Loading...
HomeMy WebLinkAboutLEGACY RIDGE 105 - LR105 (AS DESIGNED)IECC 2009 Performance Compliance Property 14324 NEW GARDEN LN CARMEL, IN 46033 Model: 3500 RIVIERA A Community: LEGACY RIDGE 105 LR105 (AS DESIGNED) LEGACY RIDGE 105 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,728 $272 $398 $2,398 $932 $0 $3,330 Requirements C-M, Energy Solutions As Designed $1,560 $256 $398 $2,214 $932 $0 $3,146 C4405.3 Performance-based compliance passes by 7.7% 402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 7.7%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 3113119 at 11:18 AM Ekotrope RATER - Version 3.1.0.2130 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 14324 NEW GARDEN LN �, FT Pi CARMEL, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.32 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 288.0 CFM @ 25Pa Total Duct Leakage 384.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 3113119 at 11:18 AM Ekotrope RATER - Version 3.1.0.2130 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 14324 NEW GARDEN LN TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA A Community: LEGACY RIDGE 105 Builder LENNAR HOMES LR105 (AS DESIGNED) LEGACY RIDGE 105 General Building Information Conditioned Area (sq ft) 5,348 Conditioned Volume (cubic ft) 47,840 Insulated Shell Area (sq ft) 9,419 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slake Name: BSMT (1,712 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor Name: OVER GARAGE (402 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I El Name: OVER AM8IENT (14 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall ] Name: CONDIAMB (Exterior Perimeter [ft]: 131, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 ] Name: CONDIGAR (Exterior Perimeter [ft]: 43, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (2,367 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property organization 14324 NEW GARDEN LN TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA A Community: LEGACY RIDGE 105 Builder LENNAR HOMES LR105 (AS DESIGNED) LEGACY RIDGE 105 El Name: CONDIAMB 2X6 (270 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (387 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIATTIC (206 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (270 s.f.) R: 13.575 Name: CONDIGAR (43 s.f.) R: 10.876 Name: CONDIATTIC (54 s.f.) R: 10.876 Roof El Name: SECOND (2,128 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 14324 NEW GARDEN LN TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA A Community: LEGACY RIDGE 105 Builder LENNAR HOMES LR105 (AS DESIGNED) LEGACY RIDGE 105 E] Name: FRONT (132 s.f.), U:0.310, SHGC: 0.29, Orientation: EAST E] Name: BACK (174 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST El Name: BACK 2X6 (77 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST El Name: BACK 2X6 GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST El Name: RIGHT SIDE (83 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH El Name: RIGHT SIDE BSMT (16 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH 11 Name: LEFT SIDE (59 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH 11 Name: LEFT SIDE BSMT (16 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER El Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested 3 House is air -sealed as to achieve 3,987 CFM50 (5.00 AC H50) or less at final blower -door test. Energy Code Inspection Checklist Property 14324 NEW GARDEN LN CARMEL, IN 46033 Model: 3500 RIVIERA A Community: LEGACY RIDGE 105 LR105 (AS DESIGNED) LEGACY RIDGE 105 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Infiltration Requirements for IECC in Climate Zone 5 Inspection Status Results are projected 2009 IECC. Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 288.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 384.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary C-M Energy Solutions Property Organization Inspection Status 14324 NEW GARDEN LN TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA Community: LEGACY RIDGE 105 Builder LENNAR HOMES -R1 05 (AS DESIGNED) LEGACY RIDGE 105 I eneral Building Informationmber Of Bedrooms 4 mber Of Floors 2 nditioned Floor Area [sq_ ft.] 5;348 conditioned, attached garage? Yes nditioned Volume [Cu. ft.] 47;840 tal Units in Building 1 sidence Type Single family detached adel 3500 RIVIERA A mmunity LEGACY RIDGE 105 mate Zone 5A Basement Wall d6 Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, Oft 1 8 131 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, Oft 1 8 43 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Tap To InsuIation Feet From Wall Top Tb Insulation Is Fully Insulated R -value Top Bottom R-11 Draped, 4ft 0 4 No 11.00 Slab BSMT Uninsulated 174 Below Grade ❑ 0 1,712.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall C Uninsulated Woad Frame / Other Na ❑ 0 D 0.00 1 Building Summary Property Organization Inspection Status C-MEnergy Solutions 14324 NEW GARDEN LN TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA Rim Joist Community: LEGACY RIDGE 105 Builder Name Library Type LENNAR HOMES Location CONDIAMB -R1 05 (AS DESIGNED) LEGACY RIDGE 105 270-0 sq. it. Exposed Exterior ramed Floor Name Library Type Carpet R Floor Grade Surface Area Location OVER AMBIENT R-38, GR1 1.23 Above Grade 14.0 sq. ft Exposed Exterior OVER GARAGE R-38, GR1 1.23 Above Grade 402.0 sq. ft Unconditioned, attached Rim Joist Library List garage Framed Floor Library List Name R -value -'•s :» 33.825 Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-13, R-3.0 270-0 sq. it. Exposed Exterior CONDIATTIC G1 R-13, OSB 54-0 sq. ft. Attic CONDIGAR G1 R-13, OSB 43-0 sq. ft. Unconditioned, attached garage Rim Joist Library List Name R -value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 Name Library Type CONDIAMB G1 R-13 BATT, R-3.0 :ONDIAMB 2X6 G1 R-19. R-3.0 2X6 Surface Calor Medium Medium Surface Area Location 2,367.0 sq. fl. Exposed Exterior 270.0 sq. ft. Exposed Exterior Building Summary Property Organization 14324 NEW GARDEN LN TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: 3500 RIVIERA Community: LEGACY RIDGE 105 Builder LENNAR HOMES -R1 05 (AS DESIGNED) LEGACY RIDGE 105 Name Library Type Inspection Status Results are projected Surface Calor Surface Area C-MEnergy Solutions Location CONDIATTIC G1 R-13 BATT, R-3 -0 Medium 206.0 sq. ft. Attic CONDIGAR G1 R-13 Gar Walls Medium 387.0 sq. ft. Unconditioned, attached garage Wall Library List Name R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.0 2X6 20217 Glazing mqr Name Library type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Hottom BACK U-.31, SHGC-.32 CONDIAMB 0 0 0 West 174.0 sq. ft. BACK 2X6 11-.31, SHGG.32 CONDIAMB 2X6 0 0 0 West 77.0 sq. fl- tBACK BACK2X6 GD U-29, SHGG.33 CONDIAMB 2X6 0 0 ❑ West 18.0 sq. fl- tFRONT FRONT11-.31, SHGG29 CONDIAMB 0 0 ❑ East 132.0 sq. ft. LEFT SIDE 11-.31, SHGG.32 CONDIAMB 0 0 ❑ South 59.0 sq. ft LEFT SIDE BSMT U-.31, SHGC-.32 CONDIAMB 0 0 0 South 16.0 sq. fL RIGHT SIDE U-.31, SHGG.32 CONDIAMB 0 0 0 North 83.0 sq. fl- RIGHT RIGHT SIDE BSMT U-.31, 3HGG.32 CONDIAMB 0 0 0 North 16.0 sq. R 3 Building Summary Property Organization Inspection Status 14324 NEW GARDEN LN TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons FRONT Steel Door CONDIAMB Model: 3500 RIVIERA 20.0 sq_ it Exposed Exterior Community: LEGACY RIDGE 105 Builder 18.0 sq_ R Exposed Exterior LENNAR HOMES -R1 05 (AS DESIGNED) LEGACY RIDGE 105 FGlazing Library List Name Shg c U {actor U-.29, SHGC-.33 0.33 0290 U-.31, SHGC-29 029 0.310 U-.31, SHGC-.32 0.32 0.310 Skylight None Present Skylight Library List None Present Opaque Doors 1 C-M, Energy Solutions Name Library Type Wal} Assignment Basement Wall Emittance Solar Surface Color SurfaceArea Location Assignment Absorptance FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 sq_ it Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 sq_ R Exposed Exterior Opaque Door Library List Name U fiactoi Steel Door 0.182 4 Building Summary Property 14324 NEW GARDEN LN CARMEL, IN 46033 Model: 3500 RIVIERA Community: LEGACY RIDGE 105 -R1 05 (AS DESIGNED) LEGACY RIDGE 105 rRoof Insulation Name Library Typ SECOND R-38 Blown. GR1 Roof Insulation Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected irea Gtay or ConCrete Root P.f.] 'riles 2,128 No Name Has Radiant Barrier IR-38 Blown, GR1 No Whale House Infiltration Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested Mechanical Ventilation None Present 38268 4 C-M, Energy Solutions it Medium 2.128.0 sq. ft Attic ■ Lighting °I Interior Fluorescent °I Interior LED Lighting °I Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent °I Garage LED Lighting Lighting Lighting Lighting 0 100 0 100 C 100 Onsite Generation None Present .01 Building Summary Property 14324 NEW GARDEN LN CARMEL, IN 46033 Model: 3500 RIVIERA Community: LEGACY RIDGE 105 -R1 05 (AS DESIGNED) LEGACY RIDGE 10.5 Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES nsite Generation Library List I None Solar Generation Solar Generation Library List None Present C-M, Energy Solutions Conditioning Equipment Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Air conditioner (2) CA13NA042 0% 1001 0% Fuel -fired air 9155A48080S17 100% 0% 0% distribution (1) Water Heating (3) RE350" 0% 0% 100% Equipment Type: 915SA48080SI Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSC (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 E uipment Type: CA13NA042 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Electric Forced Air PSC (Single Speed) 13 SEER 40 Building Summary Property 14324 NEW GARDEN LN CARMEL, IN 46033 Model: 3500 RIVIERA Community: LEGACY RIDGE 105 LR105 (AS DESIGNED) LEGACY RIDGE 105 quipment Type: Fuel Type Distribution Type Hot Water Efficiency Tank Capacity {gal.] Hot Water Capacity [kBtulh] Recovery Efficiency RE350* Distribution System Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Electric Hydronic Delivery 0.93 Energy Factor 5❑ 15.4 ❑.98 Distribution Type Forced Air Heating Equipment Fuel -fired air distribution (1 ) Cooling Equipment Air conditioner (2) Sq. Feet Served 4836 # Return Grilles 4 Supply Duct R Value 30 Return Duct R Value 20 Supply Duct Area [sq. ft.] 1365.72 Return Duct Area [sq. ft_] 967.2 Duct Leakage to Outdoors (CFM25) 288 Total Leakage 384 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 70 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 30 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ '-Ceiling Fan ��Ml Has Ceiling Fan No Cfm Per Watt 100 C-M, Energy Solutions 7 Building Summary Property 14324 NEW GARDEN LN CARMEL, IN 46033 Model: 3500 RIVIERA Community: LEGACY RIDGE 105 -R1 05 (AS DESIGNED) LEGACY RIDGE 105 ater Distribution I ter Fixture Type e Default Hot Water Pipe Length t Water Pipe Length [ft] Least R3 Pipe Insulation? t Water Recirculation System? circulation System Pipe Loop Length [ft] in Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Standard No 100 No No 30 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year "M � C-M, Energy Solutions ,�