Loading...
HomeMy WebLinkAboutP0.1-PLUMBING-NOTES-AND-SCHEDULE-Rev.063 N 0 w A rn N L' PLUMBING LEGEND SYMBOL ABBREV. DESCRIPTION ABBREV. DESCRIPTION SS SANITARY SEWER OR WASTE B/G AFF ABOVE FINISHED FLOOR A/G ABOVE GRADE V VENT B/F BELOW FLOOR DCW DOMESTIC COLD WATER DHW DOMESTIC HOT WATER BIG BELOW GRADE DHWR DOMESTIC HOT WATER RETURN CONIC. CONCRETE CD CD CONDENSATE DRAIN CONN. CONNECTION DE DE DEIONIZED WATER CONT. CONTINUATION DER DER DEIONIZED WATER RETURN ON. DOWN DS DS DOWNSPOUT OF DRINKING FOUNTAIN F F FIRE MAIN FF ELEV. FINISHED FLOOR ELEVATION SPK SPK FIRE SPRINKLER FG FINISHED GRADE NJ MJ INDIRECT WASTE FH FIRE HYDRANT G G NATURAL GAS (LOW PRESSURE) FU FIXTURE UNIT MPG MPG NATURAL GAS (MEDIUM PRESSURE) FT FLUSH TANK HPG HPG NATURAL GAS (HIGH PRESSURE) FV FLUSH VALVE ODS ODS OVERFLOW DOWNSPOUT GPM GALLONS PER MINUTE ORW ORW OVERFLOW RAIN WATER HC HANDICAPPED RW RW RAINWATER VA IN ATTIC OR ABOVE CEILING SD SO STORM DRAIN I.E. INVERT ELEVATION TP TP TRAP PRIMER LAV LAVATORY FCO FLOOR CLEAN -OUT MH MANHOLE �� COTG CLEAWOUT TO GRADE MS MOP SINK WCO WALL CLEAN-0UT PN POST INDICATOR VALVE �+ HB HOSE BIBB RI & C ROUGH -IN & CONNECT � PIPE RISING SS SERVICE SINK PIPE DOWN SH SHOWER p4 S.O.V. SHUT-OFFVALVE S SINK SHUT-OFF VALVE ON RISE OR DROP TYP. TYPICAL C4 GLV GLOBE VALVE U/G UNDERGROUND N CV CHECK VALVE U URINAL BALANCING VALVE VTR VENT THRU ROOF GASCOCK WC WATER CLOSET e WHA WATER HAMMER ARRESTOR WH WATER HEATER �O FD FLOOR DRAIN W/ NTH ® FSK FLOOR SINK ® CB CATCH BASIN RD ROOF DRAIN ORD OVERFLOW ROOF DRAIN P.O.C. POINT OF CONNECTION RELEASED FOR CONSTRUCTION -vp Subject to compliance with all regulations of State and Local Codes City offCamrel (} PLUMBING FIXTURE SCHEDULE CALLOUT TYPE MANUFACTURER MODEL DESCRIPTION WC-1 WATER CLOSET -ADA AMERICAN STANDARD MADERA ADA, FLOOR MOUNT, FLUSH VALVE,1.1 GPF L-1 LAVATORY AMERICAN STANDARD DECLYN ADA, WALL MOUNT, VITREOUS CHINA, 4" CENTER HOLE, AMERICAN STANDARD COLONY PRO, 0.5 GPM, SINGLE HANDLE FAUCET, TEMPERING VALVE FOR 110 F MAX. DHW S-1 KITCHEN SINK AMERICAN STANDARD COLONY- 22S8.63322&1S.075 ADA, 25'k225c5", SINGLE BOWL, ZO GAUGE STAINLESS STEEL, 4 HOLE, WITH COLONY SOFT-4275.550.F15-1.5 GPM TWO HANDLE FAUCET GENERAL NOTES GENERAL NOTES NOTE NUMBER NOTE 1 THE PLUMBING CONTRACTOR SHALL FURNISH ALL MATERIALS AND LABOR TO COMPLETE THE WORK INDICATED ON THE DRAWINGS AND SPECIFICATIONS. 2 ALL WORK SHALL BE COMPLETED IN COMPLIANCE WITH THE INTERNATIONAL PLUMBING CODE, AND OTHER STATE AND LOCAL CODES. 3 THE PLUMBING CONTRACTOR SHALL VERIFY ALL LOADS AND PIPE SIZES PRIOR TO STARTING WORK. 4 THE PLUMBING CONTRACTOR SHALL MAINTAIN ALL REQUIRED CLEARANCES AROUND PLUMBING EQUIPMENT, AND COORDINATE WITH OTHER TRADES TO MAINTAIN CODE REQUIRED CLEARANCES. 5 FOR FIRE RATED WALLS AND CEILINGS, SEE ARCHITECTURAL DRAWINGS. 6 ALL PENETRATIONS THROUGH WALLS, ROOFS, AND FLOORS SHALL BE FIRE STOPPED. 7 THE PLUMBING CONTRACTOR SHALL COORDINATE WITH LOCAL UTILITY COMPANY, AND PROVIDE ALL LABOR AND MATERIAL, AND PAY FEES TO PROVIDE A COMPLETE PLUMBING SYSTEM. 8 FOR FIXTURE HEIGHT AND ACCESSIBILITY REQUIREMENTS, SEE ARCHITECTURAL DRAWINGS. 9 ALL INVERT ELEVATIONS (TOP OF PIPE) REPRESENTED BY - XXX FT. ARE BELOW FINISHED FLOOR ELEVATION. 10 COORDINATE FIXTURE AND EQUIPMENT LOCATIONS, AND UTILITY CONNECTIONS, WITH OTHER TRADES. 0 _ U E11 J m 38S m E11 `5a o 0 a 0 U QµOFESS�Q 4� N9l Na.aEms aaaz m 0 S�grF OF Co ��t sS,�Eoonooa=° °om -oea„„o_da Ea a T „ ° ° a a_aomv_° -5m FoE°�so LW e�� Dva Fa°&.oE Bpi 8 R vEov oL=; °eoaosm .anog€a`r�oo4vom o® fa��o3rs oi�°-vua"—m E°tea"oEa�va ° a D3Wz'_ oa&u'oE ono o= PEa C110 ao"u c 0 .N E 0 U w U L ^ LL J `o � o 0 J `o� Q> > CTN LLJ (0 Q U7 (n fn eh Vl O 7 N Cy m � wsZ p� wm� GCE � 'D D� a # Date PRJJFCf 9AI11S STATE SUBMITTAL PROJfCI tl' NUMBER. PROJfC765LE DATE' 19149 20190507 DRAWN or RENEWED or RBT LLASHEET sNFa.nJf, PLUMBING NOTES AND SCHEDULE P0.1 DATE: 06/27/19