Loading...
HomeMy WebLinkAboutClay Corner 16 TRICO10701 N. College Avenue Suite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trico.eco Residential SANITARY SEWER PERMIT 999913196 Permit Type Final Subdivision Clay Corner Project WO 2017-1335 Section Number Project Name Clay Corner Lot Number 16 Project Developer Address Number 1510 Lift Station 19 Village of Westclay Station Address 2 Treatment Plant MIX Street Jensen Drive Parcel Acreage 0.15 City Carmel EDU in Gallons 310 Zip Code 46032 County Hamilton Local Sewer Charge - District Contribution 0.00 Builder Lennar Plan Review and Inspection 0.00 - - -- -- ---- Application Fee 150.00 Phone Number 317-659-3230 EDU Fee 190800 Owner Interceptor Fee _ _. 0.00 Phone Number Other Fees _ 0.00 ..._ ..._ _._ __... Fees Due 2058.00 Occupant Invoice Number Phone Number PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench" phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TdCo will assume no liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and the like; caused by construction activity on the building site which is the subject of this permit. Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in advance. All new construction will be placed on billing two months after connection has been made or when water is connected, whichever comes first. The building has: Main ID: CC118-CC117 Grease Trap Slab Foundation usMH Grease Interceptor Crawl Space - - - Manhole IDs CC -118 CC -117 DSMH ........... Grit Interceptor Basement YES Lid Elevation 886.02-/885.13 ✓ Grinder Station First Floor Elevation 889.77 / 889.77 Water Service City of Carmel Basement Elevation 879.90 v 879.90 Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor3.75! 4.641 Ft.� Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only u1 icuuy l�HUII b LJJb, au 1W a upeuwn ib pei iouneu anu a uemncaie or uompuance is issued prior to occupancy t sale of a properrty. Please review attached I/I Permit. 4X Manholes shall remain accessible at all times. Buried manholes will be corrected by the DeveloperlOwner. �! The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure. he terms of the conditional permit, if any, are listed below. Plans have been submitted. All fees have been paid. No certificate of insurance required. No additional permits required. No manhole core permit required. The facility is not classified as a FOG facilitv. By signing below, I attest that I am Builder/ Owner Signature Printed Name' Approved By Ryan Permit is valid for (Notes) and agree to accept responsibility for Phone Numbep from the date issued. Permit valid only with permit.