HomeMy WebLinkAboutLEGACY RIDGE 105 - LR105 (AS DESIGNED)IECC 2009 Performance Compliance
Property
14324 NEW GARDEN LN
CARMEL, IN 46033
Model: 3500 RIVIERA A
Community: LEGACY RIDGE 105
LR105 (AS DESIGNED)
LEGACY RIDGE 105
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,728
$272
$398
$2,398
$932
$0
$3,330
Requirements
C-M,
Energy Solutions
As Designed
$1,560
$256
$398
$2,214
$932
$0
$3,146
C4405.3 Performance-based compliance passes by 7.7%
402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGG
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 7.7%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
3113119 at 11:18 AM
Ekotrope RATER - Version 3.1.0.2130
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
14324 NEW GARDEN LN
�, FT Pi
CARMEL, IN 46033
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-11
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.31, SHGC: 0.32
Building Features
Duct Supply R-30.0, Return R-20.0
Duct Leakage to Outside 288.0 CFM @ 25Pa
Total Duct Leakage 384.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 3113119 at 11:18 AM
Ekotrope RATER - Version 3.1.0.2130
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property
Organization
14324 NEW GARDEN LN
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Model: 3500 RIVIERA A
Community: LEGACY RIDGE 105
Builder
LENNAR HOMES
LR105 (AS DESIGNED)
LEGACY RIDGE 105
General Building Information
Conditioned Area (sq ft) 5,348
Conditioned Volume (cubic ft) 47,840
Insulated Shell Area (sq ft) 9,419
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identity any changes and ensure
that the home continues to meet the applicable energy code.
Slake
Name: BSMT (1,712 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
Name: OVER GARAGE (402 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
El Name: OVER AM8IENT (14 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
] Name: CONDIAMB (Exterior Perimeter [ft]: 131, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
] Name: CONDIGAR (Exterior Perimeter [ft]: 43, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB (2,367 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
organization
14324 NEW GARDEN LN
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Model: 3500 RIVIERA A
Community: LEGACY RIDGE 105
Builder
LENNAR HOMES
LR105 (AS DESIGNED)
LEGACY RIDGE 105
El Name: CONDIAMB 2X6 (270 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (387 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIATTIC (206 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (270 s.f.)
R: 13.575
Name: CONDIGAR (43 s.f.)
R: 10.876
Name: CONDIATTIC (54 s.f.)
R: 10.876
Roof
El Name: SECOND (2,128 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
C",
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization Inspection Status
14324 NEW GARDEN LN TSI Energy Solutions Results are projected
CARMEL, IN 46033 Matthew Timmons
Model: 3500 RIVIERA A
Community: LEGACY RIDGE 105 Builder
LENNAR HOMES
LR105 (AS DESIGNED)
LEGACY RIDGE 105
E] Name: FRONT (132 s.f.), U:0.310, SHGC: 0.29, Orientation: EAST
E] Name: BACK (174 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST
El Name: BACK 2X6 (77 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST
El Name: BACK 2X6 GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST
El Name: RIGHT SIDE (83 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH
El Name: RIGHT SIDE BSMT (16 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH
11 Name: LEFT SIDE (59 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH
11 Name: LEFT SIDE BSMT (16 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE
E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
El Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
Test Status: Blower -door tested 3
House is air -sealed as to achieve 3,987 CFM50 (5.00 AC H50) or less at final blower -door test.
Energy Code Inspection Checklist
Property
14324 NEW GARDEN LN
CARMEL, IN 46033
Model: 3500 RIVIERA A
Community: LEGACY RIDGE 105
LR105 (AS DESIGNED)
LEGACY RIDGE 105
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Infiltration Requirements for IECC in Climate Zone 5
Inspection Status
Results are projected
2009 IECC. Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 288.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 384.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
C-M
Energy Solutions
Property Organization Inspection Status
14324 NEW GARDEN LN TSI Energy Solutions Results are projected
CARMEL, IN 46033 Matthew Timmons
Model: 3500 RIVIERA
Community: LEGACY RIDGE 105 Builder
LENNAR HOMES
-R1 05 (AS DESIGNED)
LEGACY RIDGE 105
I
eneral Building Informationmber Of Bedrooms 4
mber Of Floors 2
nditioned Floor Area [sq_ ft.] 5;348
conditioned, attached garage? Yes
nditioned Volume [Cu. ft.] 47;840
tal Units in Building 1
sidence Type Single family detached
adel 3500 RIVIERA A
mmunity LEGACY RIDGE 105
mate Zone 5A
Basement Wall
d6
Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB R-11 Draped, Oft 1 8 131 Exposed Exterior Conditioned Space
CONDIGAR R-11 Draped, Oft 1 8 43 Exposed Exterior Conditioned Space
Basement Wall Library List
Name Feet From Wall Tap To InsuIation Feet From Wall Top Tb Insulation Is Fully Insulated R -value
Top Bottom
R-11 Draped, 4ft 0 4 No 11.00
Slab
BSMT Uninsulated 174 Below Grade ❑ 0 1,712.0 sq. R. Exposed Exterior Conditioned
Space
Slab Library List
Name Wall C
Uninsulated Woad Frame / Other
Na ❑ 0 D 0.00
1
Building Summary
Property
Organization
Inspection Status
C-MEnergy Solutions
14324 NEW GARDEN LN
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: 3500 RIVIERA
Rim Joist
Community: LEGACY RIDGE 105
Builder
Name
Library Type
LENNAR HOMES
Location
CONDIAMB
-R1 05 (AS DESIGNED)
LEGACY RIDGE 105
270-0 sq. it.
Exposed Exterior
ramed Floor
Name Library Type
Carpet R
Floor Grade
Surface Area Location
OVER AMBIENT R-38, GR1
1.23
Above Grade
14.0 sq. ft Exposed Exterior
OVER GARAGE R-38, GR1
1.23
Above Grade
402.0 sq. ft Unconditioned, attached
Rim Joist Library List
garage
Framed Floor Library List
Name
R -value
-'•s :»
33.825
Rim Joist
Name
Library Type
Surface Area
Location
CONDIAMB
G1 R-13, R-3.0
270-0 sq. it.
Exposed Exterior
CONDIATTIC
G1 R-13, OSB
54-0 sq. ft.
Attic
CONDIGAR
G1 R-13, OSB
43-0 sq. ft.
Unconditioned, attached garage
Rim Joist Library List
Name
R -value
G1 R-13, OSB
10.876
G1 R-13, R-3.0
13.575
Name Library Type
CONDIAMB G1 R-13 BATT, R-3.0
:ONDIAMB 2X6 G1 R-19. R-3.0 2X6
Surface Calor
Medium
Medium
Surface Area
Location
2,367.0 sq. fl. Exposed Exterior
270.0 sq. ft. Exposed Exterior
Building Summary
Property Organization
14324 NEW GARDEN LN TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
Model: 3500 RIVIERA
Community: LEGACY RIDGE 105 Builder
LENNAR HOMES
-R1 05 (AS DESIGNED)
LEGACY RIDGE 105
Name Library Type
Inspection Status
Results are projected
Surface Calor
Surface Area
C-MEnergy Solutions
Location
CONDIATTIC G1 R-13 BATT, R-3 -0
Medium
206.0 sq. ft.
Attic
CONDIGAR G1 R-13 Gar Walls
Medium
387.0 sq. ft.
Unconditioned, attached garage
Wall Library List
Name
R-value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
G1 R-19, R-3.0 2X6
20217
Glazing
mqr
Name Library type Wall Assignment
Basement Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Hottom
BACK U-.31, SHGC-.32 CONDIAMB
0
0
0
West
174.0 sq. ft.
BACK 2X6 11-.31, SHGG.32 CONDIAMB 2X6
0
0
0
West
77.0 sq. fl-
tBACK
BACK2X6 GD U-29, SHGG.33 CONDIAMB 2X6
0
0
❑
West
18.0 sq. fl-
tFRONT
FRONT11-.31, SHGG29 CONDIAMB
0
0
❑
East
132.0 sq. ft.
LEFT SIDE 11-.31, SHGG.32 CONDIAMB
0
0
❑
South
59.0 sq. ft
LEFT SIDE BSMT U-.31, SHGC-.32
CONDIAMB
0
0
0
South
16.0 sq. fL
RIGHT SIDE U-.31, SHGG.32 CONDIAMB
0
0
0
North
83.0 sq. fl-
RIGHT
RIGHT SIDE BSMT U-.31, 3HGG.32
CONDIAMB
0
0
0
North
16.0 sq. R
3
Building Summary
Property
Organization
Inspection Status
14324 NEW GARDEN LN
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Matthew Timmons
FRONT Steel Door CONDIAMB
Model: 3500 RIVIERA
20.0 sq_ it
Exposed Exterior
Community: LEGACY RIDGE 105
Builder
18.0 sq_ R
Exposed Exterior
LENNAR HOMES
-R1 05 (AS DESIGNED)
LEGACY RIDGE 105
FGlazing Library List
Name
Shg c
U {actor
U-.29, SHGC-.33
0.33
0290
U-.31, SHGC-29
029
0.310
U-.31, SHGC-.32
0.32
0.310
Skylight
None Present
Skylight Library List
None Present
Opaque Doors
1
C-M,
Energy Solutions
Name Library Type Wal} Assignment Basement Wall
Emittance Solar Surface Color
SurfaceArea
Location
Assignment
Absorptance
FRONT Steel Door CONDIAMB
0.9 0.75 Medium
20.0 sq_ it
Exposed Exterior
GARAGE Steel Door CONDIGAR
0.9 0.75 Medium
18.0 sq_ R
Exposed Exterior
Opaque Door Library List
Name U fiactoi
Steel Door 0.182
4
Building Summary
Property
14324 NEW GARDEN LN
CARMEL, IN 46033
Model: 3500 RIVIERA
Community: LEGACY RIDGE 105
-R1 05 (AS DESIGNED)
LEGACY RIDGE 105
rRoof Insulation
Name
Library Typ
SECOND R-38 Blown. GR1
Roof Insulation Library List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
irea Gtay or ConCrete Root
P.f.] 'riles
2,128 No
Name Has Radiant Barrier
IR-38 Blown, GR1 No
Whale House Infiltration
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
None Present
38268
4
C-M,
Energy Solutions
it
Medium 2.128.0 sq. ft Attic
■
Lighting
°I Interior Fluorescent °I Interior LED Lighting °I Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent °I Garage LED Lighting
Lighting Lighting Lighting
0 100 0 100 C 100
Onsite Generation
None Present
.01
Building Summary
Property
14324 NEW GARDEN LN
CARMEL, IN 46033
Model: 3500 RIVIERA
Community: LEGACY RIDGE 105
-R1 05 (AS DESIGNED)
LEGACY RIDGE 10.5
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
nsite Generation Library List I
None
Solar Generation
Solar Generation Library List
None Present
C-M,
Energy Solutions
Conditioning Equipment
Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load
Air conditioner (2) CA13NA042 0% 1001 0%
Fuel -fired air 9155A48080S17 100% 0% 0%
distribution (1)
Water Heating (3) RE350" 0% 0% 100%
Equipment Type: 915SA48080SI
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
946
E uipment Type: CA13NA042
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Electric
Forced Air
PSC (Single Speed)
13 SEER
40
Building Summary
Property
14324 NEW GARDEN LN
CARMEL, IN 46033
Model: 3500 RIVIERA
Community: LEGACY RIDGE 105
LR105 (AS DESIGNED)
LEGACY RIDGE 105
quipment Type:
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity {gal.]
Hot Water Capacity [kBtulh]
Recovery Efficiency
RE350*
Distribution System
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Electric
Hydronic Delivery
0.93 Energy Factor
5❑
15.4
❑.98
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution (1 )
Cooling Equipment
Air conditioner (2)
Sq. Feet Served
4836
# Return Grilles
4
Supply Duct R Value
30
Return Duct R Value
20
Supply Duct Area [sq. ft.]
1365.72
Return Duct Area [sq. ft_]
967.2
Duct Leakage to Outdoors (CFM25)
288
Total Leakage
384
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
70
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
30
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
'-Ceiling Fan ��Ml
Has Ceiling Fan No
Cfm Per Watt 100
C-M,
Energy Solutions
7
Building Summary
Property
14324 NEW GARDEN LN
CARMEL, IN 46033
Model: 3500 RIVIERA
Community: LEGACY RIDGE 105
-R1 05 (AS DESIGNED)
LEGACY RIDGE 105
ater Distribution
I
ter Fixture Type
e Default Hot Water Pipe Length
t Water Pipe Length [ft]
Least R3 Pipe Insulation?
t Water Recirculation System?
circulation System Pipe Loop Length [ft]
in Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Standard
No
100
No
No
30
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�