HomeMy WebLinkAboutCLAY CORNER 16 - CC016 (AS DESIGNED)IECC 2009 Performance Compliance Property 1510 JENSEN DR CARMEL, IN 46032 Model: CHARTWELL (C) Community: CLAY CORNER 16 CC016 (AS DESIGNED) CLAY CORNER 16 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,383 $200 $372 $1,955 $801 $0 $2,756 Requirements C-M, Energy Solutions As Designed $1,327 $184 $372 $1,883 $801 $0 $2,684 C4405.3 Performance-based compliance passes by 3.7% 402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 3.7%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 316119 at 10:25 AM Ekotrope RATER - Version 3.1.0.2123 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 1510 JENSEN DR CARMEL, IN 46032 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor N/A Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.33, SHGC: 0.28 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 252.0 CFM @ 25Pa Total Duct Leakage 336.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 316119 at 10:25 AM Ekotrope RATER - Version 3.1.0.2123 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property Organization 1510 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL (C) Community: CLAY CORNER 16 Builder LENNAR HOMES CCO16 (AS DESIGNED) CLAY CORNER 16 General Building Information Conditioned Area (sq ft) 4,246 Conditioned Volume (cubic ft) 38,214 Insulated Shell Area (sq ft) 8,312 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (2,123 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 194, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 20, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB 2X4 (1,746 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I [ Name: CONDIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Energy Code Inspection Checklist Property 1510 JENSEN DR CARMEL, IN 46032 Model: CHARTWELL (C) Community: CLAY CORNER 16 CC016 (AS DESIGNED) CLAY CORNER 16 El Name: RIM CONDIAMB (194 s.f.) R: 13.575 Roof Name: CONDIGAR (20 s.f.) R: 10.876 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Name: SECOND (2,123 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f. ) U: 0.182 Glazing Inspection Status Results are projected 11 Name: FRONT (72 s.f.), U:0.330, SHGC: 0.28, Orientation: SOUTH El Name: BACK (90 s.f.), U:0.330, SHGC: 0.28, Orientation: NORTH Name: LEFT SIDE (63 s.f.), U:0.330, SHGC: 0.28, Orientation: WEST El Name: LEFT SIDE GD (18 s.f.), U:0.330, SHGC: 0.28, Orientation: WEST E] Name: BSMT (32 s.f.), U:0.330, SHGC: 0.28, Orientation: WEST E] Name: RIGHT SIDE (53 s.f.), U:0.330, SHGC: 0.28, Orientation: EAST E] Name: BSMT (16 s.f.), U:0.330, SHGC: 0.28, Orientation: EAST C-M, Energy Solutions 2 Energy Code Inspection Checklist Property 1510 JENSEN DR CARMEL, IN 46032 Model: CHARTWELL (C) Community: CLAY CORNER 16 CCO16 (AS DESIGNED) CLAY CORNER 16 Skylight None Present Mechanical Ventilation None Present Mechanical Equipment Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected 0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE M Air conditioner • Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 3,185 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 252.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 336.0 CFM @ 25Pa C", Energy Solutions 3 Energy Code Inspection Checklist Property 1510 JENSEN DR CARMEL, IN 46032 Model: CHARTWELL (C) Community: CLAY CORNER 16 CCO16 (AS DESIGNED) CLAY CORNER 16 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 5N5 4 Building Summary C-M Energy Solutions Property Organization Inspection Status 1510 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL (C) Community: CLAY CORNER 16 Builder LENNAR HOMES CCO16 [AS DESIGNED] CLAY CORNER 16 Generakuilding Information Number Of Bedrooms 4 Number Of Floors 1 Conditioned Floor Area [sq_ ft.] 4;246 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 38;214 Total Units in Building 1 Residence Type Single family detached Madel CHARTWELL (C) Community CLAY CORNER 16 Climate Zone 5A Basement Wall d6 Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, Oft 1 8 194 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, Oft 1 8 20 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Tap To InsuIation Feet From Wall Top Tb Insulation Is Fully Insulated R -value Top Bottom R-11 Draped, 4ft 0 4 No 11.00 Slab BSMT Uninsulated 214 Below Grade ❑ 0 2,123.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall C Uninsulated Woad Frame / Other Na ❑ 0 D 0.00 1 Building Summary Property 1510 JENSEN DR CARMEL, IN 46032 Model: CHARTWELL [C] Community: CLAY CORNER 16 CC016 [AS DESIGNED] CLAY CORNER 16 Framed Floor Framed Floor Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Rim Joist Name Library Type Surface Area Location CONDIGAR G1 R-13, OSB 20.0 sq. ft. Exposed Exterior RIM CONDIAMB G1 R-13, R-3.0 194.0 s9. ft. Exposed Exterior Rim Joist Library List Name G1 R-13, OSB G1 R-13, R-3.0 Walr Name CONDIAMB 2X4 C O N DIGAR 10.876 13.575 Library Type Surface Color G1 R-13 BATT, R-3.0 Medium G1 R-13 Gar Walls Medium Surface Area Location 1.746.0 sq. ft. Exposed Exterior 180.0 sq. ft. Unconditioned, attached garage Building Summary Property Organization Inspection Status C-MEnergy Solutions 1510 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL [C] Community: CLAY CORNER 16 Builder LENNAR HOMES CCO16 [AS DESIGNED] CLAY CORNER 16 Walllibrary List Name R -value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 Glazing Name Library Type I Wall Assignment Basement Wall Overhang Assignment Depth Overhang Ft Top To Overhang Ft To Bottom Orientation M Surface Area BACK U-.33, SHGC-28 CONDIAMB 2704 0 0 0 North 90.0 sq. ft BSMT U-.33, SHGG28 CONDIAMB 0 0 0 West 32.0 sq. R BSMT U-33, SHGG28 CONDIAMB 2X4 0 0 ❑ East 16.0 sq. R FRONT U-33, SHGG28 CONDIAMB 2X4 0 0 ❑ South 72.0 sq. fL LEFT SIDE U-33, SHGG28 CONDIAMB 2X4 0 0 ❑ West 63.0 sq. fL LEFT SIDE GD U-33, SHGG28 CONDIAMB 2X4 0 0 ❑ West 18.0 sq. ft RIGHT SIDE U-33, SHGG28 CONDIAMB 2X4 0 0 ❑ East 53.0 sq. ft Glazing Library List Name Shg c U #actor U-33, SHGC-28 0.28 0.334 Skylight Skylight Library List 3 Building Summary Property Organization 1510 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL [C] Community: CLAY CORNER 16 Builder LENNAR HOMES CCO16 [AS DESIGNED] M CLAY CORNER 16 Surface Area Location Opaque Door Name Library Type Wall Assignmen, FRONT Fiberglass Door CONDIAMB 2X4 GARAGE Fiberglass Door CONDIGAR Opaque Door Library List J6 Name IFiberglass Door sement Wall Assign ment 0.182 Inspection Status Results are projected Solar Absorptance C-M, Energy Solutions PF M r Surface Area Location 0.9 0.75 Medium 20.0 sq- ft Exposed Exterior 0.9 0.75 Medium 18.0 sq- ft Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area P.f.] Tiles SECOND R-38 Blown, GR1 2,123 No Medium 2.123.0 sq. R Roof Insulation Library List Name Has Radiant Barrier ?•8 3 :. .a l No Whole House Infiltratic Infiltration I5 ACH at 50 Pa Mechanical Ventilation R -value 38268 Blower -door tested 4 Location Attic M Building Summary Property Organization Inspection Status 1510 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL [C] Community: CLAY CORNER 16 Builder LENNAR HOMES CCO16 [AS DESIGNED] CLAY CORNER 16 Lighting % Interior Fluorescent °% Interior LED Ughting % Exterior Fluorescent % Exterior LED Lighting Lighting Lighting 100 0 100 Onsite GenerationMEN&MM � None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Library Type Heating Percent Load Air co nd itione r CA13NA042 0% Fuel -fired air 9155A4808OS17 100% distribution Water Heatinq RE350" 0% C-M, Energy Solutions Fluorescenl Lighting C 10 Cooling Percent Load Hot Water Percent Load 100% 0% 0% 0% 0% 100% Building Summary Property 1510 JENSEN DR CARMEL, IN 46032 Model: CHARTWELL (C) Community: CLAY CORNER 16 CCO16 [AS DESIGNED] CLAY CORNER 16 Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Equipment Type: 915SA48080S17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 Etc uipment Type: CA13NA042 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Electric Forced Air PSG (Single Speed) 13 SEER 46 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 C-M, Energy Solutions A Building Summary Property C-MEnergy Solutions Organization Inspection Status 1510 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: CHARTWELL [C] Community: CLAY CORNER 16 Builder LENNAR HOMES CCO16 [AS DESIGNED] CLAY CORNER 16 Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution Cooling Equipment Air conditioner Sq. Feet Served 4246 # Return Grilles 5 Supply Duct R Value 10 Return Duct R Value 10 Supply Duct Area [sq. ft.] 1146.42 Return Duct Area [sq. ft_] 1061.5 Duct Leakage to Outdoors (CFM25) 252 Total Leakage 336 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ rCeiling Fan W Has Ceiling Fan No Cfm Per Watt 101 7 Building Summary Property 1510 JENSEN DR CARMEL, IN 46032 Model: CHARTWELL [C] Community: CLAY CORNER 16 CCO16 [AS DESIGNED] CLAY CORNER 16 Water Distribution MM Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption r5N5 Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Standard No 50 No No 30 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year C-M, Energy Solutions ,�