROM FACE OF STUD (WHETHER NEW OR EXISTING WALL) UNLESS INDICATED OTHERWISE BY THE DESIGNATIONS "CLR", "CLEAR", OR "MIN." COORDINATE WITH APPLICABLE NEW WALL TYPES AND WITH APPLICABLE SECTIONS/DETAILS. D. ALL NEW HOLLOW METAL (HM). DOOR FRAMES ARE LOCATED 4" FROM THE ADJACENT WALL FACE (TO OUTER EDGE OF FRAME) UNLESS DIMENSIONED OR DETAILED OTHERWISE. E. COORDINATE, PROVIDE, AND INSTALL 2X FIRE TREATED WOOD WALL BLOCKING AS REQUIRED FOR THE ANCHORAGE AND SUPPORT OF ALL NEW CASEWORK, TRIM, FIRE EXTINGUISHER CABINETS, TOILET ACCESSORIES, MARKER BOARDS, TACK BOARDS, DOOR HARDWARE ACCESSORIES, ETC., AS APPLICABLE. F. ALL NEW OR EXISTING FLOOR AREAS THAT REQUIRE LEVELING WITH A CONCRETE TOPPING OR LEVELING COMPOUND SHALL BE INSTALLED SUCH THAT THE FLATNESS EQUALS 35/24 (ON ALL SLABS) AND THE LEVELNESS EQUALS (SLAB ON GRADE) AND 80% OF THAT VALUE ON ELEVATED SLABS. G. AT ALL WALLS SCHEDULED TO RECEIVE CERAMIC TILE, PROVIDE GLASS MAT INTERIOR GYPSUM WALLBOARD FOR THE STANDARD GYPSUM WALLBOARD IDENTIFIED IN THE WALL TYPES. REFER TO ROOM FINISH SCHEDULE FOR LOCATIONS OF CERAMIC TILE. PROVIDE CEMENT BACKER BOARD AT NATURAL SLATE TILE. REFER TO ROOM FINISH SCHEDULE FOR LOCATIONS OF SLATE TILE. H. AT ALL AREAS WHERE EXISTING FLOOR COVERING OR WALL COVERING MATERIAL WAS REMOVED, THE CONTRACTOR SHALL PROPERLY PREPARE THE SURFACE TO RECEIVE NEW FINISHES. I. CONTRACTOR SHALL ENSURE THAT ANY AND ALL BACKBOXES LOCATED WITHIN 'PARTY WALLS' THAT SEPARATE ROOMS ARE NOT LOCATED BACK TO BACK OR IN THE SAME CAVITY. STAGGER BOXES ONE STUD CAVITY EITHER SIDE OF ONE ANOTHER. 1 A60-6 20' - 0"4' - 7 1/2" 5' - 1"2' - 1" 7' - 5 1/2" 1' - 8 1/2" 5' - 11" 6' - 6" CLR 5' - 1"CLR4' - 4" 20' - 0"STACKED W/D 4' - 0" 105107103B 103A LAUNDRY 105 LIFT 106 GARAGE 107 GUEST BATH 103 BEDROOM 1 102 MUD ROOM 104 ENTRY HALL 101 2' - 0" 3' - 7 1/2"102B4' - 6 1/2"30" SB WC 30" SHOWER 34" 4' - 1 1/2" HVAC CHASE 3' - 3"ALIGN WALL FRAMING13' - 7" 20' - 1" 106 102A W4.1 W4.1 W4.1 W6.1 W4.1 W6.1 W4.1 W4.1 CARPET WOODTILECARPET 1 A60-6 13' - 0"6' - 8 1/2" CLR4' - 4"CLR 5' - 1" 1' - 5"LIFT 203 BATH 204 KITCHEN 202 DINING 201 FRONT BALCONY 200 20413' - 0"17' - 6" 14' - 1 1/2" 3" 36" 3" 30" 15" 36" 15" 30" 42" 2' - 8 1/2"12' - 9 1/2" 5' - 1 1/2" 3' - 10" 5' - 9" 5' - 1 1/2"5' - 1 1/2"GAS FIREPLACE 45.00°3' - 6"1' - 8 1/2"RAILING 4 1/2"33" 4 1/2" 27" 21" 36" 24" 4 1/2" 203 1 A60-6 CLR 5' - 1 1/2"CLR4' - 4"STAIR 01 LIFT 05 BASEMENT / MECH 04 7' - 8" W6.1 W4.1 W4.50205 9 1/2" 3' - 2" 4" R TAR19900111 A CRHCETI STATE OF BTTOCS No. TSIGER ERED NETRA EP K SNI I A N ADNI ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 400 INDIANAPOLIS, INDIANA 46204 BLACKLINESTUDIO.NET 317.803.7900 M.E.P. GENESIS ENGINEERING GROUP 91 SOUTH MAIN STREET, SUITE 200 ZIONSVILLE, IN 46077 GENESIS-ENGINEERING.COM 317.927.8307 STRUCTURAL SCHWARZ ENGINEERING GROUP WWW.SCHWARZINC.COM 317.850.5133 - - ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. © 2017 BLACKLINE STUDIO CERTIFICATION: CHECKED:DRAWN: S:\_Projects\Monon & Main - Carmel\002 Drawings\005 Revit\121818 _ Monon & Main - A18 - Townhome Interiors.rvt 3/21/2019 11:35:37 AM A60-2COPYRIGHT 2018 BASEMENT, FIRST AND SECOND FLOOR PLANMonon & Main BrownstonesMonon & Main St., Carmel INwzwz CDs -PERMIT SET 3/21/2019 Lot 60 ---KEY PLAN - Lot 60 WALL TYPE LEGEND 1/4" = 1'-0" FIRST FLOOR PLAN - Lot 602 1/4" = 1'-0" SECOND FLOOR PLAN - Lot 603 1/4" = 1'-0" BASEMENT FLOOR PLAN - Lot 601 #REVISION Date 06/12/19 Mike Sheeks