HomeMy WebLinkAboutLEGACY PRAIRIE 1103 - LP1103 (AS DESIGNED)IECC 2009 Performance Compliance Property 14236 FROSTBURG RD CARMEL, IN 46033 Model: EDINBURGH Community: LEGACY PRAIRIE 1102 LP1103 (AS DESIGNED) LEGACY PRAIRIE 1103 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $848 $109 $350 $1,308 $571 $0 $1,879 Requirements C-M, Energy Solutions As designed S514 S12g S350 $1,093 S571 so $1,663 C4405.3 Performance-based compliance passes by 16.5% 402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 16.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 412119 at 8:26 AM Ekotrope RATER - Version 3.1.1.2143 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 14236 FROSTBURG RD CARMEL, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor R-38 Slab R-10.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.32, SHGC: 0.34 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 118.0 CFM @ 25Pa Total Duct Leakage 189.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 4!2!19 at 8:26 AM Ekotrope RATER - Version 3.1.1.2143 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 14236 FROSTBURG RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: EDINBURGH Community: LEGACY PRAIRIE 1102 Builder LENNAR HOMES LP1103 (AS DESIGNED) LEGACY PRAIRIE 1103 General Building Information Conditioned Area (sq ft) 2,364 Conditioned Volume (cubic ft) 19,776 Insulated Shell Area (sq ft) 5,449 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab Li Name: SLAB 1 (536 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Name: SLAB 2 (66 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (411 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (950 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (85 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property organization 14236 FROSTBURG RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: EDINBURGH Community: LEGACY PRAIRIE 1102 Builder LENNAR HOMES LP1103 (AS DESIGNED) LEGACY PRAIRIE 1103 Name: CONDIGAR (364 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIGAR 2X6 (112 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I El Name: CONDICOND (1,664 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (71 s.f.) R: 13.575 Name: CONDIGAR (59 s.f.) R: 10.876 Name: CONDICOND (118 s.f.) R: 10.876 Roof El Name: MAIN (1,013 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 14236 FROSTBURG RD TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: EDINBURGH Community: LEGACY PRAIRIE 1102 Builder LENNAR HOMES LP1103 (AS DESIGNED) LEGACY PRAIRIE 1103 E] Name: FRONT (99 s.f.), U: 0.320, SHGC: 0.34, Orientation: EAST E] Name: BACK (114 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST El Name: SLIDER (33 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST El Name: GD (20 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE Air conditioner {2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 1,648 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 14236 FROSTBURG RD CARMEL, IN 46033 Model: EDINBURGH Community: LEGACY PRAIRIE 1102 LP1103 (AS DESIGNED) LEGACY PRAIRIE 1103 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 118.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 189.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 14236 FROSTBURG RD TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: EDINBURGH Community: LEGACY PRAIRIE 1103 Builder LENNAR HOMES LP1103 [AS DESIGNED] LEGACY PRAIRIE 1103 enera?Building Informationmber Of Bedrooms 3 mber Of Floors 3 nditioned Floor Area [sq_ ft.] 2;364 conditioned, attached garage? Yes nditioned Volume [Cu. ft.] I 19;776 tal Units in Building 1 sidence Type Townhouse; inside unit odel EDINBURGH mmunity LEGACY PRAIRIE 1103 mate Zone 5A Basement Wall None Present Basement Wall Library List None Present C-M, Energy Solutions xposed Surface Area Location Enclosing ry Area SLAB 1 R-10, 2'down 53 On Grade 123 0 536.0 sq. ft. Exposed Exterior Conditioned Space SLAB 2 R-10, 2'down 35 On Grade 123 0 66.0 sq. rL Exposed Exterior Conditioned Space Slab Library Lisi Name Wall R-10, 2'down Woad Frame / Other No ❑ 2 1 D 0.00 1 Building Summary Property Organization 14236 FROSTBURG RD TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: EDINBURGH G1 R-13, OSB Community: LEGACY PRAIRIE 1103 Builder G1 R-13, OSB LENNAR HOMES LP1103 (AS DESIGNED) 950.0 sq. fl. LEGACY PRAIRIE 1103 Effective Insulation R -value ramed Floor Medium Name Library Type Ca OVER GARAGE R-38, GR1 13.575 Medium 1.664.0 sq. ft. Framed Floor Library List Name Effective R -value R-38, GR1 2 33.825 Rim Joist Name Library Type CONDIAMB G1 R-13, R-3.0 CONDJCOND Library Type G1 R-13, OSB CONDIGAR Location G1 R-13, OSB G1 R-13 BATT R-3.0 Rim Joist Library List 950.0 sq. fl. Name Effective Insulation R -value G1 R-13, OSB Medium 10.876 G1 R-13. R-3.0 CONDJCOND 13.575 C-M Energy Solutions Inspection Status Results are projected e Surface Area Location 1.23 Above Grade 411.0 sq. ft Unconditioned, attached garage 71.0 sq. ft. Exposed Exterior 118.0 sq. ft. Conditioned Space (Adiabatic) 59.0 sq. ft. Unconditioned, attached garage alll Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-13 BATT R-3.0 Medium 950.0 sq. fl. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 85.0 sq. fl. Exposed Exterior CONDJCOND G1 R-22 Dbl Wall Medium 1.664.0 sq. ft. Conditioned Space (Adiabatic) 2 Building Summary Property 14236 FROSTBURG RD CARMEL, IN 46033 Model: EDINBURGH Community: LEGACY PRAIRIE 1103 LP1103 [AS DESIGNED] LEGACY PRAIRIE 1103 Name Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Library Type Inspection Status Results are projected Surface Calor Surface Area C-MEnergy Solutions Location CONDIGAR G1 R-13 Gar Walls Medium 364.0 sq. ft. Unconditioned, attached garage CONDIGAR 2X6 G1 R-19, 2x6 GAR Medium 112.0 sq. it- Unconditioned, attached garage Wall Library List Name Effective R value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, 2x6 GAR 16218 G1 R-19, R-3.0 2X6 20217 G1 R-22 Dhl Wall 18.407 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft Te Overhang Ft Te Orientation Surface Area Assignment Top Bottom BACK 11-.32, SHGG.34 CONDIAMB ❑ 0 ❑ West 114.0 sq. 11 FRONT 11-.32, SHGG.34 CONDIAMB ❑ 0 ❑ East 99.0 sq. fL GD 11-.32, SHGG.34 CONDIAMB 2X6 ❑ 0 0 West 20.0 sq. fL SLIDER U-.32, SHGG.34 CONDIAMB ❑ 0 0 West 33.0 sq. ft Glazing Library List Name Shg c U -factor U-.32, SHGC-.34 0.34 0.320 3 Building Summary Property 14236 FROSTBURG RD CARMEL, IN 46033 Model: EDINBURGH Community: LEGACY PRAIRIE 1103 LP1103 [AS DESIGNED] LEGACY PRAIRIE 1103 kyligh Skylight Library List Opaque Door Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta nce FRONT Steel Door CONDIAMB 2X6 0.9 0.75 Medium 20.0 sq. it Exposed Exterior GARAGE Steel Door CONDIGAR 2X6 0.9 0.75 Medium 18.0 sq- ft Exposed Exterior Opaque Door Library List Name Effective U -factor 0.182 Roof Insulation Name Library Type MAIN R-38 Blown. GR1 krea Clay or Concrete Root P.f.] Tiles 7,013 No Roof Insulation Library List Name Has Radiant Barrier Effective R -value '•0 �- -I :a l No 38268 n Medium 1,013-0 sq. ft Attic 4 Building Summary Property 14236 FROSTBURG RD CARMEL, IN 46033 Model: EDINBURGH Community: LEGACY PRAIRIE 1103 LP1103 [AS DESIGNED] LEGACY PRAIRIE 1103 FWhole House Infiltration Infiltration 5 ACH at 50 Pa Mechanical Ventilation Lighting , °I Interior Fitiorescent Lighting Onsite Generation Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Blower -door tested 4 rang Y. txsenor rmorescem Lighting 100 0 None Present Onsite Generation Library List None Present Solar Generation Solar Generation Library List C-M, Energy Solutions Lighting 100 Building Summary Property Organization Inspection Status 14236 FROSTBURG RD TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons PSG (Single Speed) Model: EDINBURGH 95.5 AFUE Heating Capacity [kBtulh] Community: LEGACY PRAIRIE 'I'I '• Builder No EAE [kWh] LENNAR HOMES Equipment Type: CA13NA0361,m LP1103 (AS DESIGNED) Fuel Type Electric LEGACY PRAIRIE 1103 Forced Air Motor Type onditioning Equipment Cooling Efficiency 13 SEER Name Library Type Heating Percent Load Co( Air conditioner (2) Equipment Type: RE350* CA13NA036 0% C-M, Energy Solutions g Percent Load Hot Water 100% 0% Fuel4red air 9155A4808OS17 100% 0% 0% distribution (1) Water Heating (3) RE350" 0% 0% 100% 1 Equipment Type: 915SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 Equipment Type: CA13NA0361,m Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 34.2 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Building Summary Property 14236 FROSTBURG RD CARMEL, IN 46033 Model: EDINBURGH Community: LEGACY PRAIRIE 1103 LP1103 [AS DESIGNED] LEGACY PRAIRIE 1103 1butivn System tion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area [sq. ft.] ]uct Area [sq. ft_] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 2364 2 3❑ 3❑ 478.7 177.3 118 189 Post -Construction Yes Conditioned Space 5❑ 50 Attic (well vented; under insulation) 5❑ 5❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property Organization Inspection Status 14236 FROSTBURG RD TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: EDINBURGH No Community: LEGACY PRAIRIE 1103 Builder Recirculation System Pipe Loop Length [ft] LENNAR HOMES LP1103 [AS DESIGNED] No LEGACY PRAIRIE 1103 ater Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 86 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 30 Drain Water Heat Recovery? No r othes Dryer elType Electric f 2.617 ld utilization Timer Controls Clothes Washer ff"W Label Energy Rating 764 kWh/Year Electric Rate 0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.874 1 mef 0.331 Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Yes Standard 270 kWh Electric No No 709 kWh/Year "M � TSI Energy Solutions ,�